| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAdmitted-Finance | ₹31.2 L | L1 | Admitted-Finance |
| 2 | L2₹33.0 LAdmitted-Finance 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹33.0 L | L2 | Admitted-Finance |
| 3 | L3₹33.1 LAdmitted-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹33.1 L | L3 | Admitted-Finance |
| 4 | L4₹43.5 LAdmitted-Finance | ₹43.5 L | L4 | Admitted-Finance |
| 5 | L5₹44.4 LAdmitted-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | ₹44.4 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S SHRINATH CONTRACTION L4 | Shiva Enterprises L3 | M/S SHARADA ASOCIATE L5 | 8M/S TIWARI and SONS L1 | neeraj electricals L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour only for servicing / repairing of package type central AC plant unit ( out door and Indoor unit, AHU) where required in ACs or as directed by Engr-in-Charge Or concern JE at site of COD to attend and rectfy the defects by settings of controls or by repair/ replacement work to air conditioning plant unit/ system etc as per standard engineering practice,along with all necessary tools etc and keeping proper record of maintenance record in register supplied by the contractor). Notes:-
(i) Spare parts required for repair/ rectification of defects shall be mesured and paid saperatly under respactive items here in after.
(ii) Contractor will ensure proper functioning of All AC plants at all workig days times.
(iii) Repair work of plant shall be carried out by well experienced technitions/ mechanic who has experienced/ working certificate form OEM with proper tools and safety measures.
(iv) All petty small parts required for repair i.e. nuts, bolts, washers screws, saddles, grease, oil/ lubricants etc shall be provided by the contractor without any extra cost to the government.
(vi) Location and place of complaints shall be as per requirement of maintenance work of bldg in different areas of COD and MH under GE (W) Agra as directed by Engineer in charge/ JE concerned.
(vii) Contractor shall be responsible to provide conveyence and required T&P for attend the complaints.
(viii) Contractor shall be responsible for arrenging security passes from the concern department through there guidlines/ procesure. | 60 | Each Job | 2,500 ₹1,50,000 | 2,000 ₹1,20,000 | 2,000 ₹1,20,000 | 1,500 ₹90,000 | 2,500 ₹1,50,000 |
| 2.00 | Cleaning all filters of AHUs (Indoor units) alongwith its out door unit condensing coil of COD Adm Bldg, EDW, P-3 shed, medical store and medical ward, cleaning the filters with the help of blower & water pressure pump, suitable cleaning materials and washing with clean water to remove the complete dust particles and refixing the same to its original position including checking of tightness of all the nuts & bolts of out door units and combing of bend fins of out door units complete as directed.
Note: All filters and outdoor units shall be cleaned fortnightly basis upto completion of the work. | 60 | Each Unit | 1,800 ₹1,08,000 | 800 ₹48,000 | 2,000 ₹1,20,000 | 1,500 ₹90,000 | 600 ₹36,000 |
| 3.00 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units , Model No. DPUASC 220X,having compressor's capacity 1x11.0 TR and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. | 25 | Each Job | 1,800 ₹45,000 | 2,500 ₹62,500 | 2,000 ₹50,000 | 1,500 ₹37,500 | 2,000 ₹50,000 |
| 4.00 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units, Model No. DPUASC 875, having compressor's capacity 1x8.75 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. | 5 | Each Job | 1,800 ₹9,000 | 2,000 ₹10,000 | 2,000 ₹10,000 | 1,500 ₹7,500 | 1,500 ₹7,500 |
| 5.00 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units,Model No. DPUASC 550, having compressor's capacity 1x5.50 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.
Note for item Nos. 3, 4 & 5 :- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item here-in-after. | 5 | Each Job | 1,800 ₹9,000 | 2,000 ₹10,000 | 2,000 ₹10,000 | 1,500 ₹7,500 | 1,500 ₹7,500 |
| 6.00 | supply & fix in replacement the new sealed compressor of package type ACs of capacity 11.0 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed.
Make:- Danfoss Model No. SM 147 A4NLB or equivalent model of make Emerson/ Voltas as approved by GE. | 11 | Each Job | 1,10,000 ₹12,10,000 | 70,000 ₹7,70,000 | 1,10,000 ₹12,10,000 | 40,000 ₹4,40,000 | 45,000 ₹4,95,000 |
| 7.00 | supply & fix in replacement the new sealed compressor of package type ACs of capacity 8.75 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed.
Make:- Danfoss Model No. SM 110 S4EA or equivalent model of make Emerson/ Voltas as approved by GE. | 5 | Each Job | 90,000 ₹4,50,000 | 55,000 ₹2,75,000 | 80,000 ₹4,00,000 | 36,000 ₹1,80,000 | 35,000 ₹1,75,000 |
| 8.00 | supply & fix in replacement the new sealed compressor of package type ACs of capacity 5.50 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed.
Make:- Danfoss Model No. HLM 072 T4LC6 or equivalent model of make Emerson/ Voltas as approved by GE.
Notes for item Nos. 6, 7 & 8 :- (i) Refrigerant gas (R-22) and compressor oil shall be measured and paid saperatly under respactive item after for filling/topping up only
(ii) Contractor shall submit the manufacturer test certificate of compressor alongwith purchase vouchers to Engr-in-Charge for their verification and kept on record. | 4 | Each Job | 65,000 ₹2,60,000 | 40,000 ₹1,60,000 | 70,000 ₹2,80,000 | 32,000 ₹1,28,000 | 30,000 ₹1,20,000 |
| 9.00 | supply & fix in replacement, thermostatic expansion valves suitable for 1x11 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.
Make:- Danfoss or Sporlong or Alco or Emerson as approved by GE. | 10 | Each | 1,500 ₹15,000 | 3,500 ₹35,000 | 2,500 ₹25,000 | 3,000 ₹30,000 | 3,500 ₹35,000 |
| 10.00 | supply & fix in replacement,, thermostatic expansion valves suitable for 1x8.75 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.
Make:- Danfoss or Sporlong or Alco or Emerson as approved by GE. | 8 | Each | 1,500 ₹12,000 | 3,000 ₹24,000 | 2,500 ₹20,000 | 2,500 ₹20,000 | 3,000 ₹24,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
30 May 2026, 6:00 pmClosed
Maj Dinoop Kumar
GE (WEST) AGRA
REPAIR/MAIN OF CERTAIN PACKAGE TYPE ACs ALONGWITH MISC WORKS UNDER AGE E/M (W) AGRA OF GE (W) AGRA
2026_MES_762378_1
8012/1175/E8
Open Tender
Civil Works
180 days
GE (W) Agra
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (W) Agra
₹90,000
29 Jun 2026
27 Apr 2026
6 Jun 2026
27 Apr 2026
30 May 2026
11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour only for servicing / repairing of package type central AC plant unit ( out door and Indoor unit, AHU) where required in ACs or as directed by Engr-in-Charge Or concern JE at site of COD to attend and rectfy the defects by settings of controls or by repair/ replacement work to air conditioning plant unit/ system etc as per standard engineering practice,along with all necessary tools etc and keeping proper record of maintenance record in register supplied by the contractor). Notes:-
(i) Spare parts required for repair/ rectification of defects shall be mesured and paid saperatly under respactive items here in after.
(ii) Contractor will ensure proper functioning of All AC plants at all workig days times.
(iii) Repair work of plant shall be carried out by well experienced technitions/ mechanic who has experienced/ working certificate form OEM with proper tools and safety measures.
(iv) All petty small parts required for repair i.e. nuts, bolts, washers screws, saddles, grease, oil/ lubricants etc shall be provided by the contractor without any extra cost to the government.
(vi) Location and place of complaints shall be as per requirement of maintenance work of bldg in different areas of COD and MH under GE (W) Agra as directed by Engineer in charge/ JE concerned.
(vii) Contractor shall be responsible to provide conveyence and required T&P for attend the complaints.
(viii) Contractor shall be responsible for arrenging security passes from the concern department through there guidlines/ procesure. | 60 | Each Job | - | - |
| 2 | Cleaning all filters of AHUs (Indoor units) alongwith its out door unit condensing coil of COD Adm Bldg, EDW, P-3 shed, medical store and medical ward, cleaning the filters with the help of blower & water pressure pump, suitable cleaning materials and washing with clean water to remove the complete dust particles and refixing the same to its original position including checking of tightness of all the nuts & bolts of out door units and combing of bend fins of out door units complete as directed.
Note: All filters and outdoor units shall be cleaned fortnightly basis upto completion of the work. | 60 | Each Unit | - | - |
| 3 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units , Model No. DPUASC 220X,having compressor's capacity 1x11.0 TR and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. | 25 | Each Job | - | - |
| 4 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units, Model No. DPUASC 875, having compressor's capacity 1x8.75 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. | 5 | Each Job | - | - |
| 5 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units,Model No. DPUASC 550, having compressor's capacity 1x5.50 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.
Note for item Nos. 3, 4 & 5 :- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item here-in-after. | 5 | Each Job | - | - |
| 6 | supply & fix in replacement the new sealed compressor of package type ACs of capacity 11.0 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed.
Make:- Danfoss Model No. SM 147 A4NLB or equivalent model of make Emerson/ Voltas as approved by GE. | 11 | Each Job | - | - |
| 7 | supply & fix in replacement the new sealed compressor of package type ACs of capacity 8.75 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed.
Make:- Danfoss Model No. SM 110 S4EA or equivalent model of make Emerson/ Voltas as approved by GE. | 5 | Each Job | - | - |
| 8 | supply & fix in replacement the new sealed compressor of package type ACs of capacity 5.50 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed.
Make:- Danfoss Model No. HLM 072 T4LC6 or equivalent model of make Emerson/ Voltas as approved by GE.
Notes for item Nos. 6, 7 & 8 :- (i) Refrigerant gas (R-22) and compressor oil shall be measured and paid saperatly under respactive item after for filling/topping up only
(ii) Contractor shall submit the manufacturer test certificate of compressor alongwith purchase vouchers to Engr-in-Charge for their verification and kept on record. | 4 | Each Job | - | - |
| 9 | supply & fix in replacement, thermostatic expansion valves suitable for 1x11 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.
Make:- Danfoss or Sporlong or Alco or Emerson as approved by GE. | 10 | Each | - | - |
| 10 | supply & fix in replacement,, thermostatic expansion valves suitable for 1x8.75 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.
Make:- Danfoss or Sporlong or Alco or Emerson as approved by GE. | 8 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
Tender.pdf
Tender Documents • 0.39 MB
BOQ_853965.xls
BOQ • 1.15 MB
Download all tender documents and submit your bid