Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC RAWALPORA WANABAL PATI YAYIL POST OFFICE SANAT NAGAR SRINAGAR 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹7.2 L+₹1.2 L (19.2%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹7.8 L+₹1.7 L (28.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1. |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
22 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN-914134 c/O 56 apo
REPAIR/ MAINT OF HT DISTRIBUTION SYSTEM AND ALLIED WORKS AT KHANABAL GRN UNDER GE 861 EWS
2023_MES_605535_1
134WE-15(T) OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UNDER GE 861 EWS
As per tender documents.
9 documents required · 9 mandatory
₹500
GE 861 EWS
₹20,000
Yes
11 Aug 2023
24 Jun 2023
24 Jul 2023
24 Jun 2023
22 Jul 2023
10 Jul 2023
26 Jun 2023 - 1 Jul 2023
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 mtr deep, for laying cables/ pipes/ poles/stay etc and getting out in any type of soil, complete all as specified and directed.
Excavation in trenches beyond 1.5m and not exceeding 3 mtr deep for laying cables/ pipes/ poles/ stay etc and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removing surplus material (soil) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
Supply and laying reinforced precast concrete cable cover, class HVP, type 2 with peak, flat of size 450mm x 180mm x 40mm, complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation of pole/ stay and mass concrete, complete all specified and directed.
M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in coping etc, rounded and chamfered on edges including necessary form work, complete all specified and directed.
Dismantling and taking out steel pole of any size, fixed in any position and removal from site, complete all as specified and directed.
Supply, fixing and erection in vertical position steel tubular swaged poles type 410, SP-55 (11 metres long) with 300mm x 300mm x 6mm thick mild steel base plate continuously welded to pole, MS plate 3mm thick finial taper plug bolt, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded position and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on remaining exposed surfaces and making alternate black and white strips 30cm high with super enameled paint upto 1.5 mtrs height from ground level/ coping after erecting, complete all as specified and directed. Note : Earth work, PCC shall be measured and paid separately under relevant items of this BOQ.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), of size 3 core 95 Sqmm, laid in trenches / floor / duct throgh GI pipe, complete all as specified and directed.
S&F in replacement galvanised strip of size 25mm x 4mm, burried in ground upto 50cm depth or fixed to wall with insulators etc for loop earthing including welding for joints, complete all as specified and directed. Note:- Earth work will be measured and paid seperately under relevent items.
S&F in replacement GOD triple pole, 11000 volts, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level, for current rating upto 200 Amps with drop out fuse, complete all as specified and directed.
S&F in replacement disc type insulator, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11 KV volts including taking down old unserviceable one, complete all as specified and directed.
S&F in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed.
S&F in replacement danger notice plate of size 25 x 20cm for HT, made out of 1.6mm thick mild steel sheet, vitreous, enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25 x 3mm MS flat fixed with iron, bolts and nuts, complete all as specified and directed.
Supply and laying 20mm graded coarse stone aggregate all around of the HT poles/ feeder panel/ station etc of bed 45cm thick, complete all as specified and directed by Engr-in-Charge.
S&F in replacement lighting arresters expulsion type complete with all fittings, suitable for 11 KV volts and discharge capacity 65 Kilo Amps, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the Galvanised iron strip of size 25mm x 4mm by means of bolts, nuts, check nuts and washers, protected by GI tube light grade of 40mm bore including provision of concrete pit in PCC 1:2:4 type B-1 with 40mm thick cover of RCC (1:2:4) reinforced with XPM, weight not less than 4 Kg /Sqm and 6mm dia round bar handle, excavation and earth work in any type of soil, charcoal dust and salt, 20mm bore GI watering pipe of light grade with funnel and wire mesh, complete all as shown in electrical plate No 3 of MES SSR Part-I (2009) and all as directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metre shall be deemed to include in the quoted rate. (ii) On testing after completion if desired resistance is not obtained, the contractor shall redone the earthing without any extra cost to the department.
Disconnecting HT/ LT side electrical connection carefully existing 11 KV/ 440 Volts stepdown transformer of any capacity, draining out of existing transformer oil after filtration, dehydration and measuring the die-electric strength not less than 40 KV at 2mm gap including reinstallation of transformer satisfactory on its original position, connecting, testing and commissioning, complete all as specified and directed.
Supply and filling in with new transformer oil, low viscosity of approved make as per IS-335 of 1993 and die-electric strength 30 KV when tested at 4mm gap, complete all as specified and directed. Note:- Contractor shall submit the certificate of desire value of die-electric strength from IS approved lab.
S&F in replacement breather assembly CI body of standard size, filled with silica gel of transformer up to 200 KVA capacity, complete with nuts, bolts and washers, complete all as specified and directed.
M&L for strip opening of transformer and removing the top cover for inspection, draining the transformer oil and taking out the core along with HT/ LT coil (Winding) assembling the core after replacement of HT/LT coils heating varnishing, testing and housing accessories in transformer body and connection up filling in dehydrated new transformer oil and connection with existing electrical system HT/ LT and commissioning compete on load of capacity not exceeding 200 KVA including taking down and refixing, complete all as specified and directed. Note :- (i) Transformer oil will be measured and paid separately under respective item of this BOQ
M&L for winding of HT/ LT coil of different type, capacity and make of transformer with approved quality super enameled copper wire of approved make of suitable gauge and number of turns along with allied materials like cork steel, fiber glass insulations, paper insulations, cotton/ empire tap and tube wooden blocks bolts, nuts and washer (brass) soldering and other packing material etc, complete all as required at site and directed.
S&F in replacement HT bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal, suitable for transformer of capacity upto 200 KVA, complete all as specified and directed.
S&F in replacement LT bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal for indoor/outdoor transformer of capacity not exceeding 200 KVA, complete all as specified and directed.
S&F in replacement top gasket, made of 3mm thick cork sheet with suitable holes including providing suitable size of bolts, nuts and washer for transformer top cover complete for any transformer of capacity upto 200 KVA, complete all as specified and directed.
Notes :- An amount of Rs. 52,382.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
VEDA INFRASTRUCTURE
M/S AK ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .