Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC JAISALMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹21.1 L+₹11,639.08 (0.55%)Rejected-Finance | L2 | Rejected-Finance Higher amount quoted | |
| 3 | L3₹21.9 L+₹86,460.54 (4.11%)Rejected-Finance | L3 | Rejected-Finance Higher amount quoted | |
| 4 | L4₹22.9 L+₹1.9 L (9.12%)Rejected-Finance | L4 | Rejected-Finance Higher amount quoted |
Tender Value
Refer Docs
EMD Value
₹46,498
Closing Date
19 Aug 2021, 6:00 pmClosed
CWE (A) Jaisalmer
CWE (A) Jaisalmer
SPECIAL REPAIRS TO P-03 AT KHETOLAI, P-13, P-22 AND T-168 AT POKARAN MIL STATION UNDER AGE (I) POKARAN
2021_MES_461759_1
83962
Open Tender
Civil Works
Works
180 days
Pokaran
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (A) Jaisalmer
₹46,498
Yes
2 Feb 2022
22 Jul 2021
21 Aug 2021
22 Jul 2021
19 Aug 2021
5 Aug 2021
Amount
Demolition of PCC in Ground Floor and paving n exc 15 cm (below or above ground level)
Dismantaling Stone slabs and tiles of any description or thickness in floors, aprons etc.
M&L for PCC type D2 1:4:8 using 40mm graded stone aggregate, 75 mm thick as in sub base for floors, complete all as specified and as directed by Engr-in-charge
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-charge
PCC 50 mm thick in type B-1:2:4 using 20 mm graded stone aggregate and top surface concrete should be finished with even and smooth with using extra cement and mechanical power trowel cum floater complete all as specified and as directed by Engr-in-charge
M&L for coloured Glazed ceramic tiles in vertical surfaces 450 x300x7 mm thick on vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm backing coat in CM1:3 including complete all as specified and as directed by Engr-in-charge
S&F for Non- skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with screed bed 15 mm thick CM 1:6 complete all as specified and as directed by Engr-in-charge
M&L Coloured joint free Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchand including screed bed 15 mm thick in CM (1:6) all as specified.
All as per item No.08 here in before, but on vertical surface over a backing coat of 10 mm thick plaster in CM 1:4 completeall as specified and as directed by Engr-in-charge
M&L for vitrified ceramic tiles 10mm thick (square/ rectangular) light shade polished, area of each tiles not exceeding 0.36 Sqm, in floor etc set jointed and pointed in white or coloured cement to match the colour of tiles with screed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6. all as specified.
M&L for vitrified ceramic tiles 10mm thick (square/ rectangular) light shade polished, area of each tiles not exceeding 0.36 Sqm, in vertical surfaces such as skirting etc, set jointed and pointed in white or coloured cement to match with and including backing coat of 10 mm thick in CM 1:4. all as specified & directed.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.and black all as specified and as directed by Engr-in-charge
M&L for Hand Cut Kota stone flooring 20-25mm thick incl for cuttting and polishing by machine over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including provision of 20 mm thick screed bedding in CM (1:6) all as specified and as directed by Engr-in-charge
Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting,dado,and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including provision of 10 mm thick backing coat of CM (1:3) all as specified and as directed by Engr-in-charge
M&L for 5cm sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete complete all as specified and as directed by the Engineer-in-Charge
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations.
Drilling holes for bolts, pipes, etc. n. exc 25mm dia in granite or trape stone for gas connection pipe
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915 mm x 460mm bowl size 410mm x 330mm x 160mm
S&F PVC waste pipe 50 mm dia for sink
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregates) as in plinth protection finished even and smooth all as specified.
Supply only integral Waterproofing compound.
M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltr/Sqm by forced and sealing all the over laps of 75 mm in length side and 100 mm on the width side of membrane including following all as speficied and directed. (i) Complete removal of existing water proofing treatment incl bedding if any n exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed. (ii) M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course for consolidated thickness shall be varied from 25 to 55 mm as per the requirements all as directed by Engr-in-Charge. (iii) M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC (WPC will be measured and paid separately as supply only)
Taking down cement plaster on walls and roof ceilings etc., including racking out joints, hacking for key, scrubbing down with water etc. to receive new plaster
M&L rendering 15mm thick in 1:6 cement plaster on stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L rendering 15mm thick in 1:4 cement plaster on of stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L preparation of new wall surface and applying two coats of distemper oil emulsion over a coat of alkali resistant primer,including 3mm thick wall care putty on wall complete all as specified and directeded.
M&L preparation of new wall surface and applying three coat of white wash on surfaces of ceiling complete all as specified & directed by Engineer-in-charge.
M&L for preparing old painted surfaces and applying a coat of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L for applying two coats of cement base paint over a coat of primer on newly plastered surfaces of walls including preparation of surfaces complete.
Complete preparation new surfaces of walls and preparation of surfaces (external faces) of walls and applying two coats of external weather proof paint of Apex or equivalent over a coat of primer (self coat) complete all as per manufacturers instructions, complete all as per specified and directed.
M&L for preparing old painted surfaces and applying a two coat of oil bond distemper on surfaces of walls over a coat of 3 mm thick wall care putty complete all as specified & directed by Engineer-in-charge.
Taking down door shutter area exc 1 sqm but n exc 2 sqm each and removing to store
Taking down Chowkat or frames with shutters (with out taking off shutters from the frames) area n exc. 1.50 Sqm each and removing to store
Taking down Chowkat or frames with shutters (with out taking off shutters from the frames) area exc 1.50 sqm and n exc 4.00 sqm
S&F for Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), Fe 410-W (Gde E-250) quality A
Second class HW rail and style plain frame factory made moulded panelled shutter 35 mm thick (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered partical board with commercial veeneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated.
M&L for II nd class hard wood Glazed and skeleton shutters, 30 mm thick , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, cla-use 8.20 (a); supplied and fitted to chowkats all as specified and as directed by Engr-in-charge
Prelaminated particle board,interior grade, prelaminated both side 18 /19 mm thick with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work but prelaminated both sides with decorative choice laminations all as specified and as directed by Engr-in-charge
Supply and fix in repairs 18 / 19 mm thick Veneered particle board, fix in cupboard shelves, interior grade, solid core, medium density general purposes type with commercial face veneers type ‘BB’ all as specified and as directed by Engr-in-charge
S&F continuous (piano) hinges, mild steel, bright finish or electro galvanized width of flaps (when open) 30 mm.
S&F Ball catches with 8mm dia steel ball, and bras body and striking plate including letting in and fixed
M & L II nd class hard wood Plain fillets, square, rectangular or triangular in section, clean swan, se-cured with nails or brads, sectional area not exc 3.00 Sqcm.
S & F aluminium anodised Hasp and staple 75mm , safety type, mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F 100 mm long Aluminium anodised barrel tower bolt of extruded section .
Supply and fix Extruded aluminium alloy handles, 100 mm long fabricated type., anodised
Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
M&L for sheet glass 5.5mm thick, ordinary quality and glazing with, rubber packing n exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
M&L for sheet glass 5.5mm thick, ordinary quality and glazing with, rubber packing exc 0.5 sqm in each panel
M&L Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufactures
S&F for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165
S&F Welded steel wire fabric supplied and fixed complete to wood or steel members
M&L for anodised aluminium framed work such as grills with frame, & framed guard bars similar work complete all as specified and as directed.
Supply and fix Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqn in each pane.
S&F 4 mm thick figured glass, pin headed type and glazing with oil putty in square n exc 0.50 sqn in each pane.
S&F Mild steel cold rolled Butt hinges 100 mm medium weight
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed.
S&F Aluminium anodised, barrel tower bolt of extruded section and fix of length 125mm
S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
S&F Aluminium alloy , anodised sliding door bolt 300 mm long with hasp, staple ( Bolt type) and fixing clips of sheet, cast or extruded section or cast aluminium alloy and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.
M&L for double action door spring hydraulically regulated made up of minimum 1.25 mm thick aluminium sheet foundation box ,main body with stainless steel cover, grovering piovt made of brass, other parts made of mild steel heavy duty and fixed.
Preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and direction.
Preparation of new Steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and direction.
Supply and fix rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-I ,1000 ltr capacity inclduing dismantling water tanks and removing to store capacity of tank exc 500 and n exc 1000 ltr) all as specified and directed by Engineer Incharge
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
S&F Medium grade GI tubing 15 mm bore with all fittings , to walls, ceiling or laid in floors etc including taking up or down steel tubing and connections including cleaning for refixing or removal to store 15 mm bore to walls, ceiling etc.
S&F Medium grade GI tubing 20 mm bore with all fittings , to walls, ceiling or laid in floors etc including taking up or down steel tubing and connections including cleaning for refixing or removal to store 20 mm bore to walls, ceiling etc.
S&F gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 15 mm bore pipe.
S&F gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 20 mm bore pipe.
S&F in repairs for stop cock copper alloy but fancy type and chrominum plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron/pipe or for union and fixed 15 mm bore.
S&F in repairs bib taps cast cipper alloy chromoum plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia out let
PVC (SWR) multi floor trap with grating including jointing with solvent cement 100 mm dia out let.
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls
S&F PVC (SWR) pipes of 75 mm dia, single socket fixed to walls
S&F PVC (SWR) bends with access door of 110 mm dia, any radius
S&F PVC(SWR) bends with access door of 75 mm dia, any radius
S&F PVC (SWR) bends of 110 mm dia, any radius
S&F PVC (SWR) bends of 75mm dia, any radius
S&F in repairs Viterious china White Wash Hand Basin of fixed in repairs includign 15 mm pillar cock cast copper alloy CP, 15mm cast copper stop valve, 32 mm brase CP waste fitting, PVC waste pipe 32 mm dia & 15 mm PTMT connection pipe 450 mm long all as specified and as directed by Engr-in-charge
Demolition of stone/ boulder masonry and built in cement mortar all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses all as specified & directed by Engineer-in-Charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) but except stone all as specified & directed by Engineer-in-charge complete.
Demoliton of RCC Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similars all as specified and all as specified and as directed by Engr-in-charge
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates,Fe 410-W (Gde E-250) quality A all as specified and as directed by Engr-in-charge
M&L for jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted, set, jointed and grouted in lime mortar 1:3 or cement mortar 1:6 complete complete all as specified and as directed by the Engineer-in-Charge
Demolition of wall ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified and as directed by Engr-in-charge.
S&F ,10mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium / G.I./M.S. as per specification and drawing, including Anodised aluminium snap grid frame work of size 605 x 605 mm for false ceilingall as specified and all as specified and as directed by Engr-in-charge
S&F for anodised aluminium snap grid 605 x 605 mm frame work for false ceiling all as specified and directed,Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed by Engr-in-charge
M&L for providing and fixing Gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions all as specified and as directed by Engr-in-charge.
Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and as directed by Engr-in-charge
S&F Pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and as directed by Engr-in-charge
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed by Engr-in-charge
Dismantling wrought iron or mild steel work of any description not otherwise provided all as specified and as directed by Engr-in-charge
S&F for MS work confirming to Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 as in post, strut, purlins & wind ties with (MS flat iron fillet, MS plate & angle iron) necessary cutting, drilling, welding, bolting or riveting etc including embeding in concrete complete to any type of posts screwed in position with nuts, bolts & washers, etc all as specified and as directed by Engr-in-charge
S&F 2mm Thick, Fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixe with coach screw and washer in roof, wall etc all as specified and as directed by Engr-in-charge.
Dismantling fencing wire mesh, any type all as specified and as directed by Engr-in-charge
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground ( RCC Post) all as specified and as directed by Engr-in-charge
M/L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors all as specified and as directed by Engr-in-charge.
M&L for Cement concrete type C2 1:3:6 (40mm graded agg) in foundations, filling and mass-concrete all as specified and as directed by Engr-in-charge
Supply and fix mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 all as specified and as directed by Engr-in-charge
M&L for mild steel TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including steel wire (anealed) not less than 0.9mm dia complete all as specified & directed by Engineer-in-Charge.
Supply only chain link MS galvanised fencing of size 50mm x 50mm, 3mm thick all as specified and as directed by Engr-in-charge
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, GI mesh size 50mm x 50mm , 3mm dia all as specified and as directed by Engr-in-charge
Material and labour for one coat of synthetic enemal paint on old steel surfaces of any des-cription, over 10cm in width or grith, not otherwise described all as specified and as directed by Engr-in-charge
Supply only MS screw bolts (Machine made) length of bolt exc 5 cm but not exc 10 cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of shank 5 to 10mm all as specified and as directed by Engr-in-charge
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering. Door, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails & guides) and hanging also fastening & complete all as specified & directed by Engineer-in-charge.
Excavation in post holes (or similar holes) each n exc 0.5cu .m,getting out in soft/loose soil, returning,filling in and ramming earth or broken rubble mixed with earth around,in layer not exceeding 25 cm,watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed by Engr-in-charge
M&L for PCC 1:3:6 Type C2 (using 40 mm graded stone aggregate) in walls or retaining walls, any thickness size of shape including,pilasters, boundary pillars and posts (including post and bases complete all as specified and as directed by Engr-in-charge
M&L for 60 mm thick machine pressed precast concrete interlocking paver block with grey cement and pigments any shape and size conforming to IS 15658-2006 of M-35 grade including even spreading of 25mm thick layer of sand cushioning incl watering & consolidation all as specified. all as specified and as directed by Engr-in-charge
Taking down carefully point wiring of any type (i.e. on wooden batten, surface conduit, casing-N- capping or concealed conduit) complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories such as wooden gutties/rawal plug, screw etc including making good disturbed surface to match the existing surface all as specified & directed.
Taking down old unserviceable existing street light any type such as fluorescent tube fitting/ HPSV/ HPMV fittings any wattage from the pole/ buildings, at any hight and refixing and connecting the same after repair all as specified & directed by Engineer-in-charge..
M&L for point wiring with PVC unsheathed cable single core stranded copper conductor 1.5 sq mm size, 1100 V grade, drawn into concealed conduit medium grade (ISI marked) not less than 20mm dia on surface with and including PVC unsheathed cable single core copper conductor 1.5 Sq mm as continuous earth wire all as specified & directed by Engr-in-charge for the following :-
(a) One light/fan/Exh point controlled by one switch 5 Amp one way
(b) -Ditto- all as per item no 114 but socket outlet 3pin 5 amps same board
(c) -Ditto- all as per item no.114 but socket outlet 3pin 5 amps independent board
-Ditto- all as per item No.114 here-in-before but for one socket outlet/metal clad socket of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed by Engineer-in-Charge
M&L in repair, Modular white cover plate with frame ( both inner plate & outer plate cover ), 1 module.
M&L in repair, Modular white cover plate with frame ( both inner plate & outer plate cover ), 2 module.
M&L in repair, Modular white cover plate with frame ( both inner plate & outer plate cover ), 3 module.
M&L in repair, Modular white cover plate with frame ( both inner plate & outer plate cover ), 4 module.
M&L in repair, Modular white cover plate with frame ( both inner plate & outer plate cover ), 6 module.
M&L in repair, Modular white cover plate with frame ( both inner plate & outer plate cover ), 8 module.
M&L in repair, Modular metal flush box 1 & 2 module
M&L in repair, Modular metal flush box 3 module
M&L in repair, Modular metal flush box 4 module
M&L in repair, Modular metal flush box 6 module
M&L in repair, Modular metal flush box 8 module
M&L in repair,Modular switch one way 6 Amp single pole & one modular.
M&L in repair, Modular socket 6 Amp 2/3 pin combined shattered ISI marked confirming to IS 1239 : 1997 having finger proof terminals with captive screws having front fixing & removing features without removing plates.
M&L in repairs, Modular socket 16/6 Amp 3 pin combined shattered ISI marked confirming to IS 1239 : 1997 having finger proof terminals with captive screws having front fixing & removing features without removing plates.
M&L in repairs, Modular switch 16 Amp single pole one way ISI marked confirming to IS 3854 : 1997 or latest IS having finger proof terminals with captive screws having front fixing & removing features without removing plates.
S& F in repair, Electronic type modular fan regulator step type 120 watt, 230 volt. 01 module
M&L in repairs modular metal enclosure DB TPN 415 Volt 4 way double door type with 200 amps rated bus bar for fixing MCB complete all as specified and as directed by Engr-in-charge
S&F in repairs, MCB DBs sheet metal enclosures single phase and neutral 240 Volt with 200 Amps rated bus bar Double Door Type, 8 ways complete all as specified & directed
M&L in repairs, MCB SP 240 volts, 5 to 32 Amps, 10 KA
M&L in repairs, MCB SPN 240 volts, 40 Amps, 10 KA
S&F in repairs, Ceiling rose, 3 phase/PVC/polycarbonate, isolated body
S&F MCB SP 6- 32 Amps 240V volt C curve 10KA, complete all as specified and directed.Make- Havells or equivalent make of L&T /ABB
S&F MCB isolator SPN 40 Amps 240V volt C curve 10KA, complete all as specified and directed.Make- Legrand Cat No 603237 or equivalent make of L&T /ABB
M&L in repairs lamp holder PVC polycarbonate type with back place suitable for battern fittings complete all as specified and as directed by Engr-in-charge
S & F 10 watts white battern LED fitting provided with high output diffuser size of Two feet 230 volt,50 Hz Make- Bajaj/Havells/CG/Philips
S&F in repairs, Ceiling rose, 3 phase/PVC/polycarbonate, isolated body
S & F in repairs, LED tube fixture/fitting 1x 20watt, decorative ultra slim square profile with extruded polycarbonate, environmental friendly, energy eficient ready to use prewired for including connecting up with twin core twisted flexible copper conductor cable with suitable size complete and all as specified and directed by Engineer- in Charge.”.
S & F in repairs, LED building Security light fitting 1x18watt with polycarbonate housing ,Aluminum gear tray duly prewired inbuilt LED module IP 65 Protection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sq mm including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS,FI clamp including plinth with nut bolts etc complete all as specified and directed.
S & F in LED street Security light fitting 1x30 watt with polycarbonate housing ,Aluminum gear tray duly prewired inbuilt LED module IP 65 Protection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sq mm including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS,FI clamp including plinth with nut bolts etc complete all as specified and directed.
S & F in LED street Security light fitting 1x20 watt with polycarbonate housing ,Aluminum gear tray duly prewired inbuilt LED module IP 65 Protection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sq mm including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS,FI clamp including plinth with nut bolts etc complete all as specified and directed.
Supply and fixing in repairs, decorative Post-top LED ,IP-65 protection,Resistant to impact and corrosion glare free and better free uniformity luminaire 40 watts incl provn of three core cable size 1.5 Sq.mm switch to fitting with all accessories and all as specified and directed by Engineerin Charge.
Sub main wiring with two single core 6 Sqmm ( nominal area ) PVC insulated copper conductor FRLSH/ FRL Sr, multi stranded unsheathed 1100 volts grade IS -694 marked in PVC concealed conduit including 4 sqmm copper conductor cable FRLSH/ FRLS as earth wire. Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuit conductor cable shall be measured and paid as single unit.
Taking down old u/s exhaust fan from cook house and supply and fix in replacement iron body 50 Hz, 230 volts, 400 mm sweep with louver (Old u/s Exhaust fan will be deposted at MES store for repair/reuse/condmenation bd.
Supply and fix Ceiling fan 1200 mm sweep 50 Hz, 230 volt single phase
Supply and fix Electric Geyser 50 ltrs single phase 50 Hz, single phase including down rod all as specified and as directed by Engr-in-charge
M & L for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 5 of MES SSR Part-I 1991 print and as directed .
Taking down old unserviceable LT cable, supply and Laying in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs and testing. XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, all as specified directed by Engineer In charge of cross sectional area of 10 Sqmm 2 core including taking down old unserviceable LT cable of cross sectional area of 10 Sqmm 2 core all as spcified and directed by Engineer Incharge
S&F service connection of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core multistandard cable flat or circular of 6 Sqmm 2 core including taking down old service cable complete all as specified & directed by Engineer-in-charge.
Excavation in trenches not exc 1.5m wide and n. exc 1.5M deep for fdn / trenches and getting out for soft / loose soil.
Removing excavated material n exc 50m and depositing at a level n.exc 1.5M above ground.
Returning/filling in layers, spreading leveling, watering and well ramming in layers n.exc 25m in sof/loose soil.
M&L for Tibba sand for sand cushioning to under ground cable including, spreading, leveling hand punning complete all as specified and directed.
Supply and laying Jodhpur stone patti for cable protection of lenth between 55 to 60 cm but width between 25 to 30 cm thicknes not less than 5 cm complete as per site requirement and direction of engineer in charge.
M/s Rashid Mohammed
Habib Traders
rathore construction co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .