Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.3 LAccepted-AOC | 1 | Accepted-AOC LOI TO L-1 BIDDER ONLY | |
| 2 | 2₹39.5 L+₹73,398 (1.89%)Rejected-AOC AMTALA MAMUDPUR PAL PARA KANYANAGAR NIBARAN DUTTA ROAD SOUTH 24 PARGANAS WEST BENGAL 743398 | 743398 | 2 | Rejected-AOC LOI TO L-1 BIDDER ONLY | |
| 3 | 3₹40.8 L+₹2.0 L (5.18%)Rejected-AOC | 3 | Rejected-AOC LOI TO L-1 BIDDER ONLY |
Tender Value
₹37.3 L
EMD Value
₹75,000
Closing Date
28 Aug 2023, 4:00 pmClosed
SE OMC I BTPS
OFFICE OF THE SE OMC I BTPS
Works of Cleaning work of TG Hall of ATPS BTPS DTPS and Cleaning of WTP Coal Lab and Express Lab of 2x500 MW BTPS Anpara
2023_RVUNL_818588_1
T04/OGD/BTPS/2023-24
Open Tender
Miscellaneous Works
Fixed-rate
730 days
ATP ANPARA
AS PER PQC
3 documents required · 3 mandatory
₹1,180
Dy CAO CFA AND BO BTPS ANPARA
₹75,000
1 Nov 2023
7 Jul 2023
30 Aug 2023
10 Jul 2023
28 Aug 2023
10 Jul 2023
Amount
TG HALL CLEANING OF ATPS ANPARA
Up keeping of outer surface of H.P.I.P. and L.P. turbine and bearing of unit no.I/II/III of ATP
Up keeping of outer surface,main steam, CRH,HRH line, drain lines to H.P.H 5 & 6 BFP suction/discharge recirculation & balancing leak off pipe from 11 M to 12/23 M height in Unit-I/II/III
Up keeping of outer surface of H.P. & L.P. bypass line, gland seal steam line,HRH line, turbine valves their drain lines outer surface of LP heater including pipe lines, valves drain lines, 3 M to 11 Min Unit-I/II/III
Up keeping of outer surface of main ejector starting ejectors, condenser line CEPs re-circulation line, drain cooler drip line to deaerator in Unit-I/II/III
Up keeping of outer surface of BFP A,B&C man pump, booster pump & its motor including in pipe line, CWP,NRV valves, turbine flash tank, Unit flash tank, connected pipe lines in Unit-I/II/III
Up keeping of outer of CW pipes lines from condenser to CEPS and its motors including its suction discharge pipe,foundation/ platform etc
Up keeping of Unit drain tank pipe line, HP Heater drain pipe line,drip line to condenser & deaerator up to 0 M height , BFP lub oil coolers working oil coolers & connected pipe lines of oil & water in Unit-I/II/III
Up keeping of -4.5M level basement/floor, stairs,railing,platforms,walls between -4.5 M level and "0" M level in TG Hall of all the threeunits as per scope of work
Up keeping floor, passage and walls, chequered plates,grills,stairs,railings, and platforms of "0" m,03M,06 M level in TG Hall of all the three units as per scope of works.
Up keeping of 11 M level floor platforms, stairs etc. as per scope of works
Up keeping of spittoons situated in T.G. hall of all three units as per scope of works
Up keeping, sweeping & moping of ground floor area of Main fire pump house including (-) basement, jaala removal up to ceiling height & water washing of ground floor area from Compressor House (west side) floor of IIIrd Unit up to outer TG Hall Gate
Cleaning & sweeping of T.G area of UNIT # 4 of 2x500M W, BTPS, Anpara.
ZERO METER FLOOR AREA
Cleaning & sweeping of marble floor and the side marble walls in front of lift door of unit 4 & side railing of Unit #4 Side
7 MTR. FLOOR AREA
Cleaning & sweeping of marble floor and the side marble walls in front of lift door of unit 4 & side railing of Unit #4 Side
15 MTR. FLOOR AREA
Cleaning & sweeping of the marble floor and the side marble walls in front of lift door of unit 4.this & cleaning of Shift room including shift room,Kitchen room,Lunch room Except Toilet.Cleaning and spittoons including disposal of waste materials & putting in sand & lime
21 MTR. FLOOR AREA
Cleaning & sweeping of the floor of 21 Mtr. Floor Cleaning & sweeping of the marble floor and the side marble walls in front of lift door of unit 4.
27 MTR. FLOOR AREA
Cleaning & sweeping of marble Floor & the side marble walls in front of lift door of Unit 4. & Cleaning & sweeping of 27 Mtr. Floor .
MINUS FOUR (-4) MTR. FLOOR AREA
Cleaning & sweeping of - 4 Mtr. floor of T-G hall this includes the removal of jallas from side walls and cleaning of drains also of unit # 4.
DIFFERENT STAIRS.
Cleaning of stairs from - 4 metr to 27 mtr including cleaning of side marbel wall floor beam etc of unit #4
OTHER MISCLLAENEOUS AREA
Cleaning of other Misc. Area within TG Hall Except(Equipment,pipelines,Cable gallery,Toilets,Labs,Lift)
Cleaning & sweeping of T.G area of UNIT # 5 of 2x500M W, BTPS, Anpara.
ZERO METER FLOOR AREA
Cleaning & sweeping of marble floor and the side marble walls in front of lift door of unit 5 & side railing of Unit #5 Side
7 MTR. FLOOR AREA
Cleaning & sweeping of marble floor and the side marble walls in front of lift door of unit 5 & side railing of Unit #5 Side
15 MTR. FLOOR AREA
Cleaning of committee room& Cleaning & sweeping of the marble floor of TG hall and the side marble walls in front of lift door of unit 5
21 MTR. FLOOR AREA
Cleaning & sweeping of the marble floor and the side marble walls in front of lift door of unit 5.
27 MTR. FLOOR AREA
Cleaning & sweeping of marble Floor & the side marble walls in front of lift door of Unit 5.
MINUS FOUR (-4) MTR. FLOOR AREA
Cleaning & sweeping of - 4 Mtr. floor of T-G hall this includes the removal of jallas from side walls and cleaning of drains also of unit # 5.
DIFFERENT STAIRS.
Cleaning of stairs from - 4 metr to 27 mtr including cleaning of side marbel wall floor beam etc of unit #5
Cleaning & sweeping of WTP area various Labs and associated Areas of 2x500M W, BTPS , Anpara.
CLEANING OF COAL & OIL LAB.
General cleaning, sweeping with brooms & wiping with wet cloths with approved disinfectants of floors/ slabs/ bathrooms/ offices etc. of centrally air conditioned coal- oil lab. This includes the removal of jalla, dust etc. from outside/ inside of the building as &when required & also complete bathroom cleaning with a provision of phenyl.
CONDENSATE POLISHING PLANT, LAB & DOSING AREA etc.
General cleaning ,sweeping with brooms & wiping with wet cloths with approved disinfectant of floors of Unit # 4 & 5 sampling room, analyzer room & Express Lab in between F-G row & column 11-12. This includes the way to lowest & removal of above as & when required.
CLEANING & SWEEPING IN WTP AREA, WTP Lab, Soil Lab, C.A. Lab etc
General cleaning, sweeping with brooms & wiping with wet cloths with approved disinfectants of floors of Waste Water Pump House, DM Water Transfer Pump House, Sludge Pump House, Filter Back Wash Pump house, service Water Pump House, Compressor room, Chlorination store room & equipment rooms,Switch Gear Room,WTP lab. & connected Office. This includes the cleaning of the lab of WTP, Soil & CA lab. with wet cloth, etc
General cleaning of all the interconnecting drains(smaller drains which coonects to main drains), trenches inside the WTP area & removal of their choking if any etc. for the free flow of water.
General cleaning, sweeping with brooms & wiping with wet cloths with approved disinfectant of floors of DM Plant including degasser tank floor & chemical dosing area & the floor of Dosing room Excluding pump area.
General cleaning, sweeping with brooms Main Acid & Alkali Bulk Storage tank area, chemical dosing area of DM Plant, dosing pump house area in dosing room area, Acid & Alkali dosing area in waste water treatment system. Water washing of Acid, Alkali bulk Storage Tanks floor area.
Cleaning with blower, vacuum cleaner/ soft cotton of electric panels etc. installed in switch gear room from the outside only. Extra precaution has to taken against this cleaning.Removal of jalla, dust etc. from outside/ inside walls, roof of Waste Water Pump House ,DM Water Transfer Pump House, Sludge Pump House, Filter Back Wash Pump house, service Water Pump House, Compressor room, Chlorine Store room & Chlorine Room, Water ext
Cleaning of cable trenches and cable
Cleaning of all the cable trenches, cable racks inside of CPP area. Cable racks inside Regeneration Room, CPP Regeneration Room, CPP, Switch gear room, Cable trenches of CPP, Regeneration Room with hand cleaning/ air blowing etc. This includes the removal NOTE: Garbage collected after cleaning shall be disposed off in dust bin located out side of T-G hall.
Removal of algae & silt etc. from pits, tanks, clarifiers, channels & gravity filters etc. of WTP, 2 x 500 MW, BTPS, Anpara. [these works carried out in Equally distributed period in a year and as and when required as per site requirement]
Riser Tube of clarifier (16 Nos.)
Channel between aeration tower to detention tower (18x1.3x 1.2 m deep)Channel between clarifier to gravity filters (34.5x1 x 1.8 m deep),Aeretion Tower Detention Tower
Clarifier 2 No. (29.26 m dia x 6.4 m height each)Intake Channel of gravity filter (43x1x1.8 m deep)Back wash channel of gravity filters (38x1x2.3 m deep)
Gravity Filter complete (7.0x 4.1 m )
Waste water tank (3 chamber) (32 x 11 x 8 m deep each chamber )
Sludge Tank (9 x 9 x 4.2 m)
Pit No. 3 (2 Chamber) (17.3 x 13 x 6 m deep each Chamber)
TG hall cleaning by assistance of automated machine.
Operation/driving of Professional dust/solid durt removing automatic machine. and Professional floor scrubbing/ wet cleaning automatic machine
Cleaning & sweeping of T.G area of DTPS, Anpara.
ZERO METER FLOOR AREA Unit # 6. Cleaning & sweeping of following area of (i) Unloading bay (between A to B row and column No. 1 to 2), (357m2) (ii) Area near main entrance door (between B to C row and column no.1 to 2 & between A to B row and column no.2 to 3, 6 to 7), (78.53 m2). Unit #7. (i) Unloading bay (between A to B row and column No.20 to 22), (714m2) (ii) Area near main entrance door (between B to C row and column no.20 to 21 & between A to B row and column no.18 to 19, 13A to 14), (78.53 m2).
Cleaning & sweeping of floor and the side walls in front of lift door of unit 6&7, (552m2).
Ground floor Cleaning & sweeping (between A to C row and column no. 2 to 11 for unit 6 & column 11 to 20 for unit 7), (6448m2).
Cleaning of side wall from 'O' meter to 8 meter floor including ceiling & all structure (cleaning includes removal of jallas from the wall & structure also for Unit 6 & 7), (3120m2).
Cleaning of long pipe trenches, various drains pits, sump pits at-4 Mtr. level in T-G area by removing the cover and placing the cover to their position after cleaning works completion for Unit # 6 & 7.
Cleaning & sweeping of - 4 Mtr. floor of T-G area this includes the removal of jallas from side walls and cleaning of drains also for Unit 6 & 7, Note: Mud, Garbage collected after cleaning shall be disposed off in dust bin located out side of T-G hall.(2449m2)
Cleaning & sweeping of floor and the side walls in front of lift door of unit 6 & 7, (569m2)
Cleaning & sweeping of rest floor area including , side railing (between A to C row,column No. 2 to 9 for Unit # 6), and Column no.13 to 20 for Unit # 7 and passage of 2 mtr. Between B to C row, column 9 to 13, (6621m2).
Cleaning of jallas from the side walls & roof from 8.5 Mtr. To 17 Mtr. floor including the structure, (9918m2)..
Cleaning & sweeping of the floor and the side walls in front of lift door of unit 6 & 7. (569.38m2).
Cleaning & sweeping of 17 Mtr. floor area between A to B row, column 2-20. this job include the cleaning of complete 17Mtr. Floor area with detergent in January & June (i.e. twice in year) without any extra payment, (6003.38m2).
Cleaning & sweeping of floor area between A to B row including the passage from TG Hall to service house building, (74m2).
Cleaning and spittoons including disposal of waste materials & putting in sand & lime ( 12 Nos. spittoons in each Unit )
Cleaning, sweeping & removal of jallas from the side wall up to 24 mtrs. and including ceiling of this floor from B to C row & cleaning of glass window from inside and column structure between column 1 to 9 & 13A to 22,including cleaning of ralling along service house building & TG hall also including from A to B row, (2856m2).
Cleaning of complete 17 Mtr. Floor area by rubbing with cleaning agent & cleaning with wet scrubber to remove hard deposited dust etc. from the tiles of the floor, (6373.38m2).
Cleaning & sweeping of the floor and the side walls in front of lift door of unit 6 & 7, (210m2).
Cleaning & sweeping of the floor of 24 Mtr. Floor and cleaning of jallas from the side wall and including ceiling of this floor between B-C row,, (1387.13m2). i) Column no. 1 to 2 for unit 6. ii) Column 21to 22 for unit7.(Except cable gallary, A.C. Equipment room and cabins for maintenance division). iii) Column 1 to 22 including the side passage and railling
Cleaning & sweeping of 31.75 Mtr. Floor between B-C row, (1680m2). i) column no. 1 to 7 & 8 to 9 for unit 6, ii) column 13 to 22 for unit 7.
Cleaning ofjalla from walls and windows, (3278m2).
Cleaning & sweeping of Floor & the side walls in front of lift door of Unit 6 & 7, (169.75m2).
Cleaning & sweeping of 36 Mtr. Floor between B-C row, (1255m2). i) column no. 2 to 7 for unit 6, ii) column no. 17 to 22 for unit 7 iii) including platform of jali/grill & railing.
Cleaning & sweeping of Floor & the side walls in front of lift door of Unit 6 & 7, (210m2).
Cleaning of stairs from zero Mtr. To 32 Mtr. B-C row column 8 to 9 for unit # 6 and column 13 to 14 for unit # 7 with cleaning of concern grills platform, side wall & floor of different levels throughout the stairs, Beam & railing of stairs, (1238m2).
Cleaning of stairs from zero Mtr. To 36 Mtr. ( B-C row, column 1 to 2 for unit 6 & column 20 to 21 for Unit #7 with cleaning of concern grills platform, side wall up to 2 mtr. &floor of different levels throughout the stairs, Beams & railing of stairs, (1555.2m2).
Cleaning of stairs from zero Mtr. To 17 Mtr. ( A-B row, column 2-3 & 07-08 for unit 6 & column 13A-14 & 18-19 for Unit # 7 with cleaning of concern grills platform, floor of different levels throughout the stairs, Beams & railing of stairs, (1428m2).
Cleaning of stairs from below zero Mtre.level i.e. (-4) Mtr. to zero Mtr. in A-B row, column 3 to 7 for unit 6 & column 16-20 for Unit # 7 with cleaning of concern platform, Beams & railing, (85.6m2).
Cleaning of stairs from 32 Mtr. to 36 Mtr. ( B-C row, column 9A to 10 for unit 6 & column12 to 13 for Unit #7 with cleaning of concern grills platform, side wall up to 2 mtr. & Beams, railing, (171.2m2).
Cleaning & removal of Jallas / Dust from side walls, Column, ceiling & cleaning of glass window from inside of following area, (1889.25m2). 1) Ceiling of T G Hall from A to B row, column 1 to 22. 2) Wall Beam & column, glass window from inside along row A from column no. 2 to 20 from 17 Mtr. to the ceiling & Column No.1 to 2 & 20 to 22 from 8.5 Mtr. to the ceiling. 3) Wall Beam & column, glass window from inside along row C, from column no.2 to 21 from 24 Mtr. up to the ceiling .4) Wall Beam &column, glass window from inside, along column no. 1, row A to B from 0 Mtr. Up to the ceiling & column no. 22 from 0Mtr. to the ceiling. or other works as directed. NOTE :- E.O.T Crane shall be provided if available for cleaning / Removal of jallas / Dust from ceiling & side walls of T-G area.
Cleaning & sweeping of floor area of operator cabin (boiler & TG side) unit # 6 & # 7 of 2x500M W, DTPS, Anpara.(48 Sq.mtr.)
Disposal of garbage collected from above areas to garbage dumping yard, with the help of tractor trolly.
M/S NEW ENGINEERING COMPANY
M/S NEERAJ CONSTRUCTION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .