Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | ₹40.4 L Quoted ₹40.5 L | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹41.9 LRejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | ₹41.9 L | L2 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 3 | L3₹43.2 LRejected-Finance 17 BRAHAMPUTRA COMPLEX KALA AAM BULANDSHAHR BULANDSHAHR UTTAR PRADESH 203001 UDYAM UP 18 0025566 | BULANDSHAHR | UTTAR PRADESH | 203001 | ₹43.2 L | L3 | Rejected-Finance NOT BEING LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Unnati Engineers L1 | Industrial Traders L2 | HINDUSTAN TRADING COMPANY L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling of split air conditioning of capacity 1.5/2.0 TR complete with indoor/outdoor unit from any location of BKT Campus and deposited to MES yard and making good disturbed surfaces to match as existing complete all as specified and directed. | 30 | Each | 150 ₹4,500 | 200 ₹6,000 | 100 ₹3,000 |
| 2.00 | Dismantling of desert cooler ,Water cooler & refrigerator any type and capacity from any location of BKT Campus and deposited to MES yard complete all as specified and directed. | 33 | Each | 50 ₹1,650 | 50 ₹1,650 | 50 ₹1,650 |
| 3.00 | Supply, installation,commissioning and testing of Hi wall split type air conditioner of capacity1.5 TR (4500 K Cal/hr ) single phase suitable for 230 V + 10 %, 50Hz AC supply complete with cordless remote control unit using Non CFC refrigerant Gas,minimum 5 star rating inverter type and energy efficient complete comprising of following unit/components :-
(a) indoor unit with three speed blower fan with motor of appropriate capacity including PCB,thermostatic control,air filter and drain for condensing water
(b) Outdoor unit comprising compressor ,air cooled copper condensor with fan and motor unit shall be installed outside the building / on roof
(c) Refrigerant copper pipe for suction and discharge line with proper insulation ,condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safty accessories including control wiring for evaporator & condensing Unit with suitable size of copper cable complete all as specified and directed.
Note :- (i). Cutting holes in walls/window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .
(ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer is deemed to be included in the quoted unit rate. (iii) Powder coated MS bracket for fixing out door unit in wall or rooftop with necessary grouting and MS hold fast ,bolts etc is deemed to be included in the quoted unit rate. . | 19 | Each | 62,000 ₹11.8 L | 58,000 ₹11.0 L | 51,600 ₹9.8 L |
| 4.00 | Ditto all as per item No 3 but for 2 TR(6000 K cal/hr) with minimum 3 star rating complete all as specified & directed. | 11 | Each | 75,000 ₹8.3 L | 57,375 ₹6.3 L | 69,800 ₹7.7 L |
| 5.00 | Supply and installation and testing window type Air conditioner complete with cordless remote control unit using Non CFC refrigerant Gas ecofreindely with minimum 5 star rating inverter type and energy efficient of capacity 1.5 TR (4500 K cal/hr) consisting of compressor, evaporator coil,copper condensor coil, candensor fan with motor and , PCB for better air flow complete all as specified and directed.
Note :- .
(i) Electrical cable required for connection to voltage stabilizer with power supply point is deemed to be included in the quoted unit rate.
(ii) drain piping is is deemed to be included in the quoted unit rate. | 2 | Each | 40,000 ₹80,000 | 38,000 ₹76,000 | 43,000 ₹86,000 |
| 6.00 | Supply, installation and testing of window Desert Air Cooler (61 litre capacity of tank) electric driven single phase 230 volt, 50 Hz, 235 watt power consumption , plastic body (extruded polystyrene) of air flow capacity 4000 CFM with movable stand including high efficiency Aspen cooling pad ,powerful double blower, fully closeble louvers, cool flow dispenser complete all as specified and directed.
Make :- Symphony model JUMBO 65 DB or equivalent make (given in list of makes) as approved by GE in writing | 6 | Each | 14,000 ₹84,000 | 19,500 ₹1.2 L | 12,500 ₹75,000 |
| 7.00 | Supply, installation/fixing of electric driven single phase 230 volt 50 Hz desert cooler (evaporator type) 6000 CMH steel body factory made fabricated with 22 mm gauge thick galvanised steel body and water storage tank of 100-120 ltr with powder coated paint in white silver color complete inner and outer side and anticorrosive paint inner side of tank .Desert cooler should have complete with wood wool cooling media ,manual air defusing system on grill,3 speed control regulator ,on/ off switch ,3 mtr long 3 core copper cable,single phase 18 inch exhaust fan 1400 rpm single phase 230 volt AC with air flow minimum 20ft ,water pumping set of suitable wattege (HP)submersible type single phase complete all as specified and directed. | 15 | Each | 10,000 ₹1.5 L | 12,000 ₹1.8 L | 10,900 ₹1.6 L |
| 8.00 | Supply and installation and testing for refrigerator ,electric driven single phase 230 volt, 50 Hz, of capacity 210 litrs (or next nearest capacity) frost free,minimum 5 star rating complete all as specified and directed. . | 2 | Each | 25,000 ₹50,000 | 25,000 ₹50,000 | 28,000 ₹56,000 |
| 9.00 | Supply, installation and testing of glass top deep freezer single phase 230 volt ,50 htz capacity 320 ltr,with minimum 5 star rating complete all as specified and directed . | 1 | Each | 45,000 ₹45,000 | 31,000 ₹31,000 | 35,000 ₹35,000 |
| 10.00 | S&F electronic wall mounted digital display(Input & output) voltage stabilizer for automatic voltage correction single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility including instant start & time delay relay of 3 minute capacity 4KVA complete all as specified and directed. | 18 | Each | 5,000 ₹90,000 | 4,900 ₹88,200 | 5,850 ₹1.1 L |
Tender Value
₹43.2 L
EMD Value
₹86,500
Closing Date
15 Apr 2024, 6:00 pmClosed
GE (AF) BKT
GE (AF) BKT, LUCKNOW
SPECIAL REPAIR OF BER COOLING AND HEATING APPLIANCES AND SHIFTING OF DG SET FROM OLD CCR/ SIGNAL SECTION AT AF STN BKT
2024_MES_641733_2
8742/BKT/E8
Open Tender
Civil Works
180 days
GE (AF) BKT
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹86,500
Yes
24 Jun 2026
19 Mar 2024
17 Apr 2024
19 Mar 2024
15 Apr 2024
1 Apr 2024
Amount
Dismantling of split air conditioning of capacity 1.5/2.0 TR complete with indoor/outdoor unit from any location of BKT Campus and deposited to MES yard and making good disturbed surfaces to match as existing complete all as specified and directed.
Dismantling of desert cooler ,Water cooler & refrigerator any type and capacity from any location of BKT Campus and deposited to MES yard complete all as specified and directed.
Supply, installation,commissioning and testing of Hi wall split type air conditioner of capacity1.5 TR (4500 K Cal/hr ) single phase suitable for 230 V + 10 %, 50Hz AC supply complete with cordless remote control unit using Non CFC refrigerant Gas,minimum 5 star rating inverter type and energy efficient complete comprising of following unit/components :- (a) indoor unit with three speed blower fan with motor of appropriate capacity including PCB,thermostatic control,air filter and drain for condensing water (b) Outdoor unit comprising compressor ,air cooled copper condensor with fan and motor unit shall be installed outside the building / on roof (c) Refrigerant copper pipe for suction and discharge line with proper insulation ,condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safty accessories including control wiring for evaporator & condensing Unit with suitable size of copper cable complete all as specified and directed. Note :- (i). Cutting holes in walls/window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate . (ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer is deemed to be included in the quoted unit rate. (iii) Powder coated MS bracket for fixing out door unit in wall or rooftop with necessary grouting and MS hold fast ,bolts etc is deemed to be included in the quoted unit rate. .
Ditto all as per item No 3 but for 2 TR(6000 K cal/hr) with minimum 3 star rating complete all as specified & directed.
Supply and installation and testing window type Air conditioner complete with cordless remote control unit using Non CFC refrigerant Gas ecofreindely with minimum 5 star rating inverter type and energy efficient of capacity 1.5 TR (4500 K cal/hr) consisting of compressor, evaporator coil,copper condensor coil, candensor fan with motor and , PCB for better air flow complete all as specified and directed. Note :- . (i) Electrical cable required for connection to voltage stabilizer with power supply point is deemed to be included in the quoted unit rate. (ii) drain piping is is deemed to be included in the quoted unit rate.
Supply, installation and testing of window Desert Air Cooler (61 litre capacity of tank) electric driven single phase 230 volt, 50 Hz, 235 watt power consumption , plastic body (extruded polystyrene) of air flow capacity 4000 CFM with movable stand including high efficiency Aspen cooling pad ,powerful double blower, fully closeble louvers, cool flow dispenser complete all as specified and directed. Make :- Symphony model JUMBO 65 DB or equivalent make (given in list of makes) as approved by GE in writing
Supply, installation/fixing of electric driven single phase 230 volt 50 Hz desert cooler (evaporator type) 6000 CMH steel body factory made fabricated with 22 mm gauge thick galvanised steel body and water storage tank of 100-120 ltr with powder coated paint in white silver color complete inner and outer side and anticorrosive paint inner side of tank .Desert cooler should have complete with wood wool cooling media ,manual air defusing system on grill,3 speed control regulator ,on/ off switch ,3 mtr long 3 core copper cable,single phase 18 inch exhaust fan 1400 rpm single phase 230 volt AC with air flow minimum 20ft ,water pumping set of suitable wattege (HP)submersible type single phase complete all as specified and directed.
Supply and installation and testing for refrigerator ,electric driven single phase 230 volt, 50 Hz, of capacity 210 litrs (or next nearest capacity) frost free,minimum 5 star rating complete all as specified and directed. .
Supply, installation and testing of glass top deep freezer single phase 230 volt ,50 htz capacity 320 ltr,with minimum 5 star rating complete all as specified and directed .
S&F electronic wall mounted digital display(Input & output) voltage stabilizer for automatic voltage correction single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility including instant start & time delay relay of 3 minute capacity 4KVA complete all as specified and directed.
S&F ceiling fan BLDC type with remote & regulator control complete with blade ,down rod,remote,regulator and accessories 230 V,50 Htz,1200 mm sweep with five star rating energy efficient complete all as specified and directed.
S&F ceiling fan BLDC type with remote & regulator control complete with blade ,down rod,remote,regulator and accessories 230 V,50 Htz,1400 mm sweep with complete five star rating energy efficient complete all as specified and directed.
Supply & installation on wall electric operated single phase ,230 V AC,5 star rated water heater(gyser) storage type having capacity 25 ltr plastic moulded (ABS) thermoplast body with stainless steel glass line coating inner tank ,safty protection with thermal autocut off / restart function, multifunctional safty valve ,temperature sensing color charged LED adjustable ring knob ,mettalic flexible connection pipe with nuts for hot & cold water 15 mm dia of suitable length with, fixing accessories complete all as specified & directed.
S&F Submain wiring with two single core PVC insulated FRLSH multistrand copper conductor cable of size 4 Sq mm drawn into and including non metallic heavy duty rigid concealed PVC conduit not less than 25 mm size ISI marked with all fittings / accessories and 04 Sq mm FRLSH multistrand copper conductor cable as continuous earth wire and taking down old unserviceable submain wiring & making good to match the existing surface complete all as specified & directed.
S&F Submain wiring with two single core PVC insulated FRLSH multistrand copper conductor cable of size 6 Sq mm drawn into and including non metallic heavy duty rigid concealed PVC conduit not less than 25 mm size ISI marked with all fittings / accessories and 06 Sq mm FRLSH multistrand copper conductor cable as continuous earth wire and taking down old unserviceable submain wiring & making good to match the existing surface complete all as specified & directed.
S&F submain wiring with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 10 Sq mm drawn into and including non metallic heavy duty rigid concealed PVC conduit not less than 25 mm size ISI marked with all fittings / accessories and 10 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire and taking down old unserviceable submain wiring & making good to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure TPN 4 way double door distribution board,415 volt all as specified and directed
S&F sheet metal enclosure SPN 8 way double door distribution board ,415 volt all as specified and directed
S&F MCB TPN100 Amps,240 V,50 Htz,10KA breaking capacity "C" curved type complete all as specified and directed.
S&F MCB SPN 63 Amps 240 volt,50 hz,10 KA breaking capacity "C" curved type complete all as specified and directed.
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB single pole, 32 to 63 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S& F Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete all as specified and directed.
S & F socket outlet 5 pin 20 Amps modular type,2 module with suitable size of module metal flux boxes and including modular front cover plate and back plate for mounting modular type switch & socket with one single pole modular type MCB of capacity 20 amps (1 module) including electrical connection all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick burried directly in ground vertically at a depth not less than 3.0 metre deep below normal ground level with top edge of the plate not less than 2.25 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire GI wire 4.0 mmdia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1: 2: 4) type C2 using 40 mm graded stone aggregate including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr as specified and as shown on Plate No 3 of SSR Part all as specified and directed by Engr-in-Charge.
M& L for cutting / opening of window any type for fixing of window type AC including making frame of existing window type AC suitable for fixing of window AC complete packing of window after installation of AC complete all as per required at site and directed by Engr in charge.
Dismantling of cable connection and Shifting, Installation testing and commissioning of existing serviceable 125 KVA DG Set from foundation, shifting the DG Set to new location and connecting up with cables and Foundation with PCC (1:2:4) type B-2 using 40mm graded stone aggregate all as required and directed & specified.
Supply and Laying in trenches / fixed to wall/ drawn in pipe/duct/laid in floor XLPE insulated screened,PVC bedded and sheathed and steel wire/strip armoured cable 1100V grade with stranded aluminum conductor of cross sectional area 150 Sq mm 3.5 core complete all as specified and directed.
Supply and Laying in trenches / fixed to wall/ drawn in pipe/duct/laid in floor XLPE insulated screened,PVC bedded and sheathed and steel wire/strip armoured cable 1100V grade with stranded aluminum conductor of cross sectional area 50 Sq mm 3.5 core complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes/pole foundation etc. all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed.
Supply and laying sand cushioning for cable protection in trenches 8cm before laying cable and 15 cm deep over the cable complete all as specified and directed
Supply and laying well burnt sub class ‘B’ bricks, locally best available laid in trenches for protection of underground cable complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of upto 100mm bore GI tubing of any description below/under existing road surfaces / apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing streta after laying pipes complete all as specified and directed.
S&F light grade galvanized iron pipe 80 mm bore confirming to IS : 1239 with all fittings fixed on walls/poles/crossing of road etc for protection of cable complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 3.25 meter below ground level) connected to GI strip of size 32mmx6 mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board /panel etc. as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 using 20mm graded stone aggregate for earth pit with 40mm x 40mm x 6 mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 40mm thick cover reinforced with 8 mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, earth pit shall be costed on PCC (1:2:4) (100mm thick of size 800mmx500mm ) including GI light grade watering pipe 20 mm dia with funnel,wire mesh all as shown in electrical plate no. 3 of SSR Part I of 2009 and 40 mm dia GI light grade pipe for earth lead protection complete all as specified and directed.
Supply, fabrication, errection, installation, testing and commissioning of cubical, outdoor type CPRI approved LT feeder piller Box totally enclosed weather and vermin proof, factory made fully compartmentalised made out of 3.15 mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing portions. Protection of enclosure IP-54 complete with two coat enamel paint over one coat of red oxide primer including suitable angle flat iron frame work for supports, excavation earth work, PCC foundation ( mini 45 cm hight from GL) , making all incoming and out going connection with suitable size copper cable including cable lugs , cable gland etc with one MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 ploes, rating 200 Amps , with rupturing capacity 25 KA - 1 No complete all as specified and directed
S&F of MCCBs thermal magnetic including necessery fixing arrangement of capacity 200 Amps, 4 Pole, breaking capacity 25KA complete all as specified and directed.
S&F of MCCBs thermal magnetic including necessery fixing arrangement of capacity 250 Amps, 4 Pole, breaking capacity 25KA complete all as specified and directed,
Industrial Traders
HINDUSTAN TRADING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid