Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.6 LAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹1.5 Cr+₹50.7 L (51.8%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L2 | Rejected-Finance Other than lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Sr No 290 NO capable of handing more work load as mentioned in WLR HQ CECC Lucknow for Qtr Ending Dec 2025 |
| Sl No | Description | Qty | Unit | MB Enterprises L1 | M/s Dhapola Elevator and Engineering L2 |
|---|---|---|---|---|---|
| 1.00 | 1. Supply, installation, testing and commissioning of lift landing doors at G+11 and G+9 floors for existing lifts of make Johnson Lifts Private Limited, complete in all respects, including dismantling and safe removal of existing doors and making good disturbed surfaces.
Technical Specifications
Door opening :
(a)For 08 Passengers lift (02 Nos in G+9 & 09 nos in G+11) - 800x2000 mm (Width x Height)
(b)For 13 Passengers lift (02 Nos in G+9 & 09 nos in G+11) - 900x2000 mm (Width x Height)
Landing doors shall be automatic centre-opening/telescopic type (as per existing system), fabricated from minimum 1.5 mm thick stainless steel (SS 304) with hairline (satin/brushed) finish, having uniform vertical grain, free from dents, scratches, waviness, or visible joints. Finish shall be factory-applied and consistent across all floors.
Doors shall be provided with electromechanical interlock system conforming to IS 14665 / EN 81, ensuring fail-safe operation.
The complete door assembly shall include door panels, door operator with VVVF drive, header, gate lock, tracks, track rollers, hangers, gibs, door clutch, door sill (SS/aluminium), full-height light curtain/photo sensors, door motors, and all associated accessories.
Doors shall operate smoothly, noiselessly, and without vibration, and shall be suitable for heavy-duty usage with corrosion resistance. | 222 | Each | 38,900 ₹86,35,800 Lowest | 58,150 ₹1,29,09,300 |
| 2.00 | 2. Supply, installation, testing and commissioning of lift car doors at G+11 and G+9 floors for existing lifts of make Johnson Lifts Private Limited, complete in all respects, including dismantling and safe removal of existing doors and making good disturbed surfaces.
Technical Specifications
Door opening :
(a)For 08 Passengers lift (02 Nos in G+9 & 09 nos in G+11) - 800x2000 mm (Width x Height)
(b)For 13 Passengers lift (02 Nos in G+9 & 09 nos in G+11) - 900x2000 mm (Width x Height)
Car doors shall be automatic centre-opening/telescopic type (as per existing system), fabricated from minimum 1.5 mm thick stainless steel (SS 304) with hairline (satin/brushed) finish, having uniform vertical grain, free from dents, scratches, waviness, or visible joints.
The door system shall be provided with VVVF-controlled door operator for smooth, noiseless, and jerk-free operation.
The complete assembly shall include door panels, door operator, interlock/safety system, header, gate lock, tracks, track rollers, hangers, gibs, door clutch, door sill, light curtain/photo sensors, door motors, and all associated components required for proper functioning.
The door shall be fully compatible and synchronized with the existing lift control system and landing doors.
Safety devices shall conform to IS 14665 / EN 81 and ensure safe operation under all conditions. | 18 | Each | 64,000 ₹11,52,000 Lowest | 1,08,000 ₹19,44,000 |
| 2.01Notes for item no. 1 and 2 :- 1. The completed installation shall be inspected and approved by the competent Government Lift Inspector / Electrical Inspector as per applicable State Lift Rules. The contractor shall: a) Arrange inspection from the Lift Inspectorate b) Submit all required drawings, certificates, and documents c) Pay all statutory inspection fees and charges d) Rectify all observations raised during inspection The work shall be deemed complete only after obtaining statutory approval and fitness certificate from the Lift Inspector. 2. The Contractor shall guarantee the entire lift door installation (including landing doors and car doors, complete with all components, accessories, and systems) for a Defect Liability Period of 24 (twenty-four) months from the date of successful completion, commissioning, and handing over. 3. During the Defect Liability Period, the Contractor through OEM shall: 3.1Attend and rectify all defects, deficiencies, malfunctions, or breakdowns arising due to defective 3.2materials, workmanship, or improper installation. 3.3Replace defective components/parts with new ones of approved make at no extra cost 3.4 Ensure minimum downtime and maintain proper functioning of doors and safety systems | |||||
Tender Value
₹1.7 Cr
EMD Value
₹2.5 L
Closing Date
25 May 2026, 6:00 pmClosed
Col Manav Pant, CWE
HQ CWE (AF) Chakeri Kanpur
PROVN OF CERTAIN WORKS SERVICES TO LIFTS OF MULTISTOREY BUILDINGS AT AKASH GANGA VIHAR AT AFSK KANPUR
2026_MES_762217_1
CWE(AF)/CHK/EM/T-02 OF 2026-27 82483/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(AF) E/M CHAKERI
Pl refer tender documentd
7 documents required · 7 mandatory
₹1,000
GE (AF) E/M Chakeri
₹2.5 L
Yes
17 Jul 2026
25 Apr 2026
1 Jun 2026
25 Apr 2026
25 May 2026
17 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 1. Supply, installation, testing and commissioning of lift landing doors at G+11 and G+9 floors for existing lifts of make Johnson Lifts Private Limited, complete in all respects, including dismantling and safe removal of existing doors and making good disturbed surfaces.
Technical Specifications
Door opening :
(a)For 08 Passengers lift (02 Nos in G+9 & 09 nos in G+11) - 800x2000 mm (Width x Height)
(b)For 13 Passengers lift (02 Nos in G+9 & 09 nos in G+11) - 900x2000 mm (Width x Height)
Landing doors shall be automatic centre-opening/telescopic type (as per existing system), fabricated from minimum 1.5 mm thick stainless steel (SS 304) with hairline (satin/brushed) finish, having uniform vertical grain, free from dents, scratches, waviness, or visible joints. Finish shall be factory-applied and consistent across all floors.
Doors shall be provided with electromechanical interlock system conforming to IS 14665 / EN 81, ensuring fail-safe operation.
The complete door assembly shall include door panels, door operator with VVVF drive, header, gate lock, tracks, track rollers, hangers, gibs, door clutch, door sill (SS/aluminium), full-height light curtain/photo sensors, door motors, and all associated accessories.
Doors shall operate smoothly, noiselessly, and without vibration, and shall be suitable for heavy-duty usage with corrosion resistance. | 222 | Each | - | - |
| 2 | 2. Supply, installation, testing and commissioning of lift car doors at G+11 and G+9 floors for existing lifts of make Johnson Lifts Private Limited, complete in all respects, including dismantling and safe removal of existing doors and making good disturbed surfaces.
Technical Specifications
Door opening :
(a)For 08 Passengers lift (02 Nos in G+9 & 09 nos in G+11) - 800x2000 mm (Width x Height)
(b)For 13 Passengers lift (02 Nos in G+9 & 09 nos in G+11) - 900x2000 mm (Width x Height)
Car doors shall be automatic centre-opening/telescopic type (as per existing system), fabricated from minimum 1.5 mm thick stainless steel (SS 304) with hairline (satin/brushed) finish, having uniform vertical grain, free from dents, scratches, waviness, or visible joints.
The door system shall be provided with VVVF-controlled door operator for smooth, noiseless, and jerk-free operation.
The complete assembly shall include door panels, door operator, interlock/safety system, header, gate lock, tracks, track rollers, hangers, gibs, door clutch, door sill, light curtain/photo sensors, door motors, and all associated components required for proper functioning.
The door shall be fully compatible and synchronized with the existing lift control system and landing doors.
Safety devices shall conform to IS 14665 / EN 81 and ensure safe operation under all conditions. | 18 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
TenderT02.pdf
Tender Documents • 1.52 MB
BOQ_853779.xls
BOQ • 13.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .