Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.6 LAccepted-AOC INDEX NO B 132 HQ ADG P CHENNAI NO 229 ANGAPPAN STREET MITTANAMALLI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being L1 tenderer | |
| 2 | L2₹87.0 L+₹8.4 L (10.7%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer. | |
| 3 | L3₹96.5 L+₹17.9 L (22.8%)Rejected-Finance 203 1 THIRUMATHI SUNDARI ILLAM CHINNAMMEN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L3 | Rejected-Finance Being other than lowest tenderer. | |
| 4 | Rejected-Technical | - | Rejected-Technical Not meeting eligibility criteria |
Tender Value
₹92 L
EMD Value
₹2.6 L
Closing Date
22 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
87627E8 PROVN OF COMPRESSED AIR DISTRIBUTION NETWORK UNDER GE AVADI CHENNAI.
2021_MES_431672_1
87627E8 PROVISION OF COMPRESSED AIR DISTRIBUTION N
Open Tender
Construction Works
Item Rate
270 days
AVADI CHENNAI
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AVADI CHENNAI
₹2.6 L
Yes
4 Jun 2021
18 Mar 2021
24 Apr 2021
18 Mar 2021
22 Apr 2021
8 Apr 2021
18 Mar 2021 - 1 Apr 2021
60 days
Amount
BOQ UPLOADED ON 18 MAR 2021
SCH "A" PART-I (CIVIL WORKS)
Surface excavation not exceeding 30 cm deep averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for foundation and getting out in any type of soil complete all as specified and as directed.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and as directed.
Surface dressing not exceeding 15cm deep in hard / dense soil complete all as specified and as directed.
Filling under floors using soil spreading and levelling in layers not exceeding 25cm thick and well ramming including watering and consolidation complete all as specified and as directed.
Approved as excavated vide BOQ Sl Item No.4.00 and 5.00 shall be used under this item.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Removing excavated soils to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Hardcore of gauge not exceeding 63mm of broken stone aggregate, deposited, spread and levelled in layers not exceeding 150mm thick, watered and rammed to a true surface complete all as specified and as directed.
Treating the bottom and sides of excavation at the rate of 5 litres of ATT emulsion 20 EC per square metre of surface area complete all as specified and as directed.
Treating the backfill in contact with foundation at the rate of 7.5 litres of ATT emulsion 20 EC per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
Treating the top surface of filled earth at the rate of 5 litres of ATT emulsion 20 EC per square metre of surface complete all as specified and as directed.
Treating the soil under plinth protection at the rate of 5 litres of ATT emulsion 20 EC per square metre of surface area complete all as specified and as directed.
Treating the soil alongwith external perimeter of building at the rate of 2.25 litres of ATT emulsion 20 EC per metre of the perimeter wall complete all as specified and as directed.
Plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Plain cement concrete, type B1, 1:2:4, using 20mm graded stone aggregate as in bed blocks and the like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and as directed.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in cills including weathering, slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified and as directed.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in plinth beam, footing, bases of columns etc., complete all as specified and as directed.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, shelves and the like complete all as specified and as directed.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in chajjas complete all as specified and as directed.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in beams, lintels over 1.5m span complete all as specified and as directed.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in columns, pillars etc., complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, plinth beams and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, shelves and similar work not exceeding 200mm thick (horizontal or sloping) rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to chajjas and similar items including edges rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor / roof beams and similar items including edges rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to fins, louvers, fascia rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides of columns, pillars and similar work; square, rectangular or polygonal rough finished surfaces of concrete complete all as specified and as directed.
Brickwork with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of designation 50 complete all as specified and as directed.
Brickwork with fly ash bricks, old size, of designation 50, straight or curved on plan to any radius in half thick brick walls built in cement mortar 1:4 complete all as specified and as directed.
Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed.
Mild steel TMT bars 6mm to 8mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed.
Mild steel TMT bars but 5mm dia and over upto and including 10mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers & binders complete all as specified and as directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors and similar work conforming to Fe-290, Gde-E-65 complete all as specified and as directed.
Mild steel as in small articles such as bands, straps, clamps, hold fast and like conforming to Fe-290 Grade-E-165 complete all as specified and as directed.
Steel rolling shutters, with and including suitable ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of red oxide zinc chrome primer, erected in position as indicated, complete, gear operated type with bevel gear box and crank handle 1.25mm lath thickness complete all as specified and as directed.
Anodised aluminium frame for doors, windows, ventilators with one or more rebates including ioining cleat for fixing etc. powder coated to minimum 50 micron thickness complete all as specified and as directed.
Supply only anodised aluminium window and ventilator shutters, side hung type without sash bar, including anodised aluminium shutter sections and anodised aluminium snap beading, ioining cleats, glazing clips etc., powder coated to minimum 50 micron thickness complete all as specified and as directed.
(a) Rubber packing, screws etc. as required shall be measured fixing of shutters.
(b) Glass or wire cloth as required shall be measured and paid separately.
Fixing only anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary ioining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, and provision of anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.) , aluminum tower bolt 125mm (02 Nos) etc., complete all as specified and as directed.
(a) All aluminium sections including snap beading, joining cleats, glazing cilps etc. shall be measured under aluminium shutters separately as supply only.
(b) Glass or wire cloth as required shall be measured and paid separately.
(c) The fixtures given are for shutter of approximate size 0.50m x 1.50m.
Supply and fabricate powder coated, anodised aluminium sections as in cupboards with suitable two track section for frame and sections for stiles and rails with and including standard locking device for shutters complete all as specified and as directed.
(a) All aluminium sections including glazing clips, snap beading, joining cleats, rubber packing, screws etc., as required are deemed to be included in the rate quoted.
(b) Particle board inserts as required shall be measured and paid separately.
Fixing only anodised aluminium sliding shutters as in cupboards consisting of 02 Nos shutters with two track section for frame and shutters with particle board inserts complete all as specified and as directed.
(a) All aluminium sections including snap beading, joining cleats, glazing cilps etc. shall be measured under aluminium shutters separately as supply only.
(b) Supply only particle board inserts as required shall be measured and paid separately.
(c) The fixtures given are for shutter of approximate size not exceeding 1.50 sqm each.
Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples fixed to wooden / steel frames complete all as specified and as directed.
Sheet glass, 4mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Supply only prelaminated particle board minimum 9mm thick, interior grade, one side prelaminated with decorative choice lamination and other side balancing white as inserts in aluminium framework complete all as specified and as directed.
Cupboard knobs 40mm dia, fixed with nut, screw and washer of brass, polished complete all as specified and directed.
Rendering 10mm thick in CM(1:6) on fair faces of brickwork finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 5mm thick in CM(1:3) on concrete surfaces complete all as specified and as directed.
Rendering 5mm thick in CM(1:3) on concrete surfaces as in ceilings finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 10mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces with floating 5mm thick in CM 1:4 mixed with WPC complete all as specified and as directed.
Liquid water proofing compound shall be measured and paid separately as supply only.
Rendering 10mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces finished fair and even complete all as specified and as directed.
Plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate, 100mm thick as in sub-base complete all as specified and as directed.
Plain cement concrete 100mm thick, 1:2:4, type B1, using 20mm graded stone aggregate finished fair and evencomplete all as specified and as directed.
Forming dummy joints 75mm deep x 10mm wide filled with sealing compound, Grade ‘A’ duly primed complete all as specified and as directed.
Concrete flooring for 100mm thick with RMC M-25 grade (Design Mix), using vaccum dewatering method, laid in alternate bays including steel form work of MS channel sections of depth equal to thickness of concrete floor and trowelled with power trowel float finish to obtain level and joints filled with sealing compound complete all as specified and as directed.
Joint filling with sealing compound shall be measured and paid separately.
Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ for thickness of concrete slab 100mm complete all as specified and as directed.
Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B1 quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed.
Plain cement concrete 75mm thick, 1:3:6, type C1, using 20mm graded stone aggregate as in plinth protection surface finished fair and even complete all as specified and as directed.
Joints in plinth protection 6mm wide and 75mm deep filled with mastic filling comprising 1 Part of heated bitumen 85/25 grade and 3 parts of sand (all by weight) complete all as specified and as directed.
Preparing newly plastered surfaces of wall and applying three coats of white wash on plastered wall surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed.
Preparing newly plastered surfaces of ceiling and applying three coats of white wash on plastered ceiling surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed.
Preparing newly plastered surfaces of wall, applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed
Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in small articles such as stop, covers, gully gratings, hold fasts etc., , area not exceeding 0.10 sqm each and treated with tar or coal tar black paint and sanding with clean sharp sand complete all as specified and as directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in ends of posts, backs of chowkats etc., area exceeding 0.10 sqm but not exceeding 0.50 sqm each and treated with tar or coal tar black paint and sanding with clean sharp sand complete all as specified and as directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described and treated with tar or coal tar black paint and sanding with clean sharp sand complete all as specified and as directed.
Rendering in CM 1:4, 10mm thick on concrete surfaces as on top of chajjas mixed with WPC complete all as specified and as directed.
Coving on junction of chajja to wall 75mm wide complete all as specified and as directed.
Rendering 10mm thick in CM(1:3) over roof slab when the concrete is green, mixed with liquid water proofing compound and finished even and smooth without using extra cement complete all as specified and as directed.
Supply only liquid Water proofing compound shall be measured and paid separately.
Preparing the rendered surface thoroughly to remove all loose particles, dirt / dust particles and applying a uniform coat of blown grade bitumen VG-10 @ 1.20 kg/sqm conforming to IS 702 over a coat of bitumen primer @ 0.40 Litres / Sqm followed by APP membrane reinforced with polyster non woven fabric 3mm thick weighing not less than 3.6 kg / sqm laid on primed surface by forced application followed by a finishing coat of solar reflective aluminium paint @ 0.10 litres / Sqm complete all as specified and as directed.
For detailed specifications please refer particular specifications and list of manufacturers given here-in-after and the rate rate quoted shall include for the same.
SCH "A" PART-II (INTERNAL ELECTRIFICATION)
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for one light point controlled by one switch.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ Sl Item No.71 here-in-before but for one ceiling fan point controlled by one switch and regulator
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ Sl Item No.76 here-in-before but for One switch socket outlet point 3 pin 5 Amps on independent board.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ Sl Item No.76 here-in-before but for One switch socket outlet point 3 pin 5 Amps on same board with other switches.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ Sl Item No.76 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
Switch piano, flush type single pole, one way, 5 Amps complete all as specified and as directed.
Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps universal type complete all as specified and as directed.
Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal type complete all as specified and as directed.
Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed.
Stepped type electronic fan regulator, 300 W, flush type, including fixing on existing laminated sheet complete as specified and as directed.
Surface and wall mounted LED tube light fitting, 20 W, batten type, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all accessories, suitable for operation on AC, single phase 220 / 230 Volts, 50 Hz supply, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed.
(a) Make shall be C & S Cat No.NAKSHATRA / 20W or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
LED building security light fitting 20W made up of pressure die cast aluminium housing with high power LED as lighting source and lens with IP66 protection and impact resistance of IK07., complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 40mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.
(a) Make shall be C & S Cat No.INDUS / 20W / LS or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Ceiling fan 1200mm sweep, without regulator, double ball bearing type, opal white colour, with suitable down rod, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan complete all as specified and as directed.
Make shall be of Usha Cat No.ENERGIA ISI or equivalent of makes as listed here-in-after.
MCB DB SPN 4 way, single door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and DP / SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
(a) Make shall be as under or equivalent of makes as listed here-in-after.
(i) Legrand Cat No. 5076 10
(ii) Havells Cat No. DHDNSHODAW04
(iii) C & S Cat No. CSDBSPNDD04
(b) MCBs as required shall be measured and paid separately.
MCB 6-40 Amps, SP, 240 Volts, 50 Hz, AC supply, "C" curve, with breaking capacity of 10 kA complete all as specified and as directed.
MCB 40 Amps, SPN, 240 Volts, 50 Hz, AC supply, "C" curve with breaking capacity of 10 kA complete all as specified and as directed.
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
SCH "A" PART-II (EXTERNAL ELECTRIFICATION)
Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
Punned thickness only shall be measured.
Burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
Plain cement concrete, type C1, 1:3:6, using 20mm graded granite stone aggregate as in coping of poles, platform above ground level including weathering, slightly rounded or chamfered angles, including necessary formwork complete all as specified and as directed.
Plain cement concrete 1:4:8, type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of the following sizes complete all as specified and as directed.
Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(a) 2 core, cross sectional area 10 sqmm.
(b) 3.5 core, cross sectional area 35 sqmm.
(c) 3.5 core, cross sectional area 50 sqmm.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under roads / crossings etc., of the following bores for cable protection complete all as specified and as directed.
Earthwork, cutting across roads etc., as required shall be measured and paid separately.
(a) 40mm bore of pipe..
(b) 50mm bore of pipe.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and fixed on poles of the following bores for cable protection complete all as specified and as directed.
(a) 40mm bore of pipe..
(b) 50mm bore of pipe.
Horizontal directional drilling (HDD) using trenchless technology using ultra sound technique and necessary machines, including pilot drilling, pre-reaming, reaming suitable for 150mm / 160mm dia HDPE pipe, with and including HDPE pipe of pressure not less than 4 kg / sqcm, grade PN-6 PE-80 conforming to IS-4984 with fittings complete drilling carried out under road, pavement, hardstanding at a level upto 2.0m below existing level work carried out in any type of soil strata complete all as specified and as directed.
Photographic record of HDD work carried out shall be maintained and the same shall be forwarded to Accepting Officer in digital form.
Cutting existing bituminous road surfaces to a depth not more than 150mm, and making good the surface with PCC 1:3:6, type C1, using 20mm graded stone aggregate to match to the adjacent surface after laying pipes / cable including removal of debris to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
The plan area of the road surface cut for laying pipes shall be measured for purpose of payment.
Design, fabrication, supply, installation, testing and commissioning of LT control panel, intdoor type, made up of CRCA sheet 3mm thick to accommodate the accessories as detailed below with hinged doors, with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and in accordance with IS-13947 (Part-I) 1993 & IS-8623 and all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with rating 300 Amps for 3 phase and neutral with heat shrinkable PVC coloured sleeves and aluminium earth bus of suitable size mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB 200 Amps, 4 pole, 415 Volts, 50 Hz, 25 kA with fixed thermal and fixed magnetic setting - 01 No.(incoming)
(e) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.(incoming)
(f) MCCB 100 Amps,3 pole, 415 Volts, 50 Hz, 25 kA with fixed thermal and fixed magnetic setting - 01 No.(outcoming)
(g) MCCB 63 Amps,3 pole, 415 Volts, 50 Hz, 25 kA with fixed thermal and fixed magnetic setting - 01 No.(outcoming)
(h) MCB 40 Amps, TP, 415 Volts, 50 Hz, AC supply, "C" curve with breaking capacity of 10 kA complete all as specified and as directed.
(k) The LT panel board shall be kept on platform 450mm above ground level, mounted on base framework and legs 900mm long of angle iron 60mm x 60mm x 6mm planted into platform of PCC 1:2:4, type B1, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 25mm x 4mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 32mm x 6mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
SCH "A" PART-III (AIR COMPRESSOR AND ALLIED PLUMBING)
Supply, installation, testing and commissioning of tank mounted air compressor with air dryer of capacity 30 HP / 24 kW, 380 V / 415V tank mounted, air cooled, belt drive, fixed speed air compressor with tank mounted air dryer and set of coalesce type particulate pre filter and after filter engine for high performance efficiency and including PCC platform and control panel with suitable size and capacity of starter with standard fittings, accessories complete all as specified and as directed with the following technical specifications / parameters and components:-
(a) Absolute inlet pressure - bar/psi - 1/14.5
(b) Relative humidity - 70%
(c) Air inlet temperature - 20 deg Celsius / 68 deg Fahrenheit
(d) Maximum / minimum effective working pressure bar 4-7
(e) Maximum / minimum ambient temperature 40 deg / 0 deg Celsius
(f) Installed power 30 HP / 24 kW, 380 V / 415V, 3 phase, 50 Hz
(g) Sound pressue level - dB(A) 68
(h) Oil capacity 4.4 lits
(j) Dust and coalescence filter (0.1 micron / 0.1 mg/mc) filters with the ability to intercept solid / liquid particles. Suitable as a pre-filter to avoid premature clogging of the oil separator filter.
(k) Fine coalescence filter (0.01 micron/0.01 mg/mc) suitable for use in installations where purity of air is a must.
(l) Activated carbon filter (0.005 ppm / 0.005 mg / mc) to remove oil (odours and vapours) for applications where low oil content is required.
(m) Receiver:- Storage and handling of high air consumption, for pressure stabilisation and condensate separation.
(n) Refrigeration:- Eliminates water down to a pressure dew point of 37.4 deg Fahrenheit (at reference conditions) with a water of 6 gr/cum.
(o) Oil Water Separator:-Separating both substances (water and oil) resulting in rinsed water which can be discharged easily.
(p) Control Panel:- Suitable inbuilt control panel with starter as per compressor capacity with all connected accessories complete.
The final mechanical run test and performance test in the factory premises shall be carried out in the presence of an officer nominated by the Accepting Officer the cost of which is deemed to be included in the iten rate quoted.
Supply, installation, testing and commissioning of tank mounted air compressor with air dryer of capacity 20 HP / 15 kW, 380 V / 415V tank mounted, air cooled, belt drive, fixed speed air compressor with tank mounted air dryer and set of coalesce type particulate pre filter and after filter engine for high performance efficiency and including PCC platform and control panel with suitable size and capacity of starter with standard fittings, accessories complete all as specified and as directed with the following technical specifications / parameters and components:-
(a) Absolute inlet pressure - bar/psi - 1/14.5
(b) Relative humidity - 70%
(c) Air inlet temperature - 20 deg Celsius / 68 deg Fahrenheit
(d) Maximum / minimum effective working pressure bar 4-7
(e) Maximum / minimum ambient temperature 40 deg / 0 deg Celsius
(f) Installed power 20 HP / 15 kW, 380 V / 415V, 3 phase, 50 Hz
(g) Sound pressue level - dB(A) 68
(h) Oil capacity 4.4 lits
(j) Dust and coalescence filter (0.1 micron / 0.1 mg/mc) filters with the ability to intercept solid / liquid particles. Suitable as a pre-filter to avoid premature clogging of the oil separator filter.
(k) Fine coalescence filter (0.01 micron/0.01 mg/mc) suitable for use in installations where purity of air is a must.
(l) Activated carbon filter (0.005 ppm / 0.005 mg / mc) to remove oil (odours and vapours) for applications where low oil content is required.
(m) Receiver:- Storage and handling of high air consumption, for pressure stabilisation and condensate separation.
(n) Refrigeration:- Eliminates water down to a pressure dew point of 37.4 deg Fahrenheit (at reference conditions) with a water of 6 gr/cum.
(o) Oil Water Separator:-Separating both substances (water and oil) resulting in rinsed water which can be discharged easily.
(p) Control Panel:- Suitable inbuilt control panel with starter as per compressor capacity with all connected accessories complete.
The final mechanical run test and performance test in the factory premises shall be carried out in the presence of an officer nominated by the Accepting Officer the cost of which is deemed to be included in the iten rate quoted.
Water tubing 3-layer PP-R (Polypropylene random) copolymer surface run pipes SDR 7.4 (PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot and cold water supply including fixing PP-R plain and brass threaded fittings fixed to walls, ceilings or in floors etc., of outer dia of pipe 40mm complete all as specified and as shown on drawing.
PP-R specials and other fittings fixed in the pipeline shall be measured and paid separately as supply only.
Water tubing 3-layer PP-R (Polypropylene random) copolymer surface run pipes SDR 7.4 (PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot and cold water supply including fixing PP-R plain and brass threaded fittings fixed to walls, ceilings or in floors etc., of outer dia of pipe 25mm complete all as specified and as shown on drawing.
PP-R specials and other fittings fixed in the pipeline shall be measured and paid separately as supply only.
Supply only the following PP-R specials and other fittings to be incorporated in PP-R pipeline complete all as specified and as shown on drawing.
40mm PP-R Tee
40mm PP-R Elbow
40mm PP-R Coupler
40mm x 32mm PP-R MTA
40mm x 25mm PP-R Reducer Tee
32mm brass ball valve
40mm PP-R Clamp
25mm x 15/16mm PP-R MTA
15/16mm brass ball valve
25mm PP-R Clamp
15/16mm x 12mm PU Adapter
32mm hydraulic hose R1, 1.5 meter
32mm hydraulic Eix Nipple
15/16mm Auto drain valve
CP FRL 15/16mm with inlet PU hose
HARI ENTERPRISES
pmv.enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .