Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.4 LAccepted-AOC AT SAWANG GOMIA BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | 1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical KATHARA DIST BOKARO 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Not evaluated as not L1 | |
| 3 | Rejected-Technical AT PO JARANGDIH BOKARO | JARANGDIH | BOKARO | JHARKHAND | - | Rejected-Technical Not evaluated as not L1 |
Tender Value
Refer Docs
EMD Value
₹4,400
Closing Date
9 Oct 2023, 4:00 pmClosed
Staff officer ENM
Office of the staff officer EnM kathara Area
electrical repairing / rewiring of Staff recreation Club with main power supply, cable, G.I. earth pit and providing of LED panel light under Kathara Area
2023_CCL_289642_1
GMKTA/SOEnM/E-tender/23-24/20
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Kathara Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,400
1 Dec 2023
26 Sept 2023
10 Oct 2023
27 Sept 2023
9 Oct 2023
27 Sept 2023
27 Sept 2023 - 5 Oct 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. - Group C cost for -1
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required :2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required::2 X 4 sq. mm + 1 X 4 sq. mm earth wire .
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. : 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. : 15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral .
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Deleted.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. Cost for Each.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200 mm X 250 mm X 60 mm deep .
Providing of 10sq.mm 4 core copper cable (armoured).
Providing of ICTP Switch 100 Anps 415V.
Providing of change over Switch 200 Amnps 415V.
Providing of LED surface ceiling light squaire type (2x2)36 watts 220V etc.
Providing of LED surface ceiling light circular type(18 wattx)220V) etc.
Labour charges for items no.20 to 24
Total impact of GST for the purpose of CTC
M/S TIGER ENTERPRISES
M/S JAY GURU CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_299976.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .