Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAdmitted-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | ₹41.5 L | L1 | Admitted-Finance |
| 2 | L2₹43.2 L+₹1.7 L (4.17%)Admitted-Finance | ₹43.2 L+₹1.7 L (4.17%) | L2 | Admitted-Finance |
| 3 | L3₹48.2 L+₹6.7 L (16.1%)Admitted-Finance | ₹48.2 L+₹6.7 L (16.1%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S - KRUPA ELECTRICALS L1 | M/S Jaiprakash Electrical and Engineering Works L3 | kamadhenu Electricals L2 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for carrying out regular checking and maintanance of Diesel generating sets of 62.5 KVA capacity at 531 Pump House including connected alternator and control panels and carrying out routine 'A' check of the set complete for smooth functioning all as per manufacturer's instructions complete all as specified and as directed.
Notes for Item No 01 to 21 :-
(i) Control switches such as MCCB, Main switch, contactors and multi display meter shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings.
(ii) Servicing of DG set alongwith connected alternator and attached control panel including 'A' check of the Engine shall be carried out at regular intervels as specified and as directed by the Engineer-in-Charge and the contractor shall carry out periodical inspections during the maintenenace period and he shall be responsible for the smooth functioning of the DG set all the time.
(iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only item and cost of labour for fixing these spares shall be deemed to be included in the rate quoted for this item
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item.
(v) The contractor shall also attend to the breakdown calls and depute necessary technician for repair/maintenence works as and when required with out delay during the maint period.
(vi) List of checks to be carriedout under 'A' check (Daily Routine Check) as below.
'A'- Check:- (1) Check oil level. (2) Check cleanliness of DG. (3) Check battery voltage. (4) Check any Leakage. (5) Check all filter condition. (6) Check coolant level. (7) Check V-Belt condition. | 10 | Per Month | 400 ₹4,000 Lowest | 1,000 ₹10,000 | 465 ₹4,650 |
| 2.00 | All as per item No 1 above but for diesel generating sets of 100 KVA capacity at TB-IV (North) pump house complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 1,000 ₹10,000 | 465 ₹4,650 |
| 3.00 | All as per item No 1 above but for diesel generating sets of 82.5 KVA capacity at FIU Lab complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 1,000 ₹10,000 | 465 ₹4,650 |
| 4.00 | All as per item No 1 above but for diesel generating sets of 100 KVA capacity 598 PH complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 800 ₹8,000 | 450 ₹4,500 |
| 5.00 | All as per item No 1 above but for diesel generating sets of 40 KVA capacity at AT RECORD ASC College complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 800 ₹8,000 | 450 ₹4,500 |
| 6.00 | All as per item No 1 above but for diesel generating sets of 30 KVA capacity at 100 MAP Domlur complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 700 ₹7,000 | 450 ₹4,500 |
| 7.00 | All as per item No 1 above but for diesel generating sets of 30 KVA capacity at EME WORKSHOP College complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 700 ₹7,000 | 450 ₹4,500 |
| 8.00 | All as per item No 1 above but for diesel generating sets of 30 KVA capacity at Meeret Block complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 500 ₹5,000 | 450 ₹4,500 |
| 9.00 | All as per item No 1 above but for diesel generating sets of 25 KVA capacity at TB-IV PH (N) complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 500 ₹5,000 | 450 ₹4,500 |
| 10.00 | All as per item No 1 above but for diesel generating sets of 20 KVA capacity at 70 MAJ MAP Ph complete all as specified and directed. | 10 | Per Month | 400 ₹4,000 Lowest | 1,000 ₹10,000 | 450 ₹4,500 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
21 Aug 2026, 6:50 pmClosed
GE (Central) Bangalore
GE (CENTRAL) BANGALORE AGRAM POST BANGALORE KARNATAKA-560007
MAINT/REPAIR/REPLACEMENT OF STREET LIGHT TIMER SWITCH CONNECTED CABLES AND OTHER WORKS AND REPAIR/MAINT OF DG SETS SOLAR HOT WATER AND BLOWER MOTORS PANELS MCCBs CABLE AND CONNECTED ITEMS AT AREA UNDER GE (CENTRAL) BANGALORE
2026_MES_780862_1
8662E
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
ASC CENTRE AND COLLEGE BANGALORE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE CENTRAL BANGALORE
₹86,000
Yes
25 Aug 2026
25 Jul 2026
24 Aug 2026
25 Jul 2026
21 Aug 2026
8 Aug 2026
25 Jul 2026 - 8 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for carrying out regular checking and maintanance of Diesel generating sets of 62.5 KVA capacity at 531 Pump House including connected alternator and control panels and carrying out routine 'A' check of the set complete for smooth functioning all as per manufacturer's instructions complete all as specified and as directed.
Notes for Item No 01 to 21 :-
(i) Control switches such as MCCB, Main switch, contactors and multi display meter shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings.
(ii) Servicing of DG set alongwith connected alternator and attached control panel including 'A' check of the Engine shall be carried out at regular intervels as specified and as directed by the Engineer-in-Charge and the contractor shall carry out periodical inspections during the maintenenace period and he shall be responsible for the smooth functioning of the DG set all the time.
(iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only item and cost of labour for fixing these spares shall be deemed to be included in the rate quoted for this item
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item.
(v) The contractor shall also attend to the breakdown calls and depute necessary technician for repair/maintenence works as and when required with out delay during the maint period.
(vi) List of checks to be carriedout under 'A' check (Daily Routine Check) as below.
'A'- Check:- (1) Check oil level. (2) Check cleanliness of DG. (3) Check battery voltage. (4) Check any Leakage. (5) Check all filter condition. (6) Check coolant level. (7) Check V-Belt condition. | 10 | Per Month | - | - |
| 2 | All as per item No 1 above but for diesel generating sets of 100 KVA capacity at TB-IV (North) pump house complete all as specified and directed. | 10 | Per Month | - | - |
| 3 | All as per item No 1 above but for diesel generating sets of 82.5 KVA capacity at FIU Lab complete all as specified and directed. | 10 | Per Month | - | - |
| 4 | All as per item No 1 above but for diesel generating sets of 100 KVA capacity 598 PH complete all as specified and directed. | 10 | Per Month | - | - |
| 5 | All as per item No 1 above but for diesel generating sets of 40 KVA capacity at AT RECORD ASC College complete all as specified and directed. | 10 | Per Month | - | - |
| 6 | All as per item No 1 above but for diesel generating sets of 30 KVA capacity at 100 MAP Domlur complete all as specified and directed. | 10 | Per Month | - | - |
| 7 | All as per item No 1 above but for diesel generating sets of 30 KVA capacity at EME WORKSHOP College complete all as specified and directed. | 10 | Per Month | - | - |
| 8 | All as per item No 1 above but for diesel generating sets of 30 KVA capacity at Meeret Block complete all as specified and directed. | 10 | Per Month | - | - |
| 9 | All as per item No 1 above but for diesel generating sets of 25 KVA capacity at TB-IV PH (N) complete all as specified and directed. | 10 | Per Month | - | - |
| 10 | All as per item No 1 above but for diesel generating sets of 20 KVA capacity at 70 MAJ MAP Ph complete all as specified and directed. | 10 | Per Month | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
8662TENDER.pdf
Tender Documents • 0.74 MB
BOQ_874734.xls
BOQ • 1.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .