Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.9 L+₹2.2 L (7.53%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹29.3 L
EMD Value
₹58,600
Closing Date
27 Dec 2019, 3:00 pmClosed
Major PK Morolia
GE (AFA) Hyderabad, Pin- 500043
PROVISION OF SMOKE FIRE DETECTION ALARM AT 6 TETRA SCHOOL CERTAIN E M REVENUE MAJOR MINOR WORKS AT AFA HYDERABAD
2019_MES_304511_1
8939/34/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AFA) Hyderabad
As per Tender Documents
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹58,600
Yes
22 Apr 2020
7 Dec 2019
28 Dec 2019
7 Dec 2019
27 Dec 2019
13 Dec 2019
7 Dec 2019 - 10 Dec 2019
Amount
NOTE FOR BOQ :- Bidders may please be note that certain items of this BOQ are same, hence you are requested to quote the same rates for those items which are same description otherwise lowest quoted rate for those items will be considered for payment purpose and no further claim shall be entertained in this regard.
PROVISION OF SMOKE AND FIRE DETECTION ALARM SYSTEM AT 6 TETTRA SCHOOL :- Supply, Installation, testing & commissioning of Analogue addressable Main fire alarm control panel-49 point with 24 V DC Battery backup complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply, Installation, testing & commissioning of Analogue addressable multi sensor smoke cum heat detectors with base including address & logic programming complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply, Installation, testing & commissioning of Analogue addressable smoke detectors with base including address & logic programming complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply, Installation, testing & commissioning of Aspiration smoke detector with air sampling pipes, addressable monitor module, remote indicator cum control unit & power supply including address & logic programming complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply, Installation, testing & commissioning of addressable manual call point including address & logic programming complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply, Installation, testing & commissioning of addressable control module + Relay including address & cause & effect and logic complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply & Fixing of Isolator Module complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply & Fixing of sounder wall mount complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply, Installation, testing & commissioning of Remote Indicator complete all as specified and as directed. Make:- MUCONS or equivalent approved make.
Supply & fixing unarmoured shield cable (single run) in FRLS PVC pipe of 2 core x 1.5 Sqmm complete all as specified and as directed.
Provision of qty-10, 32 Amps sockets along with wiring at IT server room of Signal Section (Ramdas Block AFNET) :- Supply and fix socket of 32 Amps, 2 pole and earth terminal indoor type wall socket, with DIN rail, IP 44 including all fixing accessories etc and with one MCB SPN 32 Amp, 240V, 50 Hz, AC and including 01 No 32 Amps, 2P + E Plug Sockets enclosed in thermo plastic enclosure complete all as specified and as directed.
S&F MCB SP 32 A 10 KA rupturing capacity complete all as specified and as directed.
S & F dummy PVC cover for existing MCB DBs complete all as specified and as directed.
M&L for Sub Main wiring with 4 runs of FRLS grade 1100 volt unsheathed PVC insulated cable of single core 16 sq mm (nominal area) multi-stranded copper conductor drawn through and including PVC conduite and conduite accesseries of suitable size (ISI marked) including all specials like joint elbow, Tee, junction , bend etc and provision of two runs of FRLS grade 1100 V rated PVC insulated multistranded copper conductor single core 16 sq mm for earth continuity complete all as specified and as directed.
Note (I): Necessary M.S junction boxes for inspection as required on site/directed by Engr-in-charge, shall deemed to be included in the quoted rate.
(II) Six runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(III) The wiring shall be done strictly by proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L for Sub Main wiring with 2 runs of FRLS grade 1100 volt unsheathed PVC insulated cable of single core 6 sq mm (nominal area) multi-stranded copper conductor drawn through and including PVC Conduite and Conduite accesseries of suitable size (ISI marked) incl all specials like joint elbow, Tee, junction , bend etc and provision of one run of FRLS grade 1100 V rated PVC insulated multistranded copper conductor single core 6 sq mm for earth continuity complete all as specified and as directed.
Note (I): Necessary M.S junction boxes for inspection as required on site/directed by Engr-in-charge, shall deemed to be included in the quoted rate.
(II) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(III) The wiring shall be done strictly by proper colour coding AS per IS standerds
S & F MCB DB 4 way triple pole vertical type 415 volts 50 Hz AC supply suitable for 4 pole MCCB incomer, fixed to the existing wall (concealed / surface) and making good the disturbed portion with the exsting specifications complete all as specified and as directed.
S & F MCCB 4 pole 63 Amps, 16 KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
Provision of flood lights at helicopter park near FCM :- Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core including cable connecting lugs, glands, jointing materials etc, laid in trenches, floors, roof ducts and fixing using clamps, saddle for pole wall, complete all as specified and as directed.
Supply and fix LED Flood light 150 W, IP 65 incliding driver & connections complete all as specified and as directed. (Make :- Bajaj Cat No BJFL150WLED/ CG Cat No LFLN-150-CDL/60/Wipro Cat No LF20-192-060-57G2 or other equivalent approved makes.
Supply and fix 2 runs of 1.5 Sqmm PVC insulated stranded copper ccomductor cable for connection of LED light with proper clamping, saddling / drawing through GI pipe etc complete all as specified and as directed.
Supply and fix cable junction box 167 X125 X 82 mm in size made out of thermoplastic sheet having IP 65 protection for out door installation fixed with 4 way bakelite cable terminals with one MCB SP 6 Ams to be fixed inside the box including 03 Nos polynide gland with checknut (M-25 - 3 Nos) fixed under the PCC block with good fininishing and match with existing surface etc.,complete all as specified and as directed. Make: - Hensel Cat No. K 9100 or equivalent models in Spelsberg / Rittal.
M&L for Excavating in post holes (or similar holes) each not exc 0.5 cu mtr, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed .
M & L for cement concrete as in posts , columns, foundations etc PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with and including plastering 10 mm thick in cement morter 1:6 complete all as specified and as directed .
Supply and lay pipe galvanized, “Light grade” including fittings 40 mm dia. for installation of flood lights complete all as specified and as directed .
Excavation in trenches not exc 1.50 mtr wide and not exc 1.5 mtr depth and getting out in soft / loose soil complete all as specified and as directed .
Returing, filling in and including spreading leveling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and as directed .
Removing excavated materials not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed .
M&L for cutting of road / hard standing upto 0.3 mtr in depth and 0.45 mtr wide for laying of cable protection pipe including refilling, watering, well ramming and finishing with PCC 1:2:4 and matching with surroundings, removing the broken P.C.C / road cutting materials and clearing the site complete all as specified and as directed .
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including consolidation punned thickness up to 18 cm complete all as specified and as directed . Note :- Punned thickness only will be considered for payment.
Supply and laying bricks common burnt clay building bricks, sub-class ‘B’ designation laid in trenches across the trench over the cable as cable protection complete all as specified and as directed .
Provision of dedicated cable with allied works for AFWWA complex :- Supply, laying and testing of cable XLPE insulated LT 1100 volts of grade armoured heavy duty electric cable with aluminium conductor of cross sectional area 35 sq mm 3.5 core including connecting to panel boards with the suitable size of aluminium lugs complete all as specified and as directed .
Supply, laying and testing of cable XLPE insulated LT 1100 volts of grade armoured heavy duty electric cable with aluminium conductor of cross sectional area 10 sq mm 2 core including connecting to panel boards with the suitable size of aluminium lugs complete all as specified and as directed ..
Supply and fixing cable route indicator, consisting of 200 mm x 200 mm x 6 mm thick cast iron plateincluding painted with "BLUE" colour over one sharp priming coat with inscription casting as LT cable and fixed with and including hot dipped GI angle iron of size 40 mm x 40 mm x 6 mm, 0.60 mtr long , GI bolts, nuts embedded in ground in route of cable with and including PCC foundation 1:3:6 type C-2 of size 200 mm x 200 mm x 300 mm complete all as specified and as directed .
Supply, Installation, Testing & commissioning of Outdoor type, double layer (in front side) door Meter cabinet of size 1.6x1.5x0.3mtr and made out of 3.15mm thick CRCA MS sheet with inner front door having glass window for viewing KWH meter and other doors shall be opeque. All door sholud have neoprene rubber gasket and locking arrangements. The cabinet shall be painted both internally and externally with powder coated paint (Shade : RAL 7032 SIEMENS GREY). The cabinet shall be dust and vermin proof with degree of protection IP 65. The cabinet shall be comprising with the following accessories :-
(a) Four pole incoming MCCB, 63Amps with breaking capacity 16KA having adustable thermal (80% to 100%) and fixed magnetic release. - 01No. (b) Aluminium bus bars for 3-phase & nuetral of current carying capacity up to 100Amps duly mounted on FRP/DMC insulators and necessary drilling for connections and duly covered with heat shrinkable PVC sleeves of standard colour code. (c) Provision of space for fixing of single phase KWH meters (10Nos) (d) MCB SPN 20Amps, C- Series, 10KA - 10Nos. (e) Digital type Voltmeter and Ammeter with suitbale CT = 01 No each
(f) Two way bakelite connector with nut, bolts and wahsers suitable for connecting the outgoing wires in the cabinet - 10Nos. (g) Internal wiring of meters / MCB / Cable connector shall be carried out with 10Sqmm copper conductor unsheathed, multistranded, PVC insulated, 1100volts grade, single core cable of standard colour code for phase & neutral including necessary lugs /nuts /bolts / washers etc. (h) LED phase indicating lamps (RYB) with control MCB (SP-2Amps) - 3Nos.
M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in groung (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 25x4mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I
Note:- (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item
(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point
Excavation in trenches not exc 1.50 mtr wide and not exc 1.5 mtr depth and getting out in soft / loose soil complete all as specified and as directed .
Returing, filling in and including spreading leveling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and as directed .
Removing excavated materials to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed .
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including consolidation punned thickness up to 18 cm complete all as specified and as directed. Note :- Punned thickness only will be considered for payment.
Supplu and Lay GI pipe light grade 40 mm dia for cable protection complete all as specified and as directed .
M&L for bricks sub class 'B' locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and as directed .
Provision of feeder piller and under ground cables for area lighting of vampire triangle :- Design, supply, erection, testing and commissioning of out door type LT Pump Control Panel board of overall size1200 mm (height) x 1200 mm (width) x 300 mm (Depth), platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos copper bus bars of rating 100 amps, Spreader link to incoming MCCB for termination of incoming cable and 3 way ebonite cable connector (rating 32 amps) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved Shade of RAL 7032.(SIEMENS GRAY) comprising of following complete, all as specified and as directed.
The panel board shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel board shall be made out of 3.15mm thick CRCA mild steel sheet and 3.15mm thick gland plate and having front opening facility with locking facility . The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation
a) Fully Automatic Star-Delta Starter, suitable for a 12.5 H.P. motor - 01 Nos (Make : L&T/BCH/TC) b) Fully Automatic Star-Delta Starter, suitable for a 10.0 H.P. motor - 02 Nos (Make : L&T/BCH/TC) c) DOL Starter suitable for a 3.0 HP motor 01 no (Make : L & T/ Legrand/Schneider)
d) Incomer MCCB 4 Pole, 63 Amps,16 KA with rotary handle - 01 No. (Make: L&T/Legrand/Schneider) e) Protective MCB for Pump Starters :- (i) 32 Amps, TP, 10 KA -01 Nos (Make : L & T/ Legrand/Schneider) (ii) 20 Amps, TP, 10 KA -02 Nos (Make :L & T/ Legrand/Schneider) (iii)10 A TPN MCB 10 KA - 01 No (Make : L & T/ Legrand/Schneider)
k) LED indicator lamp (Red-Yellow-Blue) - 01 Set Green 3 nos (Make: L&T/BCH/VAISHNO) l)Bakellite cable connector 4 way - 01 No (Make: ACDC/RAMANUJ) k) Bakellite cable connector 3 way- 6 Nos (Make: ACDC/RAMANUJ) m) Insulated Aluminium bus bar 25mmx4mm of suitable length duly mounted on insulators - 04 Nos n) 3A SP control MCB -3 nos (Make: L&T/Legrand/Schneider)
NOTE :- 1) M.S. channel (75 MC) base frame to be provided with the feeder pillar for mounting on the plat form. 2) All the cable entry/exit shall be from the bottom side only.
Supply, laying and testing of cable XLPE insulated LT 1100 volts of grade armoured heavy duty electric cable with aluminium conductor of cross sectional area 50 sq mm 3.5core including connecting to panel boards with the suitable size of aluminium lugs complete all as specified and as directed.
Excavation in trenches in any kind of soil not .exc 1.5 mtr wide and nut exc 1.5 mtr in depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
Returning, filling in trenches in any kind of soil in layers not exc 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and as directed.
Removing excavated materials not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including consolidation punned thickness up to 18 cm complete all as specified and as directed. Note :- Punned thickness only will be considered for payment.
M&L for laying bricks sub class 'B' locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth wire 4mm dia connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I
Note:- (i) Cost of GI earth wire and GI protection pipe up to 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation,returninng & filling, PCC chamber pit,RCC cover & test point (iii) PCC pit shall be provided at least 500 mm away from the earth pit and not just on the earth pit
Provision of certain safety equipments in the DG SETS at the Perimeter area :- Supply, fixing, testing & commissioning of following safety equipment of DG set 15 KVA complete all as per manufacturers instructions after fixing of the following items with control wiring and connected accessories complete all as specified and as directed. (a) Digital line voltage monitor 02 Nos make: proton (b) EP Timer 12 volts -02 Nos (c) PLA RELAY -02 Nos (Make :- Kirloskar or equivalent approved make)
Shifting of existing electric emergency alarm bell from Armoury entrance gate to Orderly Officer's Room :- Supply and laying LT UG cable, XLPE insulated armoured, heavy duty aluminium conductor multistranded, 1100 volts grade, of 10 Sqmm x 2core cross sectional area laid in trenches / fixing on walls / poles or passing through GI pipe including connecting up with suaitable lugs, nuts and bolts wherever required and testing complete all as specified and as directed.
Supply and fix cable gland double compression type, weather proof suitable for 4 Core 16 Sq mm armoured cable complete all as specified and as directed.
Supply and fixing cable route indicator, consisting of size 200 mm x 200 mm x 6 mm thick cast iron to be painted with “BLUE” colour over a coat of sharp primer with inscription casting as LT Cable and fixed with and including hot dipped GI angle of size 40 mm x 40 mm x 6 mm, 0.60 mtr long, GI bolts, nuts embedded in ground in route of cable with and including PCC 1:3:6 type C-2 of size 200 mm x 200 mm x 300 mm complete all as specified and as directed.
S&F of 22 cms (9 inch) dia Gang Bell, round shaped of operating rated voltage single phase 220 V to 250 V, to be fixed on wall including connections complete all as specified and as directed.
S & F weather proof cable junction box of size 98 mm x 98 mm x 61mm, made out of thermoplastic, having IP 65 protection for outdoor type and including cable glands of size M 16 x 1.5 and fixed with 4 way bakelite cable terminals fixed on poles/pipes with aluminium clamps of size 25 x 3, nuts, bolts, washers etc. complete all as specified and as directed Make : Hensel Cat No D 9045 or equivlent approved make.
S&F GI Pipe " light grade " 32 mm dia and laid in trenches on road crossing or fixed with pole for cable protection complete all as specified and as directed
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine with and including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed
Excavation in trenches not exc 1.50 mtr wide and not exc 1.5 mtr depth and getting out in soft / loose soil complete all as specified and as directed
Returing, filling in and including spreading leveling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and as directed
Removing excavated materials not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
M&L for cutting of road / hard standing upto 0.3 mtr in depth and 0.45 mtr in wide for laying of cable protection pipe including refilling, watering, well ramming and finishing with PCC 1:2:4 and matching with surroundings, removing the broken P.C.C / road cutting materials and clearing the site complete all as specified and as directed
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including consolidation punned thickness up to 18 cm complete all as specified and as directed Note :- Punned thickness only will be considered for payment.
Supplying and laying bricks common burnt clay building bricks, sub-class ‘B’ designation laid in trenches across the trench over the cable as cable protection complete all as specified and as directed
Provision Work SERVICES FOR INSULATING ALL EARTHING STRIPS AT MUZUMDAR BLOCK :- Supply and Fix DMC / FRP insulators, of suitable size to seperate the earth strips from the walls, duly screwed on the walls and making holes in the earth strips by drilling and fixing the earth strip rigidly with the insulators with GI bolts, nuts, washers etc complete all as specifed and as directed.
Provision of deficient Voltage Stabilizers at Flying Faculty :- Supply & installation, connection, testing and commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 130 volt to 300 volt with output voltage stabilized at 230 V with accuracy of ± 2.5%, Load capacity 12 Amp suitable for 1.5 Ton Air Conditioner including cable connection in PVC casing caping from socket to stabilizer, complete all as specifed and as directed. Make :- V GUARD/ VOLINA/ WHIRLPOOL/ CONSUL
M&L for submain wiring with 2 runs of 4.0 sq mm and 1.0 run of 4.0 sq mm Earth Wire single core PVC insulated FRLS sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC casing caping / conduit pipe as per site requirement including all accessories complete all as specified and as directed. Note:- 3 runs of copper wire and 1 run casing caping / conduit pipe shall be measured as one unit length.
Provision of Security Lights for MAFI CCR Building :- Excavation in trenches in soft / loose soil not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
Excavation in trenches in soft / loose soil not exc 1.5 mtr wide exc 1.5 mtr depth but not exc 3.0 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including consolidation punned thickness up to 18 cm complete all as specified and as directed. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any kind of soil in layers not exc. 25 cm after laying the cables including spreading, levelling, and well ramming complete all as specified and as directed.
M&L for bricks sub class 'B' locally available best quality laid in trenches above sand cushioning for cable protection complete all as specefied and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed
M&L for 40 mm dia light grade galvanized pipe ISI marked with all fitting laid in trenches, under road or fixing on wall / pole / crossing nallah etc complete all as specified and as directed .
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 10 sqmm 2 core complete all as specified and as directed.
Supply and fix Steel tubular swaged poles with M.S base plate, finial tapper plug, bolts, nuts, and screw as specified type 410 SP- 31 (9 mtrs long ) complete all as specified and as directed. (Note:- Excavation, earthwork, PCC foundation, coping etc will be measured and paid separately)
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, coping to pole for embedding stay road all as specified, including necessary form work and applying two coats of white wash to exposed surfaces of coping / platform complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-2 mix using 40 mm graded stone aggregate for foundation / platform / pedestal / stay wire etc, complete all as specified and as directed.
S&F LED Street light fitting 1 x 25 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution including GI pipe light grade bracket 40 mm dia, 1.2m long bent to shape as required and fixed with suitable size of MS clamps, (40 mm x 5 mm MS Flat) nut, bolt, washers etc to poles / walls complete, connnection with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make:- Crompton Cat Part No:- LSTS-25-CDL/Havells Cat Part No:- ENDURACITYLITEPLATSL25WLED757SASYBOPC/Bajaj Cat Part No:-BCLST 25W LED-I
S & F cable Junction box of size 167 mm x 125 mm x 82 mm size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals and connector including 03 Nos polymide gland with check nut (M-32-01 Nos & M- 25 -02 Nos ) fixed on poles with aluminium clamps of size 25 x 3, unts, bolts, washers etc., complete all as specified and as directed Make :- Cat No . D-9105 of HENSEL or equivalent in SPELSBERG / RITTAL.
PROVN OF WALL MOUNTED SWITCH BOARD 15 AMPS QTY 02 POWER SOCKET OF LOGISTICS SECTION :- M&L for sub main wiring with 1100 volts grade 2 runs of 6 sq mm. (nominal area) single core FR Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and rigid non-metallic PVC conduit of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and as directed.
Note : (I) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(II) The wiring shall be done strictly by proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L for Point wiring complete as specified with 1100 volts grade 2.5 sqmm. (nominal area) single core FR Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduite suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 15 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring above but green in colour as continuous earthing wire complete all as specified and as directed.
Note :- The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
Supply and Fix Switch socket combination 3 pin, 6A/16, 5 in 1 flush type universal type including Gang Box complete all as specified and as directed.
S&F MCB DB SPN 6 way with copper bus bar & neutral link double door type to be fixed in the wall including connections complete all as specified and as directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
Requirement of electric wiring for power point socketsin room no 224 , 2nd floor, GT Faculty at PC LAL Block :- M&L for sub main wiring with 1100 volts grade 2 runs of 6 sq mm. (nominal area) single core FR Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and rigid non-metallic PVC conduit suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and as directed.
Note : (I) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(II) The wiring shall be done strictly by proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L for Point wiring complete as specified with 1100 volts grade 2.5 sqmm. (nominal area) single core FR Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduite suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 15 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring above but green in colour as continuous earthing wire complete all as specified and as directed.
Note :- The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
Supply and Fix Switch socket combination 3 pin, 6A/16, 5 in 1 flush type universal type including Gang Box complete all as specified and as directed.
S&F MCB DB SPN 6 way with copper bus bar & neutral link double door type to be fixed in the wall including connections complete all as specified and as directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
Provn of Additional Lights in FCM :- M&L for Point wiring with 1.5 sq mm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC cassing & capping and accessories ISI marked fixed surface on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified and as directed. (a) One fan/ light point controlled by one Piano Switch
Supply and fixing switch piano flush button single pole one way 5 Amp complete all as specified and as directed.
S & F Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts ISI marked complete all as specified and as directed.
S&F surface mounted type LED tube light fitting 1 x 20 watts LED industrial batten type including LED tubes complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. (Make :- CG Cat No LCTL-18 CDL/ Bajaj Cat No BCLSB 18NW/Wipro Cat No LL20-221XXX 65NE3 or other equivalent approved makes
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete. Distribution Board shall be fitted out side of the explosive store complete all as specified and as directed.
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amp 10 KA complete all as specified and as directed.
S&F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply, complete all as specified and as directed.
M&L for Sub Main wiring with 2 runs of FRLS grade 1100 volts grade unsheathed PVC insulated cable of single core 4 sq mm (nominal area) multi-stranded copper conductor drawn through and including PVC Cassing and capping of suitable size (ISI marked) incl all specials like joint elbow, Tee, junction , bend etc and provision of one run of FRLS grade 1100 V rated PVC insulated multistranded copper conductor single core 4 sq mm for earth continuity all as directed.
Note:- (I) Necessary M.S junction boxes for inspection as required on site/directed by Engr-in-charge, shall deemed to be included in the quoted rate.
(II) Three runs of wire and one run of casing / capping will be measured as one unit length.
(III) The wiring shall be done strictly by proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
Provision of wiring for power supply, three wall mounted fans and 04 lights, 04 ceiling fans and 04 15 Amps sockets at Band section :- M&L for Point wiring complete with 1.5 sq mm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC cassing & capping and accessories ISI marked fixed surface on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified
(a) One fan point / light point controlled by one piano switch
Supply and fixing switch piano flush button single pole one way 5 Amp complete all as specified.
M&L for Point wiring complete with 2.5 sq mm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC cassing & capping and accessories ISI marked fixed surface on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc complete all as specified and as directed. (a) One switch socket combination controlled by one switch.
Supply and Fix Switch socket combination 3 pin, 6A/16A, 5 in 1 flush type universal type including Gang Box complete all as specified and as directed.
M & L for Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts ISI marked complete all as specified and as directed.
Supply and fix wall mounting fan 400 mm sweep with inbuilt speed regulator complete all as specified and as directed.
S&F surface mounted type LED tube light fitting 1 x 20 watts LED industrial batten type including LED tubes complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make: CG Cat No LCTL -18 CDL /Bajaj Cat No BCLSB 18NW/Wipro Cat No LL20-221XXX 65NE3 or other equivalent approved makes
Supply & fix ceiling fan with complete accessories 230 V, 1200 mm sweep BEE 5 star rated and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed. Make : Crompton Model No. HS Decora Plus - 5 Star or equivalent approved make in Usha / Orient / Havells / Philips
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete. Distribution Board shall be fitted out side of the explosive store complete all as specified and as directed.
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amp 10 KA complete all as specified and as directed.
S&F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply, complete all as specified and as directed.
M&L for Sub Main wiring with 2 runs of FRLS grade 1100 volts grade unsheathed PVC insulated cable of single core 2.5 sq mm (nominal area) multi-stranded copper conductor drawn through and including PVC Cassing and capping of suitable size (ISI marked) incl all specials like joint elbow, Tee, junction , bend etc and provision of one runs of FRLS grade 1100 V rated PVC insulated multistranded copper conductor single core 2.5 sq mm for earth continuity complete all as specified and as directed.
Note (I): Necessary M.S junction boxes for inspection as required on site/directed by Engr-in-charge, shall deemed to be included in the quoted rate.
(II) Three runs of wire and one run of casing / capping will be measured as one unit length.
(III) The wiring shall be done strictly as per IS standards.
S & F stepped type electronic fan regulator flush type complete all as specified and as directed.
Provisioning of earth pit display boards and lightning arrester at AFLB & AB section :- Supply and fix Copper strip 25 x 3 mm with saddles and fixing screws etc. for roof conductors / down conductors / connecting to earth pit to equipement including porcelain insulators all the joints complete all as specified and as directed.
Supply and Fixing Air Termination, Single pointed, aluminium rod 12 mm dia and 300 mm long complete all as specified and as directed.
M&L for grid point made out of 4m thick copper bus bar 250 mm length duly fixed on porcelain insulators housed in suitable size powder coated MS box and connecting up existing earthing.
S&F Earthing grid indicator made out of 3 mm thick MS sheet of size 300 mm x 200 mm duly welded with 500 mm long 25 x 25 x 6 mm angle iron duly fixed near to the grid point with cement grout including writing earthing details such as earth resistance, connected to etc complete all as specified and as directed.
Supply and Fixing Test Point Terminal Block made out of gun metal or Phosphorus bronze size 75 mm x 75 mm x 25 mm, drilled and screwed and including 3 Nos 8 mm dia 25 mm long hex complete all as specified and as directed.
M&L for tubes, 'light grade', galvanised, 40 mm dia with all fitting laid in trenches / pole for protection of earth strip complete all as specified and as directed.
M&L for PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways comnplete all as specifd and as directed.
M&L for tubes, 'light grade', galvanised, 25 mm dia with all fitting laid in trenches / pole for protection of earth strip complete all as specified and as directed.
Provn of Tube Lights in room No 214,216 and 220 located on second floor of the bldg at GT Faculty :- M&L for Point wiring complete with 1.5 sq mm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC cassing & capping and accessories ISI marked fixed surface on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified and as directed. (a) One light point controlled by one switch
Supply and fixing switch piano flush button single pole one way 5 Amp complete all as specified and as directed.
S&F Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts ISI marked complete all as specified and as directed.
S&F surface mounted type LED tube light fitting 1 x 20 watts LED industrial batten type including LED tubes complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. (Make :- CG Cat No LCTL -18 CDL/ Bajaj Cat No BCLSB 18NW/Wipro Cat No LL20-221XXX 65NE3 or other equivalent approved makes
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and as directed.
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amp 10 KA complete all as specified and as directed.
S&F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply, complete all as specified and as directed.
M&L for Sub Main wiring with 2 runs of FRLS grade 1100 volts grade unsheathed PVC insulated cable of single core 4 sq mm (nominal area) multi-stranded copper conductor drawn through and including PVC Cassing and capping of suitable size (ISI marked) incl all specials like joint elbow, Tee, junction , bend etc and provision of one run of FRLS grade 1100 V rated PVC insulated multistranded copper conductor single core 4 sq mm for earth continuity complete all as specified and as directed.
Note (I): Necessary M.S junction boxes for inspection as required on site/directed by Engr-in-charge, shall deemed to be included in the quoted rate.
(II) Three runs of wire and one run of casing /capping will be measured as one unit length.
(III) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
Installation of 15 Amps qty -4 and 5 amps sockets qty -3 in room no 36 of Faculty of Flying section :- M&L for sub main wiring with 1100 volts grade 2 runs of 6 sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and rigid non-metallic PVC conduit suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and as directed.
Note : (I) Three runs of wire and one run of conduit will be measured as one unit length.
(II) The wiring shall be done strictly by proper colour coding as per IS standards
M&L for Point wiring complete as specified with 1100 volts grade 1.5 sq mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduit suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 5 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring above but green in colour as continuous earthing wire complete all as specified and as directed. Note :- The wiring shall be done strictly by proper colour coding as per IS
M&L for Point wiring with 1100 volts grade 2.5 sq mm. (nominal area) single core FR Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduit suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 15 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring above but green in colour as continuous earthing wire complete all as specified and as directed. Note :- The wiring shall be done strictly by proper colour coding as per IS
Supply and Fix Switch socket combination 3 pin, 6 Amps /16 Amps , 5 in 1 flush type universal type including Gang Box complete all as specified and as directed.
Supply and Fix Switch socket combination 3 pin, 6A, 5 in 1 flush type universal type including Gang Box complete all as specified and as directed.
S&F MCB DB SPN 6 way with copper bus bar & neutral link double door type to be fixed in the wall including connections complete all as specified and as directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
SRI SAI CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .