Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC | L1 | Accepted-AOC RATES ARE REASONABLE | |
| 2 | L2₹16.3 L+₹12,927 (0.80%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹16.5 L+₹31,293 (1.94%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹16.6 L+₹44,852 (2.77%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹16.6 L+₹46,645 (2.89%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
16 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 Works Engrs, c/o 99 APO
REPAIR AND MAINT OF TRANSFORMER, GOD, VCB, HT CABLE AND ALLIED WORKS AT PEDONG, ALGARAH, DALAPCHAND, RHENOCK AND RONGLI UNDER GE 867 EWS
2021_MES_452208_1
CWE/136-WE/13 OF 2021-22
Open Tender
Electrical and Maintenance Works
Works
180 days
GE 867 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE 867 EWS
₹30,000
Yes
27 Jul 2021
17 Jun 2021
17 Jul 2021
17 Jun 2021
16 Jul 2021
2 Jul 2021
17 Jun 2021 - 24 Jun 2021
60 days
Amount
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size including taking out old unserviceable rusted out danger plate complete all as specified and directed.
S&F of disc type insulator porcelain vitreous white brown or green as per IS 731-1963 of size 145 mm high and 255 dia ball and socket type single disc with tension clamp for working pressure 11000 volts complete all as specified and as directed.
S&F for pin type, porcelain, vitreous, white, brown or green insulator as per IS 731-1963 including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including funnel with GI Light grade watering pipe 20 mm bore, wire mesh charcoal and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50m complete all as specified and as directed.
M&L for painting of four pole structure by one coat of aluminium paint including preparation of steel surface for 4 pole structure (above planting depth) 11 metre long steel tubular pole and mild steel work i.e. cross arms, bracing, clamps,with painting Yellow and black strip 30 cm wide up to 1.5 Mtrs height from the copping level etc ccomplete all as specified and as directed. Note: Contractor should be taken necessary shutdown before painting work and should be present at sited during execution the work.
M&L for painting of two pole structure by one coat of aluminium paint including preparation of steel surface for 4 pole structure (above planting depth) 11 metre long steel tubular pole and mild steel work i.e. cross arms, bracing , clamps,with painting Yellow and black strip 30 cm wide up to 1.5 Mtrs height from the copping level etc ccomplete all as specified and as directed. Note: Contractor should be taken necessary shutdown before painting work and should be present at sited during execution the work.
M&L for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp working pressure 11000 volts complete all as specified and directed.
M&L for HT 11 KV (working pressure 11000 volts) Air break switch, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps including providing jelly for all moving and fixed contacts complete all as specified and as directed.
M & L for providing, cement concrete 1 : 2 : 4 type B1 using 20 mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessory form work finished fair using extra cement all as specified and as directed.
M & L for cement concrete 1 : 3 : 6 type C 2 using 40 mm graded stone aggregate for foundation of pole, stay, plinth of transformer, mass concrete etc all as specified and as directed.
Restringing of existing HT overhead line including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumpher and connections and reconnecting after tightning of conductor incl replacement of all jumpers all as specified and as directed. Note :- Single wire run of conductor in HT lines shall be measured as one lenght for payment purpose.
Filtration and dehydration of transformer oil to achieve test result as per IE rules with filtration plant all as specified and as directed. Note :- a) The filtration of transformer oil of various transformers is to be carried out at different sub stations of Rhenock & Rongli mil area. b) The report before filtration and after filtration to be submitted by contractor in the approved formates. c) The filtration is to be carried out on line ie without switching off supply.
Cleaning of old painting surfaces by cleaning agents including removing dirt, dust, oil, grease etc of transformer capacity 75 KVA to 200 KVA at different sub station and providing two coats of synthetic enameled spray paint including writing SM/MES/Machine Numbers all as specified and as directed.
Supply & Top up of transformer oil upto conservator level marking with new oil as per IS: 335 having dielectric strength not less than 40 KVA at 2.5 mm gap complete all as specified and as directed.
Rubbing / scratching old paint of transformer of capacity upto 200 KVA, through cleaning with kerosene oil and remove all oil stains, dust etc. providing two coats of synthetic enameled spray paint including writing SM/MES/Machine Numbers all as specified and as directed.
S&F in replacement under repair of silica Gel breather to conservator of oil filled Transformer as per existing type silica Gel breather complete all as specified and as directed.
Supply and fixing of earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried on ground or drawn in conduit pipe or fixed to poles or any other indicated situation for the loop earthing etc. as required of size 32 x 6 mm galvanized iron strip complete all as specified and as directed.
S & F of aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed.
M&L for cable jointing kit for HT 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE insulated armoured (heavy duty) aluminium conductor cable of cross sectional area 95 sqmm all as specified and as directed.
Supply laying. jointing, testing and commissioning of HT XLPE cable insulated, PVC Bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor conforming to IS:7098 (Part 2) 6.35 KV (UE)/11 KV (E) grade cross sectional area 95 sq mm 3 core complete all as specified and directed. Note:- Joint shall be measured and paid separatly.
Excavation in trenches/ foundation in soft / loose soil not exceeding 1.50m wide and not exceeding 1.50m deep for laying of HT under ground cable/ pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
M&L for sand cushioning to under ground cable in layers of 23cm thick (8 cm before laying the cable and 15 cm thick after laying the cable) in trenches complete all as specified and directed. Note :-Puned layers of 18 cm thick sand measured only.
Supply and laying unreinforced precast concrete cable cover, class HVP type 2, wtih peak size 450 mm 180 mm x 40 mm with minimum average breaking load 350kg as per IS 5820:1970, ISI marked all as specified and directed.
M&L for 80mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road / floor etc for cable protection, complete all as specified and directed.
Disconnecting the transformer outdoor type from HT/LT system and opening carefully by draining out transformer oil for rectifyig the leakage by replacing the unserviceable spare parts of capacity 200KVA transformer installed at Rhenock Sub stn, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecing the HT/LT system after the leakages have been rectified and tested on available electric load complete all as specified and directed.
Suppply only HT terminal bushing for stud of existing specification for 200 KVA Transformer all as specified and directed.
Supply only HT brass studs for 200 KVA Transformer all as specified and directed.
Supply only gasket of 6mm thick for top cover, HT/LT boxes for 200 KVA Transformer all as specified and directed.
Suppply only LT terminal bushing for stud of existing specification for 200 KVA Transformer all as specified and directed.
Supply only LT brass studs for 200 KVA Transformer all as specified and directed.
Trimming of tree branches which touches the LT/HT OH lines and 2.5 Mtr away from centre line of LT/HT oh lines span not exceeding 60 Mtr distance between poles by using neccessory T&P items and depositing the tree branches/leaves at 30 Mtrs away from the site. Note -Any number of tree branches cut in one span will be measured as one lenght of payment complete all as specified and directed.
Disconnecting the transformer outdoor type from HT/LT system and opening carefully by draining out transformer oil for rectifyig the leakage by replacing the unserviceable spare parts of capacity 50-100KVA transformer installed at Pedong, Algarah, Dalapchand Sub stn, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecing the HT/LT system after the leakages have been rectified and tested on available electric load complete all as specified and directed.
Suppply only HT terminal bushing for stud of existing specification for 50-100 KVA step downTransformer all as specified and directed.
Supply only HT brass studs for 50-100 KVA step downTransformer all as specified and directed.
Supply only gasket of 6mm thick for top cover, HT/LT boxes for 50-100 KVA step downTransformer all as specified and directed.
Suppply only LT terminal bushing for stud of existing specification for 50-100 KVA step downTransformer all as specified and directed.
Supply only LT brass studs for 50-100 KVA step downTransformer all as specified and directed.
M&L for General servicing, calibration & testing of 11 KV indoor Vacuum circuit breaker (cleaning, Oiling, greasing, IR Value check electrical and mechanical operation check and adjustment, primary injection of CTs to check the TMS relay and time coordination including checking auxiliary supply and control voltage, physical checking of breakers , epoxy housing carryout physical verification of any wear and tear breaker and rectified it, checking fixed and moving contracts spring charging motor control circuit & tighten the connections and close or trip coil clean the breaker compartment through lubricate the breaker, apply grease/ petroleum jelly and required part complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Note 3:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
MS BRAHMA CONSTRUCTION
RAMESH GURUNG
HEM RAJ GURUNG
G K SUTHAR
MS MAYA PRAKASH GOEL AND SONS
SANJAY SAW MILL
S K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .