Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.5 L+₹1.2 L (12.4%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.6 L+₹1.3 L (13.9%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance L3 | |
| 4 | L4₹11.9 L+₹2.6 L (28.3%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹12.8 L+₹3.5 L (37.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
28 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KHUMBATHANG
GE KHUMBATHANG
REPAIR MAINT OF INTERNAL WIRING INCLUDING DISTRIBUTION BOARDS SUB MAIN WIRING
2023_MES_599956_1
CA NO. GE/KHU-23/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE KHUMBATHANG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE KHUMBATHANG
₹40,000
6 Jul 2023
31 May 2023
29 Jun 2023
31 May 2023
28 Jun 2023
14 Jun 2023
Amount
Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc complete all as specified and directed by Eng-in-Charge.
Material and labour for point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5 sqmm including necessary termination board 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earthing and connected to common earthing with PVC heavy duty casing caping/PVC conduit ISI marked as rquired at site along with all accessories and making good the disturbed surfaces of wall/ ceiling etc complete all as specified and directed by Eng-in-Charge. for the following : - (Note : Colour coding for point and sub main wiring should be maintained at site. Incase of any deviation necessary recovery will be made as applicable. )
(a) One light point/ one fan point/ Bell Point controlled by one switch
(b) One 3 pin socket outlet, 5 Amp independent
(c) All as per item 4 here - in - before but One 3 pin socket outlet 5Amps on same board with other switches
All as per item No 2 above but for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy duty ISI marked /heavy duty conduit ISI marked as required at site alongwith accessories with 1.5 Sq mm FRLS PVC insulated unsheathed copper conductor cable as earthing wire and connected to common earthcomplete all as specified and directed by Eng-in-Charge.
S & F in repair switch socket combination 15 amp flush type complete all as specified and directed by Eng-in-Charge.
S & F in repair Switch socket combination 5A all complete all as specified and directed by Eng-in-Charge.
S&F in repair switch piano flush type single pole one way 5 amp complete all as specified and directed by Eng-in-Charge.
S&F in repair holder any type for batten fitting incl taking old one complete all as specified and directed by Eng-in-Charge.
S&F in repair electric bell, AC 230Volts single pole complete all as specified and directed by Eng-in-Charge.
S&F in repair bell push flush type single pole one way 5 amp complete all as specified and directed by Eng-in-Charge.
S & F in repair Ceiling rose 3 terminals complete complete all as specified and directed by Eng-in-Charge.
S&F in repair warm white/ white LED light fitting 1X20 watts,220V AC decorative box type with driver,holder including LED tube light connecting up with two/three core flexible copper conductor cable of suitable size from ceiling rose complete. complete all as specified and directed by Eng-in-Charge.
S&F in repair warm white/ white LED luminaire 600X600 mm,35/36 watt,220V recessed type with high efficiency PMMA diffuser soft glare free light complete with driver,holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size.complete all as specified and directed by Eng-in-Charge.
S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surfacecomplete all as specified and directed by Eng-in-Charge. incl taking down old one
S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface incl taking down old one complete all as specified and directed by Eng-in-Charge.
S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed by Eng-in-Charge. incl taking down old one
S&F in replacement sheet metal enclosures distribution boards,double door 4 way three phase 415 volts MCCB,ISOLATOR&MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB 4 Pole 100 AMPS AC 415 V 10 KA=01 NO as incoming & outgoing MCB SP-12 No 40 AMP (Note :- (i)The DB shall be of VTPN series (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(1v) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains daily. complete all as specified and directed by Eng-in-Charge.
S&F in repair MCB single pole,6 to 32 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed by Eng-in-Charge. incl taking down old one
S&F in repair MCB SPN 32/40 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed by Eng-in-Charge. incl taking down old one
S&F in repair MCB SPN 63 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed by Eng-in-Charge. incl taking down old one
Taking down old u/s submain wiring of any sizescomplete all as specified and directed by Eng-in-Charge.
M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 2X6 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with 1X6 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth complete all as specified and directed
M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 2X4 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with 1X4 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth complete all as specified and directed by Eng-in-Charge.
Taking down old u/s undergound cable/service cable of any sizescomplete all as specified and directed by Eng-in-Charge.
Supply and fixing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor cable 1100 volts grade laid in trenches / passing through GI pipe / on pole / on wall of size 16 sq mm 2core complete all as specified and directed by Eng-in-Charge.
Supply and fixing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor cable 1100 volts grade laid in trenches / passing through GI pipe / on pole / on wall of size 10 sq mm 2core complete all as specified and directed by Eng-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in hard soil complete all as specified and directed by Eng-in-Charge. (cable shall be laid 60 cm below ground level )
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil. complete all as specified and directed by Eng-in-Charge.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point. complete all as specified and directed by Eng-in-Charge.
Sand cushioning for cables with hight of cushioning as 8 cm below the cable and 15 cm above the cable complete all as specified and directed by Eng-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-1, flat, size 250mm x 150mm x 40mm complete all as specified and directed by Eng-in-Charge.
Supply and fixing G I tubing 40 mm dia light grade galvanised with all fittting and fixed fix on wall ceiling or laid in floors complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair casing and caping 25mm/PVC heavy duty including all fixing accessories complete all as specified and directed by Eng-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0 mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. complete all as specified and directed by Eng-in-Charge.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor ,served with inner sheathing of PVC tape and overall PVC sheathed in service connections two core of size 6 sq mm flat or circular complete all as specified and directed by Eng-in-Charge.
S&F wall mounted swing 300 mm fan off white , corded electric, size 39.2x45.2x43.2 cm 230 V, 120 ribs guard, pull cord control for speed and oscillation on-off, aerodynamically designed and balanced blades, speed 1330 RPM air delivery 45 cmm powr 45 Watt with 2 years warranty, pull chain control complete all as specified and directed by Eng-in-Charge.
Dedcuct Credit for Demolished/Dismantled material Rs (-) 62635.00 (Minus) as listed in Schedule 'A' Sec-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
Ms Salaria Builders
M/S TRADE LINK
M/s Raj Construction
M/S NISSAR ALI
Top Mind Industries Pvt Limited
KASHMIR FAIR DEAL SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .