| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-Finance MAIN CHOWK TABAB TILLO JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | ₹2.3 L | L1 | Accepted-Finance Lowest |
| 2 | L2₹2.4 LAccepted-Finance 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | ₹2.4 L | L2 | Accepted-Finance higher than L1. |
| 3 | L3₹2.4 LAccepted-Finance | ₹2.4 L | L3 | Accepted-Finance higher than L1. |
| Sl No | Description | Qty | Unit | Rishabh Electricals and Mechanical Works L2 | GANPATI ELECTRICAL AND MECHANICAL WORKS L1 | GEETA ENGINEERING MECH WORKS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Repair to 250 KVA LT electric transformer installed at LIS Miari by way of disconnecting of HT and LT line connections from transformer. Removing the top cover after unscrewing all the nuts and bolts along with dismantling of HT & LT bushes. Draining out of transformer oil from transformer tank at site. Taking out the coil assembly using chain pulley and other allied tools and tackles. Dismantling of damaged HT coils-12 nos and LT Coils- 03 nos from the coil assembly at site. Carriage of damaged coils to road side using tools, tackles and manual labour through hilly terrain. Loading in mechanical transport for further shifting to workshop for repair. Dismantling of coils at workshop and rewinding of HT coils with the aluminium wire of requisite specifications as per original design and varnishing complete. Dehydrating/drying the coils. Reconditioning of LT coils by way of rewinding of the aluminium coils as per original design with insulation material and varnishing complete. Then carriage back of newly rewound coils along with other allied material to the site of installation in similar manner. Servicing, cleaning and flushing of transformer tank by using appropriate chemicals to clean all the deposits and repair to radiator of the transformer to plug the leakage at multiple spots, drying completely. Fitting of the newly rewound coils (HT & LT) to the legs of the coil assembly and fitting of the core and making connections of the coil assembly. Lowering of the coil assembly in the container after making proper connections. Providing and filling of fresh transformer oil 120 litres approximately in the tank of the transformer. Providing and fitting of HT bush rods, set of gasket, sundry items and insulation required. Complete assembling of transformer using new nuts, bolts and washers as per site requirement. Making all the electrical connections on HT and LT side along with proper insulation. Checking for continuity, insulation and putting the transformer on no load and then on full load. Complete Job includes cost of material, skilled/semi-skilled labour charges, carriage/shifting charges, hire charges of tools and tackles required at LIS Miari Complete Job. | 1 | 01 job | 93,200 ₹93,200 | 92,500 ₹92,500 | 93,500 ₹93,500 |
| 2.00 | Providing/fitting of 320 Amp Main switch at LIS Miari in place of worn out/damaged one. The newly installed main switch is to be connected with stabilizer with the existing armoured Al cable from LT side of HT/LT transformer to supply end of 320 Amp Main switch, and from Load end of main switch to input terminals of Voltage stabilizer with new thimbles of suitable current carrying capacity. The job involves cost of material, labour, tools and tackles with carriage including testing and commissioning. | 1 | 01 job | 57,200 ₹57,200 | 56,500 ₹56,500 | 57,800 ₹57,800 |
| 3.00 | Repairs/Servicing of the LT Control Panel for 2x75HP Motors installed at LIS Miari. The job involves disconnecting the incoming and outgoing cables of L.T. control Panel. Dismantling / disconnecting all the components inside the control panel i.e relays, MCCB,s voltmeter, ammeter, selector switches , busbars, HRC fuses etc. cleaning of the body from inside and outside of the L.T control Panel. Cleaning of internal connections , busbars and other recommended chemicals and then fitting to their respective positions in the panel. Providing/Fitting of main incomer MCCB 250 Amp & outgoing-2 Nos. 150 Amp MCCB of pumping unit No. 1 in place of damaged MCCBs. Re wiring of the control panel with new copper cable of appropriate size. p/f of 2 no. amperemeter by replacing old damged ones.Complete job includes cost of material and labour charges for skilled and semi skilled labour, hire charges of tools and tackles to be employed at site for execution of job. | 1 | 01 job | 85,900 ₹85,900 | 85,000 ₹85,000 | 86,500 ₹86,500 |
Tender Value
Refer Docs
EMD Value
₹7,500
Closing Date
15 Jan 2026, 12:00 pmClosed
Executive Engg. MICD Jammu
O/O Executive Engg. MICD jammu
Repair of 250 KVA Electric Transformer of LIS Miari along with allied works
2026_IFC_300115_1
MICD/J/52 dated 08-01-2026
Open Tender
Electrical and Maintenance Works
7 days
Miari
Please refer Tender documents.
9 documents required · 9 mandatory
₹200
Executive Engg. MICD jammu
₹7,500
6 Feb 2026
8 Jan 2026
15 Jan 2026
8 Jan 2026
15 Jan 2026
8 Jan 2026
Repair to 250 KVA LT electric transformer installed at LIS Miari by way of disconnecting of HT and LT line connections from transformer. Removing the top cover after unscrewing all the nuts and bolts along with dismantling of HT & LT bushes. Draining out of transformer oil from transformer tank at site. Taking out the coil assembly using chain pulley and other allied tools and tackles. Dismantling of damaged HT coils-12 nos and LT Coils- 03 nos from the coil assembly at site. Carriage of damaged coils to road side using tools, tackles and manual labour through hilly terrain. Loading in mechanical transport for further shifting to workshop for repair. Dismantling of coils at workshop and rewinding of HT coils with the aluminium wire of requisite specifications as per original design and varnishing complete. Dehydrating/drying the coils. Reconditioning of LT coils by way of rewinding of the aluminium coils as per original design with insulation material and varnishing complete. Then carriage back of newly rewound coils along with other allied material to the site of installation in similar manner. Servicing, cleaning and flushing of transformer tank by using appropriate chemicals to clean all the deposits and repair to radiator of the transformer to plug the leakage at multiple spots, drying completely. Fitting of the newly rewound coils (HT & LT) to the legs of the coil assembly and fitting of the core and making connections of the coil assembly. Lowering of the coil assembly in the container after making proper connections. Providing and filling of fresh transformer oil 120 litres approximately in the tank of the transformer. Providing and fitting of HT bush rods, set of gasket, sundry items and insulation required. Complete assembling of transformer using new nuts, bolts and washers as per site requirement. Making all the electrical connections on HT and LT side along with proper insulation. Checking for continuity, insulation and putting the transformer on no load and then on full load. Complete Job includes cost of material, skilled/semi-skilled labour charges, carriage/shifting charges, hire charges of tools and tackles required at LIS Miari Complete Job.
Providing/fitting of 320 Amp Main switch at LIS Miari in place of worn out/damaged one. The newly installed main switch is to be connected with stabilizer with the existing armoured Al cable from LT side of HT/LT transformer to supply end of 320 Amp Main switch, and from Load end of main switch to input terminals of Voltage stabilizer with new thimbles of suitable current carrying capacity. The job involves cost of material, labour, tools and tackles with carriage including testing and commissioning.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
BOQ_973688.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid