Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC OK | |
| 2 | L2₹38.1 L+₹1.5 L (4.15%)Rejected-Finance 4 KHEME KA KUA PAL ROAD JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹38.7 L+₹2.1 L (5.85%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
23 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UTARLAI
GE AF UTARLAI PB NO 11 BARMER RAJ PIN 344001
CERTAIN MAINTENANCE WORKS AND SERVICES AT CHAUHTAN HILL TOP UNDER GE AF UTARLAI
2020_MES_389588_1
8133/08/E8 dt 24 Oct 2020
Open Tender
Civil Works
Item Rate
330 days
GE AF UTARLAI
As per NIT
7 documents required · 7 mandatory
₹500
GE AF UTARLAI
₹75,000
Yes
23 Feb 2021
24 Oct 2020
24 Nov 2020
24 Oct 2020
23 Nov 2020
7 Nov 2020
60 days
Amount
M&L for 'B' Check once in Six month or 250 Hrs running whichever is earlier DG sets of capacities as described in Ser Item No. 1.06 to 1.08. Inspection, maintenance and serviceing including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out maintenance as per OEM instructions and as directed by Engr-in-Charge. Note: Items/ Spares including 'B' Check kit, coolent, lubricating oil required shall be measured and paid separately under respective item of BoQ
Replacment of lubricant oil.
Replacing lubricant oil filters element with O rings
Replacing fuel filters element with O rings
Replacing air filter elements with O rings
Replacing coolant.
100 KVA Capacity, Make : Ashok Leyland Location : Near Bore well No-1
320 KVA Capacity, Make :Cummins, Location : Hill Top
15 KVA Capacity, Make : Cummins Location : AF Net Building
Supply only 'B' check kit for DG set of following capacities as mentioned in respective Ser Item No. 2.01 to 2.03. Note : It includes oil filters (1.00 Ltr/0.5 ltr), Diesel filters and air filters inner and outer as recommended by OEM
100 KVA Capacity, Make : Ashok Leyland, Model Location : Near Bore well No-1
320 KVA Capacity, Make :Cummins, Location : Hill Top
15 KVA Capacity, Make : Cummins Location : AF Net Building
Supply only coolent, K cool super plus 50-50 Premix
Supply only Battery water with electrolyte mix
Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil
Supply only radiator hose pipe set with clamps suitable for DG set of capacity 100 KVA
Supply only radiator hose pipe set with clamps suitable for DG set of capacity 320 KVA
Supply only fan belt set suitable for 100 KVA
Supply only fan belt set suitable for 320 KVA
Supply only fan belt set suitable for 15 KVA
Supply and fixing in repairs battery lead with Negative & Positive brass terminals of suitable size and length of each lead complete all as specified and directed
Servicing & repair to self starter of DG set of 15 KVA to100 KVA incl replacement of parts such as washer, nut, bolts, bush, solenoid, rotor etc. assembling and testing complete all as specified and directed by Engr-in-Charge
Supply & Fix in replacement of battery 12 V, 90 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals complete all as specified and directed by Engr-in-Charge. Make: Excide/ Amron/ Luminous
M & L for complete checking of AMF panel, finding the fault, servicing complete including replacement of unserviceable spares with necessary wiring and testing complete for manual & Auto operations complete all as specified and directed. (Note:- Items required for replacement will be measured & paid separately under respective item of BoQ)
Supply only in replacement of under and over voltage timing relay of AMF panel as per existing type, make and capacity complete all as specified and directed.
Supply only in replacement of AMF panel timer relay for circuit 230 V AC supply as per existing type, make and capacity complete all as specified and directed.
Supply only in replacement of AMF panel relay card 12 V DC supply for change over as per existing type, make and capacity complete all as specified and directed.
Supply only in replacement of AMF panel relay single with batch 8 pin 230 V AC supply as per existing type, make and capacity complete all as specified and directed.
M&L for replacement of unserviceable contactor 220 V AC supply, 4 pole suitable for the following capacity of DG set AMF panel:-
DG set 320 KVA
DG set 100 KVA
M&L in replacement of Start/ Stop switch with elements of AMF panel of any make and capacity.
M&L in replacement of solenoid switch for use of engine stop of AMF panel of any make and capacity.
M&L in replacement of Volt meter digital type of range 0-500 volts of AMF panel
M&L in replacement of Amp meter digital type of existing make,model and capacity of AMF panel
M&L in replacement of Indicator lamp 230 V AC Supply of AMF panel
M&L in replacement of battery charger 12 V DC SMPS 10 Amp for AMF panel
M&L in replacement of battery charger 24 V DC SMPS 10 Amp for AMF panel
Supply only in replacement of AMF panel control unit as per existing type, make and capacity
Supply and fix in replacement of AMF panel MCCB, 4 pole, 36 KA 200 amp capacity.
M&L earthing complete in replacement as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 32mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.
Supply install and testing outdoor weather proof bus bar chamber of size 120 cm x 40 cm x 40 cm made out of 18 SWG MS sheet having one side open able hinged door shutter with looking arrangement mounted on 40x40x6mm anlge iron frame with legs welded and 04 nos copper bus bar of 400 Amp rating provn of one MCCB TPN 125 Amp 16 KA for controlling Electric supply complete erracted on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles complete all as specified. NOTE: Cost of dismantling/ taking down old unserviceable bus bar chamber shall be included in the quoted rate of this
Supply and fixing in replacement of Street lights LED type 60W energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high power LED as lighting source of IP65 protection as complete including taking down of old unserviceable light fittings complete all as specified and directed by Engr-in-Charge Make: Havells/ Philips /Wipro/Crompton.
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade ISI marked bent to shape required, as per existing size fixed with and including MS flat iron clamps, bolts, nuts, washers complete including taking out old UNSV all as directed by Engr -in - charge.
Supply & fix pole mounted junction box SMC type, 3 phase 4 wire for street light including MCB TPN 32 Amp 10 KA - 1 No, MCB SP 6 Amp 10 KA - 1 No and accessories etc of complete all as specified. Make: Sintex or equivalent as approved by GE.
Material and labour for circuit wiring with two runs of single core 2.5 sqmm FRLS PVC insulated, flexible unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 1.5 sqmm single core FRLS PVC insulated, flexible, unsheathed multi stranded copper conductor green colour cable as earth continuity conductor from junction box to street light complete with PVC conduit pipe "medium grade" complet all as specified and directed. Note:- two runs of 2.5sqmm, 1 run of 1.5sqmm and 1 run of PVC conduit shall be measured as one unit.
Supplying , fixing and testing in replacement of timer switch 32A 2 pole/230V analog time switch with connecting items fixing on pole/wall/panel all as directed.
S&F in replacement of MCCB 4 pole, 415 V, adjustable type 100 Amps with breaking capacity 25 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian.
S&F in replacement of MCCB 4 pole, 415 V, adjustable type 63 Amps with breaking capacity 25 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian.
M & L for disconnecting and taking down U/S street light fittings of any type /rating from pole or wall dismantling the same for necessary repair or replacement of u/s spares complete and re fixing, connecting and testing the same complete all as specified and directed Note: (a) Spares/ accessories required for replacement shall be measured and paid separately as supply only under respective items of BoQ (b) T & P required for repair/maintenance such as ladder, vehicle manpower etc, shall be included rate of this item.
Supply only copper ballast suitable for HPSV/MH lamp fitting of the wattages Make Havells / Philips/Crompton Greaves/HPL
Supply only igniter suitable for HPSV lamp fitting of rating 70 watt street light fittings.
Supply only for HPSV lamp of rating 70 watt.
Supply only surge protection device
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade XLPE armoured, electric power cables (heavy duty) with aluminium conductor including taking out old UNSV cables with sand stone patties/sand of the following size complete all as specified. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs where ever required
150 sqmm 3.5 core
120 sq mm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
16 sqmm 4 core
M & L for LT Cable jointing kit for 1100 Volt (Earthed) grade cable for straight through heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm complete all as specified.
M & L for LT Cable jointing kit for 1100 Volt (Earthed) grade cable for straight through heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as specified.
M & L for LT Cable jointing kit for 1100 Volt (Earthed) grade cable for end termination heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm complete all as specified.
M & L for LT Cable jointing kit for 1100 Volt (Earthed) grade cable for end termination joint kit heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to120 Sqmm complete all as specified.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified.
S & F in replacement of LT cable route indicator cast iron of suitable size mountrd on 40X40X3mm angle iron with height of 1.5 Mtr long with LT cable trench including planting in ground with PCC complete all as specified and directed by Engr-in- Charge.
Surface dressing/ cleaning of surrounding Area of two pole structure/ substation and HT/ LT UG cable route area at open area, terrian area including removing of tree branches, small trees plants bushes etc complete all as specified and directed by Engr-in- charge.
Labour and machine required for locating fault in U/G LT cable 1100 Volts by using fault detector machine including transportation and by carried out high pressure test complete all as specified and directed by Engr-in- Charge. Note: required excavation and returning filling work deemed to be included in quoted rates.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 sq m on plan and not exceeding 1.5m depth and getting out any type of soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layer not exceeding 25 cm as in soil complete all as specified and directed.
Removing excavated material not exceeding 50 m and depostingwhere directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supplying and Laying stone patti 40-50 mm thick, 25- 30 cm wide abutting each other for cable protection complete all as specified and directed.
Supply and topping up of transformer oil with di-electric strength not less than 50 KV in to the conservator tank/ body tank of the transformer complete all as specified and directed by the Engineer-in-Charge.
Filtration of transformer oil of transformers/ FRMUs installed at various locations to achieve di-electric strength not less than 50 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtrationcomplete all as specified and directed by the Engineer-in-Charge.
M&L for preparation of old painted surface, cleaning of oils, lubricants, grease etc, steel tubular, swaged type poles complete of 11.0 mtr long poles with applying 2 coats of aluminium paint including brackets, cross arms clamps including writing pole Nos as before complete all as specified and directed. Location Hill top 2 pole structure.
M&L for preparation of old painted surface, cleaninig of oils, lubricants, grease etc, steel tubular, swaged type poles complete of 9 mtr long poles with applying 2 coats of aluminium paint including brackets, clamps including writing pole Nos as before complete all as specified and directed. Location : Hill top Street light poles.
S&F steel water tubing GI "medium grade" ISI marked with all fittings laid in trenches /wall etc complete for the following sizes including taking out old uerviceable pipe lines complete all as specified and directed by Engr -in- Charge :-
25 mm bore
50 mm bore
80mm bore
Supply and fix Gun - metal, globe or gate valve ISI marked with iron wheel head, screwed at both ends for iron for the following sizes including taking out old un serviceable gate valves complete all as specified and directed by Engr -in- Charge :-
25 mm bore.
50 mm bore.
Repair to single phase electric mono block pump 2 HP installed in pump house with the following works :- (a) Transportation of burnt motor to civil electric work shop. (b) Dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enameled copper wire of original gauge / size including tapping varnishing, drying, painting, assembling, to fixing of base plate, nuts bolts complete and carrying to site including necessary connection, commissioning and testing for 6 hours on full load (Major spare parts will be measured and paid separately under respective items) Note :- Cost of minor spare parts deemed to have been included in quoted rates by the tenderer.
Supply and replacing of following under mentioned worn out U/S parts of centrifugal 2 HP pumping set complete all as specified and directed.
Pump shaft for pumping set incl machining threading making key slot etc.
Gland bush
Guide spider complete with bush
Base Plate with bush including nut bolts
Ball bearing
Repair and servicing of RO water plant 150 ltr per hr installed in ORs Mess and hill top Adam block with the following works :- (a) Replace the UV filter with assembly . (b) Dismantling of RO unit and cleaning RO water storage tank, membrane ,removing inlet/outlet pipe and replace the Chemical tube complete servicing and cleaning the unit all as directed by Engr-in- charge Note :- Cost of unserviceable spare parts deemed to have been included in quoted rates
M&L for attending to break down of GI pipe of 50mm dia GI pipe line from Chautan Base UG sump to hill top UG sump including necessary site clearance, excavation, dewatering the water accumulated at site, removal of broken pipe pieces of various lengths through gas cutting/manual cutting as per site requirement and inserting same size of pipe as per existing site design, necessary PCC work including testing for the leakages pipes complete all as specified and directed by Engineer-in-Charge. Note: GI pipe 50mm dia shall be measured and paid separately.
M& L for testing of water for potability and biological analysis etc from the specified lab complete all as specified and directed.
S&F in repairs for flat submerssible copper conductor cable multistranded 3 core 6 sqmm 1100 Volt grade with water proof PVC insulated and PVC sheathed flat LT 1100 volts grade including jointing and lowering in tube well with column pipe for star delta connections of pump set complete all as specified and directed.
M & L in repairs for starter delta starter 440 V with suitable relay range fixed on suitable sheet metal enclosure outdoor type covered with canopy dist proof vermin proof, of 3mm thickness and welded with 25x25x5 mm angel iron frame with necessary 1:3:6 type D-2 PCC foundation for deep borewell submersible pump set complete all as specified and directed.
Supply and fix in repairs pressure reducer valve (PRV) with connecting accessories suitbale for delivery of pumpset at base to Hill top UG sump pipe line complete all as specified and directed.
M&L repairing of Submersible pump set with multi stage, electric driven 415 volt,50Hz capacity 5 HP including taking up from borewell with column pipe and lowering down by using of tripod/lowring machine with chain pulley 5 ton capacity complete all as specified and directed. (a) Transportation of burnt motor to civil electric work shop. (b) Dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enameled copper wire of original gauge / size with suitable for submersible motor, including tapping, Motor end shield, shaft sheild assembling and carrying to site including necessary connection, commissioning and testing on full load (Major spare parts will be measured and paid separately under respective items) (c) The nuts bolts/rubber gasket of column pipe will be replaced by new one. Note :- (i)Cost of minor spare parts deemed to have been included the quoted rates by the tenderer
S&F in replacement of following under mentioned worn out U/S parts of submersible pump set 5 HP for bore well complete all as specified and directed.
Bearing
Strainer
Shaft seal
S&F in repairs non return valve cast iron body both end flanged with neoprene ball duly tested and confirming to IS of size 50 mm bore (2'') complete all as specified and directed.
S&F in repairs Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm bore complete all as specified and directed.
M&L repairing of Submersible pump set multi stage, electric driven 415 volt,50Hz capacity 20 HP including taking up from Under Ground sump and refixing the same after repair by using tripad/ lowering machin ewith chain pulley 5 ton capacity Note: (a) Transportation of burnt motor to civil electric work shop. (b) Dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enameled copper wire of original gaug suitable for submersible motor end shield, shaft sheild assembling and carrying to site including necessary connection, commissioning and testing on full load (Major spare parts will be measured and paid separately under respective items) Note :- The above quoted rates inclusive the cost of minor spare parts.
S&F in repairs of following under mentioned worn out U/S parts of submersible pump set 20 HP for UG sump complete all as specified and directed.
Bush bearing
Strainer
Shaft seal
M&L for preparing old black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finaly the surface with gunny bags to remove all loose dirt etc. complete all as specified and directed.
M&L for applying evenly a priming / tack coat with bituminous primer at 05 Kg per 10 Sqm complete all as specified and directed.
M&L for Laying bituminous premix asphiltic semi dense concrete 30mm consolidated thickness with 5.5% binder content by weight of total mix, rolled and compacted to required camber and gradient complete all as specified and directed.
M&L for painting line, dashes, arrows letters etc on road pavements & the like exc 10 cm width or grith with thermoplastic paint having glass beads by using mechanical means complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified.
M&L for 10mm thick rendering in CM 1:6 on stone masonry surfaces and finishing the surface even and smooth without using extra cement complete all as specified.
M&L for 15mm thick rendering in CM 1:4 on stone masonry surfaces and finishing the surface even and smooth without using extra cement complete all as specified.
M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper over and including 3mm thick wall care putty complete all as specified.
M&L for two coats of oil bound distemper on newly plastered walls including necessary preparation of surfaces over and including 3mm thick wall care putty complete all as specified.
M&L for two coats of cement base paint on newly plastered surfaces of walls including necessary preparation of surfaces complete all as specified.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified.
M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for non-skid ceramic tiles 7 to 8 mm thick (square/rectangular), coloured tiles, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match shade of tiles laid over and including 15mm thick screed bed in CM 1:6 finished even and fair complete all as specified and directed.
M&L for Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular), coloured tiles, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match shade of tiles laid over and including 15mm thick screed bed in CM 1:6 finished even and fair complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350 x 250 x 7 mm /450 x 350 x 7 mm thick (glossy finish) on walls/vertical surfaces laid over and including 10mm thick rendering in CM 1:4 finished even and fair, complete all as directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) of any description and in any position.complete all as directed.
M & L 100 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified.
M&L 75 mm thick Cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in hard standing laid in alternate bay complete all as directed.
M&L for rubber moulded precast concrete interlocking paver blocks with pigments of any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade laid over & including 25 mm thick sand filling completed.complete all as Specified.
M&L for rubber moulded coloured chequred cement concrete tiles, 25cmx25cmx25mm thick, set, jointed and pointed in neat cement slurry in floors laid over and incl 15mm thick screed bed in CM 1:6.complete all as directed.
M&L for 25mm thcik PCC (1:2:4) type B-0, using 12.5mm garded aggregates as in base concrete to floor finish.complete all as directed.
Taking up or down steel tubing and connection including cleaning for refixing of 15 mm bore complete all as specified.
-ditto- as per item Ser No 98 above but 20 mm bore pipe complete all as specified.
Refixing old steel tubing and connections in new or old position as in walls, ceiling floors etc bore of pipe 15mm complete all as specified.
-ditto- as per item Ser No. 100 above but 20mm bore pipe complete all as specified.
S&F 15 mm bore galvanized steel tubing, "medium grade", with all fitting and fixed complete to walls celling or laid in floors complete all as specified and directed.
-ditto- as per item Ser No.102 above but 20mm bore pipe complete all as specified.
S&F in repairs Vitreous China wash basin, white, flat back, size 550x400mm including S&F of 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed, including waste coupling and brackets complete all as specified.
S&F in repairs PVC waste pipe of 32mm bore of 900mm length for WHB & Sink complete all as specified.
S&F in repairs grating doom 100mm dia of PTMT (min weight 25 gms) complete all as specified.
S&F in repairs Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified.
S&F in repairs bath room cabinet 350 x 450mm Make : Prayag, Commander, Polytuff complete all as specified.
S&F in reapirs 15mm bore two ways angle cock capstan head cast copper alloy chromium plated screwed down high pressure complete all as specified.
S&F in repairs 15mm bore brass CP wall mixer mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified.
S&F in repairs Brass chromium plated health faucet with necessary arrangements as per existing size complete all as specified.
S&F in repairs stop valves cast copper alloy fancy type, chromium plated screwed down high pressure with crutch or butterfly handle for 15mm bore complete all as specified.
-ditto- all as per item Ser No 112 but cup concealed type complete all as specified
S&F in repairs brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified.
S&F in repairs 15mm bore bib taps cast copper alloy, chromium plated, facncy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified.
S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified.
S&F in repairs brass chromium plated shower rose 125mm size complete all as specified.
S&F in repairs 20mm dia darpery rod in any length mild steel with PVC coating decorative type.
S&F brass superior quality bracket decorative suitable for 20mm dia drapery rods fixed on 100 x 10mm round block of first class hard wood.
Taking down chowkats or frames with shutters (without taking off shutters) n exc 1.5 sqm each complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters) exc 1.5 sqm but n exc 4sqm each complete all as specified.
S&F factory made solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification complete all as specified
S&F Factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap inserted for top rail and bottom rail. Penelling of plain colour PVC sheet to be fitted to the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame at site complete all as specified
S&F 35 mm thick factory made, second class hard wood, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part - I), kiln seasoned and chemically pressure treated complete all as specified.
S&F 35 mm thick factory made second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), supplied and fitted to chowkats complete all as specified.
S&F 300 mm long mild steel sliding door bolts, clip type, stove enameled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified.
S&F 150 mm size mild steel pressed handles, oval type, stove enameled black complete all as specified.
S&F 200 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified.
S&F floor door stopper, with 140 mm long cover plate, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor complete all as specified.
S&F Butt hinges,100 mm size extruded aluminium alloy with galvanised mild steel hinge pin,anodised & fixed type B-22 complete all as specified.
S&F Aluminium tower bolts of extruded section of size 150mm complete all as specified.
S&F extruded aluminium alloy handles, fabricated type, anodized of size 100 mm complete all as specified.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S&F in repairs Vitreous China squatting pan, `Orrisa' pattern, size 580 x440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified
Cleaning and removing all scale and dirt etc from storage water tanks of capacity exc 250 ltrs but n exc 500 ltrs including cleaning of mouths of circulating pipes by applying bleaching powder and brushing with wire brushes taking out all scales etc cleaning of tank with fresh water, flushing out disinfecting of tank with potassium permaganate 2% solution till stored in tank become clear complete all as specified and as directed
S&F Rotational moulded polythylene water storage tank of capacity 500 litres (Cylindrical, Vertical with closed top) hoisted an fixed in position and painting the tank with two coats of heat resistant paint including dismantling of the old unserviceable water tank complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S&F in repairs 20mm bore Ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed compete all as specified and directed Note : Minimum weight of ball valve shall be 210 gms
Taking down old broken cover and M&L PVC threaded coller with PVC cover fitted on PVC water tank with help 4 Nos PVC nut & bolt suitable for 500 ltrs capacity water tank complete all as specified
-ditto- as per item No 140 above but tank of capacity 1000 ltrs complete all as specified
S&F in repairs 10 litres capacity, cast iron, valveless, syphonic action type, flushing cistern, high level, with intlet, ball valve, float, chain and pull, and brackets complete all as specified.
S&F factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded complete all as specified
S&F factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete without glazing bars complete all as specified
S&F factory made steel ventilator with top hung shutter including box type hinges, steel peg stay, complete.
Excavation in post holes (or similar holes) each n.exc 0.5 Cum getting out, returning filling in and ramming with earth around in layers n.exc 25 cm thick, watering and removing surplus soil to a distance n.exc 50 mtr and making good surfaces in Soft/ disintegrated rock complete all as specified.
M&L cement concrete (1:3:6) type C-2 using (40 mm graded stone aggregate) as in boundry pillars, posts (including caps and bases) complete all as specified
S&F in repairs mild steel work as in posts and struts n fencing including cutting tops in shape as directed drilling holes, notching for wire etc complete all as specified.
M&L for two coats of synthetic enamel paint on steel surfaces of any description over one coat of red oxide over 10 cm in width or girth not otherwise described including preparation of surfaces complete all as specified.
S&F in repairs galvanised, 2 strands, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolt including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads or from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones complete all as specified.
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beads in square n.exc. 0.5 sqm in each pane complete all as specified.
S&F in repairs stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden beads supplied with shutters complete all as specified.
M&L for preparation of surface of walls including pillars etc (plastered or unplastered) by scrapping down smoke spot moulds, moss and efflorescent salt and treating oil and greasy sports and applying one coat of white wash all as specified.
Description all as per item No 152 above but one coat of white wash on ceiling.
M&L for preparation of old surface of walls including pillars etc by washing rubbing down and scrapping of distempered and painted surfaces and applying one coat of distemper oil emulsion all as specified and as directed.
M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of any tint all as specified and as directed.
M&L for preparation of old painted surfaces of iron steel works of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of any tint all as specified and as directed.
M&L for one coat of cement base paint on old surfaces of walls including necessary preparation of surfaces.
Distmantling of stone/boulder/block masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on stone masonry surfaces finished even and smooth without using extra cement with using integral water proofing compound as per manufacturer instructions. Note: Integral Water Proofing compound shall be measured and paid for separately as “Supply only”.
Supply only integral water proofing compound ISI marked.
M&L PCC Block masonry with solid block exc 10cm in width in PCC 1:3:6 type C-1 using 20mm graded stone aggregate and setting in CM 1:6 complete all as specified.
M&L for 15mm thick rendering in CM 1:4 on block masonry surfaces and finishing the surface even and smooth without using extra cement.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering
M&L for Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof coverin/cladding wall fixed with self tapping screwas as specified
M&L for stone walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6.
M&L for rendering 15 mm thick in CM (1:4) on stone masonry surfaces finished even and smooth without using extra cement with using integral water proofing compound as per manufacturer instructions. Note: Integral Water Proofing compound shall be measured and paid for separately as “Supply only”.
M&L for mild steel TMT bars 10 mm dia and above, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
M&L for cleaning pipe lines 150mm dia by rodding from Man holes and well flushing with water after cleaning all as specified & directed. Note:- Contractor shall depute his supervisor to collect complaint from AGE(B/R)-II office at 9.00am to 5.30pm & after cleaning the line get checked from Engineer-in-Charge.Complaint of blockages should be completed with in 24 hrs, if the same is not attended, a recovery of Rs 250/- per complaint shall be made.
All as per item No. 169 above but 100mm dia.
Clearing of blockage of Nahani Trap of bath room, kitchen by rodding blockage including taking down/refixing of grating etc complete all as specified and directed by Engineer-in-Charge. Note- Contractor shall depute his supervisor to collect complaint from AGE(B/R)-II office at 9.00am to 5.30pm & after cleaning the line get checked from Engineer-in-Charge.Complaint of blockages should be completed with in 24 hrs, if the same is not attended, a recovery of Rs 250/- per complaint shall be made.
Clearing of blockage of gully trap of bath room, kitchen by rodding blockage including taking down/refixing cover complete all as specified and directed by Engineer-in-Charge. Note- Contractor shall depute his supervisor to collect complaint from AGE(B/R)-II office at 9.00am to 5.30pm & after cleaning the line get checked from Engineer-in-Charge.Complaint of blockages should be completed with in 24 hrs, if the same is not attended, a recovery of Rs 250/- per complaint shall be made.
Clearing of blockage of Indian type WC/ Europion type WC by rodding/ pumping by hand including taking out door/refixing of over access covers etc complete all as specified and directed by Engr-in-Charge. Note:Contractor shall depute his supervisor to collect complaint from AGE(B/R)-II office at 9.00am to 5.30pm & after cleaning the line get checked from Engineer-in-Charge.Complaint of blockages should be completed with in 24 hrs, if the same is not attended, a recovery of Rs 250/- per complaint shall be made.
Cleaning of manholes of size n.exc 1.00 sqm plan area (internal) and n.exc 1.00 Sqm depth from GL including removal of manhole covers carefully, cleaning of sludge etc and refixing the manhole covers with cement mortar (1:4) (Sluge shall be removed outside MD land)
Pumping out sewage water/sludge from existing septic tank/soak well of any size & capacity and removal the sludge to out side MD land
Demolition and breaking up drain pipes, (Salt glazed stoneware, AC or reinforced concrete) 150mm (internal dia) set in cement mortar.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 150 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested.
M&L for salt glazed stone ware drain pipes of 150 mm internal dia, grade `A’ ISI marked laid to slope in trenches, jointed in CM 1:1 and tested complete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains of 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( ½ round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
M.D. CONSTRUCTION CO.
Godara Construction and General Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .