| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 CrAccepted-AOC NATIONAL HIGHWAY BYE PASS CROSSING ATHWAJAN SRINAGAR 191101 KASHMIR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 191101 | ₹29.5 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹30.8 CrRejected-AOC CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹30.8 Cr | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹33.7 CrRejected-AOC 260 RITAMBARA BUILDING TRIBHUWAN COMPLEX ISHWAR NAGAR WEST NEW DELHI 110 065 | ₹33.7 Cr | L3 | Rejected-AOC L3 Bidder |
| 4 | L4₹36.6 CrRejected-AOC | ₹36.6 Cr | L4 | Rejected-AOC L4 Bidder |
Tender Value
₹31.2 Cr
EMD Value
₹62.4 L
Closing Date
23 Mar 2022, 4:00 pmClosed
Chief Engineer, Srinagar Smart City Ltd.
1st Floor Budshah Building Lal Chowk Srinagar.
Construction of Traditional Souq Market and Craft Centre at Sector-6 Batamaloo including Landscaping, Development of Parking, Central Plaza and Pedestrian Seating Spaces
2022_SSC_162722_1
E-N.I.T NO. 18-SSCL OF 03-2022 DT. 02-03-2022
Open Tender
Civil Works
180 days
Srinagar
Refer to Standard Bid Document
4 documents required · 4 mandatory
₹20,000
Yes
CEO Srinagar Smart City Ltd
₹62.4 L
Yes
Office of Chief Engineer, Srinagar Smart City Ltd.
21 Nov 2022
2 Mar 2022
24 Mar 2022
2 Mar 2022
23 Mar 2022
2 Mar 2022
15 Mar 2022
Amount
Civil Works:
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level
Extra for providing richer mixes at all floor lavelsProviding M-35 grade concrete instead of M-25 grade BMC/RMC. (Note : Cement content considered in M-35 is @ 350 kg/cum).
Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete mix, diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) By percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, 450 mm dia piles
Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete mix, diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) By Crawler mounted, telescopic boom hydraulic pilling Rig all complete. 1000 mm dia piles
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms.
Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.6 Columns, pillars, piers, abutments, posts and struts.
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform with waterproofing ply 12 mm thick
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Brick work in plain arches in superstructure above plinth level and upto floor V level including centering, shuttering and curing complete for span upto 6 meters with common burnt clay (non-modular) bricks of class designation 7.5 in cement mortar 1:3 ( 1 cement : 3 coarse sand )
18mm Cement plaster in two coats under layer 12mm thick cement plaster 1 : 5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1 : 6 (1 cement : 6 fine sand)
Providing and applying average 15 mm thick cement plaster in single coat in cement mortar 1:6 upto 10 m above ground including scaffolding etc. complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge .
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 1 80x1.20 mm M.S. laths with 1.20 mm thick top cover
Extra for providing mechanical device chain crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 500x500 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 500x500 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 , of approved make, in all colours, shades of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Polished Granite stone flooring in required and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing 18 mm thick granite, mirror polished, machine cut forfloors, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite Stone
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 1 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing. One face dressed Rough chisel dressed
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1cement:4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in charge.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.63 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as perIS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre and of required colour and shade or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 80 mm thick with zinc coating not less than 275 gram/m2
Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodized aluminum (with 15 micron anodic coating) Tsections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminum frame work shall be paid separately)
Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain or design particle board ceiling tiles.
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Providing and fixing 6mm dia. G.I level adjusting hangers (upto 1200mm length) fixed to roof slabs by means of ceiling cleats made out of G.I flat 40x3mm size 60 mm long and stainless steel expandable dash fasteners 12.5 mm dia. 50 mm long complete as per direction of Engineer-in-charge
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick First Class kail wood
Providing and fixing plained eaves boarding. 2nd class kail wood 300x40 mm (nominal size)
Providing and fixing of of 50x50 mm thick kail wood cornice including all carriage, complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately)::Second class Deodar wood
Providing and fixing to existing door frames,30mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 60x30mm and wall thickness 2mm +/-0.2mm with inbuilt decorative moulding edging on one sides. TThe pannels filled vertically and tie bar at two places by inserting horizontally 6mm galvanized MS rod and fastened with nuts and washers, complete as per manufacturers’ specification and direction of engineer-in-charge.
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 100x58x1.90 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. :150x10 mm
Providing and fixing bright finished brass handles with screws etc. complete : 125 mm
Providing and fixing following Fitings with necessary screws etc. complete. Aldrops
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern,including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P.brass pillar taps
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the wall sand floors wherever required:Range of three half stall urinals with 10 litre P.V.C.automatic flushing cistern
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing
Providing and fixing WC with PVC low level flushing cistern with all fittings SS Orissa pattern WC pan size 585 x 480 mm , 10 litre low level white P.V.C. flushing cistern,including flush pipe, , conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms
Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore 125 mm long foam flow, weighing not less than 120 gms.
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms
Providing and Fixing of the following CP Fittings PTMT-Towel Rail (450mm)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
Providing and Fixing of the following CP Fittings PVC waste pipe asper design and as approved by Engineer in cgarge.
Providing and Fixing of the following CP Fittings Connector 0.60 m as per design and as approved by engineer in charge
Providing and Fixing of the following CP Fittings Long Bend as per design and as approved by Engineer in charge
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.Medium 15 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.Medium 20 mm dia. nominal bore
Providing and Fixing ball valve (brass) of approved quality high or low pressure, withplastic floats complete 20 mm dia nominal bore
Providing and Fixing G.I union in G.I pipe including cutting and threading the pipe and making long screws etc. complete(new work) 20 mm dia union
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. For 22.22 mmx15.88 mm outer dia pipe
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour 20 mm nominal bore, weighing not less than 40gms
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 15 mm nominal bore
Providing and Fixing PVC Fittings 75 mm dia Plain bend
Providing and Fixing PVC Fittings 75 mm dia door bend
Providing and Fixing PVC Fittings 75 mm dia Trap
Providing and Fixing PVC Fittings 75 mm dia Cowl
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size),Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and Fixing Aluminium Partition with Doors For all Toilet with all fixtures etc.,as per approved drawing and as per the direction of Engineer in charge.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment)
Supplying and stacking at site dump manure from approved source including carriage complete (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of I.S. designation 4.75 mm
Spreading of sludge, dump manure or/and good earth in required thickness as per directions of officer in-charge (cost of sludge, dump manure or/and good earth to be paid separately
Pre-casting & Placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. pipe 40mm dia and 450mm long with 150x150x6 mm M.S. plate welded at bottom and embeded 150 mm in cement concrete 1: 3: 6 (1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design. 20.2.1 All around S.W. pipe 20.2.1.5 250 mm diameter S.W. pipe
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x450x50 mm reinforced with 8 mm dia four nos longitudinal and 9nos cross sectional T.M.T hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S flats of size 50mmx1.6mm complete all as per direction of Engineer-in-charge.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer,
Dry random rubble masonry with hard stone in foundation and plinth: With bond stone.
Dewatering the excavated trenches/pits, pools of water, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge including cost of machinery, labour, fuel, pipe and it's accessories etc. complete. Note : This item will be operated/executed with the prior specific sanction of the Engineer in charge
Electrical Works
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying installation and testing of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Façade Lighting
Supplying and erecting LED flexible strip light 5 mtr length upto 75W conforming IP 65 of any colour with driver complete. Mouting channel in light weight, made of aluminium(20(W)x14(H)) with diffuser screen, LED-DC 24V, source Efficacy>80lm/W, Nos. of LED's-180/Meter minimum,LED-Epistar/equivalent SMD type,yellow glue 3M,120 degree beam angle,It also includes External IP67 metal body Electronic Power Supply for LED Module,which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection
Supplying installation and testing of LED FIXTURE - Circular Ground Buried Light , 2-4W,LED,3000k, IP 67 Light: The housing in light weight, made of high strength die cast aluminium .Protection screen in tempered glass with high impact resistance. Stainless Steel Cover. Pure Polyester powder coating. Precise structure and multi-protection silicon rubber seal guarantees the fixture IP67 rated. Height – 98mm, Dia.-85mm, Weight - 0.55Kgs. Power LED Module with high efficacy LED's, on Printed Circuit Board with metal core plate.,Electronic Power Supply for LED Module,which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection.Lens made of PC which should offer minimum 4 different beam angles 15deg./30deg./45deg./60deg. to serve different lighting needs.Estimated LED Lifetime is L70-50,000 hours minimum.Minimum Light fixture Lumen output is 150Lumens.
Supplying installation and testing of 12M -Spot Light, 25-30W,LED, 3000k 12M -Body-Die-casting aluminium Body with Surface Anti-ageing electrostatic spray processing & screen in tempered glass. Body colour-RAL 9004 + RAL 9018 Matt ,Dimension-140mm(Dia.)x180mm(L)x152mm(W)x192mm(H),Weight-2kgs. , Electronic Driver which offers Protection against Short Circuit, Over- Voltage & Over- Current, IP 65 protection,CRI > 70,voltage input AC100-264V.Estimated Lifetime-L70 @ 50,000hours minimum
Supplying installation and testing of Wall Recessed Light(step light), 4-6W,LED,3000k Body-Die-casting aluminium Body with screen in tempered glass. Electronic Driver which offers Protection against Short Circuit, Over- Voltage & Over- Current, IP 54 protection,CRI > 70,voltage input AC100-240V.Body colour-RAL 9005 Matt ,Dimension-162mm(L)x96mm(H)x65mm(D),Weight-0.5kg. Estimated Lifetime-L70 @ 50,000hours minimum.
Supplying installation and testing of Outdoor 8 MP Starlight High Speed Network PTZ Camera with 36x optical Zoom, 1 / 1.8” CMOS , Focal Length: 5.8~201mm or better, 300 Meters IR distance, Auto tracking, 30fps at 3840x2160, 4 CH Alarm in and 2 CH Alarm out, Audio in and Out, VCA (Object classes like humans detection, line crossing, Object Analytics like unattended and Missing object detection, People counting, Fence Guard/ Perimeter detection, Loitering detection, Video Motion Detection, active tampering alarm), ONVIF(Profile S, Q and T ), Protocols (IPv4/v6, HTTP, FTP, SMTP, UPnP, SNMPv3, RTSP, Samba, AAA, Qos), Certifications (-40 °C to 50 °C UL/cUL, CE, FCC,EN/IEC, IP67, IK10,IS/BIS.)
Supplying installation and testing of 16ch 4K network video recorder with HDMI, ONVIF Support, 4 HDD Support, Support Smart Video Analytics and RAID 0,1,5,10 , 1CH 4K HDMI, 1CH VGA,HA and ANR Support, Certifications (CE, FCC, UL/IS)
Supplying installation and testing of 8TB Surveillance Hard disk
Supplying installation and testing of Layer2 Industrial Managed Gigabit PoE Switch with 4# 10/100/1000 BaseT PoE Ports and 2# SFP Slots, AC Power Supply (PoE Power Budget: 120W), 4K Vlan, 8K Mac, IPv6 Dual Stack, RJ45 Console port, G.8032 ERPS, IP30 rating, Operating temperature - 40 ~ 75°C or better , Certifications (CE, FCC, UL, ROHS, UL 60950-1 (should not be an UL Multi listed certificate or report)IEC 60950-1, FCC Part 15 Subpart B Class A, EN 55022/EN55032 Class A , EN 61000-4-2 , EN 61000-4-3 , EN 61000-4-4 , EN 61000-4-5 , EN 61000-4-6 , EN 61000-4-8 , EN 50121-4 , IEC 60068-2-27 , IEC 60068-2-32 , IEC 60068-2-6 ). All Switches and modules from same OEM
Supplying installation and testing of Layer3 Managed Gigabit Switch with 24# 10/100/1000 BaseT Ports, 4# 10G SFP+ Slots, AC Power Supply, 3K routing table, ospfv3, BGP4, Multicast routing, PIM DM/SM, VRRP. All Switches and modules from same OEM
Supplying installation and testing of 15U 600x450mm Wall Mounted Network Rack with Tempered glass front door, Adjustable 19" Mounting Rails with lock and key, Power strips for Rack with 6 Sockets, each socket supports 230v, 5A, 1UCable Manager for Network Rack, 90Cfm Fans, 115~240V A C Fan f or Rack, Fan Tray For network Rack, Hardware Screw Packet
Supplying installation and testing of 12U 550x400mm Outdoor Rack, Adjustable 19" Mounting Rails with lock and key, Power strips for Rack with 6 Sockets, each socket supports 230v, 5A, 1U Cable Manager for Network Rack, 90Cfm Fans, 115~240V A C Fan f or Rack, Fan Tray For network Rack, Hardware Screw Packet
Supplying installation and testing of Single mode Gigabit 1310nm Mini-GBIC module supports up to 10km
Supplying installation and testing of CAT 6 Unshielded Twisted Pair, 23AWG, FRPVC sheath, 305meter, ETL Verified, Zero bit error tested
Supplying installation and testing of 55" 4K 24/7 Display
Supplying installation and testing of Cable laying.
Supplying installation and testing of Large Poles with electrical
Supplying installation and testing of 1KVA Field UPS
Supplying installation and testing of 3KVA Control Room UPS
Installation and Commissioning
Street Lighting
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation
Providing and erecting galvanised 1000mm double arm sword type bracket
Supplying, erecting & marking SPN MCB 6A to 32A, B- series (for lighting) in provided distribution board
Street Light Fitting
Supplying and erecting LED street light fitting 150 W, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete
Eathing & Foundation
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete.
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia.G.l. Rod complete with all materials
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole).
Cable
Supplying, erecting & terminating XPLE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe
Supplying, erecting & terminating XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm.(12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe
Supplying, erecting & terminating XLPE armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm.(12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe
Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe.
Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Enclosers
Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing PVC armoured cable on wall/pole
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Street Light Control Panel
Inspection Chamber
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete.
HIGH MAST
Supplying and erecting 20 m (clear height) High Mast (Top- 150mm, Bottom- 460mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 12 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation
Supplying and erecting Outdoor Stand Mounted Feeder Pillar for highmast of the same manufacturer with 63A TPN MCB incomer,single dial timer switch, 45A TP contactor for automatic switching of luminaries, 2 nos 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self-lock, gasket and slanting top erected with CC foundation complete.
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 20 m raising lowering high mast) .
Supplying and erecting LED Flood light fitting of 200W,including lamp,with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete.
Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe.
Metering Connection
Supplying, erecting & terminating XLPE armoured cable 3½ core120 sq. mm. aluminium conductor with continuous 12.97 sq.mm. (8 SWG) G.I. earth wire complete erected with glands & lugs,on wall/ trusses/pole or laid in provided trench/ pipe.
Supplying and erecting Three phase smart energy meter DLMS compliance with 3x240V 50 cycles AC supply 10-60 A, ISI mark, accuracy class 1.0 with backlit LCD display, measuring & display V, I, kW, kWh, PF, kVA, kVAr, MD, day, week, month & with communication module configurable for GSM/Wi-Fi, IrDA/Bluetooth, complete provided panel with calibration certificate from manufacturer & duly wired with required size of PVC wires.
Supplying & laying (including excavation) 25 cm Dia half round RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Making trench of suitable width and depth in hard murum / tar road for laying provided LT cable up to and including 16 sq. mm complete.
Making trench of suitable width and depth in hard murum / tar road for laying provided LT cable of 16 sq. mm & above and covered with half round hume pipe complete.
HT Underground Cabling Work
Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 11kV, Single core 240 mm2 Aluminium round wire Armoured XLPE Cable , FRLS (With Three spare cables) in provided cable duct bank in proper dressing of the cable in an approved maner,complete as required & as per KPDD Specification
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Straight Through Joints : Heat Shrinkable type single core H.T. Cable straight Through Joints along with boots ( SILCAB - T) to accommodate following size of 11 KV XLPE(E) aluminium cable size 400,185,240 & 120 mm2 compplete with all kit contents including earth continuity connection along with 3 Nos.Crimping type aluminium lugs/thimbles of suitable capacity incluiding making joints etc.in an approved manner complete as required & as per KPDD Specification
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Route marker along the cable/cable duct bank in complete manner as per required & as per KPDD Specification
Supply, Laying, Testing & Commissioning of warning Tap in complete manner as per required & as per KPDD Specification.
Supply, Laying, Testing & Commissioning of Cable Termination Kits (indoor/outdoor) : Heat Shrinkable type ( Indoor/Outdoor) termination along with necessary accessories to accommodate for single core 630,400 & 120 mm2 ,11 Kv ( XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required & as per KPDD Specification
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 9 Mtr. Long Pole( ST-540 SP15) IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level including Aluminium Paint of approved brand with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
Supply, Installation, Testing & Commissioning of 11kV GO AB Switch with all its accessories
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. Pipe Earthing : Earthing With G.I. Strip,G.I.earth pipe 4.5 meter long,40mm dia including accessories & providing masonry enclosure with cover plate having locking arrangment & watering pipe etc.with charcoal & salt as required Complete as per KPDD Specification
LT Underground Cabling Work
Supply,Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 240 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type( With 3-ɸ, 1N, 1 Ckt spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as reauried & as per KPDD Specification.
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Straight Through Joints for cables. Heat Shrinkable type Straight Through Joints along with necessary accessories to accommodate for 630,500,400,300 & 120 mm2 ,3 1/2 1100 Volt ( XLPE(E) aliuminum cable complete with all kit contents including earth continuity of suitable capacity including making joints etc. in an approved manner complete as required
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Route marker along the cable/cable duct bank in complete manner as per required
Supply, Laying, Testing & Commissioning of warning Tap in complete manner as required.
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Cable Termination Kits (indoor/outdoor). Heat Shrinkable type ( Indoor/Outdoor) termination along with necessary accessories to accommodate for single core 630,500, 400,300 & 120 mm2 ,3 1/2 Kv ( XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Earthing Complete. Earthing With G.I. Strip,G.I.earth pipe 4.5 meter long,40mm dia including accessories & providing masonry enclosure with cover plate having locking arrangment & watering pipe etc.with charcoal & salt as required.
Compact Substation
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Packaged Substation - 630kVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 630kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 1000 A load break switch & 1 no. 1000A tee off with SF6 circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T' etc. B) 1 no. 11 kV / 433V, 630 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding an standard fittings C) 1 No. 433V, 300A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp.each. Including 3phase 4 wire energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB so as to enable the executing agency at site for connection with MCCB & when required.
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of MCCB as required for the outgoings of the existing PAC.Sub stations with necessary arrangement as required of specifications 400Amp.,4 pole,433V,25kA
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Providing of prefab bedding structure for 630KVA DT
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of of 11KV Trivectormeter including all accessories like CT/PT Unit , power cables etc
Feeder Pilliar
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for 3 phase, 415V, 1no of 250 Amps incoming 3 TP MCCBs (Breaking 50KA) fitted with outgoing 03 No 100 Amps SP MCCBs, 1No.100Amps 3 pole MCCB for outgoing LT cables, Distribution feeder Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7-tank process with PU painted Busbars(6 mm thickness) 4P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accesories 12 way Distribution Feeder Pillar.
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Support Galvanised angle frame and legs (50 mm x 50 mm x 6 mm) for Distribution Feeder Pillar , leg height 1m with 0.3m in soil approx 7 m @ 4.50Kg per mtr. as per site condition in complete manner with cutting ,bending,fabrication as required in complete manner
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Earthing Complete Earthing With G.I. Strip,G.I.earth pipe 2.5 meter long,20mm dia including accessories & providing masonry enclosure with cover plate having locking arrangment & watering pipe etc.with charcoal & salt as required
Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Cement grouting for support angle legs as per approved drawing in complete manner as required
Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 1 phase 2 wire, 415V, 1nos of 100 Amps incoming SP MCCBs fitted with outgoing 08 No 16 Amps SP MCBs for Service Connections, Distribution Service Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7-tank process with PU painted Busbars(4 mm thickness) 2P, Aluminium with heatshrinkable sleeves and adequate capacities complete with allaccesories 8 way Distribution Service Pillar with Kiosk Boxes for Housing Digital Energy Meters)for Distribution of Supply to consumers (8 way)
Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Support Galvanised angle frame and legs (50mm x 50 mm x 6 mm) for Distribution Feeder Pillar with leg height 1m with 0.3m in soil approx [email protected] per mtr
Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 95mm² 2 Core, 1P2W Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type(1-ɸ, 1N)
Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 10 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, PVCInsulated Stranded Conductor FRLS type
Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 1"/2" HDPE Conduits
Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Excavation in any type of soil including hard laterite soil
Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Cement grouting for HDPE Conduits
M M SHAWL ENGINEER AND CONTRACTORS PVT LTD
N S Associates PVt Ltd
M/s Harcharan Dass Gupta
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid