Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹26.5 L+₹6.3 L (30.9%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L2 | Rejected-Finance Being other than L1 Bidder | |
| 3 | L3₹28.3 L+₹8.1 L (39.8%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Being other than L1 Bidder | |
| 4 | L4₹28.6 L+₹8.3 L (41.1%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L4 | Rejected-Finance Being other than L1 Bidder | |
| 5 | L5₹32.0 L+₹11.7 L (57.9%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 Bidder |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
2 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINT OF LT DISTRIBUTION PANELS AND CABLE INCLUDING CONNECTED WORKS AT SECTOR B UNDER AGE EM II OF GE 865 EWS
2023_MES_589247_2
865/EWS(NIT-47)/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹88,000
Yes
24 Jul 2023
12 May 2023
9 Jun 2023
12 May 2023
2 Jun 2023
20 May 2023
Amount
Material and labour for fixing and installation over head aluminium conductor steel reinforced weasel including making connections and fixing on existing poles including binding with insulators and necessary arrangements including dismantling old ACSR or AAC conductors complete all as specified and directed. Note:- Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring straight horizontal distance between centre to centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers, etc complete all as specified and directed by Engr-in-Charge.
Material and labour for fixing cross arms bracing supports clamps, back plates fabricated from steel section made out of Fe-410 structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminum paint over one primer coat, including dismantling cross arms of MS channel or angle section complete all as specified and directed by Engr-in-Charge.
Material and labour for fixing stay assembly complete with stay plate bow, stay rod of dia 16 mm and gavanised iron stay wire stranded of size 7/4mm and accessories as shown in electric plate No 1 of SSR Part-I (loop type insulator, stay clamps, excavation and concrete shall be measured separately) including dismantling old stay assembly complete all as specified and directed by Engr-in-Charge.
Excavating in trenches not exceeding 1.5 m wide and not exc. 1.5 mtr in depth for laying of cables n.exc 10 Sqm on plan and getting out hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning filling, spreading, levelling , watering and well ramming in layers not exc 25 cm complete all as specified by Engr-in-Charge .
Removing excavated material not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and spreading sand for cushioning of electric cable 8 cm below cable and 15 cm above cable including watering and well ramming in layer complete as specified in clause 19.75 of SSR part-I complete all as specified by Engr-in-Charge. Note: Punned thickness shall be measured and paid.
Supply and laid of factory made, machine pressed, Un-reinforced, precast concrete cable cover class LV type-1 flat size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-Charge.
Supplyand fixing cable route indicator made out of cast iron and embedded LT cable on the plate of size 80 mm dia and 5 mm thick, grouting luggs with PCC 1:2:4 in size of 150 x150 x 150 mm including excavation and making good surfaces complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of indicator lamp LED type (Red, Yellow, Green) moulded single piece suitable for LT panels complete all as specified and directed by Engr-in-Charge.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 16 sqmm 2 core complete all as specified and as directed by Engr-in-Charge. Note: Clamps, GI pipes, excavation , earth work, sand cushioning and PCC protection cover shall be measured and paid separately.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 16 sqmm 4 core complete all as specified and as directed by Engr-in-Charge. Note: Clamps, GI pipes, excavation , earth work, sand cushioning and PCC protection cover shall be measured and paid separately.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 25 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Note: Clamps, GI pipes, excavation , earth work, sand cushioning and PCC protection cover shall be measured and paid separately.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 35 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Note: Clamps, GI pipes, excavation , earth work, sand cushioning and PCC protection cover shall be measured and paid separately.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 50 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Note: Clamps, GI pipes, excavation , earth work, sand cushioning and PCC protection cover shall be measured and paid separately.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 70 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Note: Clamps, GI pipes, excavation , earth work, sand cushioning and PCC protection cover shall be measured and paid separately.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 120 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Note: Clamps, GI pipes, excavation , earth work, sand cushioning and PCC protection cover shall be measured and paid separately.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 240 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Note: Clamps, GI pipes, excavation , earth work, sand cushioning and PCC protection cover shall be measured and paid separately.
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including dismantling taking down old broken LT danger notice plate of any size complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 630 Amps current carrying capacity 50 KA, 3 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 630 Amps current carrying capacity 50 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 500 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 400 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 350 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Material and labour for painting of LT panels including cleaning of exposed surface with brush and emery paper including painting with smoke grey paint complete all as directed of any size of LT panels complete all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old steel surface and applying two coats of synthetic enamel white paint to LT steel tubular/PCC pole upto 1 metre height from ground level alternative in yellow and black colour or white and black strips of 30cm height each including numbering of Pole No with black paint complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement tubes light grade of size 80 mm bore mild steel galvanised with all fittings and fixed complete to walls/poles or laid in floor/roads complete all as specified and as directed by Engr-in-Charge.
Supply and laying in replacement tubes light grade of size 50 mm bore mild steel galvanised with all fittings and fixed complete to walls/poles or laid in floor/roads complete all as specified and as directed by Engr-in-Charge.
Supply and laying in replacement tubes light grade of size 40 mm bore mild steel galvanised with all fittings and fixed complete to walls/poles or laid in floor/roads complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of Pin type, porcelin, vitreous, white, brown or green insulator, including one galvanised iron steel spindle,two galvanised iron washer and one galvanised ion nut, working pressure 1100 volts grade and of size 65mm dia and 100 mm height ISI marked, conforming to IS: 7321-1931, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of shackle type insulator, porcelain, vitreous, white, brown or green insulator, including one galvanised iron steel spindle, two galvanised iron washer and one galvanised ion nut, working pressure 1100 volts grade and of size 115mm dia and 100 mm height ISI marked, conforming to IS: 7321-1931, complete all as specified and as directed by Engr-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below ground level connected to and including GI strip 32x6 mm as earthing leads by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 40mm bore light grade GI watering pipe, lugs, 20mm bore light grade GI protection pipe, test point etc including taking out of old u/s earthing set, complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order (iii) Item includes the cost of Charcoal and commercial salt
M&L for GI earthing strip of size 25x4mm on PVC/porcelain insulators at suitable distance with saddless and fixing screws for roof/wall conductors and down conductors above ground all joints of GI strip should be brazed properly and directed by Engineer-in-Charge.
Material and labour for synthetic insulating matt for Electrical instrument of size 2M x 1M x 10 mm thick complete all as specified and directed by Engr-in-Charge,
Supply and fix in replacement of PVC Spacer 2/4 way for LT over head line 1100 Volt with necessary nut and bolts etc complete all as specified and directed prevent the line touching each other on heavy wind as a preventive arrangement to the existing system including removing the existing old/out lived spacers and directed by Engr-in-Charge.
Supply and replacement of ON Load Change over (front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 1000 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of ON Load Change over (front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 630 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of ON Load Change over (front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 400 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of ON Load Change over (front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 125 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : : As per PS
Supply and replacement of ON Load Change over (front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 63 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : : As per PS
Supply and fixing in replacement of aluminum thimble of size 35/50/70/95 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of aluminum thimble of size 120/150/185/240/300/400 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and replacement of ON Load Change over (Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 63 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : : As per PS
Supply and replacement of ON Load Change over (Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 125 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 125 Amps with connecting acessories complete all as specified and directed by Engr in Charge. : Make : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 200 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make :As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 320 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 400 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 630 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 1000 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and fix in replacement of MCCB 63 Amps, 415 V, 4 pole of rupturing capacity 25 KA complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 100 Amps, 415 V, 4 pole of rupturing capacity 16 KA complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 125 Amps, 415 V, 4 pole of rupturing capacity 16 KA complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 160 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 200 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Material and labour for Plain cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in base for foundation complete all as specified and directed by Engr-in-Charge.
Material and labour for plain Cement concrete in filling and mass concrete/ Coping of Poles and PCC for road crossings etc all as directed , type C-1, Type 1:3:6 (using 20 mm graded crushed stone aggregate) in CM 1: 4 complete all as specified and directed by Engr-in-Charge.
Horizon Construction Company
national engineering
SUMEET TRADING CORPORATION
M/S NINDI BUILDERS
M/S TRADE LINK
HEENA CONSTRUCTION CO
M/S NANCY ENTERPRISES
M/S NISSAR ALI
BETONG BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .