Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC | ₹14.1 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹19.1 L+₹5.0 L (35.5%)Rejected-Finance | ₹19.1 L+₹5.0 L (35.5%) | L2 | Rejected-Finance BIDDER NOT LOWEST |
| 3 | L3₹22.5 L+₹8.4 L (59.7%)Rejected-Finance 00 BACHUAPAR RAJESULTANPUR ALAPUR AMBEDKAR NAGAR UTTAR PRADESH 224176 | AMBEDKAR NAGAR | UTTAR PRADESH | 224176 | ₹22.5 L+₹8.4 L (59.7%) | L3 | Rejected-Finance BIDDER NOT LOWEST |
| 4 | L4₹24.3 L+₹10.2 L (72.6%)Rejected-Finance | ₹24.3 L+₹10.2 L (72.6%) | L4 | Rejected-Finance BIDDER NOT LOWEST |
| 5 | L5₹26.0 L+₹11.9 L (84.5%)Rejected-Finance | ₹26.0 L+₹11.9 L (84.5%) | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
19 Sept 2023, 6:00 pmClosed
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
REPAIR REPLACEMENT OF LT UG LT PANEL FEEDER PILLAR BOX DBS AND STREET LIGHT FITTINGS LT UG CABLE AT SALARIA OFFICERS ENCLAVE AT DWARKA UNDER GE WEST DELHI CANTT 10
2023_MES_612164_1
GE/DW-75/2023-24
Open Tender
Civil Works
Item Rate
180 days
SALARIA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST DELHI CANTT
₹70,000
25 Oct 2023
24 Aug 2023
21 Sept 2023
24 Aug 2023
19 Sept 2023
7 Sept 2023
Amount
M&L for excavation in trenches in soft soil n.exc 1.5 Mtr wide and n.exc 1.5 meter in depth for laying of cables/pole etc setting out trimming the site forming bottom surface to required level complete all as specified and directed .
M&L for returning filling in-trenches including spreading leveling watering and well ramming in layers with soft/loose/dense soil n.exc 25 cm thick in each layer of soil complete all as specified and directed
M&L for removing/excavated soil to a distance n.exc 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed
M&L for sand cushioning with a layer of sand Jamuna 23 cm thick (8 cm under and 15 cm above the cable) in trenches complete all as specified and as directed
M&L for fixing old serviciable un-reinforced precast concrete cable covers for cable protection of class LV type 1 flat of size 250 x150 x 40 mm.complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable covers for cable protection of class LV type 1 flat of size 250 x150 x 40 mm.complete all as specified and directed.
M&L for earthling complete with GI earth plate electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 Mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 Mtrs below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI wire 4 mm by means of bolts, nuts, chuck nuts, and washers and protected by medium grade 50 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering , including funnel, wire mesh, RCC 75 mm thick pit cover 1:2:4 type B-1 using 20 mm graded stone aggregate with and including 8 mm dia TMT bars @ 100 mm centre to centre both ways ,PCC chamber pit with PCC 1:2:4 B-1 ( including necessary form work, excavation and earth work, disposal of surplus soil two a distance not exc. 50 Mtrs) complete all as specified and shown in SSR – Part I 2009.
Supply and fix in replacement Timer for 24 hrs including necessary wiring from contactor and supply connections.complete all as specified and directed.
M&L LT 1100 volts straight through joints kit epoxy type of size 16 to 95 sqmm 3.5 core, jointing LT UG cable complete all as specified and directed.
M&L LT 1100 volts straight through joints kit epoxy type of size 120 to 240 sqmm 3.5 core, jointing LT UG cable complete all as specified and directed.
S&F MCCB 3 pole suitable for AC 3 phase 415 volt 50 HZ, 400 Amp, 36 KA, with thermal magnetic release fixed on existing LT panel complete all as specified and directed. complete all as specified and directed. ' Note: Rate quoted deemed to include taking down the existing MCCB from panel board and incoming / outgoing cable and fix the new MCCB in position at panel board / incoming / outgoing cable connections of any size/ rating.
All as per item 11 but 250 Amps, 36 KA.complete all as specified and directed.
All as per item 11 but 200 Amps, 36 KA.complete all as specified and directed.
All as per item 11 but 160 Amps, 36 KA.complete all as specified and directed.
All as per item 11 but 125 Amp, 25 KA.complete all as specified and directed.
All as per item 11 but 100 Amp, 16 KA.complete all as specified and directed.
S&F in repair MCB/TPN , 100 Amp 415 volt 16/10 KA complete all as specified and directed.
S&F in repair MCB/TP 100 Amp 415 volt 16/10 KA complete all as specified and directed.
Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Servicing of DG sets 140 KVA Make: Greaves cotton installed at Salaria PH; including routine checking of all Engine and alternator parts for its servicing/durability complete all as per manufacturer recommendatations and including repair of followings parts in all DGs :- (a) Drain out the lubricating oil from sump and refilling after proper cleaning. (b) Replace Engine Oil filter cartridge with New one. (c) Replace fuel filter cartridge with New one. (d) Replace coolant fine filter with new one. (e) Replace air filter with New one.
S & F in repair Oil filter as per exsting make and size for DG Set of capacity 140 KVA as per sample.
S & F in repair diesel Fuel filter Primary and secondary as per exsting make and size for DG Set of capacity 140 KVA as per sample. .
S & F in repair Air filter as per exsting make and size for DG Set of capacity 140 KVA as per sample. .
Supply and Filing of coolant in DGs all as specified and directed by Enger-in-Charge.
Supply and Filling of lubricant oil (15-20)W-40 in replacemen in DGs all as specified and directed
M & L for taking down repair and refixing of self starter of 140 KVA DG capacity including repair of burn field coil repair of armature and carbon bush holder and carbon bush point and solinoid coil, complete all as specified.
M & L for Repair/servicing of radiator assembly of 140 KVA DG Set after dismanteling and removing cooling fans, guard plates and lowering the same from engine after draining out water from radiator and scrapping / removing sludge / scale inside tank including repair. Remounting the same at its original position and filling of pre mixed coolent as per the ratio fixed by manufacturer measured seperately and testing complete all as directed
M & L for Locating electrical faults and repair work in underground LT cable of size 150 to 240 Sqmm whenever any fault arises at Salaria officers Enclave area, making complete supply system functional dully rectifying and repair work complete all as specified and directed. Note: (a) Whenever any breakdown reported the Contractor will have to take immeadiate action and send skilled Technecian/Tools immediately on site. (b) Any parts required to be replaced during repair work shall be measured and paid for separately.
M & L for Locating electrical faults and repair work in underground LT cable of size 16 to 85 Sqmm whenever any fault arises at Salaria officers Enclave area, making complete supply system functional dully rectifying and repair work complete all as specified and directed. Note: (a) Whenever any breakdown reported the Contractor will have to take immeadiate action and send skilled Technecian/Tools immediately on site. (b) Any parts required to be replaced during repair work shall be measured and paid for separately.
M & L servicing of feeder pillar box, after disconnecting the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified, including painting of the feeder pillar.Complete all as specified and directed.
Supply and fix in replacement junction box made from SMC/FRP sheet ready made of size having 100 A capacity for RYB and neutral with aluminium bus bar including all necessary insulators,nut bolts, screw fix to street light pole,joint the incoming and outgoing cable with suitable no of aluminium lugs fixed to Pole /Wall with the help of suitable nuts and bolts. Complete all as specified and directed.
Supply and fix in replacement 3 Pole contactor MNX 18, including necessary connections for incoming and outgoing connections .
M&L for scrapping/removing rusted partials on surface of existing single swan neck steel tubular electric street light pole including nut and bolts after cleaning Appling one coat of red oxide and two coats of aluminium paint including stranded size of numbering and alternate strip black and yellow synthetic enamelled painting from the coping of pole as directed and two coats of cement base paint on surface area of copping complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning LT, XLPE insulated armoured, heavy duty aluminium conductor electric cable 1100 Volts grade, cross sectional area 240 Sqmm, 3.5 core including taking out old existing cable in trench/wall/pipes feeder connections complete all as specified and directed.
All as per item No 34 but 3.5 core 185 sqmm.complete all as specified and directed.
All as per item No 34 but 3.5 core 50 sqmm.complete all as specified and directed.
All as per item No 34 but 3.5 core 25 sqmm.complete all as specified and directed.
Supply and fixing passing through cable 3 core PVC insulated unsheathed multistranded copper conductor of size 2.5 Sqmm from junction box to street light fitting complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 168605.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum.
ACR ENTERPRISES
SB ENTERPRISES
Surjit and Sons
M/s S.G. BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .