CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
PROVN OF FIRE HYDRANT WITH ASSOCIATED FACILITIES AT SRE COMPLEX AT AF STN THANJAVUR
2021_MES_429479_1
CWE(AF)/TVM/TAN/82350
Open Tender
Civil Works
Lump-sum
270 days
Thanjavur
As per NIT
7 documents required · 7 mandatory
₹1,000
GE AF Thanjavur
₹2.0 L
Yes
4 Aug 2021
10 Mar 2021
19 Jun 2021
10 Mar 2021
17 Jun 2021
3 Jun 2021
10 Mar 2021 - 17 Mar 2021
Amount
Lump sum price worked out by the contractor for “BUILDING WORKS ” as listed in Sch ‘A’ Part I representing **___________%____________________________ only) *above / below the lump sum price of Rs 1650000.00 inserted by MES for Schedule ‘A’ Part I .
Lump sum price worked out by the contractor for “INTERNAL ELECTRIFICATION ” as listed in Sch ‘A’ Part II representing **___________%____________________________ only) *above / below the lump sum price of Rs 15106.10 inserted by MES for Schedule ‘A’ Part II .
Lump sum price worked out by the contractor for “(AREA DRAINAGE) ” as listed in Sch ‘A’ Part III representing **___________%____________________________ only) *above / below the lump sum price of Rs 62127.03 inserted by MES for Schedule ‘A’ Part III .
Lump sum price worked out by the contractor for “FIRE FIGHTING / SPRINKLER SYSTEM ” as listed in Sch ‘A’ Part IV representing **___________%____________________________ only) *above / below the lump sum price of Rs 1519876.54 inserted by MES for Schedule ‘A’ Part IV .
Lump sum price worked out by the contractor for “SITE CLEARENCE AND EARTH WORK ” as listed in Sch ‘A’ Part V representing **___________%____________________________ only) *above / below the lump sum price of Rs 21410.54 inserted by MES for Schedule ‘A’ Part V .
Sch 'A' Part- VI - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
Supply and fix Foot Valve conforming to IS 4038,1986, Cast Iron body with leather flap sealing clamped on cast iron disc plates of size 150 mm (6”) dia complete all as specified and directed.
S&F Installation of sprinkler valve set (Assembled set) comprising of following (ISI) UL listed items as under:- (i) Stop valve -01 (ii) Alarm valve - 01 (iii) Pressure gauges - 02 (iv) Test valve - 01 (v) Drain valve - 01 (vi) Alarm Gong (Water operated motor) - 01 Location: except Antenna room, Radar eqpt room, PS room, Room No.1 on first floor and Transformer room
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia all as specified and directed.
Masonary valve chamber internal size 75cmx75cmx75cm including 100mm thick PCC (1:4:8) type foundation, Brick work in CM (1:4), plastering internal surfaces completely and external surfaces upto 150mm below ground level, 15mm thick in CM (1:4) 100mm thick PCC (1:2:4) type C1 as in coping , fabricating MS cover made out of 40x40x5mm thick angle iron frame ,5mm thick MS plate, hinges, lifting handle. locking arrangements, complete including grouting in coping concrete, painting steel surfaces with two coats of synthetic enamel paint over one coat of zinc chrome primer complete all as specified and directed.
Supply, laying and testing 3.5 core ,95 Sqmm UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor with jointing accessories like suitable size of lugs and glands etc complete all as directed. Note: Qty of excavation and earthwork and removal of excavated soil shall be measured and paid under Schedule A Part VI
Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note :- (i) Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning.
AUTO SPRINKLER SYSTEM BASED ON CLEAN AGENT LIKE PER-FLUORO-ETHANE/PENTA-FLUORO-ETHANE/HEPTA-FLUORO-PROPANE Supply , Installation , Testing and commissioning of Auto sprinkler system based on any of the clean agent like per-fluoro-ethane,penta-fluoro-ethane or hepta-fluoro-propane including fire alarm of following parameters as per customer requirements: 1. FAS SERIES A-5000 - UL LISTED AEROSOL UNIT -10 Nos 2. FAS SERIES A-1000 - UL LISTED AEROSOL UNIT- 06 Nos 3.FAS SERIES A-500 - UL LISTED AEROSOL UNIT - 01 No 4. FAS SERIES A-200 - UL LISTED AEROSOL UNIT - 01 No 5. CONVENTIONAL 2ZONE UL LISTED GAS RELEASE PANEL WITH BATTARY BACK UP -04 Nos 6. WEATHER PROOF HORN STROBE -01 No 7. HORN STROBE -03Nos 8. PHOTO ELECTRIC SMOKE DETECTOR WITH FLASHING LED -07 Nos 9. HEAT DETECTOR WITH FLASHING LED - 07 Nos 10. 5AMPS POWER SUPPLY PANEL WITH BATTARY BACK UP -04 Nos 11. WARNING GAS RELEASE SIGNAGE - 04 Nos 12. MANUAL ABORT SWITCH - 04 Nos
13. MANUAL RELEASE SWITCH -04 Nos 14. MANUAL CALL POINT - 03 Nos 15. MANUAL CALL POINT SUITABLE FOR OUTDOOR INSTALLATION -01 No 16. FRLS CABLE 2CORE X 1.5MM2 - 450 RM 17. SEQUENTIAL ACTIVATOR - 18 Nos 18. SYSTEM & COMPONENTS INSTALLATION, COMMISSIONING & INTEGRATION ALONGWITH PANEL TESTING & HANDOVE OF SYSTEM - 04 Nos 19. Other accessories/Powder coating charges/transport charges - 1 Job Note:- i) Architectural drawings of each rooms of SRE bldg with dimensions are attached as Appx'H' (Sl page Nos. 189 to 195) ii) Class of hazard of automatic water sprinkler system is to be designed for low hazard occupancy as per IS-15105 (iii) Exact purpose of room & man power occupancy in each room is attached as 'Appx "J" '
Trial bore of 200 mm dia upto 200meter depth below ground level in any kind of soil strata complete all as specified and as directed. .
Development of successful bore well by compressor and removing the fine sand ,rock particles and other dust items etc air compressor of capacity not less than 500 CFM at 150 to 200 PSIG approximate capacity as required on ground till to get clear water complete all as specified and as directed.
Development of trial bore by reaming up to 525 mm for 60 RM from ground level including casing pipe of 200mm dia and thickness 8mm and pea gravel all as specified and directed.
Development of trial bore by reaming Reaming up to 525 mm from depth exceeding 60 RM to 200 meter including slotted casing pipe of 200mm dia and thickness 8mm and pea gravel complete all as directed.
Supply & filling of gravel pack provided in fine aquifiers of suitable size around bore well casing pipe upto ground level as directed.
Yield test for the bore well by continuously pumping for 16 hours to determine safe pumping yield all as specified and directed.
Supply & fixing of MS reducer size not less than 8mm wall thickness screwed both ends and length not less than 400mm including fittings, bail plug assembly 6mm thick suitable for 200mm bore casing pipe internal threaded with strong iron hook screwed and welded to casing pipe, borewell cap made of 8mm thick mild steel sheet suitable for 200mm dia casing pipe, bore hole centering guide made of MS flat ring ribs suitable for 200 mm dia casing pipe, MS housing clamps 105cm long in two halves 100mm wide made out of 12mm thick MS plate ,electric logging and fabrication & supplying of strata sample box overall size 200x750x100mm, made out of 18 to 20mm thick veneered particle board, frame of aluminium angle of size 25x25x2mm having 20 nos partitions of size 1500x100x100mm made with 12mm thick commercial quality plywood and 25x25x2mm aluminium angle bearers with and also including sliding type sheet glass 5mm thick cover with suitable size aluminium channel frame complete all as directed.
S&F flat submersible cable of size 6 sq mm 3 core PVC insulated and sheathed multistranded 1100 V grade copper conductor all as specified and directed.
Supply, install, and commisioning Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm)complete upto 15 WHP inclusive of 40 metre long submersible cable and starter panel with control switches including Amps meter and voltmeter and starter should be suitable for 15WHP phase motor complete all as specified and directed. Note:- (i)Discharge case shall be fitted with suitable adaptor of 65mm nominal bore of 0.6m length threaded at one end and flanged at other end to match with the column pipe duly fitted with 2 nos flat iron supports. The adaptor shall be welded to GI pipe outlet and studded with discharge case. (ii) Column pipe and control cable shall be measured and paid separately under pressure. (iii) The length of submersible cable connected along with motor supplied by manufacturer shall not be measured and paid for separately.
S&L flanged Pipe galvanized `Heavy class' complete including all joining accessories of size 65mm with slots cut in the flanges to accommodate submersible cable (for lowering submersible pump set) including flanged joints at every 10 ft of pipe all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point , Earth PCC earth pit, RCC cover and earth work and protection pipe and watering pipe complete all as specified or indicated including testing on completion.
M & L for Cutting opening in cement concrete walls (any description) for fixing of 100 mm MS pipe and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, and Rendering 10mm thick cement plaster ( 1 : 4 ) on fair faces of brick work or concrete surfaces all as specified and directed.
S & F of Dry Chemical Powder Modular Type Automatic Fire Extinguisher 10 Kg Capacity,Powder Coated MS Body, Fitted With Heat Sensitive Glass Bulb Sprinkler, Pressure Gauge, Filled With BC Or ABC Powder Complete With All Accessories installed above the transformer in transformer room.
S & F heavy duty exhaust fan 300mm sweep, speed 1400 RPM, corrossion less mild steel body of motor, plastic/fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, 230/240 volts single phase complete including making opening of suitable size of wall, grouting bolts and making good the distrubed surfaces and connection with 1.5 sqmm copper conductor flexible wire from ceiling rose to fan complete all as specified and directed.
Supply and fix new energy efficent LED tube lightr 1 x 20 watts 4 feet long CRCA body powder coated white batten type MCL LED type all prewired with LED tube 20 Watt and driver including connection with twin core flexible PVC 0.5 Sqmm complete all as directed.
Supply & fix energy efficient BLDC ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230volts AC 50 Hz, single phase including provision of fixing arrangement , nut and bolt and flexible 3 core of size 1.5 sqmm not less tha 0.5mtr long with all accessories complete all as specified and as directed.
Supply and fix high power LED 20 W die-cast aluminium IP66 PDC Security light luminiare including Fabrication and fixing of building light bracket made of 40 mm dia GI tubing light grade, 1.5 metres long, bent to shape fixed to wall with 50mm x 6mm GI clamps incl two run of 1.5 Sqmm PVC insulated sheathed copper conductor cable from ceiling rose to Security light fittings drawn through wall complete all as specified and as directed. .
Supply & Fix MCB SPN 25Amp, 10 KA repturing capacity, 230 V, 50 Hz AC, complete all as specified and directed.
Supply & Fix MCB SP 6-32Amp, 10 KA repturing capacity, 230 V, 50 Hz AC, complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate not less than 1.5mtrs below ground level connected with galvanized earth lead 4mm dia by means of bolts, nuts, check nuts and washers of galvnaized iron, etc protected by GI Pipe light grade 15mm bore and 20mm dia GI tubing light grade with funnel for watering connceting to test point,, all as shown in electrical plate No 3 of SSR Part -I incl necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, one provn of test point complete all as specified and directed.
Supply,Install and testing Jockey pump horizontal end suction centrifugal type, pump directly coupled with motor with proper coupling guard Confirming to IS- 12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with non over loading power characteristics for frequent start / stop operations for 440 V, 3 phase, 50 Hz 70 m head 180 LPM discharge,operating speed for the pump shall be 2900RPM. Jockey pump motor shall be totally enclosed fan cooled (TEFC), copper wound for class 'B' insulation mounted as per the OEM direction.
Supply,Install and testing Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS - 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V, 3 Phase,50 Hz 70m Head, 2280 LPM discharge, operating speed for the pump shall be 2900RPM. Fire pump motor shall be totally enclosed fan cooled (TEFC),copper wound class 'B' insulated mounted as per the OEM direction.
Supply,Install and testing Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS - 12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V, 3 phase, 50 Hz AC supply 70 m Head. 2280 LPM discharge mounted as per the OEM direction.
Total of Schedule 'A'
BKR Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .