Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | ₹29.2 L Quoted ₹29.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹34.4 L+₹4.5 L (15.0%)Rejected-Finance | ₹34.4 L+₹4.5 L (15.0%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹35.6 L+₹5.6 L (18.8%)Rejected-Finance | ₹35.6 L+₹5.6 L (18.8%) | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹35.9 L+₹5.9 L (19.8%)Rejected-Finance | ₹35.9 L+₹5.9 L (19.8%) | L4 | Rejected-Finance Being other than lowest |
| Sl No | Description | Qty | Unit | MANI PRASAD GUPTA L1 | M/S BIJOYA LAXMI ENTERPRISE L4 | L BINOD CONSTRUCTION CO L3 | M/s Nongmaithem Construction L2 |
|---|---|---|---|---|---|---|---|
| 1.00Schedule 'A' | |||||||
| 1.01 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. | 13.81 | Cum | 1,150 ₹15,881.5 | 990 ₹13,671.9 Lowest | 1,299 ₹17,939.19 | 1,000 ₹13,810 |
| 2.00 | M&L for brick work with subclass ‘B’ bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. | 13.66 | Cum | 9,800 ₹1,33,868 Lowest | 13,000 ₹1,77,580 | 11,200 ₹1,52,992 | 10,900 ₹1,48,894 |
| 3.00 | M & L for brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed. | 2.28 | Sqm | 1,600 ₹3,648 | 2,450 ₹5,586 | 1,530 ₹3,488.4 Lowest | 1,800 ₹4,104 |
| 4.00 | M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed.
Note : (i) WPC will be measured and paid separately
(ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account. | 67.74 | Sqm | 503 ₹34,073.22 Lowest | 655 ₹44,369.7 | 625 ₹42,337.5 | 560 ₹37,934.4 |
| 5.00 | Supply only intergral water proofing compound complete all as specified and directed | 11 | Kg | 63 ₹693 | 54 ₹594 | 61 ₹671 | 50 ₹550 Lowest |
| 6.00 | M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed. | 46.79 | Sqm | 483 ₹22,599.57 Lowest | 620 ₹29,009.8 | 570 ₹26,670.3 | 550 ₹25,734.5 |
| 7.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness below or above ground floors complete all as specified and as directed. | 6.86 | Cum | 1,245 ₹8,540.7 Lowest | 2,600 ₹17,836 | 1,550 ₹10,633 | 2,100 ₹14,406 |
| 8.00 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work.complete all as specified and directed. | 1.16 | Cum | 1,745 ₹2,024.2 | 1,800 ₹2,088 | 2,500 ₹2,900 | 1,500 ₹1,740 Lowest |
| 9.00 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand) | 75.48 | Sqm | 675 ₹50,949 | 650 ₹49,062 | 720 ₹54,345.6 | 600 ₹45,288 Lowest |
Tender Value
₹29.2 L
EMD Value
₹58,400
Closing Date
25 Feb 2026, 6:00 pmClosed
GE 869 EWS
GE 869 EWS Pin 913869
PROVN OF COVER SHED OF BOI IN HQ 57, SPECIAL REPAIR/ALTN TO BLDG NO. T-923, ADDN/ALTN TO BLDG NO T- 904 AND ADDN/ALTN TO BLDG NO T-239 AT LMS UNDER GE 869 EWS
2026_MES_751716_1
8721/E8
Open Tender
Civil Works
Item Rate
210 days
LEIMAKHONG MIL STN
As per tender document
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹58,400
Yes
5 May 2026
6 Feb 2026
26 Feb 2026
6 Feb 2026
25 Feb 2026
19 Feb 2026
Schedule 'A'
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed.
M&L for brick work with subclass ‘B’ bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed.
M & L for brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed. Note : (i) WPC will be measured and paid separately (ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account.
Supply only intergral water proofing compound complete all as specified and directed
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness below or above ground floors complete all as specified and as directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work.complete all as specified and directed.
M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand)
M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed.
M&L for glass dividing strips 3mm thick and width of strip 38mm complete all as specified and directed.
M&L for 50mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate as in sub base complete all as specified and as directed by the Engineer-in-Charge
M&L for RCC 1:2:4 (nominal mix) type B1 (using 20mm graded stone aggregates) as in beams, cantilevers, bressumers, lintels over 1.5 m span etc complete all as specified and directed by Engr-In-Charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finised surface of concrete complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto as per items No 61.00 here-in-above but 5mm and over upto & incl 10mm dia in stirrups, spaces and binders complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store & rubish of the permises complete all as specified and directed.
M&L for Glazed Coloured Ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick set and joint in neat cement slury and pointed in white or colour cement to match over and including 10mm thick plaster in CM 1:4 as backing coat to receive tiles complete all as specified and directed.
M&L for Non -skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade and includig 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in dado, skirting, wall tiling etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including rendering 10 mm thick on fair faces of brick work in CM (1:4) for receiving vertical dado, skirting, wall tiling etc. complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including screed bed 20mm thick in CM 1:3 complete all as specified and directed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing , nosing & grooming on steps, including screed bed 20mm thick in CM 1:3 complete all as specified and directed.complete all as directed.
Dismantling of plain/ corrugated including Nainital or similar pattern mild steel sheeting of any gauge, thickness roof coverings and segregating serviceable sheet and stacking for reuse and removing unserviceable materials from site of work complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 0.63mm thick, plain galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
S&F 0.60mm thick, plain galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
M&L for preparation of new zinc (or galvanised) surfaces to receive painting by coating with mordant solution including washing and cleaning etc and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. Note :-Dismantling of false ceiling to be carried out carefully without damaging existing fitting and fixtures of flase ceiling items
S&F silhousette false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 20 x20 x0.35mm and main/cross tee of size 24 x38 x0.35mm with 4mm dia GI wire as suspender and including dew drop PVC Tile 595X595X8 mm complete all as specified and directed.
S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 22 x22 x0.35mm and main/cross tee of size 24 x38 x0.35mm with 4mm dia GI wire as suspender and including 4mm thick Plain E-Board including fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed.
M & L for 4mm thick plywood, grade BWR, type BB fixed with nails or screws to timber frame work complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of oil emulsion distemper over one coat of cement primer and putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat primer complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc. 4 sqm each complete all as specified and directed..
Taking down shutters of any description exc 1 sqm and not exc 2 sqm each including easing and adjusting and also refixing builder hardware as required including renewal of unserviceable screw and necessarry materials refixing shutter in same opening complete all as specifeid and directed.
S&F Aluminium powder coated frame/chowkats for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed.
M&L for Anodised aluminium sliding window, 3 track system and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. including all fitting complete all as specified and directed.
M&L for 4.8mm thick plain tinted sheet glass ordinary quality in squares exc 0.5 Sqm each pane for aluminium window, complete all as specified and directed.
M&L for 4.8mm thick plain tinted sheet glass ordinary quality in squares not exc 0.5 Sqm each pane for aluminium window, complete all as specified and directed.
S&F 12mm thick toughened glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required including all required accessories complete all as specified and directed.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directected .
M&L 2nd class hard wood plain, solid, straight chowkhats and frames, wrought framed rebated on the solid, rounded or chamfered put together with glue, pinned at joints complete all as specified and directed.
S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F 100mm long Mortice latch with two levers (vertical type), brass body and fixed complete all as specified and as directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 100mm stainless steel butt hinges medium weight complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed.
S&F 75mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 150 mild steel barrel tower blots, stove enamelled black, with bright bolt and fixed and fixedsection barrel tower bolts complete all as specified and directed.
S&F 100mm long mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
S&F Mild steel sliding door bolts 300 mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed and fixed 300mm long complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated wood surfaces of any description not other wise described over 10 cm with or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint including preparation of old decorated wood surfaces of any description not otherwise described over 10 cm with or girth complete all as specified and directed.
S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with 150mm overall length of cover plate complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sucnk) forming holes with any attachement Fe 410W (Gde-E-250) complete all as specified and directed.
S&F Structural steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Grade E-250) quality-A complete all as specified and as directed.
S&F steel work in tubular or square trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A) complete all as specified and as directed.
M&L for structural steel work in Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Grade E-250) quality-A complete all as specified and as directed.
M&L for Tie bars with screwed ends,nuts, washers and mild steel plates for walls, chimneys, roofs,arches, etc. king rods and straining bolts conforming to Fe 290 Gde-E-165 complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling of framed timper scantling 40 sq .cm and over in any section,in any position complete all as specified and directed.
M&L for second class clean sawn hard wood in scantling wrought, timber framed & fixed complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with complete all as specified and directed.
S&F in repairs 18 mm thick medium density fibre board, exterior grade, fixed to timber framework with screws complete all as specified and directed.
S&F in repair vitreous china European type wash down water closet pan (Pedestal pattern) of white colour including plastic water closet seat cover closed pattern with flat bottom (with MS or CP hinging device) and fixing bolts, P or S trap, necessary inlet and outlet connections including syphonic action type low level PVC flushing cistern of 10 ltr capacity in colour and PVC flush pipe 32mm dia complete all as specified and directed.
S&F in repair over head shower 114X114 mm single flow (ABS body CP) with rubit cleaning system complete all as specified and directed. Make-ESSCO-CHR-442
S&F in repair Thin Rim table top wash hand basin with fixing accessories complete all as specified and directed. Make-Jaguar Cat Part No -JDS -WHT-25911
S&F in repair Angular Stop Cock with Wall Flange complete all as specified and as directed. Make-Jaguar Cat Part No-FLR-5053N
S&F in repair Waste coupling 32mm Size Full Thread with 80mm height complete all as specified and directed. Make-Royal
S&F in repair Bottle Trap 32mm Size with 250mm & 190mm Long Wall Connection Pipes & Wall Flange complete all as specified and directed. Make-Jaguar Cat Part No-ALD-769L300x190
S&F in repair Towel rail 450mm long complete all as specified and as directed.Make-ESSCO
S&F in repair corner glass self with bracket (225X225mm) complete all as specified and directed. Make-Jaguar
S&F in repair Soap dish complete all as specified and directed. Make-ESSCO Cat Part No-AEC-CHR-1131N
S&F in repairs Single Lever Basin Mixer with Popup Waste System with 450mm Long Braided Hoses for mixing hot and cold water complete all as specified and as directed. Make-Jaguar Cat Part No-FLR-CHR-5001B
S&F in repair Towel rack chromium plated brass of size not less 60cm long complete all as specified and as directed. Make-Royal
S&F in repair wall mixture 3 - in -1 System for mixing hot and cold water and fixed for 15 mm bore dia pipe complete all as specified and as directed. Make-Jaguar Cat Part No-FLP-CHR-5281PM
S&F in repair two in one Bib Cock with Wall Flange complete all as specified and as directed. Make-Jaguar Cat Part No-85041
S&F in repair hand shower (health faucet) ABS Body with 8mm dia 1.0 m long flexible tube & wall Hook complete all as specified and as directed. Make-ESSCO Cat Part No-ALE-CHR-593
S&F in repair hand shower pack (single flow 80mm dia round shape hand shower with 1.50M long spirochrome flex hose and wall bracket complete all as specified and as directed. Make-ESSCO Cat Part No-SAE-CHR-1929SH555
S&F in repairs fancy type decorative Drapary rod of 20mm dia for window and doors with decorative doom holders fixed to wall with screw complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts and bolt of length 600mm complete all as specified and directed.
S&F in repair Toilet paper Holder fixed to wall with chromium plated brass screws complete all as specified and as directed.
S&F PVC (SWR) floor trap with grating with incl jointing to waste pipe fixed in cement concerete (1:2:4) diameter of outlet pipe 75mm complete all as specified and directed.
Taking up or down 15mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed.
S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in. making good to facings of brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking up or down 20mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed.
S&F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all complete as specified and as directed.
S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floor complete all as specified and as directed.
S&F 75mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floor complete all as specified and as directed.
S&F 160mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floor complete all as specified and as directed.
S & F 160 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S&F in repair PVC (SWR) branch piece single 'T' equal or unequal 110mm dia with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and directed.
M&L for PCC in cement concrete type B-0 ,1:2:4 (using 12.5 mm graded aggregate) as in coping including necessary formwork etc complete all as specified and directed.
M & L for RCC 1:2:4 Type B1 nominal mix (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; basesfor columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. Note :- Reinforcement and form work required shall be measured and paid seperately.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rough finished surface of concrete complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel frame, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S&F sheet glass 3mm thick, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out in soft/loose soil complete all as specified and directed.
M & L for PCC 1:3:6 Type C2 (Nominal mix) (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed.(Note:- using dimapur sand)
Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc complete all as specified and directed.
Material and labour for point wiring concealed type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated 1100 volts grade and unsheathed, multi-stranded, copper conductor single core cable through and including concealed wiring 20 mm pvc rigid conduit with all fixing accessories and suitable including 1.6 mm thick size sunk MS pressed steel modular box including suitable size of white modular frame with cover plate for mounting modular switches,sockets and regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed) (a) One light point controlled by one, one way switch. Note :- (i) The quoted rate shall be deemed to be inclusive mild steel sunken boxes/modular cover plate and cutting chases in brick wall/ pillars etc for concealing the depth and making good the disturbed surfaces in CM 1:4 including finishing the surface to match with the portion of point wiring at for covering/ fix sunken boards/ terminals. (ii) Fiitings like switches, sockets, regulators, lamp holders, light fitting etc shall be measured and paid for separately of concern item of Sch 'A'.
One ceiling/exhaust fan point controlled by one, one way switch
One socket outlet 5 Amps 5 pin on independent board
One socket outlet 5 Amps 3 pin on same board with other switch
All as per item No. 113.00 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand insulator copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
All as per item No. 113.00 here-in-above but with cable size 4 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand insulator copper earth continuity conductor of size 4 Sqmm complete all as specified and directed.
Material and labour for point wiring with steel conduit type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated 1100 volts grade and unsheathed, multi-stranded, copper conductor single core cable through and including concealed wiring 20 mm pvc rigid conduit with all fixing accessories and suitable including 1.6 mm thick size sunk MS pressed steel modular box including suitable size of white modular frame with cover plate for mounting modular switches,sockets and regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed) (a) One light point controlled by one, one way switch. Note :- (i) The quoted rate shall be deemed to be inclusive mild steel sunken boxes/modular cover plate and cutting chases in brick wall/ pillars etc for concealing the depth and making good the disturbed surfaces in CM 1:4 including finishing the surface to match with the portion of point wiring at for covering/ fix sunken boards/ terminals. (ii) Fiitings like switches, sockets, regulators, lamp holders, light fitting etc shall be measured and paid for separately of concern item of Sch 'A'.
One ceiling/exhaust fan point controlled by one, one way switch
One socket outlet 5 Amps 5 pin on independent board
All as per item No. 136.00 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand insulator copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed) One light point controlled by one, one way switch
One ceiling/exhaust fan point controlled by one, one way switch
One socket outlet 5 Amps 5 pin on independent board
One socket outlet 5 Amps 5 pin on same board with other switches
All as per item No. 123.00 here-in-above but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed.
S&F modular switch 6 Amps, single pole, one way complete all as specified and directed.
S&F modular switch 16 Amps, single pole, one way complete all as specified and directed.
S&F modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed.
Supply and fixing modular Switch Socket 6/16 , 2/3 pin combined 2 module complete all as specified and directed.
S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F of 1100 volts grade heavy duty cabled PVC insulated aluminium conductor served with inner sheating of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than one meter apart including 4 mm suspension wire one twin core cable 2 core flat of 10 sqmm size complete all as specified and directed.
M&L in repair for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including Concealed PVC conduit of suitable size with all fittings and fixing accessories ISI marked on roof , wall , ceiling etc. and including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. Note : Two runs of 6.0 sqmm conductor for main and one run of 6.0 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length.
S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed.
S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 4 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed.
S&F in repair MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in repair MCB single pole and neutral 40 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in repair MCB single pole and neutral 40 to 63 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F metal exhaust fan AC single phase 230 volts of size 300mm sweep with louvre complete fixed and opening of wall with suitable MS bolts, grouted to wall and connecting up including provision of cable from connector to fan with flexible cable 24/0.2mm with copper conductor and necessary fitting complete all as specified and directed.
S&F LED light fitting 1x20 Watt , 220 V , AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt, 220V, AC decorative type with driver holder and LED lamp including connecting up with three coat flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of current carrying capacity 20 Amp complete all as specified and directed.
Supply and fixing LED building secuirty light fittings 35 watt 230 V AC out door type with high pressure dia cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F LED flood light 70 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and incl eassy to instl with base plate connection complete all as specified and directed.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 Watt, 220 V AC recessed type white/warm with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connceting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair of Flame Proof/ Weather proof lighting Distribution board SPN 4 Way DB (i) Incoming : MCB, 2P, 16A to 25A - 01 (ii) Outgoing : MCB, 1P, 6A to 10A - 02 Complete internal busbar and wiring up terminals complete all as specified and directed.
Supply and fix LED CIMFR certified LED flame proof batten suitable for twin T8 tube of 18/20W, suitable for Gas/Vapour group of IIA & IIB and Zone 1&2 and IP 65 Protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories and connecting up with twin core twisted flexible copper conductor with suitable size comple all as per specified and directed.
Supply and fixing Flame proof rotary type switch with terminal box in cast aluminium alloy (LM-6) construction ,epoxy powder coated, single pole 16 amps on off type 250 V AC certifed by CRMI for Group II A & II B completed including compression glands all as specified.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed and deposited to MES store yard.
S&F Flame proof/ Weather proof ceiling fan with reglator 48", single phase SSPL/CF/193 - ceiling fan and SSPL/2C/1010 - Regulator
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed. (Note: Earth strip beyond 7.5 m length will be measured & paid separately)
M&L in repair for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth strip of size 32 x 6 mm by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion complete all as specified and as directed. (Note: Earth strip beyond 7.5 m length will be measured & paid separately)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soft/loose soil complete all as specified and as directed.
Removing excavated material/soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.)
Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable complete all as specified and directed.
Supply, laying, Jointing and testing in repair of LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply and fix in repair galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe complete all as specified and directed. NOTE : Excavation & earth work shall be deemed inclusive of in this item.
Supply and fix in repair single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
M&L in repair of earth Test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
BOQ_841919.xls
BOQ • 0.52 MB
Tender.pdf
Tender Documents • 1.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .