Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC NEAR SOLAPOKHARI PO INS CHILKA DIST KHURDA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being L1 and rate is acceptable | |
| 2 | L2₹2.0 L+₹9,489 (4.88%)Rejected-Finance PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L2 | Rejected-Finance Being L2 | |
| 3 | Rejected-Technical JANUGANJ REMUNA GOLAI BALASORE 756 019 ODISHA | BALESHWAR | ODISHA | 756019 | - | Rejected-Technical Technically rejected for non submission of MES enlistment |
Tender Value
₹1.8 L
Closing Date
20 Sept 2024, 10:40 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Himanshu, IDSE EE
GE (I) (CG) Bhubaneswar Military Engineer Service Kokila Residency 2nd floor Ananta Vihar Pokhariput Bhubaneswar 751020
Repair and maintenance of split type AC and connected works at CGAE Bhubaneswar under GE (I) (CG) Bhubaneswar
2024_MES_672291_1
EQTN/2024-25/06/E3
Open Tender
Electrical and Maintenance Works
Works
30 days
CGAE Bhubaneswar
MES Enlistment letter
2 documents required · 2 mandatory
₹0
Exempted
3 Oct 2024
6 Sept 2024
21 Sept 2024
6 Sept 2024
20 Sept 2024
6 Sept 2024
6 Sept 2024 - 13 Sept 2024
Amount
Schedule "A" Part – I to Schedule "A" Part – XVII: NOTE: Schedule "A" Part – I to Part – XIV EXCEPT Schedule "A" Part –IIA , Schedule "A" Part – XV, Schedule "A" Part –XVI and Schedule "A" Part –XVII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only Contractor shall insert their rates for Schedule "A" Part –IIA Schedule "A" Part – XV, Schedule "A" Part –XVI and Schedule "A" Part –XVII under Green coloured field under Column - 6 only
Dismantling of Split type Air Conditioner, of any capacity & 'make', opening up for servicing, inspection / examination for serviceability of compressor, fan, motor, relays,PCB of indoor and outdoor units, capacitors, cleaning the evaporator and condenser with compressed air/ water as required, lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips, unserviceable wiring, rubber mounting for compressor including all minor spare parts for carrying out servicing including reassembling & testing of AC, complete all as directed
Supply and replacement of hermetically sealed Rotary type compressor of 1.5 TR capacity for split type AC of existing make and model with new compressors and assembling testing the same with replacement of necessary drier and capillary tube complete all as directed by Engineer-in-Charge including taking down.(Make : Kirloskar/Hitachi/Voltas/ as per site requirement)
All as above item No- 02 but 2.0 TR Split type Room Air Conditioner compressor including taking down. (Make : Kirloskar/Hitachi/Voltas/ as per site requirement)
Taking out Condensing Fan motor of Split type AC of 1.5 TR capacity from its existing base and dismantling the same and rewinding the burnt out winding with super enameled copper conductor with existing gauge and size of conductor and varnishing all insulating materials including making necessary heat treatment complete all as directed by Engineer-in-charge.
All as per above item No-06 but of condensing fan motor of split type AC of 2.0/3.0 TR capacity.
All as per above item No- 06 but of Blower motor of Split type AC of 1.5/ 2.0 capacity.
Supply and replacement of unserviceable Fan motor of condensing Unit of STAC with new motor suitable for STAC of 1.5 TR capacity as per existing suitable capacity including taking down old one. (Make: GE/Crompton Greaves or equivalent as approved)
Supply and replacement of unserviceable Fan motor of condensing Unit of STAC with new motor suitable for STAC of 2.0 TR capacityas per existing suitable capacity including taking down old one. (Make: GE/Crompton Greaves or equivalent as approved)
Supply and replacement of unserviceable Blower motor of indoor unit of split AC of 1.5/2.0 TR / Ccondensing fan motor of Water cooler with new motor of split type AC/ Water cooler of any make and capacity as per existing suitable capacity including taking down old one.Make: GE/Crompton Greaves or equivalent as approved)
All as Per Item No 12 above but for R-410 gas for Split AC of various capacity after leak test,Make :- Mafron/Floron.
All as Per Item No 12 above but for R- 32 gas for Split AC of various capacity after leak test,Make :- Mafron/Floron.
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 2.5 MFD, + 5% for fan motor of water cooler and airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 6 MFD, + 5% for Split type airconditioners Outdoor Fan motors..Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 8 MFD,+ 5%, 4 pin for Split type airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 50+6 MFD, + 5%, 7 pin PSC system for Airconditioners.Make: BCON/SARDA/UNIVERSAL
Supply and replacement of printed circuit board (PCB) with display board,sensor and remote control for Outdoor Units of Split type AC of 1.5 TR capacity all as per existing type and make including taking down. (Make of existing AC : LG / Hitachi/Voltas).
Supply and replacement of printed circuit board (PCB) with display board,sensor and remote control for Outdoor Units of Split type AC of 2.0 TR capacity all as per existing type and make including taking down. (Make of existing AC : LG / Hitachi/Voltas).
Supply and replacement of printed circuit board (PCB) with display board,sensor and remote control for Indoor Units of Split type AC of 1.5 TR capacity (Inverator Model, 5 Star ) all as per existing type and make including taking down. (Make of existing AC : LG / Hitachi/Voltas).
Supply and replacement of printed circuit board (PCB) with display board,sensor and remote control for Indoor Units of Split type AC of 2.0 TR capacity (Inverator Model, 5 Star ) all as per existing type and make including taking down. (Make of existing AC : LG / Hitachi/Voltas).
Supply and replacement of printed circuit board (PCB) with display board,sensor and remote control for Outdoor Units of Split type AC of 1.5 TR capacity (Inverator Model, 5 Star ) all as per existing type and make including taking down. (Make of existing AC : LG / Hitachi/Voltas).
Taking down carefully indoor & Outdoor AC units from the wall/outside of window by disconnecting copper pipe, electrical connections and re fixing at another building as directed, including making hole on wall and using extra copper pipes, cables, cleaning and servicing the AC units complete with charging of gas if any required for working all as specified and as directed by Engr-in-Charge. Note: Cost includes of all T&P required to remove outdoor unit from existing fourth / fifth floor window and providing new stand at new location for outdoor unit
Supply & fix in replacement insulation(nitrile insulated) of copper pipe of dia 10-30mm for covering the damaged insulation on existing copper pipe of heating plant all as specified and directed.
Supply & Fix in replacement copper pipe of I/D 12.7mm and thickness 22mm all as per specified and directed.
SMART ENERGY SOLUTIONS (BID ID -3092644)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .