Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC LOWEST QUOTED | |
| 2 | L2₹10.5 L+₹24,449 (2.39%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 3 | L3₹11.0 L+₹75,028 (7.33%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
₹12.8 L
EMD Value
₹25,500
Closing Date
26 Aug 2020, 6:00 pmClosed
GE (AF) Udhampur
GE (AF) Udhampur Dhar Road
Provn of shed over main entrance gate with E M fittings at AF Station Udhampur
2020_MES_365066_1
GE/AFU-22/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Udhampur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Udhampur
₹25,500
Yes
12 Sept 2020
29 Jul 2020
28 Aug 2020
29 Jul 2020
26 Aug 2020
11 Aug 2020
Amount
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in foundation, filling & mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (design mix) M-25 ( using 20mm graded stone aggregate) in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
Use & waste of Form work to sides of concrete foundation, footings, bases of columns raft and raft beams, side and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for flat rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long, dia of neck 20 to 25 mm, complete all as specified.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates quality confirming to grade Fe-290-Gde E-165, complete all as specified.
Rolled mild steel as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, quality confirming to grade Fe-410-Gde E-250, complete all as specified.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa in roof covering/cladding to wall,fixed with self tapping screws complete, all as specified.
Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified.
Plain, galvanised, mild steel sheeting 1.25 mm, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) fixed with L/J type hooks/bolts and washers, in roofs, complete all as specified.
M&L for Cement concrete 100 mm thick 1:4:8 type D2 using 40mm graded stone aggregate as in sub base to floors finished rough complete all as specified and directed by Engineer-in-Charge.
100 mm thick, cement concrete type B-2, 1:2:4 using 40 mm graded stone aggregate, finished even & fair, as in floors, complete all as specified.
Two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
PVC SWR pipes, 110 mm external dia, type-B, ISI marked (IS:13592) double socketed in any length with rubber ring joints, fixed to walls with PVC clips or under floors ,complete all as specified. MAKE: SUPREME, FINOLEX, PRINCE .
Point wiring using approved colour coding as per IS for one light/bell/buzzer/fan point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 6 Amps socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 6 Amps socket outlet independent controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Switch modular type 6 AMP,one way , one module conforming to IS-3854 complete all as speciifed and as directed
Switch modular type, 16/20 Amp, one way, one module conforming to IS-3854 complete all as specified and as directed.
Socket shuttered outlet 2/3 pin, 6 Amp modular type, 2 modules complete all as specified and as directed.
Socket shuttered outlet 2-in-1, 6/16 Amp modular type, 2 modules complete all as specified and as directed.
Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed.
Lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connecting to the galvanised iron earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth strip protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore pipe for watering perforated at bottom 7.50 mtr long placed on top edge of earth plate, layers of common salt and charcoal filling, test point made out of 40mmx6mm flat iron with fixing arrangement funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electircal plate No. 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion including complete all as specified & directed by Engr-in-charge
Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable, complete all as specified and directed by engr-in-charge.
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable in repair , complete all as specified and directed by Engineer-in-Charge
GI tubes light grade 40 mm bore with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc and including sealing end of pipe with bituminous preformed wooden gutties, including taking down old unserviceable complete all as specified and directed by engr-in-charge.
MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 12 way SPN with 200 Amp rated bus bar 230 volt AC supply , complete all as specified and as directed. Make:Legrand /HAVELLS / SIEMENS/Schneider
M&L for rectangular block of second class hard wood of size 30cm x25cm x5cm closed recessed,complete all as specified and directed by Engr-in-charge.
Modular white cover plate with frame 3 module,complete all as specified and directed by Engr-in-charge.
Modular white cover plate with frame 4 module,complete all as specified and directed by Engr-in-charge.
Modular white cover plate with frame 6 module,complete all as specified and directed by Engr-in-charge.
Modular white cover plate with frame 8 module,complete all as specified and directed by Engr-in-charge.
MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic ,complete all as specified and as directed. Make:CAT PART NO:408618 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic, complete all as specified and as directed. Make:CAT PART NO:408620 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB single pole, 06-16Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic ,complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
MCB single pole, 32-63Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic ,complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
MCB SPN, 100Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic ,complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
S&F indoor decorative extruded aluminium anodised housing/CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink/aluminium housing for excellent heat dissipation; 4 feet (approx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified.. MAKE :CAT Part No:D532065 FOR Batten and rod-P08120 of Wipro or equavalent to Havells/Philips/Crompton Note :- The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. Note :- 1.5 cubic metre of soil shall be provided by the contractor from outside the MOD land for refilling the remaining portion of earth pit for increasing soil resistance without any extra cost to the Govt.
Supply, laying , jointing , commissioning and testing cable (armoured) XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 16 sqmm ,2 core with saddles and gutties, complete all as specified and directed by Engr-in-Charge
Supply & fixing wall mounted fan 400 mm sweep ,suitable for 220-240 V AC 50 HZ,1 Phase,complete all as specified and directed by Engineer-in-Charge.
Supply & fixing energy efficient star rated ceiling fan 1200 mm sweep with modular step type electronic regulator complete with connection upto ceiling rose ,complete all as specified and directed by Engineer-in-Charge.
SHIVAE CONSTRUCTION
ANIKET TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .