Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.9 LAccepted-AOC | ₹5.9 L | 1 | Accepted-AOC Awarded |
| 2 | 2₹5.9 LRejected-AOC | ₹5.9 L | 2 | Rejected-AOC Not Awarded |
| 3 | 3₹5.9 LRejected-AOC | ₹5.9 L | 3 | Rejected-AOC Not Awarded |
Tender Value
₹6.0 L
EMD Value
₹6,000
Closing Date
25 Nov 2019, 5:00 pmClosed
S.E., E.T.C., Bareilly
Superintending Engineer Hydel Campus, Near L.I.C. Office Rampur Garden, Bareilly
Construction of 132KV Budaun TSS Feeder Bay alongwith other associated Works at 220KV Sub Station Budaun under E.T.D., Budaun
2019_UPTCL_402453_1
E-Tender No. 57 / W / ETC(B) / 2019 - 20
Open Tender
Electrical Works
120 days
Budaun
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
A/c No 10897666087 IFSC SBIN0000615 S.B.I. Bly
₹6,000
22 Sept 2020
11 Nov 2019
26 Nov 2019
11 Nov 2019
25 Nov 2019
11 Nov 2019
11 Nov 2019 - 25 Nov 2019
Amount
Construction of 132KV Budaun TSS Feeder Bay alongwith other associated Works at 220KV Sub Station Budaun, with all Cost of Men, Materials, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer as per Site Requirement and Details below : (1) Supply of PG Clamp duly made of LM-6 Aluminium Alloy, suitable for ACSR Moose to ACSR Moose Conductor complete with 4 No. 16 × 90 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Sample.
(2) Supply of PG Clamp duly made of LM-6 Aluminium Alloy, suitable for ACSR Moose to ACSR Panther Conductor complete with 4 No. 16 × 90 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Sample.
(3) Supply of PG Clamp duly made of LM-6 Aluminium Alloy, suitable for ACSR Panther to ACSR Panther Conductor complete with 3 No. 16 × 75 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Sample.
(4) Supply of 132KV Isolator Bi-Metallic Terminal Connector duly Made of LM-6 Aluminium Alloy, suitable for 132KV Isolator & Twin ACSR Panther Conductor, Complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Sample.
(5) Supply of 132KV C.B. Terminal Connector duly Made of LM-6 Aluminium Alloy, suitable for 132KV C.B. & Twin ACSR Panther Conductor, Complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Sample.
(6) Supply of 132KV C.T. Bi-Metallic Terminal Connector duly Made of LM-6 Aluminium Alloy alongwith Bi-Metallic Sleeve / Plate, suitable for 132KV C.T. & Twin ACSR Panther Conductor, Complete with 4 No. 12 mm size G.I. Bolts, Nuts & Spring / Plain Washers, as per Sample.
(7) Supply of 132KV Post Insulator Clamp duly Made of LM-6 Aluminium Alloy, suitable for 132KV Post Insulator & Twin ACSR Panther Conductor, complete with G.I. Bolts, Nuts, Spring & Plain Washers, as per Sample.
(8) Transportation of Galvanized Sub Station Structures from EFU Naini, Prayagraj to 220KV Sub Station Budaun (Approx. Distance 500 Km) : (a) Sorting, Weighing & Loading of Galvanized Sub Station Structures on Private Trucks to be Arranged by the Contractor at EFU Naini, Prayagraj
(b) Safe Transportation of Galvanized Sub Station Structures by Private Trucks duly Arranged by the Contractor from EFU Naini, Prayagraj to 220KV Sub Station Budaun including Toll Charges. (1 Job per Truck)
(c) Unloading of Galvanized Sub Station Structures from the Trucks, then Sorting & Proper Stacking of same at Safe Storage Place at the Sub Station.
(9) Erection of Following Structures & Equipments including their Shifting from Storage Place at the Sub Station to Erection Site : (a) Lattice type Main Structures
(b) 132KV SF6 C.B.
(c) 132KV C.T.
(d) 132KV P.T.
(e) 132KV L.A.
(f) 132KV Bus Isolator with associated PIs
(g) 132KV Line Isolator with associated Earth Blades & PIs
(h) 132KV Tandem Isolator with associated PIs
(i) 132KV Post Insulators
(j) 132KV C.T. Junction Box
(k) 132KV P.T. Junction Box
(l) 132KV Feeder Control & Relay Panel
(m) 132KV Distance Protection Panel
(n) ABT Energy Meter Cubical
(10) Jumpering of Equipments of 132KV Feeder Bay with the help of ACSR Panther Conductor to Connect the Bus Bar Conductor of Main Bus & Transfer Bus with Equipments and Equipments to Equipments with the help of suitable Clamps / Connectors including, Cutting, Bending, Shaping etc. of the Conductor as per Site Requirement.
(11) Laying of Following sizes Control Cables in Cable Trenches from Control & Relay Panels in Control Room to various Equipments, Junctions Boxes etc. in Switchyard as per Cable Schedule including Shifting of Cables in Drums from Storage Place at the Sub Station to Erection Site and Shifting Back the Balance Cables to Stores at the Sub Station : (a) 2C x 2.5 mm2
(b) 4C x 2.5 mm2
(c) 6C x 2.5 mm2
(12) Termination of various sizes above Laid Control Cables Extending D.C. Supply from DCDB and A.C. Supply from ACDB to Control Panels & Equipments including Drilling of Holes, Providing & Fixing of Cable Glands, Ferrules & Crimping type Lugs.
(13) Making of Shielding Mesh for 132KV LAs by Fabrication of 3 Meter Long Electrodes with 36 mm dia. M.S. Rod Bar having 150 mm long Conical Shape and then its Piercing Vertically in the Ground with Top 500 mm below Ground Level, Jointing the Electrodes with 75 × 10 mm size M.S. Flat by Welding for making of Mesh, Connecting the Shielding Mesh with Main Earth Mat at 2 Places and finally, Painting of the Shielding Mesh / Earthing Strips with Anti-Corrosive Paint, with due Digging of Earth / Trench & its Back Filling.
(14) Earthing by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of following sizes M.S. Flats for Diagonal / Double Earthing of the Main & Aux. Structures, Equipments and Cable Trenches including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below : (a) Earthing of LAs with 75 × 10 mm size M.S. Flat.
(b) Earthing of Main & Aux. Structures and Equipments (CB, Isolators, CTs, PTs, C&R Panel, DPP, Junction Boxes etc. with 50 × 6 mm size M.S. Flat.
(c) Earthing of Cable Trench with 25 mm × 6 mm / 25 × 5 mm size M.S. Flat
(15) Painting of M.S. Earthing Strips by Rubbing with Sand Paper & Wire Brush, then Painting with 1 Coat of Red Oxide Primer & 2 Coats (The 2nd Coat of Paint shall be Applied at the Gap of 48 hrs. when 1st Coat of Paint is done & Checked by concerned S.D.O. / J.E.) of 1st Quality Synthetic Enamel Paint of Asian / Berger / Nerolac make in Bus Green / Black Colour as per Details below : (a) 75 × 10 mm size M.S. Earthing Strip in Bus Green Colour.
(b) 50 × 6 mm size M.S. Earthing Strip in Bus Green Colour.
(c) 25 × 6 mm / 25 × 5 mm size M.S. Earthing Strip in Black Colour.
(16) Providing of 3 Phase L.T. A.C. Supply Cubical of size 1200 × 600 × 500 mm with Hinged Door and Proper Locking Arrangement duly made of 16 SWG M.S. Sheet and Painted with Grey Colour Synthetic Enamel Paint. The L.T. A.C. Supply Cubical should be Fitted with 3 No. 100 Amp. Copper Neutral Link, 4 No. 100 Amp. Aluminum Bus Bar (3 Phase + Neutral), 5 No. 32 Amp. TPN MCB, 6 No. 40 Amp. DP MCB, 40 No. Link type Terminal Bock, Cable Glands etc. with Internal Wiring and then Installation on M.S. Angle Frame Structure duly Grouted in Ground by due Construction of Concrete Plinth.
(17) Earthing of L.T. A.C. Supply Cubical with Providing & Fixing of 600 × 800 × 8 mm size G.I. Plate with its Top At Least 3 Meter below the Ground Level with 20 mm dia. G.I. Pipe & Funnel for Watering, 1 No. 8 SWG G.I. Wire Earthing Lead etc. with Alternate Layer of Charcoal / Coke and Salt At Least 150 mm Thick Around it.
LASHANI ENTERPRISES
SHRI BALAJI ENGG. WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid