Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance W O SUBODH KUMAR KEDAL FURHARA TOLI KEDAL RANCHI 835217 | RANCHI | RANCHI | JHARKHAND | 835217 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance SHRADHANAND ROAD MAHABIR CHOWK RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
21 Jun 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Minor Irrigation Division, Thakurbari Road Sakchi Jamshedpur
Inviting e-quotation for framing Rates (Non schedule items) for installation of Solar pump Under Lift Irrigation Schemes.
2022_WRD_59325_1
WRD/M.I.DIV. Jamshedpur_WRD_05/2022-23
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
30 days
Jamshedpur
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
23 Jun 2022
15 Jun 2022
23 Jun 2022
15 Jun 2022
21 Jun 2022
15 Jun 2022
180 days
Amount
For 20 Hp SPV AC Surface Pump
Solar module Mounting (Galvanised Steel) surface structure (for 50 kW) having Hot deep galvanised of Zinc thickness 80 micron and as per IS4759 with C Channel and anti theft with nut bolt of grade SS304, which should also withstand high wind velocity upto 150km/hr or as per MNRE.
50kWp SPV module of 330wP or higher rating, which must have Specification as per IS 14286/IEC61215. The midule must have to quility IS/IEC61730 part I and II (or having mechanical load test of 5400pa) for safety purpose. Module to Module wattage mismatch in SPV Array shall be +/-3% and to quality IEC TS 62804-2015 for detection of potential Induced degradation and warranted for output wattage not less than 90% in 10yrs abd 80% at the end of 25yrs as per MNRE.
SPV controller/VFD integrated with GPRS,having MPPT,Protection IP 65 or above as per MNRE to run 20HP AC Solar Pump.
Solar cable 4 mm2 used as per IS 694 or as per MNRE.
copper cable 95 mm2 used as per IS 694 or as per MNRE.
Arrangement of Lightening Arrestor excluding Earthing for 50kW & 3 nos. 20HP solar Pump.
20 H.P AC solar pump set of having performance with respect to Total Head. Maximum Current,Capacity, Voltage Range etc as per MNRE guidelines.
Array juction box ( IP 65 or above) as per MNRE for 50kW SPV.
Miscllaneous Accessories for Installation of 20H.P. solar pump
Supplying,Installation and commissioning Charge of Module and Structure for 50kW.
Maintenance for atleast 5 years or as per MNRE guidelines for 50kW SPV module & 1 nos. 20HP AC solar Pump with all accessories
For 10 Hp SPV AC Surface Pump
Solar Module Mounting (Galvanised Steel) surface structure for 50kW having Hot deep galvanised of Zinc thickness 80micron and as per IS4759 with C Channel & anti theft with Nut Bolt of grade SS304 which should also withstand high wind velocity upto 150km/hr or as per MNRE.
50 kWp SPV module 330wP or higher which must have Specification as per IS 14286/IEC 61215. The module must have to quility IS/IEC 61730 part I $ II (or having mechanical load test of 5400Pa) for safety purpose. Module to Module wattage mismatch in SPV Array shall be +/-3% and to quality IEC TS 62804-2015 for the detection of potential Induced degradation and warranted for output wattage not less than 90% In 10yrs and 80% at the end of 25yrs as per MNRE.
SPV controller/VFD integrated with GPRS,having MPPT,Protection IP 65 or above as per MNRE to run 10HP DC Solar Pump.
Solar cable 4 mm2 used as per IS 694 or as per MNRE.
copper cable 25 mm2 used as per IS 694 or as per MNRE.
Arrangement of Lightening Arrestor excluding Earthing as per MNRE for 50kW SPV & 1 nos. 10HP DC solar Pump.
10 H.P. D.C. (PMSM/BLDC/SRM) Solar pump set of having perfomance with respect to Total Head. Maximum Current,Capacity,Voltage Range etc as per MNRE guidelines.
Array juction box ( IP 65 or above) as per MNRE for 50kW SPV.
Miscllaneous Accessories for Installation of 10H.P. solar pump
Supplying,Installation and commissioning Charge of Module and Structure for 50kW.
Maintenance for atleast 5 years or as per MNRE guidelines for 50kW SPV module & 1 nos. 10HP DC solar Pump with all accessories
M/S ALLIANCE ENTERPRISES
Multi Marketing Services
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .