Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 CrAccepted-AOC | ₹12.5 Cr Quoted ₹12.7 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹13.5 CrRejected-Finance | ₹13.5 Cr | L2 | Rejected-Finance Other Than L1 Bidder |
| 3 | L3₹13.6 CrRejected-Finance | ₹13.6 Cr | L3 | Rejected-Finance Other Than L1 Bidder |
| 4 | L4₹13.9 CrRejected-Finance | ₹13.9 Cr | L4 | Rejected-Finance Other Than L1 Bidder |
| 5 | L5₹14.2 CrRejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹14.2 Cr | L5 | Rejected-Finance Other Than L1 Bidder |
Tender Value
₹14.4 Cr
EMD Value
₹10.4 L
Closing Date
24 Mar 2022, 6:00 pmClosed
Chief Engineer Lucknow
Chief Engineer Lucknow Zone, 17 Carriappa Marg Post Dilkusha, Lucknow Cantt -226002
ADDITION/ALTERATION TO WARDS, OT ROOMS AND LABS OF MH AGRA.
2022_MES_503450_1
CELZ/AGR/T-34 OF2021-22
Open Tender
Civil Works
730 days
GE (West) Agra
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE(West) AGRA
₹10.4 L
Yes
4 Jun 2022
24 Jan 2022
26 Mar 2022
24 Jan 2022
24 Mar 2022
12 Mar 2022
2 Feb 2022 - 9 Feb 2022
Amount
BUILDING WORK Demolition of reinforced cement concrete roof,floor (other than ground floor) beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Removing building materials to a distance of 1.0 Km, including loading, unloading and stacking at the destination complete all as specified and directed.
Dismantling cement ( corrugated semicorrugated ,etc) sheets in roof covering including L type or J type hooks or cranked bolts etc complete all as specified and directed
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet for ridges 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for 1 mm thick plain galvanised mild steel sheeting in ridges ,hips,valley guttres, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 gm per Square meter complete all as specified and directed.
M&L for taking down/dismantling of existing roof treatment of any description such as PCC Padding/ Coba treatment/ mud phuska/Lime conc terracing including screed bed etc. Hessian base felt/tar felt etc. (any type and thickness) complete all as specified and directed.
M&L cutting out cracks to 'V' section in existing roof or terraces cleaning out wetting grooves and suppling and filling cement mortar in cement mortar (1:3) complete all as specified and directed.
M&L providing PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in bed plates coping, padding without extra cement smooth finish complete all as specified and directed.
Material and labour for applying 10 mm thick plaster on concrete surface in cement mortar 1:4 including water proofing compound @ 3% by weight of cement complete all as specified and directed.
S&F galvanised welded steel wire fabric as extra re-inforcement to RCC members like ceilings, chajja’s, beams, columns parapet walls, waste slab etc including all cutting and waste (wt not exc 4.00 kg/Sqm) complete all as specified and directed.
Material and labour for water proofing treatment of roof slab all as specified below. ( Note- Each stage passed by Engineer-in-Charge and approved by GE) (a) Preparation of plaster surface roof by brushing and cleaning . (b) Applying a priming coat with bitumen primer @0.5 Kg/Sqm. (c) Applying tack coat of hot blown industrial bitumen grade 85/25 @ 1.20 Kg per sqm . (d) Laying polymeric water proofing membrane APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
M&L cutting grooves in brick wall 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 and suppling and filling cement mortar in cement mortar (1:3) complete all as specified and directed.
Material and labour PCC 1:2:4 type B-0 using 12.5 mm stone aggregate in fillets junction of roof and parapet wall caving slightly chamfered or rounded including water proofing compound @3% by weight of cement complete all as specified and directed.
M&L for 40mm thick brick tiles laid on cement mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement including over 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for applying one coat of epoxy resin (Fair Bond EP) on old concrete surfaces of ceiling and beam chhajja stair case etc @ 0.30 Kg/Sqm including 25 mm thick (average thickness) of cement and sand (Fine grit) in ratio 1:3 mixed with chloride free spray concrete plastisizer (spray rete) as per manufacture instruction with guiniting machine pressure capacity not less than 5 Kg per Sqcm and finished the surfaces even and smooth complete all as specified and directed.
M & L rendering cement plaster 10 mm thick in cement mortar 1:4 on concrete surfaces as in ceiling and finished the surface fair and even without using extra cement complete all as specified and directed.
M & L for three coats of white wash on new plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
Taking down wooden roof truss exc 4 m but n.exc 8 m coupled rafters or trussed beams span complete all as specified and directed.
M&L roof truss (framed trussed, purlins, crane gantries, rails and fastening including distance pieces cleats etc confirming to Fe290 grade E-165 complete all as specified and directed.
Dismantling timber scantlings 40 Sq. cm and over in section and in any position complete all as specified & directed.
M & L cutting holes into or through brick wall built in cement mortar superfacial area exc 150 Sqcm not exc 400 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 using stone aggregate 20 mm as required complete all as specified and directed.
M&L reinforced cement concrete nominal mix 1:2:4 type B1 using stone aggregate 20 mm in slab supported on walls, beam, and columns in floors, roof and the like complete all as specified and directed.
TMT bars of 10 mm dia and over, dia cut to length bent to shape required including cranking bending spirally, hooking ends and binding with mild steel wire not less than 0.9 mm dia(annealed) complete all as specified and directed . (Note - The payment shall be made only after placing of cover on manholes.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surfaces of concrete complete all as specified and directed.
Formwork to edges of concrete flats, treads breaks in floors, window cill, conctete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed.
M&L RCC M-25 (Design Mix) in foundations,including rafts,footings,foundation beams,plinth beams, plinth bands;bases for columns,etc basement slabs,under reamed piles and mass concrete complete all as specified and directed.
M&L RCC M-25 (Design mix) in beams, cantilevers, bressummers, lintels over 1.5 metre span complete all as specified and directed.
M&L RCC M-25 (Design mix) in columns,pillars,piers,posts and struts complete all as specified and directed.
Mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with wire, in stirrups and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for formwork to side of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter rough flate finished surfaces of concrete all as specified and directed.
M&L for formwork to side and soffits of floor or roof beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhands, etc also splays between floors and beam etc rough flats finished surfaces of concrete all as specified and directed.
M&L for formwork to side of pillars, posts, struts, piers, columns and stanchions etc square, rectangular or polygonal fair finished surfaces of concrete complete all as specified and directed.
S&F mild steel joist channel angle or I sections fixed independently with or without connecting plates etc of grade Fe-410-0 & Fe 310-0 complete all as specified and directed.
S&F rolled section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc confirming to Fe290 grade E-165 complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in bed block and coping and benching embedding of hold fast etc complete all as specified and directed
Demolition of brickwork built in cement mortar including all quoins arches pillar etc complete all as specified and directed.
Excavation in trenches, in any kind of soil not exceeding 1.50 meter wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed . (Surplus soil if any shall not be removed & spread over the trench)
Removing excavated soil n.exc. 50 metre and deposited where directed at a level n.exc. 1.5 metre above the starting point complete all as specified and directed.
M&L brick work with fly ash bricks ( old Size) in cement mortar (1:6) straight or curved on plan exceeding 6.00 metre mean radius complete all as specified and directed.
Taking down cement plaster on brick or stone walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for three coats of white wash on new plastered surface on walls including prepration of surfaces complete all as specified and directed.
M&L for one coat of white wash on old plastered surface on walls ,ceiling including prepration of surfaces complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying two coats of weather proof exterior paint silicon based over a coat of water based suitable primer as a base course as per manufacturer's instructions complete all as specified and directed.
M&L for rendering 15 mm thick on any faces of brick work in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Dismantling wall and ceiling boards( fibre pulp, insulation etc) or insulation board /slabs/blanket any thickness including cover fillets complete all as specified and directed.
Anodised aluminium snap grid frame work of size 605 mm x 605 mm for false ceiling including S&F of grid 605 mm x 605 mm hangers 6 mm dia GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 mm x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long complete all as specified and directed.
M&L for 4 mm thick non asbestos fibre cement building designer boards fixed in ceiling or laid/inserted to timber/GI/aluminun frame complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic colour tiles joint free 7 to 8 mm thick (Square /rectangle) area of each tile excedding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and ponted in white or coloured cement to match over 15 mm thick screed bed in cm 1:6 complete all as specified and directed.
All as per item No-52 but on verticle surfaces such as skirting/dado over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for vitrified light shade ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed.
All as per item No-54 but on verticle surfaces such as skirting/dado over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tile 350x250x7mm / 450x350x7mm thick jointed and pointed with white or coloured cement over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
S&F solid PVC Wall lining consisting of 5mm thick plain but single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
All as per item No 59 before but exc 1.5 Sqm and not exc 4.00 Sqm each complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows ventilators with one or more rebate including joining cleats, screws, for fixing etc complete all as specified and directed.
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws etc complete all as specified & directed.
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 nos.) suitable handle (1 no.) complete all as specified & directed.
S&F powder coated aluminium partition of specified aluminium section top rail and middle rail 2.36 Kg/RM, bottom channel 2.59 Kg/RM including aluminium beads rubber gasket and 5mm thick frosted glass in upper portion and 12 mm thick prelaminated particle board, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination complete all as specified and directed.
S&F powder coated anodised grill with mesh size 75 mm and aluminium bar 6 mm XPM type approved design/pattern, including all accessories such as channels for fixing grill screws etc, aluminium section 15 micron thick anodizing complete all as specified and directed.
S & F galvanized mild steel wire cloth 0.50 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
S&F 12 mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination , fixed with screws to timber/ aluminium frame work and sealing edges of board with PVC beading by chemical adhesive complete all as specified and directed.
S&F 4.8 mm thick sheet glass ordinary quality and glazing not exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F 5 mm thick figured glass, pinhead exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F 100mm long aluminium anodised Hasp and Staple, safety type including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F 4.8 mm thick sheet glass ordinary quality and glazing exceeding 0.50 Sqm in each pane complete in aluminium partition and window all as specified and directed.
S&F for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F mortice lock, vertical type of size 100 mm with mild steel body 4 lever complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 75 mm thick (1:3:6) type C-1 using 20 mm graded stone aggregate , plinth protection complete all as specified and directed.
M&L in repair machine pressed coloured chequered tiles 25 cm x 25 cm x 25 mm thick set, jointed & pointed in grey cement with pigment including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M& L washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1: 4 with water proofing compound @ 2% by weight of cement ( 1 cement : 4 coarse sand ) furrowing the under layer with scratching tool applying cement slurry on the under layer @ 3 Kg of cement per square metre top layer 15 mm cement plaster 1:1 / 2 : 2 , 01 cement (1/2 white ,1/2 gray ): 1/2 coarse sand : 2 stone chipping 10 mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings complete all as specified and directed. (payment for providing grooves and water proofing compound shall be made separately)
Forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens nailed to the under layer including removal of wooden battens repair to the edges of panels and finishing the groove complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Cutting openings in brick wall built in cement mortar, through brick walls for door, window and other openings or enlarging existing openings, converting window into door opening etc or cutting out defective brick work for under pinning including providing fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc 50 m complete all as specified and directed.
Taking down shutter with frame exc 1 Sqm and not exc 2.00 Sqm each complete all as specified and directed.
S&F Soild PVC door frame of size 50 mm x 47 mm made out of 5 mm plain coloured PVC sheet, reinforced with MS square tube supplying and fixing in opening as per specification and drawing complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specifications & drawings shown in section 8 of SSR Part II complete all as specified and directed.
M & L for taking up or down 20 mm bore dia steel tubing and connections, including removal to store/ site complete all as specified and directed.
M & L for taking up or down 15 mm bore dia steel tubing and connections, including removal to store/ site complete all as specified and directed.
S&F 15mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20 mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L in repair gun metal ,globe or gate valve 20 mm with iron wheel head ,screwed both ends for iron pipe complete all as specified and directed.
S & F in repair CP Bib taps fancy type cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed (15mm bore dia of pipe ) complete all as specified and directed.
S & F in repair CP Stop valves fancy type ( angle valve) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed ( 15mm bore dia of pipe ) complete all as specified and directed.
S & F in repair 15mm bore dia Pillar taps fancy type cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs brass CP mixer ( wash basin /wall )15 mm bore for mixing hot & cold water screwed down for iron pipe or any type of pipe and fixed in position and making good disturbed portion complete all as specified and directed.
S & F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe complete all as specified and directed.
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F in repair shelf PTMT fixed with and incl CP brass screw and wooden / plastic cleats ( min wt 300 gm) complete all as specified and directed.
S&F in repairs Vitreous China wash hand basin white flat back size 550 mm x 400 mm including brackets , waste pipe,complete all as specified and directed.
S&F in repairs Rotational moulded HDPE water storage tanks triple layered ISI marked 500 litre capacity with cover & 20 mm ball valves high pressure of PTMT with epooxy coated aluminium rod & high density plastic ball (cylindrical vertical with closed top) hoisted and fixed in position incl disconecting of existing tank all as specified in SSR Part I (Capacity in litres 500) complete all as specified and directed.
S&F in repairs Rotational moulded HDPE water storage tanks triple layered ISI marked 1000 Litre capacity with cover & 20mm ball valves high pressure of PTMT with epooxy coated aluminium road & high density plastic ball (cylindrical vertical with closed top) hoisted and fixed in position incl disconecting of existing tank all as specified in SSR Part I (Capacity in litres 1000) complete all as specified and directed.
S&F in repairs Rotational moulded HDPE water storage tanks triple layered ISI marked 2000 Litre capacity with cover & 20mm ball valves high pressure of PTMT with epooxy coated aluminium road & high density plastic ball (cylindrical vertical with closed top) hoisted and fixed in position incl disconecting of existing tank all as specified in SSR Part I (Capacity in litres 2000) complete all as specified and directed.
S&F in repair sinks made of stainless steel 1 mm thick kitchen with plugs, washers and wastes pipe; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495 mm x 420 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan pedestal pattern white (excl fixing bolt flushing cistern and flush pipe ) fixed in repairs complete with seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminum hinging device complete all as specified and directed.
S&F in repairs vitreous China Orissa pan with integral foot rest size 580 mm x 440 mm white with ‘P’ or ‘S’ trap front or back inlet and foot rests any pattern including concrete bedding complete all as specified and directed.
S&F in repairs low level flushing cistern of capacity 10 litre ISI marked complete with inlet ball valve , and handle including bracket of Commander/Hindware/ complete all as specified and directed.
S&F in repair 125mm PTMT Grating with waste hole minimum weight 40 gm complete all as specified and directed .
S&F in repair Stainless steel toilet paper holder recessed type complete all as specified and as directed
S & F in repair Chromium plated brass hand ablution health faucet with and including 1.50 mtr long flexible tube fancy type with necessary brass nuts & rubber washers, cover with chromium plated spring complete all as specified and directed.
S&F in repair soap dish, brass, chromium plated,size 100X60mm, fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
S&F wardrob hooks made up of brass (Single ) 50mm to 60mm complete all as specified and as directed
S&F in repair chromium plated tubular towel rail 20 mm dia D type 60cm long between flanges complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) Soil waste, rain water pipe and vent pipes single socketed in any length with rubber ring joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed
S&F in repair 110 mm bore PVC (SWR) bends of any radius with access door including making good disturbe portion to match the existing complete all as specified and directed .
S & F in repair 110 mm bore dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F in repair 75mm bore dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F in repair PVC (SWR) Bend any radious of 75 mm dia complete all as specified and directed.
S & F in repair PVC (SWR) Junction (Single 'T' ) equal or un equal of 75 mm dia complete all as specified and directed
M & L in repair PVC (SWR) Gully traps125/110 mm setting and jointing with solvent cement complete all as specified and directed.
S & F in repair PVC (SWR) Vent Cowl 110 mm dia complete all as specified and directed
M&L for 75 mm dia of PVC (SWR) floor trap, plain with grating including with solvent cement complete all as specified and directed.
M&L Machine cut kota stone 20-25 mm thick as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and mirror polishing over 20 mm thick screed bed in CM ( 1:4) as in floor complete all as specified and directed.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
M&L Providing 35 mm thick precasted concrete louvers and jallies (measured solid) including all moulding frame type Bo,1:2:4 set in cement mortar 1:4 complete all as specified and directed.
M&L for framed work as in doors and gates of angle or other section including stringers, braces etc complete drilled for fixing of steel sheeting or other coverings to doors etc conforming FE-410-W complete all as specified and directed.
M&L for granite stone 12 to 15 mm thick glazed (table rubbed and polished) fixed as in plateform and the like set in cement mortar 1:4 and pointed with white cement (1:2) using marble dust with admixture of pigment to match the shade of slab and exposed edges rounded with & including screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed
ROAD/PATH/CULVERT Demolition of PCC of any size and shape any description any position complete all as specified and directed.
M&L for PCC 1:4:8,type D-2 using 40mm graded crushed stone aggregate as in sub base and mass concrete complete all as specified and directed.
M&L PCC 25 mm thick (1:2:4) type B-0 using 12.5 mm graded aggregate as in leveling and slope maintaining complete all as specified and directed.
M&L for moorum/red bajri filling in road side berm or paving, laid in layers not exc 15cm thick, spread levelled rammed and consolidated to required gradient and camber with 0.20 to 0.50 tonne hand roller including watering complete all as specified and directed.
Taking down of old precast interlocking paver block any size and shape any description and in any position and through at low level with in cantt area complete all as specified and directed..
M&L for 80 mm thick precast PCC interlocking coloured paver rubber moulded block factory made of grade M 40 single layer monolithic high density manufactured by electro vibro hydraulically operated block making maching conforming to IS -15658- 2006 laid and jointed over sand cushion layer with grey cement and pigment complete all as specified and directed. Note : Sand cusion shall be measured & paid separately
M&L for shingle filling 25 mm thick sand cushion layer for laying interlocking pavers complete all as specified and directed.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25 mm thick with grey cement and pigment in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over 15 mm thick screed bed in CM 1:6. complete all as specified and directed.
M&L for Pre-cast cement concrete kerb stone 1:2:4 type B-1 (using 20 mm graded stone aggregate) required sizes including jointed pointed in cement mortar 1:4 embeding in the ground to a depth as indicated taping earth arround kerb stone and also romovig surplus soil etc complete all as specified and directed .
M&L for two coats of synthetic enamel paint over a coat of primer in different tint as in band/strips in narrow width and similar works including preparation of new or previously untreated surfaces complete all as specified and directed.
SECURITY WALL Demolition of brick work masonry built in cement mortar including all square, arches, pillars etc but excl ashlars facing dressed stone work and precast concrete articles complete all as specified ,shown on drawing No 725, sheet No 1/1 and directed.
M&L brick work with fly ash brick straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed.
All as per item No 137 above but with old brick obtained from demolition complete all as specified and directed.
M&L RCC M-25 (Design Mix) concrete in beams complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over,cut to length,bent to shape required,including cranking,bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips.complete all as specified and directed.
Mild steel TMT bars 8 mm dia cut to length bend to shape required, including, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in stirrups complete all as specified and directed.
Form work to sides of concrete foundation footings, bases of columns raft and raft beams plinth beams, side and soffits of foundation and similar works.rough finished surface complete all as specified and directed.
Dismentling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
S&F MS work in angle iron swan neck fixed independently in bed block complete all as specified and directed.
M&L galvanised 2 strand 2.24 dia steel barbed wire, barbed wire, 2mm dia barbs at 75mm (approx) spacing and straining and fixing to any type of post, straining bolts including securing or tying at crossing with and provision of galvanised MS wire,staples or steel pins etc. complete all as specified and as shown on drawing including straning bolts as specified and directed by Engineer -in-Charge (Each line of wire to be measured).
Dismentling of structural steel work including doors , gates but excluding framed truss etc complete all as specified and directed.
Steel gate 7.50 metre wide (alongwith wicked gate) with RCC pillars and 5 Metre high RCC Arch including steel reinforcement and form work complete furnished with granite work and Stainless steel alphabates quoted "MILITARY HOSPITAL AGRA " with MS work locking arrangement, pintel hinges including earth work complete as under item No 147.01 to 147.14 ,complete all as specified and directed by Engineer in Charge :-
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using stone aggregate as in foundation complete all as specified and directed.
Form work to sides of concrete foundation footings, bases of colums raft and raft beams plinth beams, side and soffits of foundation and similar works.rough finished surface complete all as specified and directed.
S&F formwork to sides of pillars, posts, struts, piers, columns and stanchions fair finished surfaces of concrete complete all as specified and directed.
All as per item No 147.04 above but on circular surface complete all as specified and directed.
M&L RCC M-25 (Design Mix) in foundations,including rafts,footings,foundation beams,plinth beams, plinth bands;bases for columns,etc basement slabs,under reamed piles and mass concrete complete all as specified and directed.
M&L RCC M-25 (Design mix) in columns,pillars,piers,posts and struts complete all as specified and directed.
Returning filling in incl spreading levelling watering and well ramming in layers n exc 25cm thickness complete all as specified and directed.
Removing of surplus excavated soil to as distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
S&F mild steel work in framed work such as grill etc with ends of bars shouldered and/ or riveted or forged into spikes framed garder bar, bared ironed door hung as gate including pintle hinges stops and made sliding bolt and similar work confirming to Fe- 290 Gde-E-165 complete all as specified and directed.
M&L mild steel TMT bar 10 mm dia and over cut to length bend to shape spirally for hooking for column and hooking ends and binding with mild steel wire not less than 0.9 mm dia complete all as specified and as directed .
All as per item No 147.11 above but 5 mm dia and over upto and including 10 mm dia as in stirrup all as specified and as directed .
M&L 20 mm thick granite (of any type) tiles machine cut, in skirting/ dado laid over cement plaster 15mm thick in cement mortar 1:3 finished even and smooth and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
S&F Stainless steel 300 mm wide and height of letter not exc 400 mm made up of 1mm thick sheet with hanging arrangment on Granite finishes arch 5 metre heigh complete all as specified and directed.
M&L Providing 35 mm thick precasted concrete louvers and jallies (measured solid) including all moulding but execluding frame type Bo,1:2:4 ,using 12.5 mm graded stone aggregate set in cement mortar 1:4 complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick on any faces of brick work in CM 1:4 finished even and smooth without using extra cement with liquid water proofing compound complete including forming of grooves at joints all as specified and directed.
All as per above item No 150 above but on other than fair face of brick work finished even and smooth surface complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1: 4 (1 cement and 4 coarse sand ) furrowing the under layer with scratching tool ,applying cement slurry on the under layer @ 3 Kg of cement per square metre , top layer 15 mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in Pnnels and grooves all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed.
Forming grooves of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern complete all as specified and directed.
M&L for preparation of new surface with chalk whiting of wall and applying two coats of cement based paint complete all as specified and directed.
M&L for preparation of new steel surfaces exc 10cm width ot girth and applying two coats of synthetic enamel paint over one coat of red oxide complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n. exc. 15 cm thickness (below or avove ground level) complete all as specified and directed.
M&L for PCC type B1(1:2:4) using 20 mm graded cushed stone aggregate as in coping ,benching and the like including form work complete all as specified and directed.
AREA DRAINAGE Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Excavation in trenches n exc 1.5 metre wide and n exc 1.5 metre deep and getting out in any type of soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well ramming in layers n exc 25cm thickness complete all as specified and directed.
Removing excavated soil to a distance exc 50m and nexc1.50 km out side defence land complete all as specified and directed.
M&L For PCC type B1(1:2:4) using 20 mm graded crushed stone aggregate as in band , coping ,benching and the like including form work complete all as specified & directed .
M&L for PCC type B2 (1:2:4) using 40 mm graded cushed stone aggregate as in surface channels and drain beds complete all as specified & directed .
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified & directed .
Add or deduct for each 25 mm girth or part there of over or under 30 cm complete all as specified & directed .
M&L for PCC type D2 (1:4:8) using 40 mm graded crushed stone aggregate as mass concrete and filling of foundation complete all as specified & directed .
M&L for brick work with fly ash brick (old size), straight or curved on plan exc 6 M mean radius, built in cement mortar 1:6 complete all as specified & directed .
M&L for RCC slab culvert (Two Numbers) 7.50 m long and 600 mm depth from inlet level of drain to soffit of slab including parapet, PCC apron ,excavation & earthwork and two coats of colour wash over a coat of white wash as shown on TD drawing No TD-621,Sheet 1/1 complete all as specified & directed .
Excavation over area, not exceeding 1.5 metre deep and getting out in any type of soil complete all as specified & directed .
Excavation in trenches in soft/loose soil not exceeding 1.5 metre depth and n.exc 1.5 metre width for foundation etc or not exceeding 10 Sqm on plan and getting out complete all as specified & directed .
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete including sub base of floors complete all as specified & directed .
M&L for brick work with fly ash brick (old size), straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified & directed .
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified & directed .
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in surface channels and drains complete all as specified & directed .
M&L for returning filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
M&L for removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for 15mm thick cement plaster in CM (1:4) on fair faces of brick wall Pillar and projection surface even and smooth without using extra cement complete all as specified and directed.
Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, coping, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200mm thick, for rough finished flat surfaces of concrete complete all as specified and directed.
Form work to edges of concrete flats, openings, floors and roofs and sides of RCC/PCC bands in wall and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
TMT bars of 10mm dia and over, dia cut to length bent to shape required including cranking bending spirally, hooking ends and binding with mild steel wire not less than 0.9 mm dia(annealed) complete all as specified and directed by Engr-in-Charge. (Note - The payment shall be made only after placing of cover on manholes complete all as specified and directed.
M&L reinforcement cement concrete design mix M-25 (using 20 mm graded stone aggregates) in slabs supported on walls, beams & columns complete (reinforcement to be measured separately) complete all as specified and directed.
Preparing new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of pre cast cover slab of cement (reinforced) of any description and in any position not otherwise specifically complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick surfaces finished even and smooth w/o using extra cement in cement mortar 1:4 complete all as specified and directed.
TMT bars of 10mm dia and over, dia cut to length bent to shape required including cranking bending spirally, hooking ends and binding with mild steel wire not less than 0.9 mm dia(annealed) complete all as specified and directed by Engr-in-Charge. (Note - The payment shall be made only after placing of cover on manholes complete all as specified and directed.
M&L providing precast cover slab RCC 1:2:4 (20 mm graded stone aggregate) type B-1 for manhole/ drain/ chamber cover set in cement mortar 1:6 complete all as specified and directed. Note : Shape of cover slab as per site requirement and as directed by Engr-in-Charge.
Sewage disposal Excavation in trenches, in any kind of soil not exceeding 1.50 meter wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil complete all as specified and directed.
All as per ser item No 175 here in before but exceeding 1.5 metre and not exceeding 3 metre depth complete all as specified and directed.
Returning filling in including spreading levelling, watering and well remming in layers not exc 25cm thick complete all as specified and directed. (Surplus soil if any shall not be removed & left proud over the trench) complete all as specified and directed.
Removing excavated soil n.exc. 50m and deposited where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed.
Demolition by breaking up salt glazed stone ware drain pipes of 150 mm dia jointed in cement mortar and taking out from trenches and preparing the concrete bed wherever required for laying new pipe and removing the debris from site complete all as specified and directed.
Supply and laying salt glazed stone ware drain pipes 200 mm dia (internal ) grade 'A' laid in trenches and jointed in cement mortar 1:1 including testing complete all as specified and directed.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded stone aggregates as in concrete bed to drain pipe of 200 mm bore laid to falls in trenches in any depth including packing under and haunching against the sides of pipes with concrete after the pipes are laid and tested complete all as specified and directed.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded stone aggregates as in concrete bed to drain pipes of 150 mm bore laid to falls in trenches in any depth including packing under and haunching against the sides of pipes with concrete after the pipes are laid and tested complete all as specified and directed.
Supply and laying salt glazed stone ware drain pipes 150 mm dia (internal ) grade 'A' laid in trenches and jointed in cement mortar 1:1 including testing complete all as specified and directed.
Demolition of brick work built in cement mortar incl all quoins, pillers arches etc complete all as specified and directed.
Brick work, with fly ash brick (old size), straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 using old size bricks complete all as specified and directed.
All as per item No 185 above but using old bricks complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including complete all as specified and directed.
PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as in foundation of manhole complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping, benching etc complete all as specified and directed.
M&L for 15mm thick cement plaster in CM (1:4) on fair faces of brick wall surface even and smooth without using extra cement complete all as specified and directed .
Supply only integral water proofing compound (for mixing in cement mortar or concrete) complete all as specified and directed
Demolition of cement concrete reinforced in ground floor and paving n.exc 15 cm thickness below or above the ground level complete all as specified and directed .
TMT bars of 10 mm dia and over, dia cut to length bent to shape required including cranking bending spirally, hooking ends and binding with mild steel wire not less than 0.9 mm dia(annealed) complete all as specified and directed .
RCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in precast slabs for covers of manholes including necessary form work and placing of manholes cover in position ,set in cement mortar 1:6 complete all as specified and directed .
Cutting into existing manholes for connecting internal dia of pipe 150 mm in new drain, making good to pipe and rendering cutting out existing benching for channel (1/2 or 3/4 section) in cement concrete 1 : 2 : 4 type B-1 using 20 mm graded stone aggregate by repairing benching as required complete all as specified and directed .
All as item No 195 above but for removing existing branch drain, making good to walling and rendering, cutting out branch channel, and making good benchings in cement concrete 1 : 2 : 4 type B-1 using 20 mm graded stone aggregate by repairing benching as required complete all as specified and directed .
Construction of RCC septic tank design to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 type D2 using 40 mm graded stone aggregate below foundation ,RCC M-30 design mix in walls, base slab, baffle walls and Roof slab including beams etc with vent shaft, manhole opening with cover construction etc complete with effective depth of 1.5 metre and over all depth of 3 Metre for 100 user complete as shown on TD drawing No 750,sheet 1/2 to 2/2 ,specified and directed .
Construction of RCC septic tank design to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 type D2 using 40 mm graded stone aggregate below foudation RCC M-30 design mix in walls, base slab, baffle walls and Roof slab including beams etc with vent shaft, manhole opening with cover construction etc complete with effective depth of 1.5 mtr and over all depth of 3 Mtr for 50 user complete as shown on TD drawing No 750,sheet 1/2 to 2/2,specified and directed .
Construction of soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, type C-2 using 40 mm graded stone aggregate, wells of Honey combed masonary with top ring of M-25 Concrete, including intercepting chamber, screen chamber made of brick work in CM, RCC cover slab in M-25/ SFRC Cover interconnecting pipe of RCC/DWC complete filled with brick bats of size 2.4 Metre x 6 Metre effective depth complete as shown on TD drawing No 576,sheet No 1/2 to 2/2 ,specified and directed .
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
Taking down existing old/ unserviceable sub main wiring along with fitting/fixtures existing of any type and description, removal of teak wood batten/ PVC pipe/ PVC casing & caping and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified and directed.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and Including rigid PVC conduit medium grade, concealed on wall portion and with stove enamelled steel conduit medium grade on steel structural truss/ RCC roof ceiling portion surface type fixed with saddles, screws as per Engineering practices of suitable size but not less than 20 mm bore with its accessories, to be terminated in and excluding modular metal GI flush box and its cover plates for fixing modular type switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-202 here in before but one light point controlled by two nos 2 way switchs complete all as specified & directed.
All as per item No-202 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the same board with other switches complete all as specified & directed.
All as per item No-202 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-202 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the independent board but below the switch board of light points in same vertical plane complete all as specified & directed.
Supply and fixing modular metal GI flush type termination box of minimum 1.2 mm thick with rust protection 1/2 module as per site requirement suitable for 20 mm dia conduit to be fixed on walls in CM 1:4 and making good the disturbed surfaces of walls as per existing complete all as specified and directed.
All as per item No-208 here in before but modular metal GI flush type termination box of minimum 1.2 mm thick with rust protection of 3 module
All as per item No-208 here in before but modular metal GI flush type termination box of minimum 1.2 mm thick with rust protection of 4 module
All as per item No-208 here in before but modular metal GI flush type termination box of minimum 1.2 mm thick with rust protection of 5 module
All as per item No-208 here in before but modular metal GI flush type termination box of minimum 1.2 mm thick with rust protection of 6 module
All as per item No-208 here in before but modular metal GI flush type termination box of minimum 1.2 mm thick with rust protection of 12 module
All as per item No-208 here in before but modular metal GI flush type termination box of minimum 1.2 mm thick with rust protection box of 18 module
Supply and fix modular white cover plate with frame 1 module for mounting modular switches,sockets and regulators etc complete all as specified & directed .
All as per item No-215 here in before but modular white cover plate with frame 2 module
All as per item No-215 here in before but modular white cover plate with frame 3 module
All as per item No-215 here in before but modular white cover plate with frame 4/5 module
All as per item No-215 here in before but modular white cover plate with frame 6 module
All as per item No-215 here in before but modular white cover plate with frame 2x 6 module
All as per item No-215 here in before but modular white cover plate with frame 3x 6 module
Supply and fix switch modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.
Supply and fix bell push modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.
Supply and fix switch modular type single pole, 6 Amps one module, two way,one way, 230 volts complete all as specified and directed.
Supply and fix socket outlet, 6 Amps, modular type, 2 module 230 volts complete all as specified and directed.
Supply and fix switch modular type, single pole, 16 Amps one module,one way 230 volts complete all as specified and directed.
Supply and fix socket outlet, 2-in1,6/16 Amps, modular type, 2 module 230 volts complete all as specified and directed.
Supply & fix rotory stepped type electronic fan regulator modular type,Single module 120 watt 230 Volts complete all as specified & directed.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed.Make:
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed.
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed.
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including PVC rigid conduit medium grade not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Supply and fix in replacement MCB DB 6 way sheet metal enclosure triple pole and neutral 415 volts with 100 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated Complete suitable for one MCB 4P as incomer & 18 Nos MCB SP as outing and as per IEC 61439 without MCB but with enclosue blank plate complete all as specified and directed .
Supply and fix in replacement MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement Suitable for fixing 01 No MCCB, 4 pole 100 to 125 Amp rating & 12 Nos MCB SP as outgoing , IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed .
Supply and fix in repair MCB DB Sheet metal enclosure suitable for fixing 01 No. MCB/RCCB SPN as Incomer & 06 Nos MCB SP as outgoing, factory fabricated, double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed.
Supply and fix In repair MCB DB Sheet metal enclosure suitable for fixing 01 No MCB/RCCB SPN as Incomer & 02 Nos MCB SP as outgoing, factory fabricated, double door SPN 4 way with 100 amps rated copper rated bus bar 240 volts IP-43, IK-09 complete all as specified and directed.
Supply and fixing In repair miniature circuit breaker (MCB) TPN 40 Amp, 4 poles, 415V 10KA 'C' curve current carrying capacity in the DB IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning complete all as specified & directed.
Supply and fix In repair MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB complete all as specified and directed.
Supply and fixing In repair miniature circuit breaker (MCB) TPN 25 Amp, 4 poles, 415V 10KA 'C' curve current carrying capacity in the DB IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing In repair MCB Two pole 240 volts, 50 Hz, 10 KA ISI marked as per IS/IEC 60898-1 2002, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Supply & fix In repair MCB SP, 16 to 25 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
Supply & fix In repair MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for equipment & power circuit)
Supply & fix In repair MCB SP, 2 to 4 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for light circuit)
Supply & fix In repair, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed.
Supply & fix In repair LED Batten surface/wall mounted with specially designed powder coated aluminium housing,high optically efficient polycarbonate diffuser,in built electronic driver duly wired up to terminal block,power consumption<20W,luminaire lumen >2000 lm,system efficiency of >120 lumens/W,LED with LED binning as per ANSI Bin C78.377A,photo biological safety report as per IEC 624718& electrical insulation class 1 Ingress protection IP 20,clor rendering index CRI> 80 ,temp range 0 to 450 C ,driver efficiency >85% Power factor >0.9 THD <20% as per IEC 61000-3-2 ,color temp -6500K,Surge protection 2.5 KV,50000 burning hrs (min) as per L7O criteria,two stages isolated constant current operated driver with range 150-270 V AC and safety extra low voltage safe level< 60 V DC as per IEC standard with LM70 & LM 80 certification complete all as specified and directed.
S&F in replacement LED security with aluminum pressure die cast housing, high purity PC fresneldiffuser with silicon gaskets for IP-65 protection, power consumption < 30 W and system efficiency > 100lm /W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35 mm LED , CRI > 70, ambient temprature range 0-450c, THD<10%, colour tempreature 5700 K, surge protectionin cm 3.5KV 50000 burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low volatge safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall complete all as specified & directed .
S & F in replacement LED light fitting 1x9 W/1X10 W bulkhead luminaires including LED light driver holderconnecting up with three core flexible copper conductor cable, power consumption < 10 W and system efficiency > 100lm /W, of suitable size complete all as specified & directed.
S&F for 2 ft x 2 ft recess mounted full panel LED luminaire with white powder coted housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser, in built electronic driver duly wired upto terminal block, power consumption< 35 W, luminaire lumen > 3500lm and system efficiency > 120lm/w, CRI> 80, LED with LED binning as per ANSI Bin C78.377A, Photo biological safety report as per IEC624718 & electrical insulation class 1 , colour temp- 5700k, Ingress protection IP20, Driver efficiency > 85% , 50000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor > 0.95 THD <10%, surge protectionin CM-3KV, two stage isolated constant current operated driver with range 150-270V AC and safety extraa low voltage safe level < 60V DC as per IEC standard, with LM79 & LM80 certification complete all as specified & directed .
Supply and fixing in replacement Round shape down lighter to be fixed in false ceiling 12/15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed.
Supply and fixing in replacement square slim mounted LED luminaire 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed.
Supply laying and testing in replacement, cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed.
Supply laying and testing in replacement, cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and directed.
Supply & Laying,testing , in replacement, cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 50 Sqmm 3.5 core compele all as specified and as directed.
Supply & Laying,testing , in replacement, cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 25 Sqmm 4 core compele all as specified and as directed.
Supply & Laying,testing , in replacement, cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 70 Sqmm 3.5 core compele all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified & directed .
Removal of excavated material n.exc 50 metre away and depositing where directed at a level n.exc 1.5 metre above from starting point complete all as specified & directed .
Supplying and laying un-reinforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified & directed .
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as specified & directed .
Supply and fixing in replacement, GI Pipe 40 mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed .
Supply and fixing in replacement, GI Pipe 50 mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed .
Supply and fix ceiling fan, 1200 mm sweep, minimum 220 CFM, 230 V, BEE 3 star rated, BLDC (brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.
S&F iron metal body heavy duty exhaust fan 300mm sweep, double ball bearing, copper wound, with louvers/shutter, 230 volts, 50 Hz, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.
Supply and fixing 70 watt ,230 V AC outdoor type 5700K LED security Flood light made out of pressure die cast aluminium housing with toughened glass , IP-66 protection and impact resistance IK-07 ,mounted on top of the pole/bldg with fixing bracket having length not less than 0.5 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for high lighting objects/ shine boards fixing on building, including electrically connecting with PVC insulated three core 0.5 Sqmm strandard copper conductor 3 core flexible cable cord from celling rose to light fittings connecrtor complete all as specified and directed.
Supply, Installation, commissioning & testing of double doom (main dome & satellite dome) Shadow less LED operation threator (OT) light suitablefor providing shadow control i.e vertically eliminates, distracting shadows from surgens head & hands,Adavace technology, offer cool bright white light so surgeons stay comfortable even under the most demanding conditions, Accurate colour radiation for discerning suitable differences in exposed tissue, Double dome fully counter balanced moveable on ceiling trolley having a minimum longitudinal travel of 1350 mm and 360-degree rotation of the LED OT Light from the central axes and revolving, field focusing controlled by Sterilisable handle (Dual control manual & remote) present at the centre of the dome to adjust the focus of the light, which provides an excellent spot diameter between 130 - 300 mm, USA Core Plate for narrowing the focus beam, Excellent focusing and cold light effect, LEDs shall be of German OSRAM LED's makes, LED service life >50,000 hours working life, Three different modes of surgeries (ENDO mode, Surface mode and Deep Cavity), both dome LED lights having luminous intensity of 160000.00 lux (adjustable feild diameter of both the domes 14 to 38 Cm through control panel), colour tempreture shell be 4300 ± 500 K, Lighting Depth ≥1250 mm, Dimming Control 08 Shift Scales, CRI ≥96(Ra), depth of illumination (1+12 Cm) shall be > 100, colour rendering index 95+3%, intensity control 25-100%, light should have dual control ( manual & remote control) complete system should be operated at 220 to 230 volts, 50 Hz, AC supply supply, having power consumption < 150 watts, each dome having 48 Nos of LEDs complete all as specified and directed.The system should have following additional features:- (i) Red Toning colour enhancement for tissue visualization (ii) Camera ready option for future integration of the camera (iii) Variable colour temperature and red toning option (iv) Emergency power unit & battery backup for minimum 30 minutes of capacity (2.4 KW) 3.0 KVA, complete all as specified & directed by Engr-in-Charge at site.
M&L for earthing in replacement complete with galvansided steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50 metre below the normal ground level, GI wire 4.0 mm dia from earth plate/ electrode to test point (upto max distance of 7.50 metre is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15 mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20 mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade stone aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade stone aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50 mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8 mm TMT bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and connection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed.
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repare/ servicing & painting with one coat of synthetic enable paint and writing of MES/identification No. of fans and re hanging/ re-fixing in original position but including replacement of three cor flexible copper conductor cable from ceiling rose to fan connector block of size 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as specified and directed.
Taking down cement plaster in any cement mortar on stone wall including deep (minimum 15 mm from brick surface) racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L applying two coats of water proofing coating with authorized applicators on brick or concrete surfaces complete all as specified and directed (Make of water proofing coating Smart care damp block 2K of Asian paints or Equivalent) complete all as specified and directed.
M&L for rendering (internal plaster)10 mm thick cement and coarse sand 1:4 with guiniting machine pressure capacity not less than 5 Kg per Sqcm on fair face of brickwork or concrete surfaces complete all as specified and directed.
M&L for rendering (external plaster)10 mm thick cement and coarse sand 1:3 with guiniting machine pressure capacity not less than 5 Kg per Sqcm on surface other than fair face of brick work or concrete surfaces complete all as specified & directed .
M&L half brick work with flyash brick straight or curved on plan to any radius built in CM 1:4 complete all as specified & directed .
M&L for rendering 5 mm thick in CM 1:3 with water proofing compound @2% by weight of cement or as per manufacturer's instructions on fair face of brickwork or concrete surfaces complete all as specified & directed . Note:- WPC shall be measured & paid separately under respective items.
S&F in repairs drapery rod 25 mm dia ,high strength stainless steel ‘304’ grade curtain rod with decorative stainless steel ornamental attachment (side knob) at both ends and one set of ornamental decorative stainless steel clamps (bracket) and matching curtain rings minimum 8 Nos in one running meter complete all as specified and directed.
M&L for rubbing and mirror polishing of existing kota stone flooring and skirting complete all as specified and directed.
S&F in repairs ,PVC kitchen frame of section 18x75 mm made out of 18 mm thick PVC ply sheet of pleasing colours, print and prelam finishes one side as approved and frame shall be fixed with & including plastic fasteners and 50 mm long steel screws inside by using drilling complete all as specified and directed.
S&F in repairs ,PVC kitchen shutters made out of 18 mm thick PVC ply sheet of pleasing colours, print and prelam finishes one side as approved and kitchen shutters shall be fixed to the PVC kitchen frame & including auto hinges ,steel screws and modular handles complete all as specified and directed.
S&F 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of wall care putty of 1mm thick on old decorated surface including complete removal of existing treatment complete all as per specified and directed.
Preparation of newly plastered wall surfaces and applying two coat of cement base paint over a coat of primer complete all as per specified and directed.
Preparation of newly plastered wall surfaces and applying two coat of distemper oil emulsion over a coat of wall putty complete all as per specified and directed.
S & F 15mm bore dia elbow operator quarter turn taps fancy type cast copper alloy with deck mount installation type suitable for hospitals, laboratory etc screwed for iron pipe and fixed complete all as specified and directed.
Cutting chases on brick wall, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10cm girth complete all as specified & directed .
S&F brass chrome plated jet spray nozzle with necessary brass nut and rubber washers complete all as specified and directed.
M & L earthing complete with copper earth plate electrode of size 600 x 600 x 3 mm, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including copper strip of size 25x3mm as earth lead by means , including 40 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Loose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, complete all as specified as per electrical plate no:3 of SSR part-1 & directed .
M&L for copper strip 25 x 3mm for loop earthing or upto machinery/ equipments termination point buried in ground with 40 mm GI light grade protection pipe or fixed on wall with PVC/ porcelain insulators, screws, plug & gutties for upper/down conductor complete all as specified and directed. Note:- Item shell be executed if required at site beyond 7.5 M main earthing lead.
Supply & fixing in repairs single phase motor starter switch 25 Amp, 240 Volts, 50 Hz, AC supply suitable for AC operation modular type, 2 module complete unit enclosed in single one polycarbonate housing of white/ black shed modular flush type having inlet & outlet cable ports suitable for AC operation of capacity 1.5/2.0 TR complete all as specified and directed.
Supply & fix PVC blanking plate one module suitable for fixing in blank way of MCB DBs complete all as specified & directed.
S&F, RCCB, 2P, 16 Amp rating, 6 KA, Sensitivity, 100 mA, confirming to IS 12640-1 & IEC 61008-1, 240 volt, 50 Hz, AC supply suitable for fixing in MCB DB SPN as in Incomer complete all as specified and directed.
S&F, RCCB, 2P, 40 Amp rating, 6 KA, Sensitivity , 100 mA, confirming to IS 12640-1 & IEC 61008-1, 240 volt, 50 Hz, AC supply suitable for fixing in MCB DB SPN as in Incomer complete all as specified and directed.
S&F RCCBO 4P, 40 Amp rating, 10 KA, Sensitivity 100 mA, 415 Volt, 50 Hz, AC supply confirming to IS 12640-1 & IEC 61008-1 suitable for fixing in MCB DB TPN as in Incomer complete all as specified and directed.
S&F RCCBO 4P, 63 Amp rating, 10 KA, Sensitivity 100 mA, 415 Volt, 50 Hz, AC supply confirming to IS 12640-1 & IEC 61008-1 suitable for fixing in MCB DB TPN as in Incomer complete all as specified and directed.
Supply and fix PVC body fresh air fan of size 200 mm sweep, with PVC louvers, operated at 230 Volts 50 Hz, AC supply, 1350 to 1400 RPM with 3 core flexible copper conductor cable cord of size 0.75 Sqmm from fan to ceiling rose complete all as specified and directed.
Supply & fix in reapirs multi socket outlets modular type board consisting of GI pressed steel sunken flush type box, modular white plate and cover plate suitable for and including housing 02 Nos 6 pin 16 & 6 Amps modular type each sockets controlled by one 16 Amps switch and 04 Nos 5 pin 6 Amps each sockets controlled by 1 way 6 amps switch modular type and 01 No. power indicating lamp complete box should be flush to wall complete all as specified and directed.
Disconnecting, dismantling &taking down carefully medical grade copper pipe line of size 12 mm to 28mm including fitting &fixtures of copper and keeping in safe custody for re-fixing in position after repair/ maint of wards at site including replacement damaged fittings & fixtures of pipe line (such as bends, elbow, tee, plug, PVC saddles etc) complete all as specified and directed.
Disconnecting, dismantling & taking down carefully medical grade Oxygen gas outlet point probe confirming to DIN type and re-fixing in position after repair/ maint work of bldg. and testing complete all as specified and directed.
Disconnecting, dismantling & taking down carefully of Bed Head panel of approximate size 300 mm x 900 mm consisting of 2 Nos oxygen outlet port, 04 Nos switch socket outlet complete and keeping in safe custody and re-fixing in position after laying of pipe lines complete all as specified and directed.
Disconnecting, dismantling & taking down carefully of Medical Gas alarm Panel (Analog type) for 1 gas service and keeping in safe custody and re-fixing in position after work of wards complete all as specified and directed.
Disconnecting, dismantling & taking down carefully of manually operated panel for oxygen manifold system of any capacity/ type and keeping in safe custody of users including re-fixing in position and testing on completion complete all as specified and directed.
Disconnecting, dismantling & taking down carefully of semi automated panel for oxygen manifold system of any capacity/ type and keeping in safe custody including re-fixing in position and testing on completion complete all as specified and directed.
Disconnecting, dismantling & taking down of OD medical line valve or isolation valve of size 12 mm to 28 mm bore by descrewing carefully and keeping in safe custody and re-fixing in position after laying oxygen pipe line properly with leak proof jointing in position as per user requirement at site complete all as specified and directed.
All as per item No 306 above but copper pipe of size 15 mm OD and 0.9 mm thickness complete. Make:- Maxflow/ Mandev/Rajco
All as per item No 306 above but copper pipe of size 22 mm OD and 0.9 mm thickness complete. Make:- Maxflow/ Mandev/Rajco
All as per item No 306 above but copper pipe of size 28 mm OD and 0.9 mm thickness complete. Make:- Maxflow/ Mandev/Rajco
Supply, installation, commissioning & testing of 12 mm OD medical line valve or isolation valve as per CE certified / HTM-2022/02-01/DIN/ISO/BS EN 1057 as per BS1057, rated at 400 Psig as well as full vaccume (29.9" Hg) valves go from full ON to full OFF by turning the vinylgripped valve handle 90 degree locking type handles and copper tubing is factory installed to pravent valve seat damage during soldering and connection to copper pipe complete all as specified and directed. Make :- CONEX /RB/RN/SIM/AUDCO/AKTIV
All as per item No 310 above but valve size 15 mm OD complete all as specified and directed.
All as per item No 310 above but valve size 22 mm OD complete all as specified and directed.
All as per item No 310 above but valve size 28 mm OD complete all as specified and directed. NOTE FOR ITEM NO 1 TO 313 OF BOQ :- Please note that, if two or more items of similar description given in BOQ then only lowest rate shall be applied & paid to the contractor as work proceed.
M/s Allied Traders
VEE SONS BUILDERS PVT LTD
m/s meetu enterprises
Shree Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid