Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹19.8 L+₹3.3 L (20.1%)Rejected-Finance | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹23.9 L+₹7.3 L (44.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1. | |
| 4 | L4₹23.9 L+₹7.4 L (44.6%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L4 | Rejected-Finance Other than L1. | |
| 5 | L5₹29.8 L+₹13.3 L (80.3%)Rejected-Finance | L5 | Rejected-Finance Other than L1. |
Tender Value
₹29.9 L
EMD Value
₹59,860
Closing Date
30 Dec 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 WKS ENGR PIN 914134 CO 56 APO
REPAIR MAINT OF 11 KV AND 33 KV HT ELECT INSTALLATIONS INCL CONNECTED ITEMS SUCH AS TRANSFORMERS VCBS AVR CT PT GOD DO FUSES CONTROL CABLES ETC AT MANASBAL UNDER GE 970 EWS
2023_MES_630808_1
134WE-47 (T) OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 970 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹59,860
Yes
27 Jan 2024
2 Dec 2023
2 Jan 2024
2 Dec 2023
30 Dec 2023
16 Dec 2023
2 Dec 2023 - 9 Dec 2023
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, laying of cables, erection of poles, stays etc. and getting out in hard/ dense soil, complete all as specified and directed.
Excavation in trenches, not exc 1.5 mtr wide and exc 1.5 mtr but not exc 3.0 mtr in depth for foundation, erection of poles, stays etc. and getting out in hard/ dense soil, complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured and paid.
M&L for sub class 'B' brick, old size, as in covering protection to the eletric cable, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed.
M&L for replacement of 80mm bore GI tubing, medium grade, laid in trenches, road crossing, cable protection or fixed to walls with suitable MS clamps, complete all as specified and directed.
All as per Ser item No 7.00 here-in-before but 100mm bore pipe.
Dismantling of existing old unserviceable ACSR conductors of any size and type and S&F new ACSR conductors including stringing through existing RCC/ steel poles, fixing in insulators, jumpers with polythene pipes and aluminium binding wire etc, complete of all as specified and directed. Note :- Rates for alumnium tape, binding wire shall be deemed to include in quoted rates.
S&F in repair/ replacement mild steel cross arms, channels, bracing, supports, clamps etc, fabricated from structured steel, sections including nuts, bolts, washers etc and cutting to required length, bent to shape, drilling holes, fixed on poles or jointed by means of electric welding complete including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer after preparation of surface, complete all as specified and directed.
S&F in replacement disc type insulator, porcelain vitreous, brown or white, suitable for 33 KV HT working pressure of size 145mm height x 255mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous, brown or white insulator, suitable for 33 KV HT of working pressure of size 150mm height x 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in repair/ replacement cable jointing kit for 11KV grade cable for outdoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.
S&F in repair/ replacement cable jointing kit for 11KV grade cable for indoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.
S&F in repair/ replacement cable jointing kit for 11KV grade cable for straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE HT cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor, 11000 Volts grade (earthed) of size 3 Core 120 Sqmm, laid in trenches / floor / duct / fixed on poles through GI tubing in different locations/ areas, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE HT cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor, 11000 Volts grade (earthed) of size 3 Core 95 Sqmm, laid in trenches / floor / duct / fixed on poles through GI tubing in different locations/ areas, complete all as specified and directed.
S&F in replacement post insulator, suitable for 33 KV HT, working pressure in GOD / DO arrangements of any description, complete all as specified and directed.
Repairing / Servicing the air break isolating switch of HT 33 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts, nuts etc, complete all as specified and directed. Notes :- Major spare parts shall be measured and paid seperately under relevant items of BOQ.
Supply only following 33 KV Air Break Switch spares, complete all as specified and directed :-
Male contact/ moving contact blade.
Female contact / fix contact jaw.
Rotating contactor pipe for upto 200/400 Amps.
MS jumper carrier.
Back connector plate.
S&F in replacement drop out (DO) fuse unit expulsion type, outdoor, three pole, 200 Amp suitable for HT 33 KV, comprising of insulators, steel base mounting frame, GI nut bolts etc with 30A, HT barrel type fuse, complete all as specified and directed.
S&F in replacement including testing and commissioning of (GOD) gang operated type air break isolating switch, horizontal / vertical type mounting complete, double break and operation rod of suitable length 400 Amps capacity and suitable for 33 KV HT supply, complete all as specified and directed.
S&F in replacement including testing and commissioning of (GOD) gang operated type air break isolating switch horizontal / vertical type mounting complete, double break and operation rod of suitable length 400 Amps capacity and suitable for 11 KV HT supply, complete all as specified and directed.
S&F in replacement lighting arrestor, zinc oxide gap less type, station class suitable for 33 KV /10 KA, complete with all fittings, complete all as specified and directed.
M&L for preparation of old painted surfaces of HT 33 KV MRS at Manasbal consisting of steel poles / ISMBs, chain link fencing, cross arms, GOD pipe, clamps etc. having of any description and applying one coat of aluminium paint by manually, complete all as specified and directed. Notes :- (a) The rates inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b) The painting work will be carried out during Holidays only to avoid electric shut down.
Removing of vegitation, grass, scrubs and bushes growing in sub station yard along with fencing by manually / mechanically and keep the sub station yard neat and clean, complete all as specified and directed. Notes :- (a) Unit rates quoted deemed to be include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. (b) Neccesary tools shall be arrange by the contractor without any extra cost to Govt.
S&F in replacement including testing of metering & protection current transformer oil filled, outdoor type of 33 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA including dismantling old existing CT, complete all as specified and directed. Note :- Required and necessary setting including testing on completion shall be carried out till satisfaction of Engineer-in-Charge.
Dismantling old and burnt out PT unit, 33000/110/220 volts, oil filled, outdoor type, taking out contact with lead and bushing from the bus bar and replacing by new one of same model, suitable for 33 KV PT Unit incl testing on completion, complete all as specified and directed.
Taking down carefully the existing 11 KV/ 433 V distribution transformer of capacity 100 KVA to 500 KVA by disconnecting HT overhead connection/ underground cables and earth strips etc. from any sub station/ locations using suitable capcity of crane or by any other method irrespective of type of approach available, loading in vehicle, transport to workshop for repair and unloading carefully. Reloading the transformer after repair and testing, transport to site and unloading including placing at given position and re-commissioning, complete all as specified and directed by Engineer-in-Charge. Note :- All the T&P required for disconnection, loading and unloading including necessary petty items such as bolts, nuts, washers etc shall be arranged by the contractor and rates for the same deemed to include in the quoted rates.
M&L for repair of transformer step down 11 KV / 0.433 KV of any type of capacity 100 KVA to 250 KVA after dismantling the transformer body carefully, opening the top cover of transformer for inspection / repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/ sludge deposit in transformer housing core, renewal/ replacement of unsv rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nuts and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside by weather proof type using spray gun, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, re-filling of dehydrated transformer oil including dehydration, re-installing the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, meggering the LT and HT side of the transformer and testing, complete all as specified and directed. Note :- Winding wire for making of coils and LT/ HT bushes shall be measured & paid separately under respective item of BOQ.
All as per Ser item No 30.00 here-in-above but capacity of transformer 250 to 500 KVA.
Supply and filling of fresh transformer power oil of BDV not less than 60 KV for topping up of reduced level of transformer due to evaporation/ leakage/ losses due to dehydration in HT 33 KV transformer/ distribution transformer 100 to 500 KVA or for replacement complete including removing of old unservicable transformer oil, complete all as specified and directed. Note :- Proper document should be maintained by the contractor.
M&L for conducting oil filtration by stream line/ vacuum type filter machine to remove the moisture/ carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer incl routine testing after filtration for any capacity of transformers/ CT/ PT units, complete all as directed. Note :- The contractor shall be change the filter assy before starting the filtration of power/ distribution transformer of any capacity in presence of Engineer-in-Charge.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 300 KVA transformer, complete all as specified and directed.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 500 KVA transformer, complete all as specified and directed.
M&L for super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding the HT/ LT transformer/ VCB of any capacity and any make, complete all as specified and directed.
M&L for servicing of 33 KV VCB/ 11 KV VCB/ bus coupler by dismantling, cleaning, greasing the complete VCB with attached relays bus bar etc. insulation testing, setting the contact gap by measuring as required re-assembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning, complete all as specified and directed. Note :- New spares parts shall be measured and paid separately under respective items of BOQ.
M&L for carrying out primary & secondary injection test of 33 KV or 11 KV indoor / outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning including submitting the test report, complete all as specified and directed. Notes :- (a) PIT/SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid and considered as one unit. (b) Proper document should be maintained by the contractor.
Supply and fixing in replacement of the following spares for outdoor VCB 33 KV 800 A 750 MVA fault level 36V-26/2000 & VCB 11 KV 400 A 25 KA 250 MVA, complete all as specified and directed.
Closing coil 24/30V DC .
Tripping coil 24/30V DC.
Antipumping device 24/30V DC.
33 KV porcelain bushing for VCB Top.
33 KV porcelain bushing for VCB bottom.
Earth Fault and over current relay of L & T Model No MC31A 24-110V.
Digital type power factor indicator meter.
Digital type Voltmeter / Ammeter 96 x 96 mm size.
LED type indicator lamp assembly.
Spout incoming side.
Spout outgoing side.
Epoxy insulators bushings for incoming / out going cables / bus bar suppors as per existng size of VCBs.
Gear system assy complete with handle for charging / discharging of VCBs.
Spring charging motor for VCBs.
M&L for carrying out servicing or repair / maintenance of AVR by disconnecting electric connection, nuts bolts etc and checking AVR & buck booster and its connection like motor, rollers, contactors, carbon bush assembly or any other part as directed and required for proper functioning of buck booster at site complete and re-fixing in same position, complete all as specified and directed. Notes :- (a) All T&P required for disconnection, connection and minor spare not mentioned here-in-before including necessary petty items such as nuts, bolts etc. shall be arranged by the contractor and rates for the same shall be deemed to include in quoted rates. (b) Spares like carbon roller, bush assembly etc. if replaced, shall be measured and paid separately under respective items of this BOQ.
S&F roller and contactor of HT AVR 1000 KVA of make and model as required at site, complete all as specified and directed.
S&F carbon bush assembly with fibre glass carrier and contactors of HT AVR 1000 KVA of make and model as required at site, complete all as specified and directed.
Notes :- An amount of Rs. 3,22,520.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
M/S Noor Mohammad Shalla
M/S N A Enterprises
JK BUILDERS AND ENGINEERS
M/s Habib Electronics
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .