Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.2 L+₹4,081.20 (0.40%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹10.9 L+₹75,177.15 (7.43%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹13.4 L+₹3.3 L (32.3%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹10.5 L
EMD Value
₹21,000
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
GE (AF) BHISIANA PIN-151201
AS per BOQ/Price Schedule
2023_MES_606177_1
GE/BHI/MW/2023-24
Open Tender
Civil Works
Item Rate
183 days
GE (AF) BHISIANA
As per NIT/Tender documents
6 documents required · 6 mandatory
₹500
GE (AF) BHISIANA
₹21,000
9 Oct 2023
27 Jun 2023
26 Jul 2023
27 Jun 2023
24 Jul 2023
11 Jul 2023
27 Jun 2023 - 3 Jul 2023
Amount
(B/R WORKS)
Surface dressing not exceeding 15 cm deep in soft/loose soil complete all as specified and directed by Engineer-in-Charge .
Excavating Over Areas not exc. 1.50 Metre deep and getting out in Soft/Loose Soil, complete all as specified and directed by Engineer-in-Charge .
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engineer-in-Charge.
M & L for hardcore of broken bricks of gauge n exc. 63 mm , deposited , spread and levelled and compacted in layers n exc. 15 cm thick , watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajja etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns,footing, plinth beam, roof beam, lintels, slabs and other similar structures etc., hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
All as per ser item no 14 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in CM 1 : 4 on brick or concrete surfaces (in ceiling) etc finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1 : 6 on other than fair faces of brick work or concrete surfaces etc finished even and fair without using extra complete all as specified and directed by Engineer-in-Charge.
M&L rendering 15mm thick on cement mortar 1:4 finished fair faces of brick/concrete surfaces even and fair without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for applying three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete complete all as specified and directed by Engineer-in-Charge.
M & L for applying distemper oil emulsion over one coat of primer on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls all as specified & directed by Engineer-in-Charge
M & L for 75 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) as in plinth protection complete all as specified and directed by Engineer-in-Charge.
M&L for 20-25 mm thick kota stone floor tiles machine cut (square/recatangular) etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed n CM (1:6) as in screed bed or bedding and demolition of existing floor finishes complete as all specified and directed by Engr-in-Charge.
M&l for kota stone floor tiles 20-25 mm thick, machine cut (square/recatangular) as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 10 mm thick cement plaster in CM (1:4)for receiving tile to wall complete as all specified and directed by Engr-in-Charge.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs,hinges, lock strike plate, etc complete all as specified and directed of size 105 X 60mm, complete as all specified and directed by Engr-in-Charge.
M&L for PCC (1:3:6) type C-1 using 20 mm graded agg as in back of pressed steel chowkhats etc complete as all specified and directed by Engr-in-Charge.
M & L for 35mm thick of 2nd class hard wood plain framed factory made panelled shutters (any number of pannel) with panel of timber flat on both side (feathered edged) or of 12mm thick veneered particle boards with commercial faces vineers. Complete incl fixed to chowkhat the size of rails and styles as per IS 1003 or as described in SSR Part-I kiln seasoned and chemically preassure treated complete all as specified and directed by Engineer-in-Charge.
S&F 200mm Aluminium anodised barrel tower bolts of extruded section and fixed complete as all specified and directed by Engr-in-Charge.
S & F extruded Aluminium handles, cast type, anodised of size 150mm complete all as specified and directed by Engineer-in-Charge.
S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete as all specified and directed by Engr-in-Charge.
S&F Powder coated Anodised aluminium frame for doors, windows, ventilators, partations with one or more rebates including joining cleat for fixing etc. complete as all specified and directed by Engr-in-Charge.
S&F Powder coated Anodised aluminium window and ventilator shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete as all specified and directed by Engr-in-Charge.
S&F Powder coated aluminium decorative grill of size of mesh 50mmX50mm fixed with doors, window for safety of glass etc. complete as all specified and directed by Engr-in-Charge.
S & F sheet glass 5.5 mm thick ordinary quality and glazing with oil putty/ any type of beading in square/rectangular exceeding 1.00 Sqm in each pane complete as all specified and directed by Engr-in-Charge.
Supply and fixing Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tack or galvanised wire staple complete as all specified and directed by Engr-in-Charge.
M&L for 10mm thick Screed bed or bedding layer in cement mortar 1:4, laid on roof, mixed with water proofing compound when concrete is green, as per manufacturere instructions complete as all specified and directed by Engr-in-Charge. (Note - Water proofing compound shall be measured and paid separately).
Supplying only liquid water proofing compound, ISI marked complete all as specified and as directed.
M&L for APP based polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with forced application over roof surface with a coat of hot blown bitumen conforming to IS-3384-1965 of grade 85/25 @ 1.2 kg/Sqm at bottom of the membrane as bonding material, complete all as per manufacturer's instructions all as specified and directed by Engineer-in-Charge.
S&F Curtain rails, mild steel, chromium plated, including fixing of brackets and both ends decorative nobs, complete all as speccified and directed as per approved sample by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft and loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid coloured ceramic tiles/Rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) for laying floor finishes complete all as specified and directed by Engineer in Charge.
M&L for Non skid coloured ceramic tiles/Rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:3 to receive vertical tiles complete all as specified and directed by Engineer in Charge.
( E/M WORKS/ SERVICES)
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
All as per Item No 3 for One 3 Pin Switch socket Combination 6 amp on the independent board.
All as per Item No 3 for One 3 Pin swich socket Combination 6 amp on the same board with other switches.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed by Engineer
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 6 Pin, complete all as specified and as directed.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and complete all as specified and as directed.
S&F Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC Conduit medium grade 25mm dia including making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge. Note: (a) The quoted unit rate shall include cost of PVC Conduit (b) Two Runs of Copper cable along with One Runs for earthing and one Run of PVC Conduit shall be measured as one unit.
S&F MCB DB 4-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded/Concealed upto Wall surfaces including Connecting up with Existing Cable Incoming and Outgoing with Cable Lugs as per the Site requirement and and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to Match with the Existing Finishes, complete all as specified and as directed.
S&F MCB Single Pole & Neutral, 40 to 63 Amp, 240 /415 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
S&F MCB Single Pole 6 TO 32 Amp, 240 /415 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed by Engineer in Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR Part-I and testing on completion including necessary excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe, 15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc complete all as specified and as directed by Engineer in Charge.
S&F 1X18 watt wall mounted, new generation LED T-8 Retro fit for multipurpose application with LED Rod, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
( E/M AIR CONDITIONING WORKS)
S&F Sub-main Wiring (Surface/ Concealed) with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in medium grade PVC CONDUIT/PVC CASING & CAPING, complete all as specified and as directed by Engineer in Charge. Note: (a) 3 Runs of 4 sqmm Copper Wire & 1 Runs of PVC conduit shall be measured as single unit. (b) The disturbed surface of wall for surface box wiring shall be make good by applying cement plaster, putty and colour wash etc to match with the existing surfaces. (c)The quoted unit rate shall include Cuting chases for conduits and sinking's for boxes.
Supply and installation inverter based vertical pack type units indoor/outdoor complete with cordless remote control unit, twin rotary compressor, single phase units 240V, 50 Hz of capacity 3.5 TR/ Ton (copper Coil) electric driven , new 5 star rating including all accessories like brackets, rubber tubing, copper tubing as required at site, gas charging, with auto filter clean technology etc including testing and commission with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as specified and as directed by Engineer in Charge. Note : All cooling /condensing coil should be copper material.
Supply and install Voltage stablizer copper winding automatic digital type operation single phase naturally air cooled indoor type & designed for input variation between 135 Volts to 285 Volts with output voltage stablized at 230 Volt with accuracy of (+/-) 2.5 percent of capacity 7 KVA, complete all as specified and as directed by Engineer in Charge.
S&F Sheet Metal Enclosure, Triple Pole and Earth Plug Top and Socket with and including 1 No. MCB Triple Pole, 32 Amp, 415 Volt and Connecting, complete all as specified and as directed by Engineer in Charge.
Supply and fix PVC rigid conduit pipe ISI Mark 25mm dia including all accessories and necessary saddles with fixing screws, gutties etc. for drain out water complete all as specified and as directed by Engineer in Charge. Note: The quoted unit rate shall include Cuting chases for conduits and sinking's for boxes and making good to walls, floors etc.
Supply and fix stand vertical pack type units with mounted on rotating wheel suitable for Indooe/ Outdoor unit of capacity 3.5 TR/Ton including necessary fixing arrangement such as angle Iron , rubber/ Iron wheel having rotation of 360 degree , nut, bolts etc complete all as specified and directed by Engr-in-Charge
S&F Sheeet metal enclosures for TPN 4 Way DB's suitable to incorporated with 200 amps rates busbar, 220 volts, as per IS-8623 complete all as specified and dircted by Engineer in Charge.
S&F MCCB Four pole 32 amps 'C' series, breaking capacity 16 Ka 'C' curve 415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as directed by Engineer in Charge.
S&F MCB SP, 20 Amps to 32 Amps, C Series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as directed by Engineer in Charge.
M&L for Earthing complete with galvanised steel plate electrode, 600 x 600 x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level ) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in para No 4 to the earthing test point all as specified and as directed. Note :- The Cost of Excavation and Earth work PCC pit and Cl cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed including in the unit rate for earthing as as specified and as directed by Engr-in-Charge
Supply & Fixing/Laying XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross sectional area 25 Sqmm 3½ Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified as and directed. Note: Earth work shall be measured and paid seperately under appropriate item.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for Foundation etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm thick in Soft/Loose Soil, complete all as specified and as directed.
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and directed by Engr-in-Charge
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and directed by Engr-in-Charge NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
M&L for Brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed by Engr-in-Charge
Note:- Contractor is required to submit 10% of the Contract Sum as retention money in FDR/ Bank Guarantee format before claiming first RAR payment and it will be released after Final Bill.
M/s Luxmi Constructions
Rasvinderpalandco
SWARN SINGH AND CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .