Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC S 5 POST OFFICE BUILDING BATWARA SRINAGAR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹21.5 L+₹27,321 (1.29%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹21.9 L+₹66,638.40 (3.14%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹23.7 L+₹2.5 L (11.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹26.4 L+₹5.2 L (24.3%)Rejected-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L5 | Rejected-Finance Other than lowest bid |
Tender Value
₹19.4 L
EMD Value
₹38,820
Closing Date
26 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN -914134 c/o 56 APO
PROVN OF 200 KVA TRANSFORMER FOR PROJECT NETWORK FOR SPECTURM (NFS) AT COMMUNICATION COMPLEX AT OAF UNDER GE 970 EWS
2022_MES_508505_3
134 WE-70(T)/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Srinagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 970 EWS
₹38,820
Yes
14 May 2022
7 Apr 2022
28 Apr 2022
7 Apr 2022
26 Apr 2022
14 Apr 2022
7 Apr 2022 - 12 Apr 2022
60 days
Amount
Supply, Installation, Testing and Commisioning of copper wound step down outdoor type transformer, 11KV/415 Volts (At No load) AC 3 Phase 50 Hz 200 KVA capacity level-II core type double copper wound oil immersed, naturally cooled, oil natural, air natural (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN, 11 with neutral brought out on secondary side (LV) side and having taping at +2.5% and +5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temprature rise should not exceed 45 degree C in oil and 55 degree C in HV/ LV winding when measured by resistance method after continuous full load run on an abient temp of 40 degree C. The transformer shall be IS-1180, level-2 marked and shall comprise of the following :-
(a) Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods nuts and washers. (b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers with cable glands suitable for reception/ taking out of 03 Nos single core 185 Sqmm and one No. single core 95 Sqmm, LT 1100 Volts grade XLPE insulated and sheathed, heavy duty armoured cable including joints and jointing materials complete. (c) Oil conservator with filter type drain valve and oil level gauge. (d) De-hydrating breather with first fill of dehydertaing agent (silica gel) (e) Explasive vent, thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting lugs, oil filling holes with cap/ plugs with connection plate complete, air release valve plug and four Nos plain solid vest steel detatchable rollers. (f) One No. 100mm dia, dial type thermometer, vapour type pressure having range 0-120 degree C with metal guard having maximum perimeter temp reducing indicator with re-setting device. (g) Two earthing terminals on tank cover to faciliate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal plate. (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (k) First filling of new and unused transformer oil, IS-335 marked filtered and tested upto 50 KV dielectric strength at 2.5mm air gap between testing electrodes. (l) Platform of the transformer with PCC 1:4:8 type D-2 (using40mm graded crushed stone aggregates) with rendring 15mm thick on exposed surfaces and size not less than 2.5m x 2.5m x 0.90m. Note : Precommissioning test shall be carried out by rep of Accepting Officer or by SEI from HQ CENC within overall cost quoted.
Supply, Installation, Testing and Commissioning of automatic Power Factor Correction (APFC) Panel for 100 KVAR for 3 phase, 415 Volts & 50 Hz system with MDXL capacitor 5 steps (50 + 25 + 15 + 5 + 5) including MCCB 4 pole 350 Amps, 50 Hz, 415 V adjustable type with rupturing capacity 36 KA as incommer, complete all as specified and directed.
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) for 2 pole structure consisting of PCC foundation, anti climbing device and cross arms etc, complete all as specified and directed by Engr-in-Charge.
M&L for ACSR conductor of any size on HT poles including binding wire of appropriate size, complete all as specified and directed.
Supply and Installation of triple pole, mechanically operated, outdoor type gang operated air break switch mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 400 Amps 11000 Volts, complete all as specified and directed.
Supply and Installation of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
S&F disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working pressure of size 145mm height, 255mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F pin type porcelain vitreous,brown of white insulator suitable for 11 KV HT of working pressure of size 150mm height, 150mm dia including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F lightening arrestor expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amps, suitable for 11000 volts (11KV) confirming to IS -3070, complete all as required at site or as directed by Engr-in-Charge.
Supply, Laying & Testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (HD) with standard aluminium conductor, 11000 volts grade of 3 core 95 Sqmm, complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in hard/dense soil for laying of cable, errection of pole, stays etc, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and exc 1.5 mtr but not exc 3 mtr deep for pole foundation etc, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the ground level, compalete all as specified and directed by Engineer-in-Charge.
M&L for river fine sand as in cushioning to underground cables with a layer of 8cm thick before laying the cable and 15cm thick after laying the cable, complete all as specified and directed by Engr-in-Charge.
Supply and Laying un-reinforced precast concrete cable cover, class HVP, type-1 with peak, size 300mm x 180mm x 40mm, laid with width along the length of cable on sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for sub class 'B' brick as in covering protection to the eletric cable, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation of poles etc, complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in coping of pole including necessary form work, complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in filling and mass concrete of pole, cutting of road, complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 4 Pole, 350 Amps, 50 Hz, 415 Volts adjustable type with repturing capacity 36 KA, complete all as specified and directed.
Supply, Laying & Testing XLPE insulated, screened, PVC sheathed armoured, heavy duty electric cable with standard aluminium conductor, 1100 volts grade of 3.5 core 185 Sqmm, complete all as specified and directed.
S&F cable jointing kit for 11KV (Earthed) grade cable for outdoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia as earth lead upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3, connected to earthing test point all as specified or indicated including testing on completion including earth work and excavation in any type of soil, PCC 1:3:6 type C-1 chamber, precast slab 40mm thick in cement concrete 1:2:4 type B-1 with 8mm dia MS bars reinforced at 10cm centre to centre both ways including funnel with 20mm bore medium frade GI watering pipe, 15mm bore light grade GI pipe, wire mesh and lugs, including testing on completion, complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized earth lead GI strips of size 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron protected by GI pipe and watering pipe GI 20mm bore, medium grade, connected to earthing test point all as specified or indicated including earth work in any type of soil, charcoal dust, common salt, wire mesh, funnel, PCC pit 1:2:4 type B-1 and 40mm thick cover of RCC (1:2:4) type B-0 reinforced with XPM of weight not less than 4 Kg/Sqm and with 6mm dia MS bar handle made to shape, 40mm bore protection pipe light grade upto 7.5 mtr length & salt etc, complete all as shown in electrical plate No. 5 and testing on completion, complete all as specified and directed by Engr-in-Charge.
Supply and lying tubes, 'light grade', galvanised, with all clamps and all other fitting including nuts and bolts in order to fix it in poles of size 80mm bore, complete all as specified and directed.
Supply, Installation, Testing & Commissioning weather and vermin proof LT feeder pillar box, factory fabricated outdoor cubicle/ kiosk type, CPRI approved and confirming to IS-5036 totally enclosed made out of 3.15mm thick sheet metal enclosure with angle iron frame of MS angle 40x40x6mm, suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system with hinged panel centre opening fornt and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required numbers of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of size not less than 4 Sqmm, duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour including mounting the panel board on ground with PCC 1:3:6 bedding upto a height of 50cm above ground level. Panel should comprise of the following :-
CHINAR CONSTRUCTION TRADERS
M/S YATTOO CONTRACTORS
M/S ZAHOOR ENTERPRISES
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .