Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹26.8 L+₹31,775.60 (1.20%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹27.2 L+₹68,564 (2.58%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹29.1 L+₹2.6 L (9.83%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹29.2 L
EMD Value
₹58,420
Closing Date
15 Aug 2023, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin 152116
Special repair for replacement of CFL lights by LED lights and other sanctioned works at Fazilka mil stn.
2023_MES_609514_1
GE ABH-35/23-24
Open Tender
Civil Works
Item Rate
180 days
FAZILKA MIL STN
AS PER NIT
7 documents required · 7 mandatory
₹500
GE ABOHAR
₹58,420
Yes
24 Oct 2023
18 Jul 2023
17 Aug 2023
18 Jul 2023
15 Aug 2023
1 Aug 2023
Amount
supply and fixing in replacement of LED complete fitting including batten, T8 retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accesssories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engr-In-charge:- (a) Lumen system efficiency of luminaire should be minimum 100 lumen per watt )b) Input voltage range 140-270 volt (c) Temp operating range: Minum 10 degree Celcium Plus 45 (d) Power facto minimum 0.95 (e) THD Max 10% (f) IP rating : IP:20 (g) CRCA pre coated housing with two coloured plastic end cap (h) LED driver of the same make as of the luminaire (j) LED driver should be complete with all protectiions viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer (k) Surge protection minimum 2.5 KV (l) CCT:6500K (m) CRI morethan 80 (n) Rated lifetime 50000 burning hrs (average 10 to 12 hrs daily) Catpart No. DIJB12LT8-20 for T-8 batten and LGT8-20-865-2 for LED glass tube rod of crompton or equivalent of Bajaj/ Havells.
Supply and fixing in replacement of LED tube light fiting 1x5W, (appx 2 feet long) environment friendly 1including electric ocnnection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose tolight fitting, complete fitting with all accessrries and following spcifications including taking down old unserviceable light fitting any type complete all as specified and directed by Engr-In-charge (a) Lumen system efficiency of luminaire should be minimum 100 lumen per watt )b) Input voltage range 140-270 volt (c) Temp operating range: Minum 10 degree Celcium Plus 45 (d) Power factor minimum 0.95 (e) THD Max 10% (f) IP rating : IP:20 (g) CRCA pre coated housing with two coloured plastic end cap (h) LED driver of the same make as of the luminaire (j) LED driver should be complete with all protectiions viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer (k) Surge protection minimum 2.5 KV (l) CCT:6500K (m) CRI morethan 80 (n) Rated lifetime 50000 burning hrs (average 10 to 12 hrs daily).Catpart No. CCS-103-05-65-SL-DP-NWH of crompton or equivalent of Bajaj/ Havells.
M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete, Make-Anchor/SSK/CONA
Supply and fixing in replacement of LED tube light fiting 1x10W, (appx 2 feet long) environment friendly including electric ocnnection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose tolight fitting, complete fitting with all accessrries and following spcifications including taking down old unserviceable light fitting any type complete all as specified and directed by Engr-In-charge (a) Lumen system efficiency of luminaire should be minimum 100 lumen per watt )b) Input voltage range 140-270 volt (c) Temp operating range: Minum 10 degree Celcium Plus 45 (d) Power factor minimum 0.95 (e) THD Max 10% (f) IP rating : IP:20 (g) CRCA pre coated housing with two coloured plastic end cap (h) LED driver of the same make as of the luminaire (j) LED driver should be complete with all protectiions viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer (k) Surge protection minimum 2.5 KV (l) CCT:6500K (m) CRI morethan 80 (n) Rated lifetime 50000 burning hrs (average 10 to 12 hrs daily). Catpart No. CCS-103-10-65-SL-DP-NHW (TRIM LINE NEU) of crompton or equivalent of Bajaj/ Havells.
M&L for ceiling light fitting of Skylux LED efficient LED surface 2'x2' (600X600MM) luminaire & glare free soft illumination of capacity 36Watt LED white colour complete suitable for roof ceailing including connecting upto with driver 3 core flexible conductor copper of suitable size complete all as specified and directed by Engr-In-charge. Make: Crompton/Havells/Philips/Bajaj
Trial bore of 200 mm dia upto 50 meter depth below ground level in any kind of soil strata including hard stone/boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc.
All as per item no 6 but depth below 50 meter to 100 meter
All as per item no 6 but depth below 100 meter to 150 meter
Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water.
Yield test for the bore well by continuously pumping for 16 hours to determine safe pumping yield complete all as specified
Supply jointing and lowering PVC slotted 150mm dia heavy duty including providing suitable jail on the slotted pipe.
Supply jointing and lowering PVC 150mm dia heavy duty pipe including joints
Supply and fixing GI pipe galvanised " Medium class " with all fitting laid in trenches of size 50 mm dia bore.
Supply and fixing GI pipe galvanised " Medium class " with all fitting laid in trenches of size 25 mm dia bore.
S & F stop valve size 25 mm cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for unions and fixed.
S & F stop valve size 50 mm cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for unions and fixed.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for pipe line in hard/dense soil, & getting out complete all as specified and directed by Engin-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
Supply installing lowering and connecting up commissioning and Testing submersible solar pump of discharge 272 LPM at 30 Mtr head coupled with 3 phase AC motor of capacity 5 HP including 2 inch DPE delivery pipe with clamp, rope, 3 core SB wire of size 2.5 sqmm from starter to summercible pump complete with 5 KW solar panel with GI structure, solar controller, modules, lightening arrester, feeder pillar box with starter and necessary plinth of size 2 meter X 2 meter works as specified by company, complete all as specified and directed.
M&L for Earthing complete with using copper plate electrode 60×60cm ×3.15mm thick electrode , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to and 20×3mm copper strip as earthing lead thick earth means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Note:- Excavation and returning filling deemed to be included in quoted rated
HARPAL ENGINEERS AND BUILDERS
CHILLANA CONSTRUCTION COMPANY
HARSH CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .