Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAdmitted-Finance | ₹21.9 L | L1 | Admitted-Finance |
| 2 | L2₹28.3 L+₹6.3 L (28.8%)Admitted-Finance | ₹28.3 L+₹6.3 L (28.8%) | L2 | Admitted-Finance |
| 3 | L3₹31.4 L+₹9.4 L (43.0%)Admitted-Finance | ₹31.4 L+₹9.4 L (43.0%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DOON INFRAPOWER PROJECTS PVT LTD L2 | RUDRA ELECTRICALS L1 | shree shyam electricals and suppliers L3 |
|---|---|---|---|---|---|---|
| 0.00Item Rate | ||||||
| 1.00 | Dismantling & disposal of existing old internal manufacturing defective solar PV Module complete Job. | 126 | Each | 118 ₹14,868 Lowest | 300 ₹37,800 | 1,309 ₹1,64,934 |
| 2.00 | Supply, installation testing and commissioning Solar Photovoltaic module in existing solar plant SPV module should be MNRE approved and ALMM listed monocrstyline, SPV module of capacity 580 Wp or above, Anodized Aluminium Alloy Framed Topcon, half cut, N- type Bifacial, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. , 2 mm Low Iron ARC semi-tempered glass, IP-68 PPL Junction box, 4.0 sq.mm cable with MC4 solar connector Make:- Adani/ Waaree /TATA | 106 | Each | 21,513 ₹22,80,378 | 17,500 ₹18,55,000 Lowest | 20,500 ₹21,73,000 |
| 3.00 | SITC of Inverter / PCU : MPPT integrated, IGBT/MOSFET based and microprocessor/ DSP controlled Power Conditioning Unit (PCU) of AC nominal power output rating equal or greater than the required KWp of the module in IP-65 Enclosure, of 250-1500 V DC Input voltage range and 400 V AC, TPN, 50Hz +/- 2.5 Hz, Efficiency > 97%, THD < 3%, Overloading capacity > / = 10%, remote monitoring facility and PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency 25 KW invertor integration with 40 KW existing invertor system with latest generation monitoring technology make must be - K-Solare Inverter to synchronize the existing K-Solare Invertor. | 1 | Each | 1,08,000 ₹1,08,000 | 1,50,000 ₹1,50,000 | 1,05,000 ₹1,05,000 Lowest |
| 4.00 | Array Junction Box / DCDB : IP 65 AJB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. DC fuses with SPD type-II/MOV type surge arrester to be provided. | 1 | Each | 7,080 ₹7,080 Lowest | 11,000 ₹11,000 | 19,500 ₹19,500 |
| 5.00 | ACDB : IP 65 ACDB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. MCB/MCCB with SPD type-II/MOV type surge arrester to be provided. | 1 | Each | 11,092 ₹11,092 Lowest | 18,000 ₹18,000 | 35,000 ₹35,000 |
| 6.00 | Supply Installation Testing and Commissioning of Modification/ rectification/ Refebrication in existing module mounting structure of galvanized sturcture as required. All bolts, nuts, fastners shall be hot dipped galvanized. Modification, designed and installed to withstand the speed for the wind zone of the location. Checking and correction if any for earthing and lightening arrestor as per safty standard and other miscellenous, safety materials, electrical accessories, integration works complete job. | 2 | Each | 2,00,000 ₹4,00,000 | 35,000 ₹70,000 Lowest | 2,65,000 ₹5,30,000 |
| 7.00 | Laying of DC arrey cables to PCU/ DC DB unit, 4 Sqmm armoured copper cable alongwith supplying and fixing of necessary GI raceways/ MS conduit, Lugs and suitable size armoured cable from AC DB to electrical panel complete job Make:- Polycab/ KEI/Finolex/ Havell's | 1 | Each | 5,000 ₹5,000 Lowest | 52,000 ₹52,000 | 1,10,000 ₹1,10,000 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Jul 2026, 11:00 amClosed
SE (CIVIL) AVVNL AJMER
O/O SE (CIVIL), HATHI BHATA POWER HOUSE , AVVNL , AJMER
Upgradation of solar system from 35 KW to 65 KW at Vidyut Bhawan Ajmer
2026_AVVNL_572080_1
AVV2627WSOB00089
Open Tender
Solar Power Plants
Item Rate
60 days
SE Civil, HATHI BHATA POWER HOUSE
PLEASE REFER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹59
AO O and M AVVNL AJMER and MD RISL JAIPUR
₹40,000
Yes
29 Jul 2026
30 Jun 2026
23 Jul 2026
30 Jun 2026
22 Jul 2026
30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Item Rate | - | - | - | - |
| 1 | Dismantling & disposal of existing old internal manufacturing defective solar PV Module complete Job. | 126 | Each | - | - |
| 2 | Supply, installation testing and commissioning Solar Photovoltaic module in existing solar plant SPV module should be MNRE approved and ALMM listed monocrstyline, SPV module of capacity 580 Wp or above, Anodized Aluminium Alloy Framed Topcon, half cut, N- type Bifacial, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. , 2 mm Low Iron ARC semi-tempered glass, IP-68 PPL Junction box, 4.0 sq.mm cable with MC4 solar connector Make:- Adani/ Waaree /TATA | 106 | Each | - | - |
| 3 | SITC of Inverter / PCU : MPPT integrated, IGBT/MOSFET based and microprocessor/ DSP controlled Power Conditioning Unit (PCU) of AC nominal power output rating equal or greater than the required KWp of the module in IP-65 Enclosure, of 250-1500 V DC Input voltage range and 400 V AC, TPN, 50Hz +/- 2.5 Hz, Efficiency > 97%, THD < 3%, Overloading capacity > / = 10%, remote monitoring facility and PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency 25 KW invertor integration with 40 KW existing invertor system with latest generation monitoring technology make must be - K-Solare Inverter to synchronize the existing K-Solare Invertor. | 1 | Each | - | - |
| 4 | Array Junction Box / DCDB : IP 65 AJB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. DC fuses with SPD type-II/MOV type surge arrester to be provided. | 1 | Each | - | - |
| 5 | ACDB : IP 65 ACDB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. MCB/MCCB with SPD type-II/MOV type surge arrester to be provided. | 1 | Each | - | - |
| 6 | Supply Installation Testing and Commissioning of Modification/ rectification/ Refebrication in existing module mounting structure of galvanized sturcture as required. All bolts, nuts, fastners shall be hot dipped galvanized. Modification, designed and installed to withstand the speed for the wind zone of the location. Checking and correction if any for earthing and lightening arrestor as per safty standard and other miscellenous, safety materials, electrical accessories, integration works complete job. | 2 | Each | - | - |
| 7 | Laying of DC arrey cables to PCU/ DC DB unit, 4 Sqmm armoured copper cable alongwith supplying and fixing of necessary GI raceways/ MS conduit, Lugs and suitable size armoured cable from AC DB to electrical panel complete job Make:- Polycab/ KEI/Finolex/ Havell's | 1 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.79 MB
TDUpgradationSolar.pdf
Tender Documents • 8.30 MB
BOQ_1017888.xls
BOQ • 0.28 MB
NIB05C01.pdf
PDF • 1.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .