Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹24.9 L+₹1.2 L (4.88%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹26.0 L+₹2.3 L (9.58%)Rejected-AOC | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹27.2 L+₹3.5 L (14.6%)Rejected-AOC | L4 | Rejected-AOC Rejected due to not being L1 | |
| 5 | L5₹30.8 L+₹7.1 L (30.1%)Rejected-AOC | L5 | Rejected-AOC Rejected due to not being L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Sept 2023, 6:00 pmClosed
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 45 2023 24 REPAIR MAINTAINANCE OVERHAULING OF CEILING FANS EXHAUST FANS GEYSERS AND CONNECTED ITEMS OF CERTAIN OTM ACCN AND MD ACCN INCLUDING REPAIR MAINTAINANCE OF INTERNAL FITTINGS FIXTURES IN EME ASC UNDER GE (N) UDHAMPUR
2023_MES_614447_2
GE/U(N)-45 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹80,000
Yes
10 Oct 2023
5 Sept 2023
25 Sept 2023
5 Sept 2023
23 Sept 2023
11 Sept 2023
Amount
M&L for taking down carefully the existing copper point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, celing rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use of for taking credit and making good to disturb surfaces of walls, floors etc complete all as specified and directed by Engr-in charge. Note : (i) Old dismanteled wiring and accessories (other than reuse) will be contractors property and credit will becharge.d against schedule of credit.
M&L for taking down carefully by unscrewing from boards/ outlet boxes fittings and fixture such as, LED bulk head fitting, LED tubelight fitting etc. For re-use at site or carrying to the store (serviceable fitting shall be use) all as specified and as directed by Engr-in charge.
M&L for taking down old serviceable/ unserviceable MCB DB any type/ size etc after disconnecting (serviceable DBs/ MCBs shall be reuse) complete all as specified and directed by Engineer-in charge.
M&L for point wiring for one light point controlled by one way switch 5Amp with 1.5sqmm single core multi stranded copper conductor FRLS insulated and unsheathered heavy duty cable in colour code including continous earth wire with cable of size 1.5sqmm copper conductor flexible FRLS insulated drawn into and includig concealed PVC rigid conduit of not less than 20mm dia and 1.5mm wall thickness ISI marked terminated into annealed steel terminal boxed including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, fan regulators etc complete all as specified and directed by Engr-in charge.
M&L for point wiring with 1.5sqmm PVC insulated unsheathered copper conductor, medium grade ISI marked drawn into and including PVC concealed conduit/ PVC casing caping/ PVC opened condute with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drawn to and including surface PVC rigid non metallic conduit for one ceiling fan point conductor wire drawn into and including surface PVC rigid non metadllic conduit for one ceiling fan point controlled by one switch with and also including 1.5sqmm continous earth wire connected to common earth dolly complete all as specified and directed by Engr-in charge.
All as per item No. 04 above but for bell/ buzzer on independent board controlled by one push button bell switch complete all as specified and directed by Engr-in charge.
All as per item Srl No. 04 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr-in charge.
All as per item No. 04/05 above but for one 5 Amps socket outlet on independent board complete all as specified and directed by Engr-in charge.
All as per item No. 04 above but wire size 2x2.5sqmm to controlled the 3 pin 5/15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade unsheathered single core stranded copper conductor cable of size 2.5sqmm complete all as specified and directed by Engr-in charge.
All as per item No. 04 above but controle by 2 Nos of two way switch complete all as specified and directed by Engr-in charge.
M&L for point wiring for one light/ ceiling fan controlled by one switch with 1.5sqmm (nominal area) PVC insulated and PVC unsheathered multi stranded copper conductor cable FRLS in and including concealed PVC conduit 20mm dia medium duly ISI marked, including suitable new steel sunken boxes, modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface for one light point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathered 1.5sqmm copper conductor cable FRLS connected to commen earth doly complete including cutting, chasing the surface and then making good the same to match the existing surface and walls complete all as specified and directed by Engr-in charge.
M&L for repair/ replace ment of modular white cover plate with frame 2 modular as per site requirement complete all as specified and directed by Engr-in charge.
M&L for repair/ replace ment of modular white cover plate with frame 4 modular as per site requirement complete all as specified and directed by Engr-in charge.
M&L for repair/ replace ment of modular white cover plate with frame 6 modular as per site requirement complete all as specified and directed by Engr-in charge.
M&L for repair/ replace ment of modular white cover plate with frame 8 modular as per site requirement complete all as specified and directed by Engr-in charge.
All as per item No. 11 above but for 3/5 pins socket outlet 16 Amps independent wih 2.5sqmm incl continous earthing with multistranded copper conductor PVC insulated unshaethered size 2.5sqmm complete all as specified and directed by Engr-in charge.
S&F in repair switch piano flush type for bell push 5amps fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair switch piano type single pole 16/20 amps one way, fixed in replacement complete all as specified and directed by Engr-in charge.
All as per item No. 11 above but for bell/ buzzer on independent board controlled by one push button bell switch complete all as specified and directed by Engr-in charge.
S&F switch piano flush type single pole 5amps one way, all as specified and directed by Engr-in charge.
S&F switch piano flush type single pole two way 16amps, all as specified and directed by Engr-in charge.
S&F socket outlet two in one, 3/5 pin piano type 6amp flush type complete all as specified and directed by Engr-in charge.
S&F switch piano type single pole 16/20 amps one way, complete all as specified and directed by Engr-in charge.
S&F socket outlet two in one, 3/5 pin piano type 10/20 amp flush type complete all as specified and directed by Engr-in charge.
S&F ceiling rose, 3 terminal, PVC/ polycarbonate, isolated body complete all as specified and directed by Engr-in charge.
S&F electric bell (ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and directed by Engr-in charge.
S&F switch piano flush type for bell push 5 amps, complete all as specified and directed by Engr-in charge.
S&F electronic type fan regulator stepped type 450W/ 240Volt flush type suitable for 1200/ 1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engr-in charge.
Taking down fan, ceiling cable end, dismantling blades and keptin safe custody for refixing on same location complete all as specified and directed by Engr-in charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling ose or connector to fan obtained from item No. 29 complete all as specified and directed by Engr-in charge.
Sub main wiring with two run single core 4sqmm FRLS copper conductor cable PVC insulated, unsheathered, 1100V grade including 25mm dia PVC concealed conduit/ PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc as required fixed on wall alongwith one run of 4 sqmm core PVC FRLS insulated unsheathered copper conductor cable as continous earth wire and connecting to existing main switch board/ distribution board complete including taking down unserviceable submain of any type/ size and testing on completion etc fixed in replacement, complete all as specified and directed by Engr-in charge. Note : two run of 4sqmm and one run 4sqmm cable and one run of PVC conduit shall be measured as one rm.
Sub main wiring with two run single core 6sqmm FRLS copper conductor cable PVC insulated, unsheathered, 1100V grade including 25mm dia PVC concealed conduit/ PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc as required fixed on wall alongwith one run of 6 sqmm core PVC FRLS insulated unsheathered copper conductor cable as continous earth wire and connecting to existing main switch board/ distribution board complete including taking down unserviceable submain of any type/ size and testing on completion etc fixed in replacement, complete all as specified and directed by Engr-in charge. Note : two run of 6sqmm and one run 6sqmm cable and one run of PVC conduit shall be measured as one rm.
Sub main wiring with two run single core 1.5sqmm FRLS copper conductor cable PVC insulated, unsheathered, 1100V grade including 25mm dia in PVC concealed conduit/ PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required foxed on wall alongwith one run of 6sqmm single core PVC FRLS insulated unsheathered copper conductor cable as continous earth wire and connecting to existing mai switch board/ distribution board complete including taking down unserviceable submain of any type/ size and testing on completion etc fixed in replaceemnt, complete all as specified and directed by Engr-in charge. Note : Two run of 1.5sqmm and run 1.5sqmm cable and one run of PVC conduit shall be measured as one rm.
Sub main wiring with two run single core 2.5sqmm FRLS copper conductor cable PVC insulated, 1100V grade including 25mm dia in PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc as required fixed on wall alongwith one run of 2.5sqm single core PVC FRLS insulated unsheathered copper conductor cable as coninous earth wire and connecting to existing main switch board/ distribution board complete including taking down unserviceable submain of any type/ size and testing on completion etc fixed in replacement, complete all as specified and directed by Engr-in charge. Note : two run of 2.5sqmm and one run 2.5sqmm cable and one run of PVC casing and caping shall be measured as rm.
Fixing only serviceable MCB DB of any type and caapcity obtained from item No. 03 complete all as specified and directed by Engr-in charge.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 4way complete all as specified and directed by Engr-in charge.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8way complete all as specified and directed by Engr-in charge.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 12 ways complete all as specified and directed by Engr-in charge.
Supply and fix VTPN MCCB Double door distribution board 04ways 415volts grade IP 43 Protection grade with provision for (MCCB) as incoming and three/ single phase (TP/SP) outgoings, complete with insulated bus bar arrangement fixed flush to wall complete flushing including connections should be provide with necesary reducer lugs complete all as specified and directed by Engr-in charge.
S&F in repair thermal magnetic MCCB 4pole 63 amps 415 volts 16 Ka including making necessary arrangement complete all as specified and directed by Engr-in charge. for MCCB DB.
S&F in repair thermal magnetic MCCB 4pole 100 amps 415 volts 16 Ka including making necessary arrangement complete all as specified and directed by Engr-in charge. for MCCB DB. Make : C&S Cat No. CSC2N4/ Indoasian Cat No. 830022/ or equivalent makes to standard.
S&F in repair thermal magnetic MCCB 4pole 125/160 amps 415 volts 16 Ka including making necessary arrangement complete all as specified and directed by Engr-in charge. for MCCB DB.
S&F in repair connection and testing 'C' series SPN MCB 40 to 63 amp 240V, 50Hz, 10Ka for lighting and other domestic loads incl necessary copper lugs etc complete all as specified and directed by Engr-in charge.
S&F in repair 'C' series MCB SP 6-32 amps complete all as specified and directed by Engr-in charge.
S&F in repair 'C' series MCB SP 40 amps complete all as specified and directed by Engr-in charge.
Fixing only serviceable MCB SPN/ SP any capacity obtained from item No. 03 as above complete all as specified and directed by Engr-in charge.
Fixing only LED tubelight of 5w/12W/20W/2'x2' panel light and LED bulk head fitting 9W as obtained from srl item o. 02 above complete with all fixing accessories complete all as specified and directed by Engr-in charge.
S&F in repair LED light fitting with high out put diffuser 1feet, 5watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in charge.
S&F in repair LED light fitting mirror type with high out diffuser 2 feet, 10/12 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in charge.
S&F in repair LED lights fitting 1x20W, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexbile coper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in charge.
S&F in repair LED Bulk head (6500K) fitting of 09/10 watt surface mounting type extruded aluminium body with diffuser complete with testing complete all as specified and directed by Engr-in charge.
S&F in repair surface/ recessed mounting LED luminaire 600mm x 600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor, cases of suitable size complete all as specified and directed by Engr-in charge. Make : Crompton & Greaves, Model - Vector-VIR, Cat Pt No. LCTLRF7-36-CDL, Havell & WIPRO
S&F in repair surface/ recessed mounting LED warm light fitting polaris pan nio-III, Panel 2'x2' PLR 36 FO-ww. 35/36 watt LED environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LED as light source suitable for armstrong/ grid/ ceiling complete all as specified and directed by Engr-in charge.
S&F in repair surface/ recessed mountin LED down lighter round/ square shape 12 watt 220volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in charge.
S&F round/ square shape 15watt 220volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in charge.
S&F in repair LED Garnet 18watt PLL Lamp 4pin type, 6500 K as per sample fixed in repair complete all as specified and directed by Engr-in charge.
S&F in repair for MCCB TPN 63amp, 415volts-C curve of 10Ka complete all as specified and directed by Engr-in charge.
S&F in repair metal clad plug socket single pole enclosure with two pin earth plug and socket with one single 20amp, 240volts MCB complete all as specified and directed by Engr-in charge.
S&F in repair switch piano flush type single pole two way 5amps fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair switch piano flush type single pole 5 amps one way fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair switch piano flush type for bell push 6amps fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair socket outlet two in one, 3/5 pin piano type 5amp flush type fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair socket outlet two in one, 3/5 pin piano type 6/16amp flush type fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair switch piano type single pole 16 amps one way, fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair switch socket combination piano type 5pin 6amps flush type fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair switch socket combination piano type 6pin 16amps flush type fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair celing rose, 3 terminal, PVC/ polycarbonate, isolated body fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair electronic type fan regulator stepped type, 450W/ 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair electric bell (ding dong) AC 230/250volts grade single pole ISI marked fixed in replacement, complete all as specified and directed by Engr-in charge.
S&F in repair modular fan step regulator 120W 02 module including taking down unserviceable one complete all as specified and directed by Engr-in charge.
S&F in repair modular switch 01 way 06A, 01 module taking down unserviceable one complete all as specified and directed by Engr-in charge.
S&F in repair modular switch 01 way 16A, 01 module taking down unserviceable one complete all as specified and directed by Engr-in charge.
S&F in repair modular bell push flush type 6A, 01 module taking down unserviceable one complete all as specified and directed by Engr-in charge.
S&F in repair modular socket 6A-2/3, 02 module taking down unserviceable one complete all as specified and directed by Engr-in charge.
S&F in repair modular socket 6A/16A-2/3, 02 module taking down unserviceable one complete all as specified and directed by Engr-in charge.
S&F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc, of size 200x150x50mm deep including making necesary cutting complete all as specified and directed by Engr-in charge.
S&F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc, of size 200x150x50mm deep including making necesary cutting complete all as specified and directed by Engr-in charge.
S&F in repair 3mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for making of switches, sockets, regulators etc complete all as specified and directed by Engr-in charge.
S&F in repair 3mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for making of switches, sockets, regulators etc complete all as specified and directed by Engr-in charge.
M&L for disconnecting all electrical connection from MCB DB TPN/ Wall mounted panel box for reconnecting the sam with providing proper copper bottle lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC flexible conduit for hanging wire complete all as specified and directed by Engr-in charge. Note : replacement burnt out MCBs of any type/ size may be measured and paid seperately under relevent items.
Taking down/ removing existing damaged cable connection from MCB DB/ Wall mounted panel board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/ size from loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equality on each phase complete all as specified and directed by Engr-in charge. Note : cutting of wall/ floor shall be measured and paid seperately.
M&L for cutting of hard standing n.exc 45cm depth, and n.exc 30cm width for taking out/laying UG cable including making good distrubed suurface as per existing complete all as specified and directed by Engr-in charge.
M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below noRmal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (e) Requisite quantity of common salt and charcoal. (f) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the Engineer in charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Suplly and fix in repair energy saving LED garden light fitting,decorative,bollard type of capacity 9/11 watt with opaldiffuser &aluminium reflector complete with all accessaries and fixing arrengement on PCC block of size 45mm X 45 mm alogwith fixing nuts,bolts and PVC insulated aluminiumconductor,stranded type of size 4.0 sqmm,2 -core including taking down old/unserviceble garden light fittings any type and wattage all as directed. Make - C&S cat pt No- LTGLCW9WLED,Havells cat pt No- LHEVBDP7IN6K008,Crompton & Greaves-LPTO-40-CDL-M
S&F LED street light fitting 25/35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including theRmal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer in charge.
S&F in repair driver/ choke suitable for LED panel light fitting 2'x2' 36 watts, 240 volts AC 50 Hz electronic type complete all as specified and directed.
S&F in repair LED street/buiding ligh fitting driver/ chokesuitable for 25/35 watts, 240 volts AC 50 Hz electronic type complete all as specified and directed.
S&F in repair decorative LED gate light fitting of 30/40 watt,240 volts,diecast aluminium housing in pure polyster powder coated grey finish,top maintainable product with opening die cast cover,anti corrossive stainless steel screws & silicon gasket,HET PMMA diffuser,IP65 protection driver duly prewired up to teRminal on fiRms to IS 10322 part 5/sec, 1 :1987,suitable for pole of dia 65-75 mm in-built electronic driver complete including taking down old/unserviceble gate light fitting complete all as specified and directed .Make - Crompton & Greaves Cat part No -LPT0-40-CDL or equivalent in Bajaj/Havells/HPL/ Philips/Wipro
S&F in repair service cable un aRmoured of size 4 sqmm 2 core,1100 volts grade,heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire complete all as specified and directed.
S&F in repair service cable un aRmoured of size 6 sqmm 2 core,1100 volts grade,heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire complete all as specified and directed.
S&F in repair service cable un aRmoured of size 10 sqmm 2 core,1100 volts grade,heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire complete all as specified and directed.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC multi angular slim width it makes seamlessly blendin withthe ceiling spacewith geomsatricand aligned designes ,it can be arrenge in symmetric and abstract way to make the xceiling a pieceof art recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in charge. Make- Crompton & Greaves ,Model- Vector-I or Vector-IV Cat pt No-LCTLRF1-36-CDL/WW ,Havells or Wipro,HPL
S&F in repair compact industrial batten suitable for single TB LED tube including LED tube rod TB of capacity 20watt with in built drivered metal heat sink efficiency of v100 lumens/ W connecting up wih three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in charge. Make : C&G Cat Pt No. DIJB1'2LTB20 and LTB-20-865(2). Model ECO & Ulton, havells, Wipro, HPL
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip, or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25sqmm 4core in trenches/ floor/ pole/ GI Pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match the following complete all as specified and directed by Engineer-in charge.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip, or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16sqmm 4core in trenches/ floor/ pole/ GI Pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match the following complete all as specified and directed by Engineer-in charge.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip, or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16sqmm 2core in trenches/ floor/ pole/ GI Pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match the following complete all as specified and directed by Engineer-in charge.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip, or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10sqmm 4core in trenches/ floor/ pole/ GI Pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match the following complete all as specified and directed by Engineer-in charge.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip, or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10sqmm 2core in trenches/ floor/ pole/ GI Pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match the following complete all as specified and directed by Engineer-in charge.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip, or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6sqmm 2core in trenches/ floor/ pole/ GI Pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match the following complete all as specified and directed by Engineer-in charge.
M&L for excavation in trenches in any type of soil n.exc 1.5m deep and n.exc 1.5m wide for laying of under ground cable, electric pole and getting out complete all as specified and directed by Engineer-in charge.
M&L for returning filling including speading leveling watering and well ramming 25cm in thickness in any type of soil complete all as specified and directed by Engineer-in charge.
M&L for removing excavated materil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in charge.
M&L for dry sand cushioning to under ground cables provided with a layer of sand 8cm deep before laying the cable 15cm deoth after laying cable & stretching the cable complete all as specified and directed.
Supply and lay brick class 'B' covering as mechanical protection to cable with well burnt complete all as specified and directed by Engineer-in charge.
M&L GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia complete all as specified and directed by Engineer-in charge.
Taking down ceiling fans of any type and size after disconnecting from existing ceiling rose to connector and clamp hooks and transportation to work shop, clearing externally, dismantling and examing the rotor, startor, bearings, bushes, winding etc for serviceability and repairing/ replacing the defective parts subsequently oiling, greasing, assembling testing for proper functioing, checking for safety and proper locking, transporting back to building/ site of work shop, hanging and connecting the electrical connections, testing for noise free smooth running etc as directed by Engineer-in charge.
Taking down exhaust/wall mounted fans of any type and size after disconnecting the connections from existing ceiling rose to connector and transportation to work shop, cleaning externally, dismantling and examining the rotor, stator, bearings/bushes, winding etc for serviceability and repairing/replacing the defective parts subsequently Oiling, greasing assembling, testing for proper functioning, checking for safety security and proper locking, transporting back to building/site from work shop, hanging/fixing and connecting the electrical connections, testing for noise free smooth running etc; as directed by Engineer -in-Charge. (Note for Item No. 106 & 107 : (i) Work for repair/replacement of parts will be measured and paid separately under respective items. (ii) Minimum one technician and one helper with all type of tools and plants/Vehicle should report to E&M yard at 08.30 hrs in all working days & sundays/holidays in case of emergency for repair of any type of fan including taking down/hanging/fixing of fans. (iii) Repair work will be carried out at workshop (E&M yard complaint Cell) and repair works of fans should be completed and refixed the same with in 24 hrs after receipt of complaint. If the contactor found fail to do complaint, an amount of Rs. 50 for each complaint will be deduct from the RAR bill.
M & L for servising/oiling, greasing and overhauling of ceiling fans of any size/type at site by using appropriate grade of oil/ Grease and replacing deffective parts such as bush, bearing, split pin, rubber bush, hanging clamp, cpacitor including cleaning dust and removing old grease from fan motor bearing and applying new grease including reassembling for fixing the same complete all as specified and directed. Note: Unserviceable item shall be the property of contractor as schedule of credit
All as per item No. 108 above but for exhaust fan 150mm to 450 mm sweep any type.
Taking out defective/burnt out windings of ceiling fans of various makes from Govt Married Accn /OTM Accn of all station units under GE (North) AOR, of size 1200 mm sweep from working on 220-240 volt, 50Hz single phase AC supply and rewinding with supper enamelled new copper wire of appropriate gauge including varnishing with good quality varnish' baking up, reassembling the fan, testing including replacement of connector, flexible wire of size 23/0.0040 three core up to one metre all as directed by Engineer-in-Charge.
Taking out defective/burnt out windings of ceiling fans of various makes from Govt Married Accn /OTM Accn of all station units under GE (North) AOR, of size 1400 mm sweep from working on 220-240 volt, 50Hz single phase AC supply and rewinding with supper enamelled new copper wire of appropriate gauge including varnishing with good quality varnish' baking up, reassembling the fan, testing including replacement of connector, flexible wire of size 23/0.0040 three core up to one metre all as directed by Engineer-in-Charge.
Description all as per item No 111 here-in-before but for exhaust fans of size 150 to 300 mm sweep
Description all as per item No 111 here-in-before but for exhaust fan of size from 380 MM to 450MM sweep
Description all as per item No 111 here-in-before but for wall mounted of 400 mm sweep any type
M&L for replacement of defective ball bearing for ceiling/table/pedestal/Air-circulators fan of any size any type (Bearing make/size SKF-6201/6202/ or equivalent make of NBC) complete all as specified and directed by Engineer-in charge.
Description all as per item No 115 above but for exhaust fan any of size/make- SKF 6203/6204 or equivalent make of NBC)
M&L for replacement of defective capacitor of size 2.5 md for any type of fans suitable for 250 V including making connection complete all as specified and directed by Engineer-in charge.
Description all as per item No. 117 above but fo 0.75/1.7 mfd suitable for PVC/ steel exhaust fan complete all as specified and directed by Engr-in charge.
Description all as per item No. 117 above but for 3.15 mfd complete all as specified and directed by Engr-in charge.
Description all as per item No. 117 above but for 4.0/5.0 mfd complete all as specified and directed by Engr-in charge.
M&L for replacement of rubber real of suitable size for ceiling fan complete all as specified and directed by Engineer-in charge.
M&L for replacement of gun metal bush suitable for any type/ model/ size of fans complete all as directed by Engineer-in charge. Make : As per sample/ existing complete all as specified and directed by Engineer-in charge.
S&F in repair PVC insulated twin twisted copper conductor cable 1100V grade of size 24/.20 (0.75sqmm) complete all as specified and directed by Engineer-in charge.
S&F in replaceement steped type electronic fan regulator 60/100 watt flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed by Engineer-in charge.
S&F in repair modular electronic fan regulator, step type, 120 watt 230 volt and making all necessary connections complete all as specified and directed by Engineer-in charge.
M&L for painting of ceiling fans alongwith blades of any make/ model of size 1200 to 1400mm sweep with spray paint white in colour supper enameled paint, writing MES No. In 20mm letter size with black paint etc. complete all as specified and directed by Engineer-in charge.
Description all as per item No. 126 above but exhaust fan of any size 225mm to 380mm sweep with smoke white or grey synthetic ema,elled paint of superior quality complete all as specified and directed by Engineer-in charge.
Description all as per item No. 126 here-in-before but for exhaust fan of any size 450mm sweep complete all as specified and directed by Engineer-in charge.
M&L in replacement of MS nut & bolts anealed with two Nos of washer 8/10mm dia and 40/65mm long duly half threded and hole for split pin complete all as specified and directed .
M&L in replacement of PVC canopy suitable for 1200mm to 1400mm sweep ceiling fan complete all as specified and directed by Engineer-in charge.
M&L in replacement PVC connector 4way 6 amps with connection screws, nuts complete all as specified and directed by Engineer-in charge.
M&L in replaceemnt PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and directed by Engineer-in charge.
S&F 'S' type hook made of 12mm dia MS round bar/ MS flat strip 40x4mm of appropriate size after taking out old rusted wornout hook complete all as specified and directed by Engineer-in charge.
S&F clamp for down rod of suitable size including grounet/ reel type rubber pad with bolts, nuts and washers and split pin suitable for housing ceiling fan complete all as specified and directed by Engineer-in charge.
Taking out old, brokken and rusted louver shutter of any size exhaust fan from wall fo necessary replacement complete all as specified and directed by Engineer-in charge.
S&F of louver shutter made of GI sheet metal/ pressed steel sheet 1.2mm thick for round base and 0.8mm thick for flaps, comprising of mounting legs frames made of GI/ pressed steel flat strips of size 25mm x 3mm including heavy duty rust proof passivated bolts of size 50mm long 8mm dia to be fixed on wall faster driling, and duly painted by two coat of synthetic enamelled paint (spray painting) over a coat of primer for exhaust fan upto 300mm sweep complete all as specified and directed by Engineer-in charge.
All as per item No. 136 above but for exhaust fan 380/450 mm sweep.
S&F in replacement of ceiling fan blade set 1200mm/ 1400mm sweep for ceiling fan of any make and model aero dynamically balanced including screws for fixing with fan complete all as specified and directed.
S&F in replacement MS down rod heavy duty 15mm nominal dia 18" long duly painted in matching colour complete all as specified.
S&F in replacement MS down rod heavy duty 15mm nominal dia 24" long duly painted in matching colour complete all as specified.
S&F in replacement MS down rod heavy duty 15mm nominal dia 36" long duly painted in matching colour complete all as specified.
S&F in replacement of rigid aluminium fan blade for exhaust of caapcity 300/380/450mm including locking nut complete all as specified. As per sample/ existing complete all as specified and directed by Engineer-in charge.
Disconnection of electric and water connection and taking down carefully storage type electric water heaters (Geysers) of caapcity 25/35/50 ltrs (any Make/ Model) from its existing position and inspection of geysers for its serviceability/ unserviceability complete all as specified and directed by Engineer-in charge.
M&L for opening, dismantling, brushing and cleaning of electric water heaters ( Geysers ) of capacity 25/35/50 Ltrs, removing all the sludge , scaling and bleaching from the tank and examining of any leakage of water and tightening of nuts, bolts including reassembling and refixing its own location complete including following (a) Check and connect earth continuity to electric water heater. (b) Cheking and adjusting of pressure realease valve (c) Check and Maitenance, setting of theRmostate valve. (d) Visual examination of fusible plug. Note: (i) Spare parts/components of Geysers, shall be measured and paid separately. (ii) Transport cost for carry out Geysers from site of work to workshop & vice versa shall be deemed to be included in unit rate. (iii) Minimum two technician ( One Electrician and One Plumber) and one helper with all types of tools and plants/veh etc. should report to E&M yard at 08.30 hrs in all working days & Sundays/holidays for repair of geyser including taking down/ fixing of same. (iv) Repair works will be carried out at workshop E&M yard. (v) Repair works of geyser should completed and re-fixed the same with in 24 hrs after receipt of complaint slip. If the contactor found fail to do complaint, an amount of Rs. 100 for each complaint will be deduct from the RAR bill. (vi) Electrician with helper along with T&P and Ladder will be provided by the contractor for repairing & servicing for day to day complaints in PB Enlcve, Ashok Vihar, Old Medical Complex, CHNC and complete OTM Accn/Md Accn under this AOR.
S&F in replacement heating element of any size and any shape of capacity 1500 watt for electric water heater and make and any modal and making all electrical connection as per site requirement complete all as specified and directed by Engineer-in charge.
All as per above item SI No. 145 for electric water heater of capacity 2000 watts.
S&F in replacement the rmostat 240 volt AC temperature ajustable suitable for 25 to 50 ltr electric water heater and making electrical connection complete all as specified and directed
Supply ad fixing in replacement indicator lamp assy red and green in clour any shape and size suitable for 25 to 50 ltr electric water heater complete all as specified and directed
S&F in replacement PVC connection pipe for hot and cold connection suitable for working temp of not less than 90 degree centigrage complete with check nut and washer in both side, size 450mm long and making connection to outlet and inlet of electric water heater of 25 to 50 ltr capacity complete all as specified and directed
S&F in replacement PVC connection pipe for hot and cold connection suitable for working temp of not less than 90 degree centigrage complete with check nut and washer in both side, size 600mm long and making connection to outlet and inlet of electric water heater of 25 to 50 ltr capacity complete all as specified and directed
S&F in replacement inner shell (inner tank) made out of stainless steel sheet 20 guage suitable for 25/ 35 ltr electric water heater in existing shape and size complete all as specified and directed
All as per above item SI No. 151 do but 50 ltr electric water heater.
S&F in repalacement unsv outer body cover (existing at site any type and any make) complete with top and bottom cover, inspection plate of 25/35 ltr electric water heater duly painted with super enamelled paint two coat over a red oxide steel primer complete all as specified and directed
All as per above SI No. 153 do but 50 ltr electric water heater.
Taking down existing glass wool and supply and fix new superior quality glass wool in geysers any capacity i.e, 25/50 ltr electric water heater complete all as specified and directed
S&F in replacement inner base assy chromium brass complete any shape and size with inlet, outlet, thermostate slot, drai plug and clamp or bolts for fixing heating element as existing shape and size complete suitable for 25 ltr electric water heater complete all as specified and directed by Engr-in charge.
All as per above item SI No. 156 do but 50 ltr electric water heater.
Taking down existing unsv copper flexible cable and supply and fix new 3 core copper flexible PVC insulated multistranded cable of size 4 sqmm including making electrical connection to electric water heater and plug top complete all as specified and directed
S&F in replacement 15 amp plug top 3 pin including making electrical connection with existing cable complete all as specified and directed by Engr-in charge.
S&F in replacement metal clad top 2 pole and earth 20 amp including connection complete all as specified and directed by Engr-in charge.
S&F in eplacement fusible plug (PRV) in 25/35/50 ltr capacitty electric water heater in existing location complete and testing complete all as specified and directed by Engr-in charge.
S&F in replacement base assy gasket in 25/35/50 ltr capacity electric water heater in any shape and size complete all as specified and directed
Supply and fix in replacement safety valve suitable for 25 ltrs / 50 ltrs capacitty geysers complete all as specified and directed
S&F bib tap cast copper alloy chromium plated with crutch handle screwed down, screwed for iron pipe or brass ferrule 15mm bore fixed in repair complete all as specified and directed by Engr-in charge.
Supply and fix in replaceemnt stop valves 15mm dia, cast copper alloy fency type chromium plated screwed pressure, with crutch of buterfly hndle, screwed both ends for iron pipe for unions and fixed all as specified.
Supply and fix in replacement fastner bolt as per site requirement where is required complete all as specified and directed by Engr-in charge.
Supply and fix in replacement non return valve 15mm di pipe brass made ISI marked, complete all as specified and directed by Engr-in charge.
Taking up or down steel tubing 15mm/ 20mm bore with fitting and for cleaning including refixing/ removing from the site complete all as specified and directed by Engr-in charge.
S&F, cutting and threading complete to walls and ceilings or laid in floors and as per site requirment 15mm bore GI tubing medium grade screwed and socket joint complete with all fittings such as bend socket , tees elbow union berral nipple plug etc on walls and ceiling with necessary GI clamps etc complete all as specified and directed by Engr-in charge. NOTE- The tenderer in his required tender shell include cost of scaffolding for fixing GI tubing in high rise bldg & multistoried bldg.
S&F GI nipple double threaded including socket minimum 1" long complete all as specified and directed by Engr-in charge.
S&F switch socket combination 2 in 1, 3/5 pin, 5/16 amp flush type universal complete all as specified and directed by Engr-in charge.
DEV RAJ MAGOTRA
M/S PRAJAPATI ENGINEERS
ARNABH ASSOCIATES
M/S BHARAT LIGHT ELECRIC.CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .