Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹9.4 L
EMD Value
₹10,000
Closing Date
3 Jun 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
33/11KV S/S, RDC, Raj Nagar, Gzb.
Increasing Capacity of 33/11KV Substation Jewer Tehsil
2020_PVVNL_474115_1
02/2020-21
Open Tender
Electrical Works
Item Wise
30 days
Greater Noida
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
PVVNL, ECWD (D), Gzb.
₹10,000
Yes
5 Jun 2020
22 May 2020
3 Jun 2020
22 May 2020
3 Jun 2020
22 May 2020
180 days
1. Disconnecting HT cable connection from 33KV side & from 11KV side of 5MVA transformer for removing transformer from plinth.
2. Disconnecting Earthing strip from neutral & body of 5MVA transformer & Dismantling of neutral Earthing support safely.
3. a) Draining of transformer oil from conservator, radiators of existing 5 MVA T/F, at 33/11 KV S/S Jewer Tehsil, Gautam budh nagar into the dry & clean drums and staking at the safe place in Substation outside of switchyard. Empty drums shall be provided by department free of cost & shall be arranged by contractor from store to site under J.E, PVVNL
b) Opening of conservator radiators and other accessories from existing 5 MVA Transformer.
c) Safe Shifting of 5 MVA Transformer main body and other accessories from the substation switchyard to outside the switchyard.
4. a) Safe Shifting of 10MVA, 33/11 KV, Transformer from out side of switchyard to near transformer plinth in Switch Yard.
b) Erection of shifted 10MVA Transformer at plinth by fixing all accessories like radiators, conservator tank, filling the transformer oil to desired level and ensuring that there is no leakage, complete job in all respect.
c). Water level earthing by Boring and lowering of G.I. pipe size 40 mm dia & thickness 2mm into the ground at 50 Mtr depth or upto the water level with the lower end of solid copper cone Approx 225 mm long and 750 gm in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will be bolted to the M.S. earth Strip for Transformer neutral connection, the earth strip will be welded to the G.I. pipe and neutral earthing support.
d). Fabrication and erection of neutral earthing L Type support made of M.S. Channel size 100x50mm. Structure shall be 4 Mtr. long with 1 Mtr. Arms. Structure shall be grouted in ratio 1:3:6 in block size 300x300x700mm and painted with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint work includes connecting neutral bushing rod of power Transformer and M.S. Earthing strip with the help of flexible copper bond, M.S. Bolt and washer with stone Pad of size (300x300x75mm).
e). Fabrication and erection of cable support made of two pieces of M.S. Channel (100x50x6)mm, 2.75 meter long, joined to each other by means of 5 Nos. M.S. Angle (50x50x6) mm pieces of size 0.5Mtr long each by welding at equal intervals and grouting in a block of size (300x300x700)mm in C.C. 1:3:6 complete with one coat of ready mixed primer and two coats of Al. paint. Work includes providing of three Nos. M.S. clamps made of (50x6)mm M.S. Flat for holding the cable including nuts and bolts with stone Pad of size (300x300x75mm).
f) Fabrication and grouting of M.S. frames 3.60 mt. long for support of copper Bus Bar. Bus Bar will be provided in L.V. side of Power transformer. The M.S. frame shall be made of M.S. channel (100x50)mm in 'T' shape. Providing 2 Nos. support of M.S. Angle iron (50x50x6)mm, 0.60mt. long below the top channel, drilling of 3 Nos. hole on the top channel for fixing of 11 KV pin insulator. The M.S. frame shall be painted with one coat of primer & two coat of aluminium paint and grouting the frame in C.C. ratio 1:3:6 in a block of size (300x300x700) mm with stone Pad of size (300x300x75mm). The work also includes the fixing of 3 Nos. 11 KV pin insulator with pin and binding the copper Bus Bar with the pin insulator by Aluminium binding wire in complete.
g) Supply & Fabrication of copper bus bar of size (2500x50x6)mm in L.V. side of 5 MVA 33/11 KV, power transformer, Work includes connection of outside bus bar in L.V. side busing rod of Power Transformer and other side with outdoor 11 KV cable box as well as providing empire tape and H.T. tape etc. for proper insulation work.
5. L.A.'s, & P.I.'s Unit structure:- a) Fabrication of structure, including cutting, straightening & drilling of holes in Channel/Angle
b). Excavation of earth 2x(0.45x0.45x1.00)
c). Supply & fixing of stone pad of size 300x300x75mm
d). Erection of L.A & Post insulator structure in proper alignment
e). Grouting of structure in C.C ratio 1:3:6 2x(0.45x0.45x1.00)
f) Making plinth by C.C ratio 1:3:6, in size 2x(0.45x0.45x0.30)
g). 12mm thick plastering on plinth in ratio 1:4 of size 2x[2x(0.45x0.30)x2+2x(0.45x0.30)x2+2x(0.45x0.45)x1]
6. H.T. Power Cable Laying: a) Laying 11 KV, (3x300) mm2 XLPE, Cable from power transformer to 11 KV incoming switch gear in the cable trench 0.45 m wide, 0.90m depth. Providing 150 mm local sand for cushion beneath and 150 mm above the cable (quality of local sand required 0.375 cum/m in length). The cable shall be dully protected by brick. On both side of cable by laying brick vertically and bricks would also be laid bricks along the cable (minimum 18 Nos. of bricks are to be laid top and outer side along the cable. The work includes digging of trenches, laying of cable in under ground trenches, joining of terminal's, back filling of earth and testing and commissioning of power cable etc. Spare cable shall be left over and laid in the trenches in shape of 6 m ring at both ends.
b). Laying and dressing of 11 KV 3x300 mm2 power cable in air/Trench.
7. Preparation of 11 KV Power Cable ends: a). Making of 11 KV XLPE Heat shrinkable Out door jointing kits after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs.
b). Making of 11 KV XLPE heat shrinkable indoor jointing kits in switch gears after carefully removing the insulation of cable, providing and crimping of proper size of lugs, plumbing and taping of cable with good quality available insulation tape with J/Kit boxes, Fixing and insulating of lugs on cable with switch gear complete in all respect.
8. Laying of different size of (2x2.5)mm2/ (4x2.5)mm2/(6x2.5)mm2 control cables i.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT's to CT's Junction Box, CT 33 KV, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment.
9. Earthing of 11 KV indoor equipment a) Earthing of indoor equipments by means of G.I. Earthing strip 50x6mm including laying, cutting, bending and welding with existing earthing.
10. Earthing of 33 KV out door switchyard structrure: a) Earthing of outdoor equipments Bus Bar structure, T/F Neutral support & cable support structure by G.I. Earthing strip 50x6mm including laying, cutting, bending and welding with existing earthmat
b) Supply of G.I. Strip size 50x6mm for earthing of outdoor & indoor equipment
11. Painting of Structures Painting of the following structure with one coat of ready mixed primer and two coats of ISI Mark Aluminium paint after rubbing with sand paper to the surface of the structure including labour and T&P complete in all respect. a) Terminal gantry, Line Isolator, Bus Isolator, Post Insulator, Fuse Set and L.A's unit structure, CT structure
b). Cable support, neutral, support structure, Bus bar.
12. Provide required No. of technicians to work on power T/f, HT/LT panels during testing as assisting technical hands to test team during commissioning & energisation.
13. Loading, Safe carriage & unloading of following stock material from any stores centres under PVVNL, depending upon the availability of material at Stores Centres, with loading & unloading at both ends respectively. a) Steel, Angle channel etc.
b). 11 KV outgoing Switch gear VCB
c). 33KV L.A.
d). 11 KV Cable
e). Control cable
f). 11KV cable J/kit 3x300mm²
g). 33KV Post insulator
h). Battery Charger with Battery Set
14. Installation of 33 KV Lightning Arrestors: a) Installation of 33 KV Lightning Arrestors: Assembling and installation/mounting of 3 Nos. lighting arrestors on the L.A.'s structure/terminal gantry, complete with earthing and line connections. The work includes fabrication of structure for proper fixing.
b). Installation of 33 KV Post Insulators: Installation of 3 Nos. PI on structure. The work includes fabrication of structure for proper fixing.
15. Installation of 24V Battery and Battery Charger: Assembling and installation of the cabinet of 24V battery and battery charger in switch gear control room including grouting of foundation bolts as per drawing of manufacture, including providing the foundation nuts and bolts of proper size. The electrical connection between battery and battery charger with flexible copper lead of size 7/20 SWG shall be provided & done properly by the contractor. The work includes installation, wiring upto control panel, testing and commissioning complete in all respect.
16. Dismantling of 11KV damaged switchgear a) Removal of 11KV bus bar connection between 11KV Incomming VCB panel & adjacent 01 Nos. 11KV Outgoing VCB panel after ensuring shutdown at 33/11KV S/S Jewer Tehsil to facititate replacement of 01 No. damaged 11KV O/G VCB Panel
b) Safe shifting of 01 no. damaged 11KV outgoing VCB Panel from inside control room to out side of control room at safe place at Substation.
17. Installation of 11KV Switch Gear in control room Erection of 11KV Switchgears in proper alignment, in Control Room, including safe shifting, from Dump Place. Making 4No. Pockets for each and providing/fixing of Reg Bolt by CC in ratio 1:2:4, with tightening also, including safely mounting of 11KV P.T. on 11KV I/C Switchgear, filling of oil (if required), making all electrical connections. i) 11KV Outgoing VCB 400/200/5A, 350MVA
18. Construction of S.S.Os. Approach Road-1.2M wide in switch yard by laying dry brick-ballast in 15Cm layer, 115mm thick brick work 1:4 in both side of edge, providing 10Cm thick CC in ratio 1:2:4. the work includes proper plastering top & side of road and making groove, leveling & dressing of earth beneath the brick work on edge.
19. Supply & laying of chequred rubber sheet 2000mmx1000mmx20mm of ISI Marked.
20. Safe carriage of old dismentaled material & damaged 11KV VCB Panels 01 No. from site of work to PVVNL Store BSR distance approx 60km with loading & unloading at both ends.
M/S RAGHAV and BROTHERS
M/s HINDUSTAN ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .