Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC LOWEST BID QUOTED | |
| 2 | L2₹17.9 L+₹61,636 (3.56%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance HIGHEST BID QUOTED | |
| 3 | L3₹20.6 L+₹3.3 L (19.0%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-Finance HIGHEST BID QUOTED | |
| 4 | L4₹20.8 L+₹3.5 L (20.3%)Rejected-Finance | L4 | Rejected-Finance HIGHEST BID QUOTED | |
| 5 | L5₹21.8 L+₹4.5 L (26.1%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-Finance HIGHEST BID QUOTED |
Tender Value
Refer Docs
EMD Value
₹63,000
Closing Date
21 Sept 2020, 6:00 pmClosed
GE (AF) Gurgaon
GE AF Gurgaon
REPAIR REPLACEMENT OF LT UG CABLES, VOLTAGE STABLIZER, LT PANELS, STREET LIGHT, COOLING APPLIANCES AND OTHER MISC MAINTENANCE WORKS AT AF STATION NARAINA UNDER AGE EM AF RAJOKRI OF GE AF GURGAON
2020_MES_371681_1
GE/GUR-/NIT-31/2020-21
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹63,000
Yes
26 Oct 2020
24 Aug 2020
23 Sept 2020
24 Aug 2020
21 Sept 2020
7 Sept 2020
Amount
Supply, install, testing, and commissioning in replacement factory made feeder pillar compartmentalised indoor type ,weather proof ,dust and vermin proof double door front and rear openable made out of 3.15 mm thick CRCA sheet and angle iron 45x45x 6mm duly powder caoted ,suitable for floor /platform mounting of CPRI certified and IP65 class suitable for 415 volt ,3 phase ,4 wire ,50 hz AC supply sustem having busbar chamber with insulated aluminum busbars of rating 1200 amps installed on porcelain /SMC insulator with apron for cable entry ,closing locking arrangement with and including internal wiring with PVC insulated solid ,copper conductor FRLS cable ,IS 694 marked ,1100 volt grade of appropriate size (but not less than 2.5 sqmm ) and comprising of the following :-
Incoming :- (a) 4 Pole ACB 800 Amps ,415 Volts -01 No (b) Digital Voltmeter -01 No. ©Digital ammeter -01 No (e) Indicating lamps -01 Set of three Outgoing :- (a) MCCB 3 pole ,315 Amp ,50 Hz ,415 volts ,50 KA with magnetic and thermal release -1 No (b) MCCB 3 pole ,250 Amp ,50 Hz ,415 volts ,35 KA with magnetic and thermal release -3 No (c) MCCB 3 pole ,200 Amp ,50 Hz ,415 volts ,25 KA with magnetic and thermal release -2 No (d) MCCB 3 pole ,100 Amp ,50 Hz ,415 volts ,25 KA with magnetic and thermal release -2 No (e) Provision for Spare MCCB -2 Nos Platform of panel:- The platform shall be constructed as per Manufacturer drawing and design.
Supply, install, testing, and commissioning in replacement factory made feeder pillar compartmentalised outdoor type ,weather proof ,dust and vermin proof double door front and rear openable made out of 3.15 mm thick CRCA sheet and angle iron 45x45x 6mm duly powder caoted ,suitable for floor /platform mounting of CPRI certified and IP65 class suitable for 415 volt ,3 phase ,4 wire ,50 hz AC supply sustem having busbar chamber with insulated aluminum busbars of rating 400 amps installed on porcelain /SMC insulator with apron for cable entry ,closing locking arrangement with and including internal wiring with PVC insulated solid ,copper conductor FRLS cable ,IS 694 marked ,1100 volt grade of appropriate size (but not less than 2.5 sqmm ) and comprising of the following :-
(a) MCCB 4 pole 250 Amps 35 KA-01 Nos (For incoming). (b) MCCB 3 pole 100 Amps 25 KA-02 Nos (For Outgoing). (c) MCCB 3 pole 63 Amps 10 KA-02 Nos (For Outgoing). (d) MCB TPN 40 Amps 10 KA-02 No (For Outgoing). (e) MCB SPN 16A 10KA-2 Nos (f) Automatic timer switch current rating 40 Amp 4 pole 415 volt -01 No (g) Digital multi function meter (Volt meter 0-500V,Ammeter 0-400A, frequency meter & power factor meter) of size 96mmx96mm with programmable CT ratio with back up protection by 2 A MCB SP. (h) Indicating lamp 240 volts LED type - set of three (j) Internal All links & control cable and inspection lamp -01 (k) CTs 400 / 5 Amps - set of three
Platform of panel:- Platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone ,15 cm thick in foundation ,brick work in CM 1:6 with sub class B old size bricks ,rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be at a height of 45 cm above the nearest road level. The platform shall be constructed as per Manufacturer drawing and design.
M&L for Dehydration including filteration and cleaning of transformer / Voltage stablizer oil by dehydrating machine incl testing of sample before and after dehydration and filteration all as specified and directed . NOTE:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the deptt.
Supply & Filling /pouring of transformer / Voltage stablizer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed. NOTE:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site.
Disconnecting the deffective stablizer of Capacity upto 250 KVA from incoming and outgoing cables and opening the stablizers for checking the defects, draining out transformer oil and carrying to workshop for repair and back to site including making connections and testing complete including replacement of gasket set unserviceable nuts & bolts, washer complete all as specified and directed by the Engr in Charge.
Supply and fix in replacement of micro switch complete all as specified and as directed.
Supply and fix in replacement DPDT switches complete all as specified and as directed.
Supply and fix in replacement Auto mannual switch complete all as specified and as directed.
Supply and fix in replacement high and low voltage indicator complete all as specified and as directed.
Supply and fix in replacement of gear suitable for voltage stabilizer of any capacity and make complete all as specified and as directed.
Supply and fix in replacement of PCB holders suitable for voltage stabilizer of any capacity and make complete all as specified and as directed.
Supply and fix in replacement push button suitable for voltage stabilizer of any capacity complete all as specified and as directed.
Supply and fix in replacement potentio meter suitable for voltage stabilizer of any capacity complete all as specified and as directed.
M&L for taking down burnt jumpers and M&L for jumper connection between GOD and drop out fuses and transformers with ACSR conductor of size 6 of 1/3.5mm n.exc. 2m long including aluminium socket clamped both ends and PVC sleeves complete all as directed.
S&F in repairs switch air break, gang operated HT 11 KV triple pole, mechanically operated, mounted on insulators and steel frame, vertically or horizontally with operating mechanism worked from ground level, for current rating up to 400 amps complete including taking down existing unserviceable switch complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 65 KA suitable for earthed system 11 KV complete all as specified including dismantling existing arrester complete all as specified and as directed.
Material & Labour for dismantling insulators any type any size from position with out the disturbing to existing pole all as per specified and directed.
M&L for defect rectification HT/LTcable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault ; removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge as specified
Supply and jointing heat shrinkable straight through joint suitable for HT 11KV XLPE cable of size 95 sqmm 3 core complete all as specified and as directed
Supply and jointing heat shrinkable straight through joint suitable for HT 11KV XLPE cable of size 120 to 185 sqmm 3 core complete all as specified and as directed.
M&L for HT indoor termination cold shrinkable suitable for HT cable 11000 volts earthed grade 95 Sq mm 3 core complete all as specified and directed.
M&L for HT indoor termination cold shrinkable suitable for HT cable 11000 volts earthed grade 120 to 185 Sq mm 3 core complete all as specified and directed.
M&L for HT outdoor termination cold shrinkable suitable for HT cable 11000 volts earthed grade 95 Sq mm 3 core complete all as specified and directed.
M&L for HT outdoor termination cold shrinkable suitable for HT cable 11000 volts earthed grade 120 to 185 Sq mm 3 core complete all as specified and directed.
S&F MCCB 400 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed.
S&F MCCB 250 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed.
S&F MCCB 200 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed .
S&F MCCB 100 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed.
S&F MCCB 63 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
Supply and lay in trenches GI strip 25 mm x 4 mm galvanised iron strip for earth continuity earthing all as specified and directed
-ditto- but 32 x 6 mm galvanised iron strip complete all as specified and as directed.
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 300 Sq mm. complete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
ditto but 3.5 core 240 sqmm
ditto but 3.5 core 150 sqmm
ditto but 3.5 core 120 sqmm
ditto but 3.5 core 95 sqmm
ditto but 3.5 core 70 sqmm
ditto but 3.5 core 50 sqmm
ditto but 4 core 25 sqmm
ditto but 4 core 16 sqmm
ditto but 2 core 10 sqmm
ditto but 2 core 6 sqmm
S&F Indicating lamp 240 volts LED type complete all as specified and as directed.
Design Supply & Installation Of Complete Earthing Protection System With Copper Plate Of Size 300mm x 300mm x 2 mm Thick Buried Directly In Ground Connected To The Main Earth Lead Copper Strip 20mm x 3mm By Means Of 2 Set Accessories, Connected to Test Point Including Excavation in Rocky Type Of Soil, Providing Highly Treated Vegetable Soil, Earth Enhanced Compound Powder (ITPC EECP-15) Consists Of Copper Sulphate, Magnesium Sulphate, Graphite, Bentonite, Aluminium Silicate, Zinc Oxide & Iron Ore Alternate 15cm Layer Upto 15 Cm Above Top Edge Of Earth Plate, Construction Of PCC 1:2:4 Pit RCC Cover And Including Testing On Completion Complete In All Respect. (Note (i)Earth Lead Are Included Upto Test Point and on testing Earth Resistance should be Less Than 5 ohm) .(ii)Copper strip for interconnection for plate and taking out 2 Nos of copper strip of size 20 x 3mm from earth pit to test point for a distance not less than 7.5 Mtr.
S&F in repair mild steel hinges suitable for LT panel board shutters incl welding, riveting complete all as specified and as directed.
Disconnecting and taking down existing bus bars 4 wire system from LT panel board cleaning with CTC applying with becktol solution, removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel with new nuts, bolts, washers of suitable size complete all as specified and directed.
Disconnecting and taking out old existing worn out control wiring connections incl cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm incl new copper lugs and nuts, bolts, washers complete all as specified and directed.
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs and nuts, bolts, washers etc complete all as specified and directed.
Taking out old existing worn out neoprene gasket from shutters of LT panel board single door /double doors or openable on both sides and supply and fix new neoprene gasket complete all as specified and directed.
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified & directed .
M&L Foundation for Tubular swaged pole type Pole including excavation , getting out, pole foundation with PCC type D2 1:4:8 (with 40 mm graded aggregate). Coping of pole with PCC type C1 1:3:6 ( with 20 mm graded agregate) and removing surplus soil to a distance n.exc 50 m and making good surface all as specified and directed
Taking down and dismantling HPSV street light fitting with GI bracket for 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as specified and directed.
Taking down of street light fitting junction box including conduit pipe complete all as specified and as directed.
Taking down worn out PVC insulated copper cable 1.5 sqmm with steel rigid conduit complete all as specified and as directed.
M&L for wiring with two run single core PVC insulated, stranded unsheathed copper cable conductor size 1.5 Sqmm and drawing through and including S&F steel rigid conduit not less than 20mm dia and fixed on pole including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable connected to earth including connecting to earth dolly complete all as specified and as directed.
Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 45 watt rating and extendable upto 48 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed .
M&L for bracket in replecment for street light fitting made of 40mm bore light grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc all as directed.
Supply and fixing weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
Supply and fix automatic timer switch pole mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed.
Supply, laying & testing in replecement of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm
Supply and laying reinforced precast concrete cable cover class HV type-1, flat size 300mmx180mmx40mm
Maintenance/ servicing, cleaning Descaling and reconditioning of solar water heating system complete with of capacity 300 liters per day including with collector box of size (2120x1040x100 mm) 01 No of stainless steel tank by replacement of EPDM gasket ,nut & bolt ,GI fitting for existing water pipe line for inlet and outlet of stainless steel tank/ collector/water up to tank and making fully leak proof all as specified and directed.
S&F in Repairs Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete of size 40 mm
S&F in Repairs Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete of size 25 mm
S&F in Repairs Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete of size 20 mm
S&F in Repairs Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete of size 15 mm
S & F in replacement of gun metal non return valve 15 mm dia all as specified and directed
S & F in replacement of gun metal non return valve 20 mm dia all as specified and directed
S & F in replacement of gun metal non return valve 25 mm dia all as specified and directed
S & F in replacement of brass flange threaded type suitable for 25 mm dia of hot water pipe solar hot water system including nut & bolt of suitable size all as specified and directed
S & F in replacement of post top luminaries fitting with all accessories suitable for solar street lighting system including 15 Watt LED+Driver + Dusk to Down Facility. all as specified and directed
Supply and fixing replacement of Solar Charge controller suitable for 120 AH Battery backup system for solar light fitting. The solar charge controller should be of Microprocessor Based MPPT with 96% efficiency with IP 65 protection with dimming feature (100% light output for first 06 hrs and 40% dim for next 06 hrs). The charge controller shall provide reverse polarity and short-circuit protection using auto-resettable fuse complete all as specified and directed
M&L in repairs Lagging to pipes of sizes as per site in hot water supply all around with bounded mineral wool on outer side of hot water pipe line and covering with aluminium foils as per sample all as specified and as directed
S&F rubber gasket of various sizes of Solar Geysers as per sample all as specified and as directed
S&F U rubber for solar panel of Solar Geysers/Street Lights as per sample all as specified and as directed
S & F in replacement of Aluminium Cable lugs/Thimbles upto size 16 to 25 sqmm complete all as specified.
S & F in replacement of Aluminium Cable lugs/Thimbles of size 35 to 50 sqmm complete all as specified.
S & F in replacement of Aluminium Cable lugs/Thimbles of size 70 to 120 sqmm complete all as specified.
Supply and jointing straight through joint suitable for LT 415 Volt XLPE cable of size 25 to 120 Sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Supply and fix GI pipe light grade of following sizes for cable protection in trenches/ at PCC poles for loopin/ loopout of cable and cable entry at bldg/block end,all as per specified and directed.
(i) 80 mm dia
(ii) 50 mm dia
M&L 2.5 cm consolidated thickness bituminous mastic wearing course/mastic flooring with industrial bitumen of grade 80/25 prepared by using mastic cooker and laid to required level & slope including providing antisiked surface with bitumen pre coated fine fine graded hard stone chipping of approved size at the rate of 0.001 Cum per squire meter and at approximate spacing of 30 cm center in both direction, pressed into surface (Produst surface) 1mm to 4mm over mastic surface including applying the wearing coat of paving bitumen 80/100 @ 10 Kg of bitumen per 10 sqm area of road before applying the wearing coat complete all as specified and directed.
M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9/11 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and blue colour of synthetic enamel paint up to the height of 1.5 mtr from the bottm of the pole complete all as specified and as directed. Make : Nerolac/Asian paint
M&L for painting of PCC poles including cable protection pipe and all iron parts of 9/11 mtr long pole complete with 2 coats of paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and blue colour of synthetic enamel paint up to the height of 1.5 mtr from the bottm of the pole complete all as specified and as directed. Make : Nerolac/Asian paint
Supply and Fixing in repair LED flood light luminaire IP-66 grade of proterction LED of 120 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed .
Servicing, Oiling, Greasing and Cleaning of window type/ split type AC with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified & directed.
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 2.0 ton Split/W/T type AC
M&L for replacement running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and directed.
S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
Repair to compressor off size of existing makes and capacity for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
Rewinding of blower motor of capacity 1.5/2.0 Ton complete all as specified & directed.
S&F in replacement of new reciprocating type (hermetically) sealed AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5/2.0 Ton capacity complete all as specified & directed.
S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5/2.0 Ton capacity complete all as specified & directed.
S&F in replacement of Evaporator coil complete all as specified and directed.
S&F in replacement of Suction/Discharge valve complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and directed.
S&F of Copper tube cover complete all as specified and directed.
Material and labour for drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement
S&F of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and directed.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 ltr complete all as specified and as directed.
S&F in replcement of compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and as directed.
S&F in repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed.
M&L in replacement of starting relay and overload relay suitable for existing size and make water coolercomplete all as specified and as directed. Make: Epcos/Asian
M&L in replacement of starting capacitor for water cooler suitable for existing size & make water cooler complete all as specified and as directed.
M&L in replacement of running capacitor suitable for existing size & make water cooler complete all as specified and as directed.
Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etccomplete all as specified and as directed.
S&F in replacement of fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed.
M&L for servicing of deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including preparation of surfaces complete all as specified and as directed.
S&F compressor in replecement of sealed for Deep Frezeer complete all as specified and as directed.
S&F of starting relay of deep freezer of any size & make complete all as specified and as directed.
M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and as directed.
S&F of thermostat switch for deep freezer any make & capacity complete all as specified and as directed.
Repair and maintenance, refrigerator of any capacity including replacement of following UNSV Parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, complete all as specified and directed.
M/S Rohit Enterprises
Ridhi engineers and builders
J B Electricals
M/s Adhikari construction co.
New Era Engineers
M/S MG GROUP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .