Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC PULWAMA JAMMU KASHMIR 192301 INDIA | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹42.1 L+₹64,765 (1.56%)Rejected-Finance HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹48.3 L+₹6.9 L (16.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹49.4 L+₹7.9 L (19.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS, C/o 56 APO
CLEANING OF UNDER GROUND AND OVER HEAD RESERVOIRS AND REPAIR REPLACEMENT OF EXTERNAL WATER DISTRIBUTION SYSTEM AT OFFRS MD ACCN OFFICES OFFR MESS AND MES COLONY AT BB CANTT SRINAGAR
2024_MES_665334_1
864/WS-48/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
GE 864 EWS
As per NIT
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹98,000
Yes
18 Oct 2024
11 Jul 2024
17 Sept 2024
11 Jul 2024
12 Sept 2024
25 Jul 2024
Amount
M&L for seven stage cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumps of following capacity UG sump/semi UG reservoir through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: Rays Cleantech/ Inus watertech/ satya enterprise. Seven stages are as under:- (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks. (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound. (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69.
NOTE:-(i) Company will submit Govt laboratory test cert of TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69, before cleaning, fix the sticker mentioning the date of cleaning & Name of site and also provide cert confirming the completion of the sterilization of water tanks mentioning the Name of station and date of cleaning. All the cleaning & sterilization staff should be under accidental insurance coverage. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scals and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for the revision. (iii) Sterilization team will be comprised of at least 30 % members who are minimum 03 months certificate holder in water tanks sterilization. (iv) Contractor will be responsible for rectification of complaints occurred during cleaning the tank. (v) The work shall be carried through specialized agency like Rays Cleantech/ Inus watertech/Satya Enterprise.
Filter bed 25000 Gallons capacity at Batwara Water Point.
Cleaning of water underground sump 50000 capacity at Batwara Water Point.
Cleaning of water underground sump 10000 gallons capacity at Batwara Water Point & AF 'O' Mess.
Cleaning of water underground sump 75000 Gallons capacity at BP (92 BH), Holiday Home, Arty Bde, Chinar Mess.
Cleaning of water underground sump 100000 Gallons capacity at Atal colony & 11 EW.
Cleaning of water underground sump 40000 Gallons capacity at CMP.
Cleaning of water underground sump 200000 Gallons capacity at New BP & Range Road I & II.
Cleaning of water underground sump 20000 Gallons capacity at Buchery I & II, Bhalu I & II, Kukri I & II and R Centre.
Cleaning of Water RCC over head reservoir 40000 Gallons capacity at 216 Transit Camp
Cleaning of Water RCC over head reservoir 50000 Gallons capacity at 216 Transit Camp
M&L Making V groove of 10mm wide and 30mm deep or upto the extend of joint/crack present at site over joint/ crack line using electricity operated angle grinder with diamond concrete saw blade and cleaning it by air blower as directed by Engineer-ln-Charge. The groove shall be cut on the concrete surface along the joint/crack over RCC structure to be repaired complete all as specified and directed. Note: Work to be executed by the authorized applicator of manufacturer only.
M&L for Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 400 mm in staggered manner or along the joint & crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm nozzle compatible with injection of grouting mix and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive SikaDur 31 or equivalent to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and directed.
M&L for Sealing of exposed 'V' groove of 10mm wide and 30mm deep with Sikagard 694 F(l) or Quick Fix or equivalnt solvent?free, moisture tolerant, thixotropic, two part structural adhesive and repair mortar cum surface levelling mortar. Note: Work to be executed by the authorised applicator of manufacturers only.
M&L for injection grouting of construction joints with non shrink cement slurry admixed with epoxy grouting Cebex 100 of M/S Fosroc Chemical /SikaGrout -214 IN @ 300 mm C/C including of opening of cracks to a groove of size 12mm X 12 mm, Nozzle at 300 mm C/C including of opening of cracks to be grooved of size 10mm X 10mm fixing of nozzles with fast setting plugging compound Renderoc plug, cutting the extra length of nozzle after grouting all in complete as per manufacturers instructions including necessary scaffolding as required and as per the directions of Engineers incharge complete all as specified and directed. Seal the nozzle with Sikagard 694 F(l) or equivalent thixotropic epoxy putty after the refusal of grout material from the nozzle. Note: leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost. Note: Work to be executed by the authorised applicator of manufacturers only.
Providing & Applying Two coats of SikaTopseal 107 or Aqua Arm Top Guard inside of the wall & floor of the tank, a two components ready to use polymer modified cementatious coating . First Coat should be applied horizontzlly and second coat should be applied verticallyThe thickness of coating shall not be less than I .5mm. complete all as specified and directed. Note: Work to be executed by the authorised applicator of manufacturers only.
M&L Applying two coats Sikagard 67 or AquArm Tank Coat, a water based epoxy coating certified for portable water on all over the concrete surface from inside.Apply the first coat by brush allow it to dry for 6-8 hrs and then apply 2nd coat and allow it to cure complete 24 hrs The coating shall be applied using brush application. The Thickness after two coating should not be less than 500 microns complete all as specified and directed. Note: Work to be executed by the authorised applicator of manufacturers only.
Notes for item Nos. 01.00 to 7.00:- Scaffolding required for execution of work at site shall be provided by the contractor and cost for the same shall be included in the quoted unit rates and nothing extra shall be admissible to the contractor on this account.
M&L for taking out existing filter media (sand and gravel) from filter bed and segregation of filter media for reuse and refilling of serviceable filter media and thrown away of unserviceable filter media for a distance exceeding 1Km from the site of work complete all as specified and directed.
Supply and laying of new filter media including all carriages from Ganderbal to site of work complete all as specified and directed for the following (a) Gravel of size 6mm dia (b) Gravel of size 2/3/4 mm dia (c) Fine sand Note : (i) The filter media consists of gravel and fine sand (ii) The sample of fine sand and gravel to be approved by the GE befor laying (iii) The size of layer of sand and gravel will be layed after approval of GE
Taking up or down GI/PVC/PP-R water tubing and connections including cleaning the pipes free from scaling for reusing the same in repairs / alteration etc to water pipes and connections complete all as specified and directed for the following sizes:-
15mm bore.
20mm bore
25mm bore
40 mm bore.
50 mm bore.
75/80 mm bore.
100/110 mm bore
150 mm bore
Re-laying /refixing or rerouting of GI/PVC/PP-R old water tubing and connection in new or old position including fittings with old/new bends, elbows, socket nipples, tapers, and reducers etc as per site requirement (on floors, walls and ceilings) complete all as specified and directed.
15mm bore.
20mm bore
25mm bore
40 mm bore.
50 mm bore.
75/80 mm bore.
100/110 mm bore
150 mm bore
Supply, laying, fixing and testing steel water tubes, medium grade, ISI marked, galvanized with all fitting laid in trenches complete all as specified and directed for following bore of pipes :-
15mm bore.
20mm bore
25mm bore
40 mm bore.
50 mm bore.
75/80 mm bore.
100mm bore
150 mm bore
Supply, laying and testing of Polypropylene random copolymer (PP-R) (PN-16/SDR 7.4)-3 Layers pipes, UV stabilized and antimicrobial welded having thermal stability with and including all PP-R plain & brass threaded polypropylene random fittings fixed such as bends, Elbow, Tee, Short Length, Socket, Union, Check Nuts, Nipples etc. (Females/Males as required), suitable for hot cold water supply line including making good disturbed surfaces/cutting chassis in CM 1:3, laid in trenches and including testing complete all as per manufacture’s instruction and all as specified and directed for the following outer dia of pipes:- Make:- SUPREME/PRINCE/KPT
20mm bore
25mm bore
40 mm bore.
50 mm bore.
S&F in repair GI fittings suitable for 15mm bore of pipe, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings :-
Union
All equal Tee
Socket
Nipple 50mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
All as per item No.15 above but GI fittings suitable for 20mm bore of pipe complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 50mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow/reducer elbow 20x15mm
Elbow
All as per item No.15 above but GI fittings suitable for 25mm bore of pipe complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 50mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 25x20mm
Reducer elbow 25x15mm
All as per item No.15 above but GI fittings suitable for 40mm bore of pipe complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 50mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 40mm x 25mm
Reducer elbow 40x20mm
Reducer elbow 40x15mm
All as per item No.15 above but GI fittings suitable for 50mm bore of pipe complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Elbow
Nipple 50mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer elbow 50mm x 25mm
Reducer elbow 50x20mm
All as per item No.15 above but GI fittings suitable for 80mm bore of pipe complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Elbow
S&F gun metal gate valve, ISI embossed, conforming to is 781-1984, connected with iron wheel head, screwed at both ends for iron pipes and fixed including taking down of unserviceable gate valve complete all as specified and directed for the following sizes:-
15mm bore.
20mm bore
25mm bore
40 mm bore.
50 mm bore.
S&F PP-R Gate valves (brass insert), with iron wheel head, screwed both ends for PP-R Pipes and fixed in repair for following bore of pipes :- Make:- SUPREME/PRINCE/KPT
15mm bore.
20mm bore
25mm bore
40 mm bore.
50 mm bore.
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for laying of pipe lines, valve chambers, man holes etc including forming bottom surface to required level and gradient and getting out in hard /dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for cutting of road up to a size not exc 1.5m wide and not exc 1.5m depth for laying of water pipe lines making good the disturbed surfaces so as to match with existing finishing with PCC 1:2:4 type B-1 and cement motor in CM 1:2 complete all as specified and directed
S&F stop valves, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc including taking down old unserviceable valve suitable for following bore of pipes:-
25mm bore
40 mm bore.
50 mm bore.
S&F in repair/replacement iron ball valve suitable for following bore of pipes:-
25mm bore
40 mm bore.
50 mm bore.
80 mm bore.
S & F pressure reduceing valve including taking down unserviceable valve any type suitable for following bore of pipes:-
20mm bore
25 mm bore.
50 mm bore.
Providing & applying Two coats of SikaTopseal 107 or Aqua Arm Top Guard inside of the wall & floor of the tank, a two components ready to use polymer modified cementatious coating . First Coat should be applied horizontzlly and second coat should be applied verticallyThe thickness of coating shall not be less than I .5mm. complete all as specified and directed. Note: Work to be executed by the authorised applicator of manufacturers only.
M&L for applying two coats Sikagard 67 or Aqua Arm Tank Coat, a water based epoxy coating certified for portable water on all over the concrete surface from inside.Apply the first coat by brush allow it to dry for 6-8 hrs and then apply 2nd coat and allow it to cure complete 24 hrs The coating shall be applied using brush application. The Thickness after two coating should not be less than 500 microns complete all as specified and directed. Note: Work to be executed by the authorised applicator of manufacturers only.
M/s Lal Enterprises (BID ID -3094647)
M/S FAISAL TRADING CO. (BID ID -3084349)
M/S BILAL CONSTRUCTION AND CO. (BID ID -3088052)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tender48.pdf
Tender Document • 2.69 MB
Tendernotice_1.pdf
Tender Document • 0.42 MB
BOQ_744026.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .