Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC tender accepted | |
| 2 | L2₹15.7 L+₹25,160 (1.62%)Rejected-Finance | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹15.9 L+₹43,295 (2.80%)Rejected-Finance | L3 | Rejected-Finance not being L1 | |
| 4 | L4₹16.0 L+₹50,172 (3.24%)Rejected-Finance 96 1 HIMMATGANJ BEHIND UNANI MEDICAL COLLEGE PRAYAGRAJ 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L4 | Rejected-Finance not being L1 | |
| 5 | L5₹16.5 L+₹1.1 L (6.80%)Rejected-Finance | L5 | Rejected-Finance not being L1 |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
11 Jun 2021, 6:00 pmClosed
GE Faizabad
GE MES Faizabad
REPAIR MAINT OF PUMP PANELS CLEANING OF UG SUMP AND OH RESERVOIRS AND ALLIED WORKS UNDER AGE EM AT GE FAIZABAD
2021_MES_439045_2
8204/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Faizabad
₹32,000
Yes
30 Jul 2021
1 Jun 2021
12 Jun 2021
1 Jun 2021
11 Jun 2021
4 Jun 2021
Amount
Cleaning of RCC overhead reservoirs internally of capacity 100000 gallons on upto 21 metre high staging including removing deposits, sand etc from inside the tank, scrubbing and washing side walls and bottom of inside tank with bleaching powder solution and making surface free from any fungus/ algae/ vegetation, filling of cavities inside of tank with cement mortar 1:3 mixed with quick settling chemical and applying one coat of white wash inside dome.Writing date of cleaning outside the tank complete all as specified and directed including cleaning of wash out system as required for proper flushing out of dirts/ deposits of over head tank. [Note :- (i) All type of T&P and Labour etc shall be arranged by the contractor and rate for the same deemed to be included in the quoted rate. (ii) Contractor will dispose off the material taken out from the installation at appropriate location upto 50 metre as directed by Engr-in-Charge]
All as per Item Ser No 01 above but RCC OH reservoir of capacity 50000 gallons complete all as specified and directed
Cleaning of Under Ground Sump internally as well as externally of capacity upto 10000 gallons after pumping out of residual water including removing deposit, sand from inside the sump, scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus/ algae/ vegetation, filling of cavities inside and outside of tank with cement mortar 1:3 mixed with quick settling chemical and applying one coat of white wash inside including top side & writing date of cleaning outside complete all as specified and directed. [Note :-(i) All type of T&P including portable non-clog pump for pumping out residual water before cleaning and Labour etc shall be arranged by the contractor and rate for the same deemed to be included in the quoted rate. (ii) Contractor will dispose off the material taken out from the installation at a distance upto 50 metre as directed by Engieneer-in-Charge.]
M&L for applying two coats of cement based paint on all external surface of overhead reservoir of capacity 100000 gallons including coulmns and beams of staging up to 21 metre high after scraping/ preparing of old surfaces and two coats of synthetic enamel paint on Inlet, outlet, overflow and washout CI/ GI/ DI pipes and complete staircase as per existing colour from ground level up to top of the reservoir complete all as specified. [Note: - (i) Before applying cement paint, the surface shall be thoroughly wetted to control surface suction (ii) Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used]
All as per item No 4 above but for overhead reservoir of capacity 50000 gallons
M&L for applying two coats of synthetic enamel paint on Inlet, outlet, overflow and washout CI/ DI pipes and sluice valves and staircase as per existing colour from ground level up to top of the reservoir of capacity 100000/50000 gallons on upto 21 metre high staging after preparing of old surfaces complete all as specified and directed by Engineer-in-charge. [Note: - (i) Different colour for inlet, outlet, wash out, overflow, valves shall be applied as per standard colour code and cost of the same deemed to be included in the quoted rate.]
M&L for applying two coats of synthetic enamel paint on CI/ DI pipes of distribution header including sluice valves of various pump houses after scraping/ preparing of old surfaces complete all as specified .
M & L for removing honey comb grown on outer surface of RCC overhead reservoirs of capacity 100000/ 50000 gallons on upto 21 metre high staging and applying two coats of cement based paint on the affected area duly matching with the existing colour complete all as specified and directed by Eng-In-Charge. [ Note:- The work shall be carried out by professionals and department will not take any responsibility in case of casuality caused by honey bees.]
S&F self reflector type flexi board with PVC frame of size 1.2mx0.8m including diagram of water disribution network at each pump house complete all as specified .
Supply only Liquid O-Tolidine solution in sealed bottle of 500 ml complete all as specified
Supply only sodium hypochloride liquid (chlorine content 10%) duly packed in sealed drum of make: M/s Declibac/ M/s Rayalshima Enterprise/ Birla Chemicals or equivalent as approved by GE complete all as specified
Supply only lead acid battery 12 volt 180 Ah including initial charge of ,complete all as specified . Make: Exide / Amaron/ Inva Tubular
M&L for Rolled mild steel in Joist ,channel,angle, or tee sections, fixed independently, without connecting plates, etc. for repair to staircase, hand rails and back rest of over head reservoir or as otherwise, complete all as specified . [Note: All T&P and labour charges for working on OH tanks upto 21 metre high staging deemed to be included in the quoted rate]
M & L for connecting Aviation light of capacity 20 watt on top of overhead reservoir upto 21 metre high staging including taking out of old one make: Bajaj / Havellsor equivalent as approved by GE,complete all as specified . [Note: All T&P and labour charges for working on OH tanks upto 21 metre high staging deemed to be included in the quoted rate]
M & L for Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured with clamps or as ordered for guarding lightning conductor and cable for aviation light along the pillars upto top of over head reservoir at a height of upto 21 metre, complete all as specified . [Note: All T&P and labour charges for working on OH tanks upto 21 metre high staging deemed to be included in the quoted rate]
M & L for Aluminium strip 25mm x 3 mm with saddles and fixing screws or fixing arrangement as per sitte requirement etc. for roof conductors and down conductors above ground along the pillars upto top of over head reservoir at a height of upto 21 metre including taking out of old strips ,complete all as specified . [Note: All T&P and labour charges for working on OH tanks upto 21 metre high staging deemed to be included in the quoted rate]
M & L for Air termination, single pointed aluminium rod 12mm dia and 300mm long for fixing on top of overhead reservoir at upto 21 metre height including taking out of old one ,complete all as specified . [Note: All T&P and labour charges for working on OH tanks upto 21 metre high staging deemed to be included in the quoted rate]
M & L for Rigid non-metallic PVC conduit of 40 mm OD exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc along the pillars upto top of over head reservoir at a height of upto 21 metre ,complete all as specified .. [Note: All T&P and labour charges for working on OH tanks upto 21 metre high staging deemed to be included in the quoted rate]
M & L for PVC insulated and sheathed flat twin core multistranded aluminium conductor of nominal cross sectional area 6.0 sqmm for connecting Aviation light fixed on top of overhead reservoir at upto 21 metre high staging including taking out of old one ,complete all as specified . [Note: All T&P and labour charges for working on OH tanks upto 21 metre high staging deemed to be included in the quoted rate]
M & L for Tubes, light grade, galvanised 25 mm , with all fitting, laid in trenches for protection of LT cables, complete all as specified .
Excavation in trenches n.exc. 1.5 metre wide and n.exc. 1.5 metre in depth for laying submersible cable in soft/loose soil, taking out excavated material, forming bottom etc ,complete all as specified .
Returning filling in including,spreading ,levelling watering and well ramming in layer in n.exc 25 cm in soft/lose soil ,complete all as specified .
Removing excavated material n.exc to a distance 50 metre and depositing where directed at a level n.exc 1.5 metre above starting point as in soft/loose soil ,complete all as specified .
M & L for Hose box made of 18 gauge MS Sheet with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside for yard hydrant (suitable for housing 2 Nos Hose reel drum for 36 m long hose of size not less than 800mm X 600mm X 250mm) including taking out of old one ,complete all as specified .
S & F Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short including taking out of old one ,complete all as specified .
S & F Hose Reel Drum of size 30 mtr in length of fire fighting system complete along with jointer including taking out of old one all as specified and as directed Engineer-in-charge .
Supply only following medicines/items for First AID Kit Box all as bellow (i) 1 Burnol tube (ii) 2 Soframycine Cream (iii) 1 Dettol liquid 100ml (iv) 5 Pulse Oximeter (v) 1 Pc Sterlile Wound Dressing (vi) 2 Strip Paracetamol (vii) 3 Electrol Sachet (viii) 3 Sanitiser 200ml (ix) 1 Pc Razor (x) 1 Pc Scissor (xii) 15 Pcs Adhesive Bandage (xiii) 3 Pc Heavy Crepe Bandage width 7.5x3 cm etc
M&L for rectification of leakage from 80mm bore GI Pipe line joints including excavation, returning and filling etc incl fittings like unions, sockets, bends, elbows, tees, nipples etc as required complete all as specified .
All as per item no. 28 but for 50mm bore GI Pipe
All as per item no. 28 but for 40mm bore GI Pipe
All as per item no. 28 but for 25mm bore GI Pipe
All as per item no. 28 but for 20mm bore GI Pipe
M&L for rectification of leakage from 250mm bore CI Pipe line of joints incl excavation in mud/soil and coucking with pig lead , returning filling complete all as specified.
All as per item no. 33 but for 150mm bore CI Pipe
All as per item no. 33 but for 100mm bore CI Pipe
All as per item no. 33 but for 80mm bore CI Pipe
M&L for replacing of gland packing,nut-bolts and washer of 80mm bore sluice valve complete all as specified.
All as per item no. 37 but for 100mm bore sluice valve.
All as per item no. 37 but for 150mm bore sluice valve.
M&L for replacing of gun metal check nut of 80mm bore sluice valve complete all as specified.
All as per item no. 40 but for 100mm bore sluice valve.
All as per item no. 40 but for 150mm bore sluice valve
M&L for replacing of existing size gun metal spindle of 80mm bore sluice valve complete all as specified.
All as per item no. 43 but for 100mm bore sluice valve
All as per item no. 43 but for 150mm bore sluice valve
M&L for construction of valve pit of size 1050x1050x1050mm (internal dimensions) with brick work in cement mortar 1:4 using sub class 'B' bricks, internal plaster 15mm thick in CM 1:4, coping 40mm thick in PCC 1:2:4, PCC in base and under foundation 75mm thick in PCC 1:3:6, MS angle iron frame using angle of size 35x35x5mm , MS plate cover using 8mm thick sheet and looking arrangements including painting steel surafces with two coats of synthetic enamel paint over a coat of red oxide primer including excavation and earth work complete all as specified and directed including demolition of existing.
All as per item no. 46 but internal dimention900x900x900mm .
All as per item no. 46 but internal dimention650x650x650mm .
S&F in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA, lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified . (Make :- L&T Cat No.CM90642OONO or equivalent to Legrand/C&S as approved by GE.)
S & F On load Changeover 4 pole 100 Amp, 415 volt, open execution type Cat No: CO11000OOOO of make: L&T or equivalent as approved by GE in existing panel including taking out of old one ,complete all as specified .
S & F On load Changeover 4 pole 200 Amp, 415 volt, in Sheet Steel Enclosure type Cat No: CO22000OSOO of make: L&T or equivalent as approved by GE ,complete all as specified .
M & L for 3 pole power contactor 220 volts with 50 Amp AC3 duty rating MNX-50 including auxillary switch of make: L&T, type ML-4, Cat No CS97075 or equivalent in Schneider/ Siemens as approved by GE in existing panel including taking out of old one ,complete all as specified .
S & F Single phase Preventer Relay with adjustable time delay 30 sec to 5 min suitable for 415 volt AC, SPPR type, Cat No: XM81809OOOO of make: L&T or equivalent as approved by GE including internal wiring from switchgear to relay in existing panel ,complete all as specified .
S & F digital type Voltmeter with LED display suitable for 3 phase with accuracy class 1 Cat No: WL132010OOOO of make: L&T Nippon or equivalent as approved by GE in existing panel including taking out of old one ,complete all as specified .
S & F digital type Ammeter with LED display suitable for 3 phase with accuracy class 1 Cat No: WL131010OOOO of make: L&T , Nippon or equivalent as approved by GE in existing panel including taking out of old one all as ,complete all as specified .
S & F tape wound ring type Current Transformer suitable for Bar primary of rating 100/5 Amp, burden 5 VA of make: Kappa/ Matrix or equivalent as approved by GE in existing panel including taking out of old one ,complete all as specified .
M&L for Indicator lamp LED type (R,Y,B) complete with bakelite fuse complete all as specified . Make: L&T/KEYCEE as approved by GE
Disconnecting electrically incomming and outgoing LT UG cable of LT panel of any size and replace burn/unsv suitable size of aluminium bus bar, Welding work for hinches and doors, fixing the locking arrangement including scraping outdoor/indoor side of LT Panel and one coat of redoxide, two coat of synthetic enamelled seimens gray spray of outdoor/Indoor side and reconnecting LT UG cable with fixing aluminium lugs by using crimping tool, nut, bolt washer etc and all necesary work required for smooth functioning of LT panel ,complete all as specified .
M&L Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 meters deep below normal ground level, connected with and including galvanised iron strip of size 25 x 4mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion ,complete all as specified .
Supply & fixing LED street light fitting 100W Rectangular LED Flood Light with innovative thermal management and available in multiple optics and equipped with IP66 protection with required connection wire multistand 2.5 Sqmm twin core sheathed weather proof up to ACSR conductor/ Ceiling rose ,complete all as specified . Make:- Cromption cat pat No:- LFLN-100-CDL/60 or Equvalent of Bajaj/Philips/Havells as approved by GE.
S&F FR PVC insulated Single core unsheathed industrial Flexiblle cable of size 16Sqmm conforming to IS 694 2010 with bright annealed copper conductor in existing panel including taking out old one ,complete all as specified .. Make : Polycab or eqivalent as approved by GE .
His And Her Enterprises
Stoneage
M/S Shiv Ballabh Mishra
M/S ATUL CONSTRUCTION
Shivagya Engineering
M/S A P CONSTRUCTION
Hi-Tech Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .