Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.9 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹2.0 L+₹7,676.54 (3.96%)Admitted-Finance 5 HARI MOHAN ROY LANE KOLKATA 700 015 KOLKATA WB 700015 | KOLKATA | WEST BENGAL | 700015 | L2 | Admitted-Finance | ||
| 3 | L3₹2.0 L+₹9,101.05 (4.70%)Admitted-Finance | L3 | Admitted-Finance |
Tender Value
₹2.0 L
EMD Value
₹4,000
Closing Date
17 Nov 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
E.E.(E)/Z-V/GRU
LIGHTING DEPARTMENT The Kolkata Municipal Corporation E/3, Circular Garden Reach Road, Kolkata-700 024 West Bengal
REPAIRING OF STREET LIGHTING SYSTEM AT UTTARAN AREAS OF KASAI PARA,KHANSAMA PARA AND OTHERS IN WARD NO. 135,BR.-XV.
2026_KMC_1048182_1
KMC/LTG/CM/20/26-27/84
Open Tender
Electrical Work/ Equipment
Percentage
30 days
WARD NO 135
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹4,000
19 Nov 2026
4 Nov 2026
18 Nov 2026
4 Nov 2026
17 Nov 2026
4 Nov 2026
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 14. Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface,loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km | 2 | PERPOLE | 649 | ₹1,298 |
| 2 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1) b) 4 SWG ;5.0 mtrs; 45 Kg | 2 | EACH | 4,216 | ₹8,432 |
| 3 | SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).Erection of Poles.Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work(site including filling up the excavated earth pit with shifted soil and ramming properlyUpto 9.0 mtr. Size 0.6x0.6x1.70 mts | 2 | SET | 2,835 | ₹5,670 |
| 4 | Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole CAP etc. Supplying & Fixing of m.s. Sole plate (450x450x6m) at the bottom of pole. | 2 | EACH | 887 | ₹1,774 |
| 5 | Painting steel tubular pole including projected arm bracket with one coat of red oxide primer and two coats with si lverlac AI. paint ete. (Scraping where necessary).Painting upto7 mtr Pole | 26 | EACH | 256 | ₹6,656 |
| 6 | Construction of foundation of existing pole below G.L. having of dimension of 0.6 x 0.6 x 0.6 mtr (2'x 2'x2') with graded stone chips (19mm down) in cement concrete proportion of 6:3:1 after necessary excavation including scraping. | 9 | EACH | 1,171 | ₹10,539 |
| 7 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 11. Providing CC (6:3:1) muffing 0.3 mtr dia upto the height of 0.3 mtr. above the ground level around the pole base complete with 3 mm thick neatly finished cement plaster all-round after dismantling the unserviceable muffing if necessary | 13 | EACH | 250 | ₹3,250 |
| 8 | Hoisting fixing and commissioning of luminaries including making necessary connection and earthing attachment: HPMV/HPSV luminaries/LED fittings of any wattage | 8 | EACH | 96 | ₹768 |
| 9 | Replacement of following item after listing including removing & Re-fixing of luninaries as required (Materials will be supplied departmentally) Sodium/Metal/MV/70 watt/150 watt/M.L./250watt/ 400watt/M.L.Lamp/Street light LED fittings | 8 | EACH | 64 | ₹512 |
| 10 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe. | 8 | SET | 1,369 | ₹10,952 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.38 MB
FORM.pdf
Tender Documents • 0.82 MB
BOQ_2566758.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .