Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAdmitted-Finance | ₹17.3 L | L1 | Admitted-Finance |
| 2 | L2₹17.5 LAdmitted-Finance | ₹17.5 L | L2 | Admitted-Finance |
| 3 | L3₹18.1 LAdmitted-Finance | ₹18.1 L | L3 | Admitted-Finance |
| 4 | L4₹18.8 LAdmitted-Finance | ₹18.8 L | L4 | Admitted-Finance |
| 5 | L5₹19.2 LAdmitted-Finance | ₹19.2 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | IMPLA GENERAL SUPPLIERS L2 | M/S SYED YAQOOB CONSTRUCTIONS L4 | M/S TANTRAY ELECTRICALS L5 | M/S WATT ELECTRICAL CONTRACTS L3 | A One Engineers L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00Permanent restoration of 33 KV Budgam - Sidco Line. | ||||||||
| 2.00 | Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation 410 SP56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 29 | No | 26,000 ₹7.5 L | 26,900 ₹7.8 L | 26,900 ₹7.8 L | 26,786 ₹7.8 L | 26,000 ₹7.5 L |
| 3.00 | Providing and fixing of fabricated GI V cross arm with top bracket, Channel X-arm including belting, clamps and braces angle iron as per site reqirement. | 878 | kg | 130 ₹1.1 L | 130 ₹1.1 L | 140 ₹1.2 L | 121 ₹1.1 L | 110 ₹96,580 |
| 4.00 | Providng,Laying,stringing ,tensioning and binding of 100 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any). | 4.63 | Km | 1,20,000 ₹5.6 L | 1,10,000 ₹5.1 L | 1,45,000 ₹6.7 L | 1,21,212 ₹5.6 L | 95,000 ₹4.4 L |
| 5.00 | Providing and fixing of PG Clamps for 100 mm² ACSR Conductor. | 39 | No | 200 ₹7,800 | 350 ₹13,650 | 300 ₹11,700 | 75 ₹2,925 | 200 ₹7,800 |
| 6.00 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm | 87 | No | 650 ₹56,550 | 700 ₹60,900 | 600 ₹52,200 | 777 ₹67,599 | 390 ₹33,930 |
| 7.00 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting | 18 | No | 400 ₹7,200 | 1,050 ₹18,900 | 990 ₹17,820 | 777 ₹13,986 | 800 ₹14,400 |
| 8.00 | Providing and fixing of Gavanized Nuts & Bolts with washers of sorts as per site requirements. | 29 | kg | 120 ₹3,480 | 140 ₹4,060 | 145 ₹4,205 | 121 ₹3,509 | 130 ₹3,770 |
| 9.00 | Providing and fixing of Danger Plates with clamps of standard make | 29 | No | 150 ₹4,350 | 250 ₹7,250 | 100 ₹2,900 | 555 ₹16,095 | 150 ₹4,350 |
| 10.00 | Providing and fixing of Anti Climbing Devices with clamps of standard make | 29 | No | 150 ₹4,350 | 250 ₹7,250 | 100 ₹2,900 | 555 ₹16,095 | 200 ₹5,800 |
Tender Value
₹19.6 L
EMD Value
₹39,100
Closing Date
15 May 2026, 4:30 pmClosed
Executive Engineer, STD-II, Rajbagh,Srinagar
Office of the Executive Engineer, STD-II, Rajbagh
Permanent restoration of 33 KV Budgam Sidco Line
2026_PDD_308477_1
STD-II / 07 of 2026-27 Dated 21-04-2026
Open Tender
Electrical Works
Budgam
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, STD-II, Rajbagh,Srinagar
₹39,100
18 May 2026
23 Apr 2026
16 May 2026
23 Apr 2026
15 May 2026
23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Permanent restoration of 33 KV Budgam - Sidco Line. | - | - | - | - | BI01010001010000000000000515BI0100001115 |
| 2 | Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation 410 SP56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 29 | No | - | - | BI01010001010000000000000515BI0100001116 |
| 3 | Providing and fixing of fabricated GI V cross arm with top bracket, Channel X-arm including belting, clamps and braces angle iron as per site reqirement. | 878 | kg | - | - | BI01010001010000000000000515BI0100001117 |
| 4 | Providng,Laying,stringing ,tensioning and binding of 100 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any). | 4.63 | Km | - | - | BI01010001010000000000000515BI0100001118 |
| 5 | Providing and fixing of PG Clamps for 100 mm² ACSR Conductor. | 39 | No | - | - | BI01010001010000000000000515BI0100001119 |
| 6 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm | 87 | No | - | - | BI01010001010000000000000515BI0100001120 |
| 7 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting | 18 | No | - | - | BI01010001010000000000000515BI0100001121 |
| 8 | Providing and fixing of Gavanized Nuts & Bolts with washers of sorts as per site requirements. | 29 | kg | - | - | BI01010001010000000000000515BI0100001122 |
| 9 | Providing and fixing of Danger Plates with clamps of standard make | 29 | No | - | - | BI01010001010000000000000515BI0100001123 |
| 10 | Providing and fixing of Anti Climbing Devices with clamps of standard make | 29 | No | - | - | BI01010001010000000000000515BI0100001124 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Tendernotice_2.pdf
PDF • 1.58 MB
BOQ_999627.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid