Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.5 L+₹44,255 (8.80%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-Finance L2 |
Tender Value
₹8.8 L
EMD Value
₹17,500
Closing Date
8 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR MAINT OF COOLING APPLIANCES INCLUDING ALLIED WORKS AT AF STN DADRI
2021_MES_423166_1
GE (FBD)/AF-44/2020-2021
Open Tender
Civil Works
Item Rate
180 days
AF STATION DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹17,500
Yes
13 Mar 2021
17 Feb 2021
10 Mar 2021
17 Feb 2021
8 Mar 2021
24 Feb 2021
18 Feb 2021 - 23 Feb 2021
60 days
Amount
M&L for servicing of Indoor unit & Out door unit of Split type AC of 1.5 tone capacity by taking out the same from existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part and reinstall at the same location and clean water with water pressure gun, greasing of fan , motor , blower etc complete all as specified and directed by the Engineer-in-Charge
All as per item No. 01 but split type AC of 2.0 ton complete all as specified and directed by the Engineer-in-Charge
M&L for servicing of Window type AC of 1.5 tone capacity by taking out the same from existing location , cleaning of condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution and clean water, greasing of fan , motor , blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split AC of 1.5 /2.0 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split AC of 1.5 /2.0 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the green R-410/309 etc or equilvent as required on site and testing for satisfactiory working condition as directed by Engineer-in-Charge
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed by the Engineer-in-Charge
M&L for Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x 2.5 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by the Engineer-in-Charge
M&L in repair for taking out unserviceable sealed unit (compressor) 1.5 ton capacity , single phase, 230 volt of models as existing and replacing the same with new sealed unit (compressor) including necessary modification of the foundation as required to suit the compressor, vacumacation , pressure , testing, leaking, rectification incl gas charging R-22 and testing complete to the entire satisfaction of Engineer-in-Charge
All as per item S.No 08 above but 2 TR complete all as specified and directed by the Engineer-in-Charge
All as per item S.No 08 above but suitable for refrigerent R 410a for 1.5 TR complete all as specified and directed by the Engineer-in-Charge
All as per item S.No 08 above but suitable for refrigerent R 410a for 2 TR complete all as specified and directed by the Engineer-in-Charge
M&L for Split AC outdoor unit body only of capacity 1.5 TR complete all as specified and directed by the Engineer-in-Charge
M&L for Removing the split type AC 1.5 ton/ 2 ton capacity working on 230 V single phase /440 Volt 3 phase complete including indoor and out door unit and reinstall at any place ( with in the stn ) at height up to 5 mtr from floor level including replacement of refrigerant tubing upto 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning all as directed including making good of all disturbed surfaces complete all as specified and directed by the Engineer-in-Charge.
M&L for Split AC Indoor unit of capacity 1.5 TR complete all as specified and directed by the Engineer-in-Charge
S & F PCB card suitable of 1.5/2 ton split AC suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engr-in-Charge including replacement of defective electronic components / IC Circuits
S & F Corded remote controller suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engr-in-Charge
S & F Air filter suitable for 1.5/2 split type AC suitable of 1.5/2 ton split AC as required on site incl testing for satisfactry working condition as directed by Engr-in-Charge
S & F Thermostat suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engr-in-Charge
S & F Single pole contractor for Split type AC 50/60 Hz 240 V ( Make L & T) complete all as specified and directed by the Engineer-in-Charge
S & F Axilary contactor single phase 220 Volts 10 Amps current capacity complete all as specified and directed by the Engineer-in-Charge
S & F Start Relay suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engr-in-Charge
Supply and replace copper condenser coil assembly complete suitable for 1.5 / 2 ton window/ split type AC incl testing for satisfactry working condition as directed by Engr-in-Charge
Supply and replace evaporator coil assembly complete suitable for 1.5 / 2 ton Window / Split type AC incl testing for satisfactry working condition as directed by Engr-in-Charge
S & F Copper pipe 5 /8" complete with insulation of thickness 10 mm incl testing for satisfactry working condition as directed by Engr-in-Charge
S & F Copper pipe 3 /8" complete with insulation of thickness 10 mm incl testing for satisfactry working condition as directed by Engr-in-Charge
S & F Copper pipe 1 /4" complete with insulation of thickness 10 mm incl testing for satisfactry working condition as directed by Engr-in-Charge
S&F condensing fan motor of capacity suitable for Split AC 1.5/2 Ton testing on load for the entire satisfaction of Engineer-in –Charge
S&F in repairs running capacitor of capacity ‘45+5’ MFD, 240 volts, 50 Hz complete all as specified and directed by the Engineer-in-Charge. Make Asian/EPCOS/PRIYA/ SARDA
All as per item No 28 above but capacity 36 MFD complete all as specified and directed by the Engineer-in-Charge
S&F in repairs blower fan motor of capacity 1/30 HP, 3 speed, single phase (as per sample ) complete all as specified and directed by the Engineer-in-Charge
S&F in repair condenser fan motor of capacity 1/20 HP, single phase (as per sample) complete all as specified and directed by the Engineer-in-Charge
S&F in repair starting capacitor of capacity 6 MFD, 40 volt, 50 Hz complete all as specified and directed by the Engineer-in-Charge Make: Asian/EPCOS/Priya/Sarda
S&F in repairs starting capacitor of capacity 100-120 MFD , 440 volts, 50 Hz complete all as specified and directed by the Engineer-in-Charge Make : Tesla/ Asian/ Sarda
S&F in repairs wiring kit for capacity 1.5 ton AC Make: Tecumesh / Sri Ram/ Hitechi/Aanutrol complete all as specified and directed by the Engineer-in-Charge
Taking down rewinding of 1/30 HP fan blower motor of cooling unit of split AC unit with supper enameled copper wire of suitable gauge wire Make: Chetak/ Devi Dayal/ Usha including replacement of the shaft and bushes and testing on load for the enter satisfaction of Engineer-in-Charge
All as per item No 35 above but 1/20 HP condensing fan motor complete all as specified and directed by the Engineer-in-Charge
S&F in repair MCB 25A, ‘C’ curve type complete all as specified and directed by the Engineer-in-Charge
S&F in repairs of cable 3 core 4 sqmm FRLS PVC copper conductor. Make - Finolex/Havells/polycab
M&L for servicing of Refrigerator any size at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location all as directed by the Engineer-in-Charge
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 253 Ltr as existing make including charging of refrigerant gas F-134 and testing on full load all as specified and directed by the Engr – in – Charge.
All as per item No 40 above but capacity of refrigerator 310 Ltr complete all as specified and directed by the Engineer-in-Charge
M&L for servicing of Deep freezer of size 320 Ltr at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location all as directed by the Engineer-in-Charge
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 320 Ltr as existing make including charging of refrigerant gas F-134 and testing on full load all as specified and directed by the Engr – in – Charge.
M & L for servicing of Water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil Rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of all as directed by the Engineer –in –charge.
M & L for taking out unserviceable sealed unit (compressor) of water cooler 150/150 Ltrs capacity single phase 230 volt of as existing model and replacing the same with new sealed unit (Compressor ) including necessary modification of the foundation as required to suit the compressor, vacumisation presser testing, leakage rectification, charging of gas R-134 and testing complete to the entire satisfaction of the Engr –in – Charge.
All as per item No 45 above but compressor as existing model and replacing the same with new sealed unit (Compressor) for water cooler 80/40 Ltr capacity complete all as specified and directed by the Engineer-in-Charge
Replacement of wiring kit for water cooler of any make and capacity complete all as specified and directed by the Engineer-in-Charge. Make Hi-Tech/Aanutrol/Tecumseh/Sriram.
M & L for replacement of condensing fan motor 1/32 HP of water cooler complete all as specified and directed by the Engineer-in-Charge
All as per item No 48 above but fan motor capacity 1/16 HP complete all as specified and directed by the Engineer-in-Charge
M&L for replacement of float valve ½ dia suitable for water coolercomplete all as specified and directed by the Engineer-in-Charge
M & L for servicing of desert cooler of any capacity at existing location by cleaning of all components components with Rinse solution & clean water, greasing of fan, motor including cleaning of water storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of small parts like PVC water distributer, flexible pipe, plugs etc as required on site all as directed by the Engineer –in –charge.
M & L for scraping and removing old paint of desert cooler body (steel surfaces) and preparation of steel surfaces including necessary denting, cutting, welding etc for spray painting with approved smoke gray synthetic enameled paint (Ist quality) over a coat of Zinc chromate primer on outer surface and inner surface i.e. Water tank and body fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of Zinc chromate primer complete for desert cooler of any size and capacity including writing MES No with white paint in size of 40 to 50 mm high letter all as specified and directed by the Engr – in – Charge.
S & F Desert cooler Pump as per existing capacity complete all as specified and directed by Engr-in-charge
M & L for replacement of cooling fan motor supporting legs and PVC fan blade of 450 mm sweep for desert cooler. Make- Khaitan/ Snow cool/Crompton/ GEC
M & L for rewinding of desert cooler motor of any make with supper enameled copper wire (Thermal class E) of appropriate size make devi dayal/Chetak/Usha including replacement of gun metal bushed and steel shaft all as specified and directed by the Engr – in – Charge.
M & L in replacement of 01 Nos front grill and 3 side loovers suitable for disert cooler duly spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer as required on site complete all as specified and directed by Engr -in-charge.
M & L for replacement of desert cooler body 660x660x900mm with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge milled steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min3 mtr in length). External surface shall be spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed by the Engr – in – Charge.
M & L for replacement of running cap 4.0 MFD 440 volt make- Jaivic/Sarda/Epcos complete all as specified and directed by the Engineer-in-Charge
M & L for replacement of wood wool pad 25mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr capacity desert coolers complete all as specified and directed by the Engineer-in-Charge
M&L for servicing, repair of Voltage stabilizer of capacity 4/ 5 KVA cleaning , dusting, brushing, checking and rectify electrical conections, and other components complete all as specified and directed by the Engineer-in-Charge
S&F in repairs time delay relay suitable for 4/5 KVA voltage stabilizer complete all as specified and directed by the Engineer-in-Charge
S&F in repirs diode suitable for voltage stabilizer of capacity 4/ 5 KVA complete all as specified and directed by the Engineer-in-Charge
S&F in repairs condenser suitable for voltage stabilizer of capacity 4/5 KVA complete all as specified and directed by the Engineer-in-Charge
S&F electronic circuit board with relay suitable for 4/5 KVA voltage stabilizer of any make and testing complete all as directed by Engineer-in-Charge
M&L in repair transformer suitable for voltage stablizer 4/5 KVA as required on site complete all as directed by Engr in Charge
M&L for servicing,Taking down ceiling fan 56"/48" sweep removing cleaning of dust, properly cleaning greasing of bearing including replacing and painting connecting up complete all as sepecified and directed by Engr -in-Charge.
Supply and fixing capacitor, capacity 2.5 mfd in replacement complete all as specified and directed by the Engineer-in-Charge
Supply and fixing capacitor, capacity 3.15 mfd in replacement complete all as specified and directed by the Engineer-in-Charge
M&L for rewinding of burnt ceiling fan motor 1200/1400 mm sweep with super enamelled copper winding wire of suitable guage as per details of any make /model complete all as sepecified and directed by Engr -in-Charge.
Supply and replacement of ball bearing of ceiling fan of any size complete all as sepecified and directed by Engr -in-Charge.
Supply and fixing and connecting flexible copper twisted twin core of size 23/00076. complete all as sepecified and directed by Engr -in-Charge. Make Plaza/Kalinga
M & L Painting of Ceiling fan 48" size complete in size with super enameled synthetic paint by spraying including filling cavities and complete removing of old paint etc complete all as sepecified and directed by Engr -in-Charge.
Supply and replacement of gun metal bush of any type/make/size complete all as sepecified and directed by Engr -in-Charge.
supply and replacement of rubber real complete all as sepecified and directed by Engr -in-Charge.
Supply and replacement of U Clamp complete with nuts, bolts, pins. Heavy duty complete all as sepecified and directed by Engr -in-Charge
Supply and fixing nuts,bolts, washers and spilt pins for ceiling fan complete all as sepecified and directed by Engr -in-Charge
Supply and replace spring washers for fan blades complete all as specified and directed by the Engineer-in-Charge
M&L for servicing of wall mounting fan motor 400 mm sweep with super enamelled copper winding wire of suitable guage as per details details of any make /model complete all as sepecified and directed by Engr -in-Charge.
S&F wall mounting fan motor for 400 mm sweep complete all as sepecified and directed by Engr -in-Charge.
M&L for servicing of Exhaust fan of any size complete all as specified and directed by Engr-in-Charge.
S&F Exhaust fan 10"/12" sweep complete all as specified and directed by Engr - in- charge.
S&F PVC Exhaust fan 300MM sweep complete all as specified and directed by Engr - in- charge.
M&L for Exhaust fan motor for 300 mm sweep complete all as specified and directed by Engr-in-Charge.
Taking down carefully old electrical point wiring/sub main wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with MS conduit and T/W batten all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with Modular /single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit / cassing capping / concelled as per ground requirement medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed by the Engineer-in-Charge for following :- One light/fan point controlled by one switch.
All same as per item No 85 above but One socket point on same board with other switches complete all as specified and directed by the Engineer-in-Charge
All same as per item No 85 above but One 3 pin 5 Amps socket outlet independent with cables 1.5 sqmm size complete all as specified and directed by the Engineer-in-Charge
All same as per item No 85 above but with conductor of size 2.5 Sq mm (nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 1.5 Sq mm PVC insulated stranded copper conductor cable complete all as specified and directed by the Engineer-in-Charge.
M&L for Re wring with Modular /single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit / cassing capping / concelled as per ground requirement medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed by Engr -in- Charge.
S&F Modular switch 1 way 6A, 1 module complete all as specified and as directed by Engr-in-Charge.
S&F Modular switch 1 way 16A, 1 module complete all as specified and as directed by Engr-in-Charge.
S&F Modular Bell push 6A 1 module complete all as specified and as directed by Engr-in-Charge.
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-Charge.
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-Charge.
S&F White cover plate with frame,1 module complete all as specified and as directed by Engr-in-Charge.
All same as per item No 95 above but but 3 module complete all as specified and directed by the Engineer-in-Charge
All same as per item No 95 above but but 6 module complete all as specified and directed by the Engineer-in-Charge
All same as per item No 95 above but but 8 module complete all as specified and directed by the Engineer-in-Charge
S&F Metal flush box/ PVC box 1/2 module complete all as specified and as directed by Engr-in-Charge.
All same as per item No 99 above but but 3 module complete all as specified and directed by the Engineer-in-Charge
All same as per item No 99 above but but 6/8 module complete all as specified and directed by the Engineer-in-Charge
M/S Anand Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .