Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical AT DHORI STAFF QTR PO DHORI DIST BOKARO | - | Rejected-Technical L3 | |
| 3 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
Refer Docs
EMD Value
₹5,900
Closing Date
21 Aug 2024, 6:55 pmClosed
PE EnM dhori khas
PE EnM dhori khas
Repairing, maintenance and overhauling of different switch gears /starters attached with different pumps, MMV and Haulages
2024_CCL_314396_1
PO/D(K)/EnM/Tender/24-25/08
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
PE EnM dhori khas
As per NIT
2 documents required · 2 mandatory
₹5,900
29 Aug 2024
6 Aug 2024
22 Aug 2024
7 Aug 2024
21 Aug 2024
7 Aug 2024
7 Aug 2024 - 14 Aug 2024
Amount
R/M of Star Delta Starter (200 A, 550 V) for smooth operation of pump
Providing and fixing of Contactor ML10, 550V
Providing and fixing of Earth leakage relay 110 volt ,delay Sec 0.1-1 sec, amp range 0.1 Amp-0.75 Amp
Providing and fixing of Amp meter Round type 2” 0 to 200 Amp
Providing and fixing of push switch elements (red+green)
Providing and fixing of P.T. 550V/ 220V /110V Transformer
Providing and fixing of Timer relay
Rectification of control circuit wiring including some materials as ferules wire, lugs, clips socket, wiring belt etc.
Complete cleaning/petrol wash unit and double coat colour of starter
Supervision & incidental over-head expenses cost of sl no 1.01 to 1.08
R/M of Star Delta Starter (200 A, 550 V) for smooth operation of pump
Providing and fixing of Contactor kit ML12, 550 V
Providing and fixing of Contactor coil ML12, 550V
Providing and fixing of Isolator set repair
Providing and fixing of Earth leakage relay 110 volt ,delay Sec 0.1-1 sec, amp range 0.1 Amp-0.75 Amp
Providing and fixing of CBCT 110volt for earth leakage relay
Providing and fixing of Timer relay
Rectification of control circuit wiring including some materials as ferules wire, lugs, clips socket, wiring belt etc.
Providing and fixing of CT for Overload relay 200/5.
Complete cleaning/petrol wash unit and double coat colour of starter
Supervision & incidental over-head expenses cost of sl no 2.01 to 2.09
R/M of Star Delta Starter (200 A, 550 V) for smooth operation of pump
Providing and fixing of Contactor kit ML 12, 550V
Providing and fixing of Contactor coil ML12, 550V
Providing and fixing of Earth leakage relay 110 volt ,delay Sec 0.1-1 sec, amp range 0.1 Amp-0.75 Amp
Providing and fixing of push switch elements (red+green)
Providing and fixing of CBCT 110volt for earth leakage relay
Providing and fixing of Over Load relay 0-200 Amp, thermal type
Rectification of control circuit wiring including some materials as ferules wire, lugs, clips socket, wiring belt etc.
Complete cleaning/petrol wash unit and double coat colour of starter
Supervision & incidental over-head expenses cost of sl no 3.01 to 3.08
R/M of DOL Starter (150 A, 550 V) for smooth operation of Haulage
Providing and fixing of Contactor ML10, 550V
Rectification of control circuit wiring including some materials as ferules wire, lugs, clips socket, wiring belt etc.
Providing and fixing of incoming and outgoing bushing with stud 1.1KV grade
Providing and fixing of Over Load relay 0-150 Amp, Thermal Type
Complete cleaning/petrol wash unit and double coat colour of starter
Supervision & incidental over-head expenses cost of sl no 4.01 to 4.05
R/M of DOL Starter (150 A, 550 V) for smooth operation of Haulage
Providing and fixing of Isolator
Providing and fixing of incoming and outgoing bushing with stud 1.1KV grade
Providing and fixing of Earth leakage relay 110 volt ,delay Sec 0.1-1 sec, amp range 0.1 Amp-0.75 Amp
Providing and fixing of CBCT 110volt for earth leakage relay
Providing and fixing of Amp meter Round type 2” square 0 to 200 Amp
Providing and fixing of push switch elements (red+green)
Providing and fixing of P.T. 550V/ 220V /110V Transformer
Providing and fixing of CT for O/load relay
Rectification of control circuit wiring including some materials as ferules wire, lugs, clips socket, wiring belt etc.
Providing and fixing of Over Load relay 0-150 Amp, Thermal Type
Complete cleaning/petrol wash unit and double coat colour of starter
Supervision & incidental over-head expenses cost of sl no 5.01 to 5.11
Total impact of GST for the purpose of CTC
S K ELECTRICALS WORKS
M/s Arvind Kumar Singh
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .