Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
17 Apr 2021, 4:00 pmClosed
Executive Engineer
Executive Engineer, Doctors colony, Mahanadi Division, CWC, Burla pin-768017
SECURITY SHED AT SUB-DIVISION, CWC, RAIPUR
2021_CWC_625044_1
MD/HQ/NIT/2020-21/492-99
Open Tender
Civil Works
90 days
MAHANADI DIVISION, CENTRAL WATER COMMISSION, BURLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
8 Jun 2021
31 Mar 2021
19 Apr 2021
31 Mar 2021
17 Apr 2021
31 Mar 2021
Amount
Earthwork in excavation by manual means in foundation trenches (not exceeding 1.5m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms,lift up to 1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50m.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m = 1/3
Providing and laying in position cement concrete of specific grade excluding the cost of centering and shuttering with 1:4:8 (1 cement: 4 fine sand:8 graded stone aggregate 40mm nominal size)
Brick work with F.P.S bricks of class designation 75 in foundation and plinth in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Brick work with F.P.S bricks of class designation 75 in superstructure above plinth level upto floor v level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, Shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform
Providing 20 mm cement plaster by 1:6 cement plaster (1 cement : 6 coarse sand) over brick work
Finishing walls with Acrylic Smooth exterior paint of required shade:LNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete with 40 mm thick with 20 mm nominal size stone aggregate.
Providing and Fixing cement concrete chowkhats in existing opening including embedding chowkhats in floors or walls embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using M.S. angels 40x40x6 mm for diagonal braces
Providing and Fixing of Anodised Aluminium glazed Sliding windows.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: 25 mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
RAJ KISHOR DEBTA
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid