Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.3 Cr+₹11.1 L (9.37%)Rejected-Finance | ₹1.3 Cr+₹11.1 L (9.37%) | L2 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
26 Nov 2020, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura Cantt
SPL REPAIRS TO BLDG NO P-68 (FAMILY WING) OF MH MATHURA UNDER GE (EAST) MATHURA
2020_MES_367990_2
CWE/MTR/E/34 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Mathura
Class B cat a (i)
7 documents required · 7 mandatory
₹1,000
GE (East) Mathura
₹2.2 L
Yes
23 Jan 2021
13 Nov 2020
28 Nov 2020
13 Nov 2020
26 Nov 2020
14 Nov 2020
Amount
Chipping of unsound / weak concrete material of 25-50mm average thickness from slabs, beams, columns etc with manual chisel and or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc and disposal of debris for all lead and lifts complete all as specified and directed.
Chipping of unsound / weak concrete material of upto 25mm average thickness from slabs, beams, columns etc with manual chisel and or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc and disposal of debris for all lead and lifts complete all as specified and directed.
Cleaning of rust from the reinforcing bars upto 12mm dia to give it a total rust free steel surface by using alkaline chemical rust remover of approved make Fosroc reebaklens RR or equivalent in SIKA / THERMAX / FOSROC with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry complete all as specified and directed.
Cleaning of rust from the reinforcing bars above 12mm dia to give it a total rust free steel surface by using alkaline chemical rust remover of approved make Fosroc reebaklens RR or equivalent in SIKA / THERMAX / FOSROC with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry complete all as specified and directed.
Providing mixing and applying over reinforcement bars zinc antirust agent as per specification of make 'Fosroc Nitozinc Primer STD Base' or equivalent in SIKA / Thermax / FOSROC complete all as specified and directed.
Drilling suitable holes for upto and including 12mm dia bar in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades / balconies including fixing the steel bars as in additional main / distribution bars / stirrups / sheer connector in position using epoxy resin anchor grout of approved make complete all as specified and directed. Note : Reinforcement shall be measured and paid separately.
Drilling suitable holes for above 12mm dia bar in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades / balconies including fixing the steel bars as in additional main / distribution bars / stirrups / sheer connector in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement complete all as specified and directed. Note : Reinforcement shall be measured and paid separately.
Providing mixing and applying bonding coat of Epoxy bonding adhesive having coverage 2.20 Sqm/Kg of approved make 'Fosroc' the Nito bond EP chemical or equivalent of SIKA / THERMAX / FOSROC approved adhesive on chipped portion of RCC complete all as specified and directed.
Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast complete all as specified and directed.
M&L guniting / shotcreting RCC columns, beams and slabs etc in layers 0-25mm thick (total thickness) in grade M-25 with cement content not less than 350 Kg per cum with approved design mix concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc complete all as specified and directed.
M&L guniting / shotcreting RCC columns, beams and slabs etc in layers 115mm thick (total thickness) in grade M-25 with cement content not less than 350 Kg per cum with approved design mix concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc complete all as specified and directed.
M&L guniting / shotcreting RCC columns, beams and slabs etc in layers 140mm thick (total thickness) in grade M-25 with cement content not less than 350 Kg per cum with approved design mix concrete having the specified minimum characteristic compressive strength (with ordinary portland cement coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc complete all as specified and directed.
M&L guniting / shotcreting RCC columns, beams and slabs etc in layers 160mm thick (total thickness) in grade M-25 with cement content not less than 350 Kg per cum with approved design mix concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc complete all as specified and directed.
M&L guniting / shotcreting RCC columns, beams and slabs etc in layers 60mm thick (total thickness) in grade M-25 with cement content not less than 350 Kg per cum with approved design mix concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc complete all as specified and directed. Note for item No 10 to 14 :- (i) Guniting / Shotereting shall be carried out as per IS 9012 of 1978. (ii) Rates shall include the providing necessary ground wires etc payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument.
S&F mild steel TMT bars as in reinforcement 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel (wire) annealed not less than 0.9mm dia complete all as specified and directed.
S&F mild steel TMT bars as in reinforcement 8-10mm dia cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel (wire) annealed not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified and directed.
M&L use and waste of proping of suspended slabs such as roof slab floor slab landing and similar work not exceeding 200mmthick (horizontal or slope) during the whole process of retrofitting. One jack at each 1 Sqm area to be propped before starting the chipping work and shall be removed after completion of curing work complete all as specified and directed. Note for structural work (Srl item No 1 to 17) : (i) Work has to be carried upto two storey buildings and nothing extra shall be paid to contractor on this ground. (ii) Digital photo / videography for all items of structural strengthening shall be done by the contractor in presence of JE (Civ) / Engineer-in-Charge. Copy of CD thereof shall be deposited to Engineer-in-Charge for record on completion of each stage as elaborated here-in-above. (iii) Cement used for the structural repair / rehabilitation work shall be of OPC grade.
M&L for 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in Sub base of ground floors complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar (1:3) on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on fair face of brick walls / concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15mm thick on brick work or concrete surfaces finished even and fair in CM 1:4 mixed with liquid water proofing compound as per manufacturer's instruction complete all as specified and directed. (liquid WPC shall be measured and paid separately)
Supply only liquid water proofing compound Dr Fixit or equivalent complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of wall and applying two coats of exterior emulsion paint of make : weather coat of Berger / apex ultima of Asian paints / Extrapremium of Shalimar, over and including a coat of exterior wall primer complete all as specified and directed. Note : The work under this item shall be carried out by contractor from authorised applicator of manufactrurer by using modern technique. The contractor shall also furnish gaurantee of the quality and finish work under this item for a period of five years from certified date of completion of complete work for which an amount ₹ 20/Sqm of quantity of work done under this item shall be retained in final bill. This amount shall be returned only after completion of gaurantee period.
M&L two coats of Oil bound distemper on new plastered surfaces over and including a coat of alkali resistant primer on walls including preparation of surfaces complete all as specified and directed. Note : The work under this item shall be got carried out by contractor from authorised applicator of manufactrurer by using modern technique.
Demolition of brick work built in cement mortar including all quoins, arches pillars etc complete all as specified and directed.
M&L for brick work with old size Fly Ash bricks straight or curved on plan exc 6mtr mean radius, built in CM (1:6) complete all as specified and directed.
M&L brick work with Fly Ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for 50mm thick PCC (1:3:6) type C-1 (Using 20mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement including filling the joints by bitumen and sand mixed in the ratio 1:3 by weight complete all as specified and as directed.
Taking down existing roof treatment any description and any thickness complete all as specified and directed.
M&L for Providing, cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L for preparing cement concrete / RCC roof surfaces and providing 10mm thick modified plaster in CM 1:4 cement mixed with polymer in ratio of 1:10 (1 part of polymer and 10 parts of cement) applying priming coat of epoxy primer with resin and hardener with water dilution as per manufacturer instructions, applying two coats of solvent based polyurethane liquid membrane each coat not less than 500 micron thick UV stable having SRI value greater than or equal to 105 with consumption of 0.61 Kg/Sqm (each coat), 2nd coat should be applied once 1st coat is fully dried complete all as specified and directed. Make : Sika / Fosroc / Thermax or equivalent make as approved.
Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking up or down steel water tubing and connection of 15mm bore complete all as specified and directed.
Taking up or down steel water tubing and connection of 20mm bore complete all as specified and directed.
M&L Cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; for concealed water tubing etc and making good, cutting not exc 10cm girth complete all as specified and directed. Note : The cutting of chases will be done using wall chaser / wall groove cutting machine only.
S&F GI tubing 15mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed.
S&F GI tubing 20mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed.
S&F in repair gun metal globe or gate valves 20mm bore with iron wheel head, screwed both ends for iron pipes and fixed for 20mm bore of pipes complete all as specified and directed.
S&F in repair brass chromium plated shower rose with or without swivel joint 75 mm size complete all as specified and directed.
S&F chromium plated shower arm 15mm dia, 195mm long with bend of 45 degree with flange of any colour complete all as specified and directed.
S&F in repair bib taps 15mm bore fancy type chromium plated long body cast copper alloy with crutch of butterfly handle screwed down for iron pipe complete all as specified and directed.
S&F in repairs Vitreous China wash hand basin, white, flat back, size 550x400mm including CI brackets, CP brass waste coupling 32mm bore with long screwed shank and fly nut complete all as specified & directed.
S&F in repair stop valves / angular valve cast copper alloy with crutch or butterfly handles screwed down high pressure, screwed both ends for 15mm bore iron pipe or brass ferrule complete all as specified and directed.
S&F PVC connection 15mm size, of length 450mm, with PTMT nuts complete all as specified and directed.
S&F 32mm bore PVC waste pipe 75 cm long complete all as specified & directed.
S&F in repair stainless steel soap dish complete all as specified and directed.
S&F in repair stainless steel tubular towel rail 20mm dia 'D' type, 60cm long between flanges complete all as specified and directed.
S&F in repair 15mm bore chromium plated fancy type pillar taps cast copper alloy with capstan head screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair pillar cock with extended lever handle for Medical use complete fixed to wash hand basin / sink complete all as specified and directed. Make : Jaquar Cat part No FLR-5031N or equivalent make as specified in Appendix 'B'
S&F in repair Single lever Surgical purpose elbow action basin mixer with extended operating lever with 150mm long braided hoses complete all as specified and directed. Make : Jaquar Cat part No FLR-5033B or equivalent make as specified in Appendix 'B'
S&F in repair sheet glass shelf assembly consisting of 5.50 mm thick glass shelf 12cm wide with chromium plated guard and railing 60cm long complete all as specified and as directed.
S&F in repair, PVC low level cistern 10 lit capacity, valveless, syphonic action type with float, handle incl 32mm dia flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed.
S&F in repair vitreous china squatting pan "ORISSA" pattern size 580mm x 440mm, white with integral foot rest including cast iron 'P' or 'S' trap and connection to trap and to flushing pipe, anti-syphonage pipe, etc. complete all as specified & directed.
S&F in repair viterous China wash down water closet (pedestal pattern) complete connecting to flush pipe, including plastic seat cover white with flat bottom and mild steel chromium plated or aluminium hinging device (excluding flushing cistern and flushing pipe) complete all as specified and directed.
S&F in repair CP toilet paper holder fixing to wall complete all as specified and directed. Make : Jaquar Cat part No ACN-1151N or equivalent makes as specified in Appendix 'B'.
S&F in repair hand shower (Health faucet), ABS body with 8mm dia, 1.2 meter long flexible tube and wall hook complete all as specified and directed.
S&F in repairs 15 mm bore fancy type CP Angle cock two way cast copper alloy chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets angle iron 50x50x6mm with suitable length and connecting union to pipe, waste pipe, overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed. Note : ±10mm tolerance in size /dimension of sink is permissible as per standard manufacturers catalogues of makes mentioned in Appendix 'B')
M&L PVC water tank triple layer white in colour rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 1000 ltr with 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling of existing tank complete all as specified and directed.
S&F in repair PVC (SWR) floor trap plain with stainless steel grating including jointing with solvent cement with dia of outlet 75mm complete all as specified and directed.
S&F in repair 75mm PVC (SWR) type 'A' pipes single socketed, including fittings in any length with rubber ring joints laid in trenches complete all as specified and directed.
S&F in repair 110mm PVC (SWR) type 'A' pipes single socketed, including fittings in any length with rubber ring joints laid in trenches complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) type 'A' pipes single socketed, including fittings in any length with rubber ring joints fixed to wall including necessary clamp etc complete all as specified and directed.
S&F in repair 75mm PVC (SWR) type 'A' pipes single socketed, including fittings in any length with rubber ring joints fixed to wall including necessary clamp etc complete all as specified and directed.
Demolition and breaking up 150mm bore drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar including PCC haunching and bedding complete all as specified and directed.
Excavation in trenches in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and directed.
Removing excavated soil / material to a distance not.exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
Removing excavated soil / material to a distance exc 250m but n.exc 500m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
Removing excavated soil / material to a distance exc 1Km but n.exc 1.5Km and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
M&L for 150mm bore Reinforced concrete pipes class NP2 laid and jointed in cement with collars in trenches complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia pipe complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4, type B-1 (20mm graded aggregate) as in landing, cover slab (for manholes, soakage well etc) and similar articles with plain faces set in CM 1:6 including desmantling of old cover slabs complete all as specified and directed. Note : Reinforcement shall be measured and paid separately.
M&L for PCC 1:7:12 type F-2 using 40mm graded stone aggregate as in filling in sunken floor complete all as specified and directed.
M&L for providing damp proof layer in two coats of acrylic polymer coating consisting of one part of acrylic polymer liquid mixed with two parts of cementious powder applying at the rate of 1.40Kg/Sqm of mix per coat and applying second coat after 4-6 hrs of first coat, 5 days curing is to be carried out to the surface before plastering complete all as specified and directed. Note : (i) Make of material smart care damp block 2K of Asian paints or equivalent for Dr Fixit, STP, SIKA. (ii) The work under this item shall be got carried out by contractor from authorised applicator of manufacturer by using modern technique. The contractor shall also furnish gaurantee of the quality, finish work and effectiveness of water proofing treatment under this item for a period of ten years from certified date of completion.
Demolition of reinforced cement concrete as in chajjas and similar suspended work complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm & n.exc 4.00 sqm each complete all as specified and directed.
Taking down shutters of any description n.exc 1.00 sqm each and refixing in same opening after completion of structural repair complete all as specified and directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 sqm each and refixing in same opening after completion of structural repair complete all as specified and directed.
Taking down shutters of any description exc 2.00 sqm each and refixing in same opening after completion of structural repair complete all as specified and directed.
S&F Pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, size of frame 105 x 60mm complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) filling of pressed steel frame and hold fast block etc complete all as specified and directed.
S&F 30mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F factory made Solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelam sheet used instead of plain colour PVC sheet reinforced with MS square tubes, and edges will be painted to match with prelam sheet fixed in opening as per specification & drawing given in SSR Part-II 2010.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile), with particle board core and 2, 4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plain colour PVC sheet on back face, fixed in frame at site as per specification & drawing given in SSR part-II 2010 complete all as specified and directed.
S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 150mm long Aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F butt hinges 100mm extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 complete all as specified and directed.
S&F in repair Mild steel body mortice lock vertical type size 65mm, 4 levers complete all as specified and directed.
S&F Powder coated (thickness of poweder coating shall not be less than 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Powder coated (thickness of poweder coating shall not be less than 50 micron) aluminium door shutters, aluminium section weighing 0.55 kg/m including glazing clips, ruber neoprene packing, handles 2 Nos in each door, 03 Nos hinges each shutter, aluminum snap beading screws etc. complete all as specified and directed.
S&F powder coated (thickness of powder coating shall not be less than 50 micron) aluminium window and ventilator shutter, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as peg stays 150mm long (1 No.) hinges type B-21, 100mm long (2 Nos) suitable handle (1 No.) complete all as specified and directed.
S&F 5.5mm thick tinted glass, ordinary quality in square exc 0.5 sqm in each pane fixed with rubber bead jointing cleat for fixing in position for aluminium door, window / ventilators and leaving the panes clean complete all as specified and directed.
S&F 5.5mm thick tinted glass, ordinary quality in square not exc 0.5 sqm in each pane fixed with rubber bead jointing cleat for fixing in position for aluminium door, window / ventilators and leaving the panes clean complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staple complete all as specified and directed.
S&F 4mm thick figured glass, pin head type in squares n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F aluminium (die cast body) door closer hydraulically regulated designation No 1 universal type suitable for door shutter of 700 mm in width and of weight not more than 35 Kg complete all as specified and directed.
M&L in repairs double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Dismantling of boarding including grid any description fixed in any position complete all as specified and directed.
S&F anodised aluminium snap grid with size of grid 605x605mm frame work for false ceiling including hangers 6mm dia G.I (upto 1200mm long) adjusting level fixed to roof slabs with the help of cleats made out of G.I flat 40x3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long complete all as specified and directed.
S&F 4mm thick non-asbestos fibre cement building board having fire resistance & moisture resistance properly, fixed on aluminium grid ceiling with screws complete all as specified and directed.
Fixing only serviceable 4mm thick non-asbestos fibre cement building board fixed on aluminium grid ceiling with screws complete all as specified and directed.
S&F in repair stainless steel railing dia of upper pipe 50mm, height of railing 0.90m including bottom stops and decorative stops at bends and balusters complete all as specified and directed.
S&F in repair 18/19mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete all as specified and directed.
S&F continous piano hinges mild steel bright finish or electro galvanised of 30mm width of flaps (when open) complete all as specified and directed.
S&F for 0.9mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
S&F in repair 100mm size brass handles, cast type, polished bright complete all as specified and directed.
S&F 25mm size Magnatic catcher for cupboards including fixing to frame and connected plate to shutter complete all as specified and directed.
S&F in repair 25mm dia stainless steel drapery rod including stainless steel brackets and end caps fixed to wall with stainless steel screws complete all as specified and directed.
M&L for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
S&F framed work such as grills, gratings etc with ends of bars shouldered and riveted, framed guard bars and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling floor hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including cement mortar bedding but not backing including removal of debris to a destance exc 1.5 Km but n.exc 2 Km complete all as specified and as directed.
S&F coloured Non Skid ceramic tiles 7 to 8 mm thick, (Square / rectangular) area of each tile exceeding 0.06 Sqm but n.exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over and including 15mm thick screed bed in CM (1:4) complete all as specified and directed.
S&F light shade coloured vitrified ceramic tiles 10mm thick, (Square/ rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:4) complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 450 x 300 x 7mm thick as in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match the shade over and including 10mm thick rendering in cement mortar (1:3) complete all as specified and directed.
M&L for Mirror polishing to existing Kota stone flooring including shining the kota stone surface with mechanical scrubber and polishing complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar complete all as specified and directed.
M&L 20-25mm thick machine cut Kota stone slabs of size 550 x 550mm (minimum) over 20mm thick screed layer in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of stone incl rubbing & mirror polishing with mechanical scrubber complete all as specified and directed.
M&L for 20mm thick granite stone slab prepolished, machine cut (one piece) as in steps, jambs, pillars, window cills, cooking platforms and like laid over 20mm thick cement screed bed or bedding layer in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall after complete removal by mechanical scrapper and applying two coats of oil bound distemper complete all as specified and directed. Note : The work under this item shall be got carried out by contractor from authorised applicator of manufactrurer by using modern technique.
M&L for 25mm thick (measured solid) precast cement concrete louvers and jallies type B-0 mix 1:2:4 (using 12.5mm graded stone aggregate) including all mouldings but excluding frame set in CM 1:4 complete all as specified and directed.
M&L 5cm thick sand stone slab in sunshade, chajja's, shelves, cills landings cover stones etc n exc 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and directed.
S&F water heater storage type BEE 5 star rated 230 volt single phase electric vertical type high energy efficeient rust free ABS body with enhanced safety features corrosion resistant well coated certified durable heating element, stainless steel tank of capacity 25 ltr complete all as specified and directed.
Taking down carefully existing surface aluminium / copper point wiring with wooden battens / PVC conduit (light, fan, socket, bell or power) including fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators etc and making good disturbed surfaces complete all as specified and directed.
Taking down ceiling fan / exhaust fan / wall fan of any sweeps, sealing end of cable, dismantling fan and blades for reuse after carrying out repairs and Hanging ceiling fan / exhaust fan / wall fan of any sweep and connnecting up including provn of three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm copper wire from ceiling rose / connector to fan of length not less than 1.0 mtr complete all as specified and directed.
Taking down old unserviceable / burnt copper / aluminium submain wiring of any size including earth wire and making good of the disturbed surface and removing the material from site complete all as specified and directed.
Taking down old existing MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete all as specified and directed.
M&L for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 1.5 sqmm drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories, for mounting modular switches, sockets, fan regulators, including cutting, chasing on wall and other surfaces and making good disturbed surface using cement mortar 1:3 complete for the following :- Note : Modular boxes, modular face plate and modular plate cover shall be measured and paid separately.
One light / fan / bell point controlled by one switch.
One socket outlet three / five pin, 5 amp controlled by one switch on indepdendent board.
M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 2.5 sqmm drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories, with earth continuty conductor with FRLS PVC insulated multistranded copper conductor cable 2.5 Sqmm complete for mounting modular one 16 Amp socket outlet controlled by one switch on independent board, including cutting, chasing on wall and other surfaces and making the good disturbed surface using cement mortar 1:3 complete all as specified and directed. Note : Modular boxes, modular face plate and modular plate cover shall be measured and paid separately.
M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 4 sqmm drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories, with earth continuty conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 4 Sqmm complete for one 20 Amp AC enclosure on independent board, including cutting, chasing on wall and other surfaces and making the good disturbed surface using cement mortar 1:3 complete all as specified and directed.
S&F modular Switch 6 amp single Pole one way, one module 230 V complete all as specified & directed.
S&F modular Switch 16 amp single Pole one way, one module 230 V complete all as specified & directed.
S&F socket outlet modular type shutterd and interlocking flush type 230/250 volts grade for:-
Socket outlet 2 in 1, 6 Pin, 6 & 16 Amp two module
Socket outlet 2 in 1, 3 Pin 6 Amp and 2 pin 6 Amp two module
S&F ceiling rose of 65x50mm PVC / polycarbonate three terminal surface bakelite complete all as specified and directed.
S&F modular bell push, 6 Amp one module 230 V complete all as specified & directed.
S&F Bell multi music type AC 230 volt complete all as specified & directed.
S&F integrated type LED tube light fitting, indoor decorative aluminium extruded T-5, LED batten 4 feet integrated type housing with high lumen output energy efficient tubelight white complete of capacity 1x20 Watt including making electrical connections with twin core twisted flexible copper wire of suitable size complete all as specified and directed. Make : Cat Part No LTTB4F20WLED/W of C&S or equivalent make as specified in Appendix 'B'.
S&F LED bulk head fitting with PDC aluminium housing and milky diffuser of capacity 10W with lamp holder complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable suitable size of 230V, 50HZ complete all as specified and directed. Make : Cat Part No LTB10WLED of C&S or equivalent of CG / Havells.
S&F indoor decorative ultra slim surface / wall mounted T-5 LED batten tube light complete fitting 1x10 watt LED tube (size within 600 x 25 x 40mm) suitable for 2' long with polycarbonate diffuser & integrated electronic driver, energy efficient, 140V-270 volts complete with all accessories internally pre-wired and including connection up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Cat Part No LTTB2F10WLED/W of C&S or equivalent make as specified in Appx 'B'.
S&F decorative Wall light fitting made up of Polycarbonate with outer cover shape having Glove / Mars suitable for spiral B-22 base holder with including 10 Watt LED lamp complete with all accessories and including connection with twin core twisted flexible copper conductor cable suitable size complete all as specified and directed. Make : Havells Cat Part No LHDL06160099 or equivalent to Philips / Bajaj / CG
Supply and fixing Surface/recess mounitng LED 2x2 luminaire white powder coated CRCA full glow LED backlit panel, housing LEDs 30 watts. Seamless front frame with flat white high transmission acrylic cover including connecting up with twin core twisted flexible copper conductor cable suitable size complete all as specified and directed. Make : Cat Part No LTCSP30WLED2X2 of C&S or equivalent make as specified in Appx 'B'.
S&F sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosures with 2 pin and earth plug and socket complete with one SP MCB of 20 Amp rating 240 Volt complete all as specified and directed.
S&F lamp holder PVC polycarbobate type with back plate suitable for LED retrofit lamp and connecting up complete all as specified and directed.
S&F LED retrofit lamp B-22 holder base with polycarbonate diffuser and aluminium heat sink 7 Watt complete all as specified and directed. Make - Cat Part No LTHPLEDLAMP7W/B22 of C&S or equivalent make as specified in Appendix 'B'.
S&F ceiling fans BEE 5 Star rated of 1200mm sweep white in colour of Aluminium blades (three numbers) and body, double ball bearing, down rod, fan motor, pair of canopy shackle, assembly kit, etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete all as specified and directed. (Model : ES Neo of Havells or equivalent make as specified in Appx 'B') (Note : Old ceiling fan to be deposited in MES store)
S&F in repair metalic exhaust fans 300mm sweep AC single phase 230/240V with louver and all connected assessories complete all as specified and directed. Model : Turbo force SP of Havells or equivalent make as specified in Appx 'B' Note : Old exhaust fans to be deposited in MES Store.
S&F in repair wall mounting fan 400mm sweep AC single phase 230/240V and all connected assessories complete all as specified and directed. Model : Swing of Havells or equivalent make as specified in Appendix 'B'. Note : Old wall mounting fan to be deposited in MES Store.
M&L submain wiring with 4 runs of single core 6 Sqmm PVC insulated unsheathed multisranded 1100 volts grade with FRLS copper conductor drawn through and including ISI marks PVC conduit concealed and conduit accessories of medium grade not less than 25mm dia including one run of single core 6 Sqmm FRLS PVC insulated unsheathed multistanded 1100 volts grade with copper conductor cable as earth conductor along with wiring and connected from DB to DB / main board complete all as specified and directed. Note : Four run of 6 Sqmm cable and one run of 6 Sqmm earth cable and one run of 25mm PVC conduit shall be considered as a unit for measurements purpose.
M&L for submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with FRLS copper conductor drawn through and including ISI marks PVC conduit concealed and conduit accessories of medium grade not less than 20mm dia including one run of single core 4 sqmm FRLS PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth conductor along with wiring and connected from DB to DB / main board complete all as specified and directed. Note : Two run of 4 Sqmm cable and one run of 4 Sqmm earth cable and one run of 20mm PVC conduit shall be considered as a unit for measurements purpose.
M&L for submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheathed multistranded 1100 volts grade with FRLS copper conductor drawn through and including ISI marks PVC conduit concealed and conduit accessories of medium grade not less than 20mm dia including one run of single core 2.5 sqmm FRLS PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth conductor along with wiring and connected from DB to DB / main board complete all as specified and directed. Note : Two run of 2.5 Sqmm cable and one run of 2.5 Sqmm earth cable and one run of 20mm PVC conduit shall be considered as a unit for measurements purpose.
S&F factory made epoxy powder coated CRCA steel sheet distribution board (minimum thickness 1.6mm & constructed as per IS 8623) VTPN 6 ways (MCCB DB) degree of protection IP-43 - IK 09 with metal door recess mounted for 240 volts, fixed flush to wall, 200 Amp rated copper bus bar, earth bar, din bar top & bottom detachable gland plate, interconnection, earthing connection blanking plates in unused spaces complete all as specified and directed.
S&F factory made epoxy powder coated CRCA steel sheet distribution board (minimum thickness 1.6mm & constructed as per IS 8623) TPN 6 ways (MCCB DB) degree of protection IP-43 - IK 09 with metal door recess mounted for 240 volts, fixed flush to wall 200 Amp rated copper bus bar, earth bar, din bar top & bottom detachable gland plate, interconnection, earthing connection blanking plates in unused spaces complete all as specified and directed.
S&F MCCB four pole, 250 Amps 36 KA thermally adjustable between 70 to 100% including 4 spreader link set same make as that of MCCB for connection, required lugs etc complete all as specified & directed.
M&L for MCB TPN 415 volts, 63 Amps, 16KA, 'C'-Series complete all as specified and directed.
M&L for MCB TPN 415 volts, 100 Amps, 16KA, 'C'-Series complete all as specified and directed.
S&F factory made epoxy powder coated CRCA steel sheet MCB distribution board (minimum thickness 1.6mm & constructed as per IS 8623) degree of protection IP-43 - IK 09 with metal door recess mounted for 240 volts, single pole and neutral 8 way fixed flush to wall 200 Amp rated copper bus bar, earth bar, din bar top & bottom detachable gland plate, interconnection, earthing connection blanking plates in unused spaces complete all as specified and directed.
S&F factory made epoxy powder coated CRCA steel sheet MCB distribution board (minimum thickness 1.6mm & constructed as per IS 8623) degree of protection IP-43 - IK 09 with metal door recess mounted for 240 volts, single pole and neutral 4 way fixed flush to wall 200 Amp rated copper bus bar, earth bar, din bar top & bottom detachable gland plate, interconnection, earthing connection blanking plates in unused spaces complete all as specified and directed.
M&L for MCB SPN 240 volts, 40 Amps, 16KA, 'C'-Series complete all as specified and directed.
M&L for MCB SP 240 volts, 6-32 Amps, 16KA, C-Series complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways, MS handle 12mm dia for PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including taking out old existing earthing complete all as specified and directed. Note : The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
M&L for earthing complete with galvanized steel earth plate electrode size 600mm x 600mm x 6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. RCC cover with concrete (1:2:4) type B-1 using 8mm bars @ 100mm C/C both way with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion including taking down existing earthing complete all as specified & directed. Note : The unit rate includes for protection pipe and GI Earth strip 32 x 6mm from top of earth plate upto 7.5m above ground level.
M&L for modular metal flush box, 1 module complete all as specified and directed.
M&L for modular metal flush box, 2 module complete all as specified and directed.
M&L for modular metal flush box, 3 module complete all as specified and directed.
M&L for modular metal flush box, 4 module complete all as specified and directed.
M&L for modular metal flush box, 6 module complete all as specified and directed.
M&L for modular metal flush box, 8 module complete all as specified and directed.
M&L for modular white cover plate with frame, 1/2 module complete all as specified and directed.
M&L for modular white cover plate with frame, 3 module complete all as specified and directed.
M&L for modular white cover plate with frame, 4 module complete all as specified and directed.
M&L for modular white cover plate with frame, 6 module complete all as specified and directed.
M&L for modular white cover plate with frame, 8 module complete all as specified and directed.
S&F modular electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified and directed.
M&L for fabrication of cubical LT panel board outdoor type with double door made out of 3.15mm thick MS sheet, dust, vermin and water proof duly supported on 40 x 40 x 6mm angle iron frame, having locking arrangement at front and opening arrangement from front & rear both duly fitted with compression cable glands for entry & exit of cables, powder coated with two coats and having minimum clearance 450mm above ground level angle iron frame embeded in PCC 1:2:4 bed block size 30 x 30 x 30cm for each leg complete comprising of the following :- (i) Panel mounted multi-function for voltage, current, frequency, power factor and power type EM-VIFP - 01 Set. (ii) Al bus bar - 03 Nos. For phase of capacity 400 Amp and 01 Nos 400 Amp for neutral, duly taped in colour coded FRP sleeves. (iii) Indicating lamps Red, Yellow and blue in colour, LED type complete with lamp holders, 220 volts AC - 01 Set of 3. (iv) Panel wiring with 2.5 Sqmm PVC sheathed, PVC insulated FRLS stranded copper conductor cable through MCB DP 10A mounted on DIN rail. (v) 4 Pole MCCB 250 Amp, 415 V, 36 KA - 02 Nos (Main incoming & outgoing)
Supplying laying, jointing, testing and commissioning of XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade, cross sectional area 95 Sqmm 3.5 core complete including taking down existing unserviceable cable all as specified and directed. Note : cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc excavation, earthwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid separately.
Supplying and laying un-reinfoced precast concrete cable cover of class LV type 1 with flat size 250 x 150 x 40mm compete all as specified and directed.
M&L for sand cushioning to under ground cable in trenches / ducts in layers of 8cm deep before laying the cable and 15cm deep after laying and stretching the cable complete all as specified and directed. Note : Punned thickness shall be measured.
M&L for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall / pole for protection of cable / earthing strip etc complete all as specified and directed.
M/s Singh Engineering Corporation
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .