Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹45.2 L+₹1.1 L (2.44%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹46.1 L+₹2.0 L (4.45%)Rejected-Finance MES CHOWPATTI HASIMARA DIST JALPAIGURI WB PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹46.1 L+₹2.0 L (4.57%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹46.9 L+₹2.8 L (6.38%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
11 May 2023, 6:00 pmClosed
GE(AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215 (WB)
REPAIR/MAINT OF INTERNAL WALLS INCLUDING PLASTERING AND ALLIED WORKS AT OFFICE ACCNS IN TECHNICAL AREA, REPAIRS TO FLOORING, SUNKEN AND ALLIED WORKS AT BASRA ENCLAVE, LIVING AREA, MES AREA, TECH ACCNS AND OFFICE ACCNS IN TECH AREA
2023_MES_589595_1
C/8654/23-24/E8
Open Tender
Civil Works
Item Rate
240 days
GE(AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) HASIMARA
₹94,000
Yes
17 May 2023
15 Apr 2023
15 May 2023
15 Apr 2023
11 May 2023
29 Apr 2023
Amount
Taking down cement plaster on brick/concrete surfaces of any description and in any position incl racking out joints, hacking for key scrubbing down with water etc, complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick or concrete surface finished even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 15mm thick in CM (1:4) on fair faces of brick work conctete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:4) with using WPC on fair faces of brick work or conctete surfaces finished even and smooth without using extra cement complete all as specified and directed. (WPC shall be measured and paid separately)
M&L for applying two coats of oil bound distemper over a coat of primer over a coat of 1 mm thick wallcare putty on wall including preparation of new surfaces of walls, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15cm thickness (below or above ground level), complete all as specified and directed
M&L for 75 mm thick plain cement concrete (1:3:6) type C-2, ( using 40mm graded crushed stone aggregate) in sub floor, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in CM (1:6) complete all as secified and directed.
M & L for Joint free white non skid ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding. 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over 15mm thick screed bed of cement plaster (1:6) to fix the tile complete all as specified and directed.
M&L for vitrified ceramic tiles , light shade, 10mm thick (square/ rectangular) polished, area of each tile n.exc 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade including 15mm thick screed bed of cement plaster (1:6) to fix the tile complete all as specified and directed.
M & L for Chequered cement concrete tiles (Glossy finished) 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey pigments cement and pigment and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M & L for finishing of newly plastered walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (Shade - Dark Green/ Camoflague(Area not exc 1.00 Sqm) /as Directed), complete all as specified.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete in floors over and incl, 20mm thick screed bed with cement plaster 1:4, complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed pith pigment to match the shade of the slab including rubbing and polishing incl, 10 mm thick cement plaster (1:3), complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick cement plaster (1:4) as backing coat, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any any mortar complete all as specified and directed.
M&L for 25 mm thick plain cement concrete (1:2:4) Type B-0( using 12.5mm graded stone crushed aggragate) as in sub base of floor using WPC, complete all as specified and directed. (WPC shall be measured and paid separately)
Taking up or down 15 mm dia steel tubing and connection including cleaning for refixing or removal to store, complete all as specified and directed.
S&F GI tubes 15mm dia medium grade with all fitting and fixed complete to walIs and ceilings or laid in floors, complete all as specified and directed.
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size630x 450 mm white, with integral foot rests (excluding flushing cistern and flush pipe), complete all as specified and directed
S&F in repair 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket, complete all as specified and directed.
S&F in repair 15 mm dia bib tap standard of PTMT any colour screwed for iron pipe and fixed. (minimum weight 90 gms), complete all as specified and directed.
S & F in repair grating round 140 mm size of PTMT (Minimum weight 50 gms), complete all as specified and directed.
M&L for 450x300x7mm thick glazed ceramic colour tiles on vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick cement plaster (1:4) as backing coat, complete all as specified and directed.
M&L for 75 mm thick plain cement concrete (1:2:4) type B-1, (using 20mm graded crushed stone aggregate) as in sub base of floor , complete all as specified and directed.
Supply only liquid water proofing compound of approved quality , complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connection including cleaning for refixing or removal to store complete all as specified and directed.
S&F steel tubes, galvanised 20 mm bore, medium grade with all fittings and fixed complete to wall and ceiling or laid in floors etc , complete all as specified and directed.
Cutting chases, pinning in, making good to facings of brick wall where required and pointing, in CM (1:3) cutting exc 10 cm but not exc 20 cm girth , complete all as specified and directed.
M&L for hard core of broken bricks / brick bats n exc 63 mm, deposited, spread and levelled in layers n exe 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M & L for an elastic liquid applied , creck bridging 2 pack acrylic polymer modified cementitious waterprofing coating system primer coat Sika Top Seal - 109 hi Primer consumption primer coat 0.2 kg/sqm ,Base coat Sika Top Seal - 109 hi consumption base coat 0.7 kg/sqm Top coat Sika Top Seal - 109 hi consumption primer coat 1.5 kg/sqm Density 1.6 kg/ltr bond strength 2.0 N/mm OR Nitco Proof 100 & 120 of make M/S Fosrock chemical ( priming coat of Nitoproof 100 & one susequent coat of Nitoproof 120 ) or equivalent make as approvedby GE all as per manufacturing instruction, complete all as specified and directed.
Dismantling/taking down CI/PVC/AC pipes of exc 50mm dia with all fittings, complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor of 110mm bore , complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floor of 75mm bore, complete all as specified and directed.
S&F PVC (SWR) bends of 110mm bore , complete all as specified and directed.
S&F PVC (SWR) bends of 75 mm bore , complete all as specified and directed.
Taking down unserviceable flood light/post top lantern/Bollard light of any capacity/any size, from existing pole, complete all as specified and directed.
M & L for servicing of up-down function of High mast light including greesing, oiling, replacement of minor parts, including replacement of control wiring for electric auto up-down function etc, complete all as specifed and directed
M&L for providing plain cement concrete (1:2:4) type B-1, (using 20mm graded crushed stone aggregate) as in coping, complete all as specified and directed. Note : - (Pole copping shall be carried out above ground level for existing pole)
Taking dwon worn out, unserviceable time switch and supply & fixing astronomical time switch in existing street light timer panel for switching on /off lights and other electric devices according to the susrise / sunset times based on the entered location or location coordinates, complete all as specified and directed. Make : L & T, GIC, Model No T2DDT7 or equivalent model of make Legrand/ ABB/ Siemens
S&F LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant made out od pressure die cast aluminium housing with toughened glass and high power LED and secondary lenses, System efficacy > 110 LPM and 10 KV SPD included complete with driver and lamp complete with polycarbonate junction box and connecting wire copper 2.5 sqmm 3 core up to junction box , complete all as specified and directed.. Make : Philips / Havells/ Crompton, etc
S&F in repairs PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings with suitable size copper lugs incl taking down existing cable, complete all as specified and directed.
M&L for earthing & testing complete with GI earth plate electrode 60cmX60cmX6mm thick buried directly in ground vertically to a depth not less than 2.25mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including earth lead wire 4 mm dia by means of bolts, nuts and check nuts and washers etc. made of GI & connected to earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt I including all necessary earth work, excavation, PCC chamber, (1:2:4) B1 & RCC (1:2:4) B1 chamber cover with suitable reinforcement with handle including 15mm bore GI light grade protection pipe upto 7.5m length & 20mm bore GI medium grade watering pipe and wire mesh, funnel, char coal dust, common salt, wire mesh etc. , complete all as specified and directed.
Supply and fixing of LED type integral aviation obstruction light (Heavy duty) IP65, single light fitting comprising of die-cast aluminum housing with red polycarbonate dome for better illumination, Integral driver, supper flux 5mm 302nos LEDs incorporated. powder coated aluminium housing with polycarbonate enclosure including taking down unserviceable one aviation light fitting, complete all as specified and directed. Make : Bajaj Model No BGAV 302 LED or equivalent.
Taking out existing unserviceable/ defective light fitting / high bay light fitting of any wattage from poles/walls/ high mast (including taking down of high mast fitting), dismantling the complete fittings of checking out the defects, trace out damage/ unserviceable parts like driver, wire, led lamp etc and clean thoroughly the complete set and re-fixing in its original position after replacing defective parts including testing , complete all as specified and directed. Note :- (a) Any minor item like nuts, bolts, clamps, washers and wires for connection is required to make the fitting serviceable are deemed to be included in the quoted rate (b) Defective parts replaced against relevant items shall be paid under supply only item.
Supply only OEM LED driver suitable for 30 Watts LED Flood Light luminaries , complete all as specified and directed. of Make : "SURYA" / PHILIPS / CROMPTON/Legrand .
Supply only OEM LED driver suitable for 45-50 Watts LED outdoor (Flood light/Street Light) luminaries , complete all as specified and directed.of Make : "SURYA" / PHILIPS / CROMPTON/Havells/L&T/Siemens/Legrand.
Supply only OEM LED driver suitable for 60 Watts LED outdoor (Flood light / Street Light) luminaries, complete all as specified and directed. of Make : "SURYA" / PHILIPS / CROMPTON/Havells/L&T/Siemens./Legrand .
Supply only OEM LED driver suitable for 72 - 80 Watts LED outdoor (Flood light / Street Light) luminaries , complete all as specified and directed.of Make : "SURYA" / PHILIPS / CROMPTON/Havells/L&T/Siemens/Legrand. .
Supply only OEM LED driver suitable for 120-150 Watts LED outdoor (Flood light / Street Light) luminaries , complete all as specified and directed. of Make : "SURYA" / PHILIPS / CROMPTON/Havells/L&T/Siemens/Legrand. .
Supply only OEM LED driver suitable for 180-200 Watts LED outdoor (Flood light / Street Light) luminaries , complete all as specified and directed. of Make : "SURYA" / PHILIPS / CROMPTON/Havells/L&T/Siemens/Legrand.
S&F in repair of contactor TP, 40 Amp, complete all as specified and directed. Make : SURYA"/ PHILIPS/ CROMPTON/ Havells/ L&T/ Siemens/ Legrand.
M&L for attending of breakdown in Fire Fighting System in technical area, detection of nature of defect including carry out minor repairs, loose connection, change of small length of wire as required size to make the machine/equipment functional, opening of switch board / panel board and refixing the same after necessary repair, etc complete all as specified and directed. Notes: - (a) The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the machine functional for minor repair. If replacements of parts / items is required to make the equipment/machine functional the cost of labour and material for the same shall be measured and paid for as " S & F in repairs/M & L for" under relevant items of this schedule hereinafter. (b) If breakdown shall not be attended & rectified the same day as received by the contractor except rewinding of Motor and other major spares as specified , the recovery will be made @ Rs.1000/- per breakdown per day. And after 15 days of nonfunctional of any machine as specified for any reason the recovery will be made @ Rs. 2000/- per day till the machine operational.
Comprehensive service/repair/maintenance and monthly visit for regular maintenance for the automation of intelligent addressable fire alarm control panel and flowchart based programmable RTU at ACFTRW, ERS/APU, Parachute Bay & DWR building including checking testing and cleaning of Loop card ,Main board, LCD display, Printer Panel,AC filter,Transformer,Lead acid batteries, Invertor, Multisensor, sounder, MCP,Beam Detector,Repeater Panel, Zone monitor Module, UV&IR detector,Remote Response indicator, Loop Isolator ,Amplifier and Loud speakers carrying out normal repairs for the trouble free and efficient functioninig of the entire fire alarm system by providing one engineer for Monthly visit all as specified and as directed . Note:- (i) Cost of new components shall be paid for separately under relevant items of schedule 'A" .
Dismantling, servicing of all multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling , complete all as specified and directed.
Servicebility and testing of beam detector for each establishment/building considered as one unit and its transmitter and receiver alignment with testing kit as per OEM instructions manual, complete all as specified and directed.
Servicebility and Testing of UV & IR flame detector and its alignment to detect flame with Testing Kit as per speicified guideline in tender particular specifications once in every month till completion of the contract.
Supply of GSM SIM card services with validity SMS packs for 11 months for control & monitoring charges , complete all as specified and directed.. Note:- GSM service provider shall be choosen (as per network availability) by Engr-in-Charge and in the name of contractor for 11 months only.
S&F in repair of Indoor addressable detectors complying with and type certified to EN-54 addressable type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence , complete all as specified and directed. Make: GST/ COOPER/BOSCH/SIEMENS
Supply only electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below , complete all as specified and directed.:- a)Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A , c) Initiating Mode- Pressing the action plate manually resuming Mode-Manually resumed by a special Key, d) Ingress Protection IP-43 & Material-ABS Make: GST/ COOPER/BOSCH/SIEMENS
Supply only annunciating device remote response indicator complete all as specified and directed. Make:- GST/BOSCH/SIEMENS
Supply only fire alarm sounder cum strobe electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65db to 120db measured at 1.5 m with sound output variation of +5db 500m range complete all as specified and directed. Make:- GST/COOPER/BOSCH/SIEMENS
Supply, install, testing & commissioning of wireless modem suitable for GSM based communication system to be mounted in RTU enclosure shall be installed at all proposed buildings. Make:CIMCON/ MOTOROLA/ SIMOCO/ SIEMENS
Supply only Zone Monitor Module compatible with Fire Alarm Control Panel , complete all as specified and directed. Make: GST/ COOPER/BOSCH/SIEMENS
Supply only 24 V DC Power Supply Unit of RTU , complete all as specified and directed. Make : CIMCON /SIEMENS
Supply only CPU card of RTU , complete all as specified and directed. Make : CIMCON /SIEMENS/ABB
Supply only Analog and Digital I/O Card of RTU , complete all as specified and directed. Make : CIMCON /SIEMENS/ABB
Supply only DI/AI Termination PCB of RTU , complete all as specified and directed. Make : CIMCON /SIEMENS/ABB
Supply only Display and Keyboard of RTU , complete all as specified and directed. Make : CIMCON /SIEMENS/ABB
Supply only DO Termination PCB of RTU , complete all as specified and directed. Make : CIMCON /SIEMENS/ABB
Supply only of MCB 6A SP , complete all as specified and directed. Make: HAGER/HAVELLS/L&T/SCHNEIDER
Supply only of LEDs (Red/Green) for RTU Panel , complete all as specified and directed. Make : SAFETEK/CIMCON/POWERTEK
Supply only of Relay card : 8 relay 1 c/o for RTU panel , complete all as specified and directed. Make :CONNECTWELL/BRISK/ELMEX
Supply only of Isolation transformer—300 VA for RTU panel , complete all as specified and directed. Make :SAFETEK/CIMCON/POWERTEK
Supply only of push button with no contact (black), complete all as specified and directed. Make: ESBEE or equivalent model as approved by GE
Supply only of GST200-2 Main Board F2.908.826a for FACP , complete all as specified and directed. Make: GST or equivalent model as approved by GE.
Supply only of GST200 Rubber Keypad F7.843.249 for FACP , complete all as specified and directed. Make: GST or equivalent model as approved by GE.
Supply only of GST200 Loop Interface Board F2.908.828 (RoHS) for FACP, complete all as specified and directed. Make: GST or equivalent model as approved by GE.
Supply only of GST200 Power Supply Unit F2.932.069 (20100682) for FACP, complete all as specified and directed. Make: GST or equivalent model as approved by GE.
Supply only of Transformer 220V/27V-100W-R for FACP , complete all as specified and directed. Make: GST or equivalent model as approved by GE.
Supply only two core copper conductor of size 1.5sqmm FRLS flexible shielded cable , complete all as specified and as directed.
S&F gun metal fire hydrant valve 63 mm dia, single headed with flanged inlet and instantaneous out let on the existing stand post with brass nipple, including necessary bolts, nuts and washers including taking down unserviceable old one complete all as specified and directed. Make : Essel/ Fire marshal/ SRI/ Ever safe/ Newage/ Aadi/ Fire cool
S&F gun metal fire hydrant 63 mm dia, double headed with flanged inlet and instantaneous out let on the existing stand post with brass nipple, including necessary bolts, nuts and washers including taking down unserviceable old one complete all as specified and directed. Make : Essel/ Firemarshal/ SSRI/ Ever safe/ Newage/ Aadi/ Fire cool.
S&F in repair hose male S/S coupling 63mm dia for hydrant valve ISI marked including taking down old unserviceable one complete all as specified and directed. Make : Essel/ Firemarshal/ SSRI/ Ever safe/ Newage/ Aadi/ Fire cool
S&F in repair hose female S/S coupling 63mm dia for hydrant valve ISI marked including taking down old unserviceable one complete all as specified and directed. Make : Essel/ Firemarshal/ SSRI/ Ever safe/ Newage/ Aadi/ Fire cool
S&F in repair sprinkler quick / early response type as per IS:15105/TAC guidelines 68 degre temperature rating complete including fixing in the existing line and making good as per existing , complete all as specified and directed..
S&F first aid hose reel, wall mounted swinging type complete with drum, bracket, globe valve/ stop cock of size 19 mm dia, 30 mtr long high pressure hose reel tubing with branch pipe gun metal shut off nozzle including taking down unserviceable old one complete all as specified and directed. Note:- Hose reel shall be as per IS 884 and hose tubing as per IS 8090 ; Make : Eversafe/Newage/SRI/Mahveer
S&F 15m long rubber lined woven jacketed hose pipe 63 mm dia, type A (Reinforced rubber lined) as per IS 636 with necessary instantaneous spring lock type coupling at the ends to match with landing valve/hose pipe/branch pipe with gun metal male and female coupling conforming to IS 903 complete all as specified and directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
S&F fabricated MS hose cabinet, made of 18 gauge MS sheet 800mm X 600mm X 250mm double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside brilliant white inside and including taking down unserviceable old one complete all as specified and as directed.
S&F 63 mm dia branch pipe gun metal instantaneous inlet and made 15 mm bore nozzle short complete all as specified and directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
S&F, Fire brigade inlet connection 4 way valve ISI marked including taking down unserviceable old one complete all as specified and directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
S&F, in repair of Pressure switch Universal type all as specified and directed. Make : Danfoss / Indfoss /Honeywell
S&F, in repair Pressure Gauge, 100mm dia, 0 - 14 Kgs rating complete all as specified and directed. Make : H Guru /Baumer/ Mass
S&F, in repair 500 litres capacity ISI marked rotational molded polyethylene water storage tank (cylindrical Vertical with Close top ) hoisted and fixed in position , complete all as specified and directed. Make : Sintex (ISI Marked)/ Polycon (ISI marked)/Polytuf (ISI marked)
S&F in repair 150mm bore of cast Iron, butter fly valve complete all as specified and directed. Make : AUDCO / C&R / INTERVALE / KARTHAR/RAMCO
S&F in repair 100mm bore of cast Iron, butter fly valve complete all as specified and directed. Make : AUDCO / C&R / INTERVALE / KARTHAR/RAMCO
S&F in repair 150 mm bore cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle , all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR/RAMCO
S&F, in repair 100 mm bore cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR/RAMCO
S&F in repair 80 mm bore cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle , all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR/RAMCO
S&F , 150mm cast iron foot valve including taking down old one from the suction side of pump set from the sump and making good the disturbed all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR/RAMCO
S&F , 100mm cast iron Foot valve including taking down from the suction side of pump set from the sump and making good the disturbed all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR/RAMCO
S&F , 80mm cast iron Foot valve including taking down from the suction side of pump set from the sump and making good the disturbed all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR/RAMCO
S&F, in repair three pole power contactor MNX 95, 2NO+2NC complete all as specified and directed. Make : L & T /ABB/GE/SIEMENS
S&F, in repair three pole power contactor MNX-80, 2NO+ 2NC complete all as specified and directed. Make : L & T /ABB/GE/SIEMENS
S&F, in repair three pole power contactor MNX-70, 2NO+ 2NC complete all as specified and directed. Make : L & T /ABB/GE/SIEMENS
S&F, in repair three pole power contactor MNX-70, 2NO+ 2NC complete all as specified and directed. Make : L & T /ABB/GE/SIEMENS
S&F Control relays (Auxilary contactor) 415V, AC MX0-40E (4 NO) , complete all as specified and directed.
S&F Control relays (Auxilary contactor) 415V, AC MX0-22E (2 NO + 2 NC) , complete all as specified and directed.
S&F thermal over load relays 66-110 Amp range, direct mounting suitable for MNX contactor , complete all as specified and directed.
S&F thermal over load relays 22-40 Amp range, direct mounting suitable for MNX contactor , complete all as specified and directed.
S&F electronic timer type ST 100 complete as specified and directed. Make : L&T/ABB/GE/SIEMENS
S&F automatic motor startor suitable for 1.5 HP single phase submersible pump, digital type single phase controller microprocessor based with dry run protection, auto start/off of motor, UV/OV protection, complete with control wiring in PVC conduit , complete all as specified and directed.
S&F , in repair Push button with indicator ( set of three R Y B ) for panels , complete all as specified and directed. Make : L&T/ABB/GE
S & F Power Pack, industrial type,80 AH, 12 Volt ,13 Plate, allong with copper lead and clamp , complete all as specified and directed.. Make: Exide/Amaron/ or equivalent make as approved by GE
M&L for carry out general servicing and maintenance to diesel engine driven pump / fuel injection pump of capacity 85 HP including B check and service as per manufactures recommendation ,overhauling including replacement of oil filter ,air filter ,gland packing ,diesel filter with replacement of O rings ,Engine Oil and toping up of Coolant up to required level etc which ever be required to making 100 % serviceability of the engine complete all as specified and directed
All as per item No 118 here in above, but of capacity 75 HP all as specified and directed.
Disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to locate the fault and transporting to the local work shop. Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire gauge super enameled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engineer-in-charge. Coupled the motor with pump and installed at site as per existing position. Testing the pump set after completion of work, complete all as specified and directed of capacity 70/75 HP.
All as per item No 120 here in above, but of capacity 60/50 HP all as specified and directed.
All as per item No 120 here in above, but of capacity 15 HP all as specified and directed.
Overhauling of Fire fighting pump, electric driven complete pumpset of 3 Phase, 415 volt, of any size/ capacity by cleaning, varnishing, heating, assembling, refixing in position and pump side replacing of stainless steel sleeve, gland packing, greasing etc and testing complete all as specified and as directed.
Disconnecting suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump from motor and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work all as specified and directed at site of capacity 70/75 HP
All as per item No 124 here in above, but of capacity 60 / 50 HP all as specified and directed.
All as per item No 124 here in above, but of capacity 15 HP all as specified and directed.
Disconnecting the three phase electric supply from panel board and taking out the burned wiring of panel board and unserviceable spare part like contactor ,relays, timer , push button, NO/NC volts coil and thermal load relays etc and re-wring the panel board with new required size of wire and accessories which be required to make 100 % serviceability suitable for starter panel for pump sets complete all as specified and as directed
M&L for painting to outer side of the existing fire fighting , pipe lines by two coat of synthetic enameled paint (1st grade quality) of existing colour by using spray gun and compressor after making the surface ready to paint , complete all as specified and directed. Make : Asian Paints / Shalimar / Nerolac / Berger Paints
M&L, for repair / replacement of worn out gland packing of pump set / sluice valves / hydrants any make / metal / size including washers of any shape / size to avoid water leakage as indicated including taking out old one complete all as specified and directed.
M&L for cleaning strainer of size of 3 metre long X 0.40 metre dia fabricated with aluminium strainer to suction line having 1200 holes to the strainer of suction line includes dismantling the suction line and lifting it , cleaning the foot valve , scrubbing the complete strainer including 1200 holes with suitable liquid properly and then lowering back for re fixing the strainer into water with MS angle arms and 02 hooks provided to the strainer for lifting/ lowering the strainer to the suction line and to the pump set along with foot valve inside the lowered strainer complete all as specified and directed.
M&L for cleaning of foot valve of size 80 mm to 150 mm in any condition including dismantling the suction line and lifting it and lowering back after cleaning the foot valve complete all as specified and directed.
M & L for Aqueous Film Forming Foam (AFFF) liquid including cleaning of metal container and nozzle etc complete all as specified and directed. Note: An amount of Rs.26625.00 on account of credit schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S SARDAR MAL NAHATA
BHARAT ELECTRIC
M/S ROY ENTERPRISE
M/S BISHAL ENTERPRISES
Shri T P ANIL KUMAR
M/S RATHIN ENTERPRISES
M/S. NARENDRA KUMAR GARG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .