| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC M 68 69 TRADE CENTRE 18 SOUTH TUKOGANJ INDORE M P | INDORE | INDORE | MADHYA PRADESH | ₹1.4 Cr | L1 | Accepted-AOC Lowest |
| 2 | Rejected-Technical | - | - | Rejected-Technical Ineligible |
| Sl No | Description | Qty | Unit | INTERNATIONAL MARKETING ORGANISATION L1 |
|---|---|---|---|---|
| 1.00 | Supply installation testing and commissioning of 132KV CT having ratio of 400/1-1-1 A. | 3 | Nos. | 6,00,000 ₹18,00,000 Lowest |
| 2.00 | Supply of 33KV CT having ratio of 400/1-1-1 A. as per standart of MPPTCL TOP Bottam Standard. | 2 | Set | 3,05,000 ₹6,10,000 Lowest |
| 3.00 | Supply installation testing and commissioning of 220/132/33KV s/s sec.-3 Support ABT, 3Phase 4Wire METER, Class 0.2S Make Secure. | 1 | Nos. | 3,99,000 ₹3,99,000 Lowest |
| 4.00 | Supply installation testing and commissioning of 200 KVA Conventional 5star Distribution Transformer. | 1 | Nos. | 6,98,000 ₹6,98,000 Lowest |
| 5.00 | Supply installation testing and commissioning of 18 Unit For 12MVAR Capacitor bank at 132Kv S/s | 1 | Nos. | 13,95,000 ₹13,95,000 Lowest |
| 6.00 | Supply installation testing and commissioning of 10KVA/48V Invertor cum battery for Custom Office use at Niryat bhavan SEZ-II. | 1 | Nos. | 99,500 ₹99,500 Lowest |
| 7.00 | Supply installation testing and commissioning of 110Volt. 300AH Make Hertz Electronics at 132kv S/s SEZ-II. | 1 | Nos. | 9,98,000 ₹9,98,000 Lowest |
| 8.00 | Supply installation testing and commissioning of 48 Volt. 200AH Make Hertz Electronics at 132kv S/s SEZ-II. | 1 | Nos. | 9,97,000 ₹9,97,000 Lowest |
| 9.00 | Supply Copper Control Cable 12 Core. 2.5 Sq.mm. (Armoured) | 200 | Meter | 450 ₹90,000 Lowest |
| 10.00 | Supply CT clamp sutable for 11 KV CT | 27 | Nos. | 1,250 ₹33,750 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
26 Dec 2024, 5:30 pmClosed
Senior Project Engineer
101, Atulya IT Park, Khandwa Road, Indore
RFP for Supply of various Electrical Material at I/A SEZ-II, Pithampur, Distt. Dhar (M.P.)
2024_MIDCL_387069_1
16284 RFP Supply Material at SEZ
Open Tender
Materials
Item Rate
60 days
SEZ Pithampur
As mentioned in tender document
4 documents required · 4 mandatory
₹11,800
₹1 L
26 Sept 2025
9 Dec 2024
30 Dec 2024
10 Dec 2024
26 Dec 2024
10 Dec 2024
Amount
Supply installation testing and commissioning of 132KV CT having ratio of 400/1-1-1 A.
Supply of 33KV CT having ratio of 400/1-1-1 A. as per standart of MPPTCL TOP Bottam Standard.
Supply installation testing and commissioning of 220/132/33KV s/s sec.-3 Support ABT, 3Phase 4Wire METER, Class 0.2S Make Secure.
Supply installation testing and commissioning of 200 KVA Conventional 5star Distribution Transformer.
Supply installation testing and commissioning of 18 Unit For 12MVAR Capacitor bank at 132Kv S/s
Supply installation testing and commissioning of 10KVA/48V Invertor cum battery for Custom Office use at Niryat bhavan SEZ-II.
Supply installation testing and commissioning of 110Volt. 300AH Make Hertz Electronics at 132kv S/s SEZ-II.
Supply installation testing and commissioning of 48 Volt. 200AH Make Hertz Electronics at 132kv S/s SEZ-II.
Supply Copper Control Cable 12 Core. 2.5 Sq.mm. (Armoured)
Supply CT clamp sutable for 11 KV CT
Supply 33 KV TTB
Supply 11 KV TTB
Supply 33 KV VCB, Outdoor Porcelain clad type with complete structure and accessories including existing Control pannel wiring for feeder protection excluding CT & pannel
Supply33 KV CT 1200/1 Amp as per standart of MPPTCL TOP Bottam Standard.
Supply33 KV CT Outdoor Oil immersed type 400-200/5-5 Amp
Supply Secure Meter 0.2 clss Accuracy premier series 300 3phase 4 wire
Supply 33 KV CONTROL & RELAY PANEL WITH OVER CURRENT AND EARTH FAULT STATIC RELAY FOR TRANSFORMER & FEEDER PROTECTION (AVANA)
SITC 33 KV VCB, Outdoor Porcelain clad type with complete structure and accessories CT & Breaker excluding CT & pannel
Supply 11 KV CT Outdoor Oil immersed type 300-150/5-5 Amp
Supply Handling & installation of 33 KV feeder/Xmer VCB complete on Foundation & tightening/ alingment of of VCB. With old VCB Dismentling
Supply Handling & installation of control pannel , including stand of suitable size for 33/11KV feeder and transformer control
Supply Installation Testing and Comissioning 33kv Isolator 800Amp. Copper contactors.
Supply DLMS compliant Single phase Electronic meter with data downloading facility & box 5-30 Amps Secure, genus.
Supply Three Phase whole current Smart Meter with Box 10-100 A with data downloading facility & Box
Supply Testing and commissionnng of VCB and control pannel
Supply SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB
Supply Copper Control Cable 2 Core. 2.5 Sq.mm. (Armoured)
Supply Copper Control Cable 4 Core. 2.5 Sq.mm. (Armoured)
Supply Copper Control Cable 8 Core. 2.5 Sq.mm. (Armoured)
SupplyCopper Control Cable 10 Core. 2.5 Sq.mm. (Armoured)
Supply Copper Control Cable 12 Core. 2.5 Sq.mm. (Armoured)
Supply Aluminium Cable 2 Core. 4 Sq.mm. (unArmoured)
2 x C Al 10 Sqmm Cable
2 x C Al 16 Sqmm Cable
1 x C Copper 2.5 Sqmm wire
100 Amps MCB
Supply Junction box for Hymast and street lights with inbuild 100 Amps MCB for main supply & 63 Amps for outgoing supply for Hymast and street lights
Supply 16 Sqmm cable Al 4 x C (four-core) (NON-ABC) having cloth covering suitable for Hymast connection
Supply 25 Sqmm Cable Al 4 x C ( Four core) Armoured cable (NON ABC) for providing 3 Phase supply to Hymast
Supply PVC Insulation tape
Supply 4 Point Connectors for Hymast
Supply 25 Sqmm Lugs for Hymast cables
Supply 2.5 SQMM Cu flexible wire
Supply PVC Tape 2*30(Box)
Supply M seal
Supply Ferrule (R,Y,B,N and 0 to 9) each 1 set
Supply PVC insulated PVC sheathed 3.5 core 35 sqmm Aluminium conductor 1100 Volts
Supply PVC insulated 2 core 10 Sqmm Cable
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .