| 1 | L1₹31.9 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹31.9 L Quoted ₹33.6 L | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE |
| 2 | L2₹34.8 L+₹1.2 L (3.62%)Rejected-Finance | ₹34.8 L+₹1.2 L (3.62%) | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
| 3 | L3₹37.5 L+₹3.9 L (11.5%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | ₹37.5 L+₹3.9 L (11.5%) | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
| 4 | L4₹38.5 L+₹4.9 L (14.6%)Rejected-Finance VILL RATTANPUR PO TEH JOURIAN DISTT JAMMU J K 181202 | JAMMU | JAMMU AND KASHMIR | 181202 | ₹38.5 L+₹4.9 L (14.6%) | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
| 5 | L5₹39.9 L+₹6.3 L (18.7%)Rejected-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | ₹39.9 L+₹6.3 L (18.7%) | L5 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹38.6 L
EMD Value
₹77,200
Closing Date
15 Feb 2023, 6:00 pmClosed
GE (SOUTH) AKHNOOR
GE (SOUTH) AKHNOOR C/O 56APO
SPECIAL REPAIR TO OH LINE AND UG CABLE AND SPECIAL REPAIR TO EARTHING AND LIGHTENING CONDUCTOR AT PALLANWALA UNDER GE (SOUTH) AKHNOR
2023_MES_575955_1
GES/AKH-54/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY b(i)
9 documents required · 9 mandatory
₹500
GE (SOUTH) AKHNOOR
₹77,200
23 Feb 2023
19 Jan 2023
17 Feb 2023
19 Jan 2023
15 Feb 2023
1 Feb 2023
Amount
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for foundations/ laying of cables/pipes, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and not exceeding 3.0 mtr in depth and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Returning filling in incl spreading watering and well ramming in layers in hard/dense soil each not exceeding 25cm thick complete all as specified.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified.
GI pipes/ Tubes, 'light grade', galvanised, 80mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
GI pipes/ Tubes, 'light grade', galvanised, 50mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
GI pipes/ Tubes, 'light grade', galvanised, 40mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing of 40/50mm dia pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed.
S&F in replacement of Air termination, single pointed aluminium rod 12mm dia and 300mm long, including necessary fittings and fixtures, complete all as directed by Engr-in-charge.
Taking down old earthing strip of any description, complete all as specified and as directed.
S&F in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as directed by Engr-in-charge.
Plain cement concrete Nominal Mix M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Tubes,Medium grade' galvanised, 50mm bore, ISI marked with all fittings and fixed to walls and ceilings or laid in floors for lightening conductor, complete all as specified and as directed. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.
S&F in replacement of Aluminium strip, size 25x3.15m with saddles and fixing screws etc.; fixed along with external surface from lightening arrester at roof top to test point conductors above ground, complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe of GI tubing light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
S&F LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 150 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note : - (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
S&F LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note : - (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
S&F LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 70 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note : - (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
S&F XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note : - (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
S&F LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 25 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note : - (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
S&F LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm 4.0 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note : - (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
Replacement of old damaged, PCC poles with new steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-31 (9.00 meters long), including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the exposed surface and two coats of bitumiunous paint on embedded surfaces, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10 (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
M&L 1100V Grade L.T. Aerial Bunched Cable of size 3x16 + 1x16 + 1x16 sq.mm (Phase Wire + Neutral Wire + Insulated Messenger Wire) having three Power Core & One insulated Messenger Core of stranded compacted circular Aluminium Black coloured XLPE insulated & Core identification by ridges, one, two and three & four respectively. Neutral Wire should be of stranded compacted Circular Aluminium Alloy Conductor conforming to IS 8130/1984, IS-398(Part-IV)/1979 and IS-14255/1995 with upto date amendments, if any, composition of phase wire, neutral wire and messeanger wire all shall conform to manufacturer instructions subject to compliance with Electricty manual /Indian Electricity Act -2003, and there by changes in the size of messeanger and neutral wire, nothing shall be admissible on this ground, including necessary connecting accessories like Anchor Clamps (3 Bolt and 2 Bolt Type), Eye hook with Suspension Clamp Assembly, PCC Pole Clamp, Insulation Piercing Connectors with cover or P.G.Connectors with insulation cover,Water Proof pre-insulated Hexagonal Compression Connectors & Lugs etc , complete all as specified and as directed by Engr-in-Charge. Make: Havells/ Poycab/Grand lay/KEI.
S&F in replacement of Factory made SMC junction box/ cut-out box, made with 3.15mm thick CRCA mild steel sheet, vermin proof, dust proof, for outdoor use, having internal dimensions 300x200x105mm, painted externally and internally, suitable for road/ street lighting for 3-phase/ 4-core high wattage LED based lighting system for industrial applications, suitable for pole mounting, having one No MCB of 15 Amps, Single Pole and Neutral, including aluminium bus bars of 200 Amps rating duly drilled holes for connections, cable glands, clamps etc for making necessary connections, including mild steel iron flat size 25x4mm having holes, nuts, bolts, washers, for fixing on poles, complete all as specified and directed by Engineer-In-Charge. Make: Sintex cat part No GS-JB-3020 or equivelent in Havells/L&T/HPL.
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 7700 Lm and system wattage not exceeding 70W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified. Make : Bajaj cat part No ENXT P 84L WH PO PC SD or Equivalent makes in Wipro/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Replacement of old unserviceable/ damaged Mild steel in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged stay assembly with new stay assembly, galvanised iron, complete with accessories as shown in electrical plate No-1, diameter of stay rod 20mm dia, including galvanised iron stay plate 300x300x6mm, galvanised iron thimble, 14mm dia 400mm long stay bow and galvanised iron nuts bolts, washers including loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 65x90mm, clearance of hole 16.0mm, including stay wire, galvanised iron, stay wire 7/4mm stranded, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and PCC shall be measured and paid separately under relevant item of Schedule ‘A’/ BOQ.
Dismantling of ACSR or AAC conductors, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of insulators of any type and any description, complete all as specified and as directed by Engineer-In-Charge.
taking down existimg worn out unde ground XLPE cable of any size and description, complete all as specified and as directed by Engineer-In-Charge. Note : Necessary earthwork for taking out old cable shall be deemed to be included in the quoted rate and nothing extra shall be paid on this account.
Amount of Schedule of credit of for Rs 1,72,305.00 shall be deducted from quoted amount.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .