Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹30.8 L+₹1.7 L (5.81%)Rejected-Finance VILLAGE SHAHBAJPUR KHALSA PO MAJRA GURDAS 123401 | REWARI | REWARI | HARYANA | 123401 | L2 | Rejected-Finance OK |
Tender Value
₹23.4 L
EMD Value
₹46,800
Closing Date
10 Jan 2020, 5:00 pmClosed
EXECUTIVE ENGINEER
ccshau hisar
Conversion of existing two rooms into cafeteria in the vicinity of Museum and University press in the premises of Gandhi Bhawan at CCSHAU Hisar
2019_HRY_114072_1
3132
Open Tender
Civil Works
Works
90 days
CCSHAU
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Executive Engineer E
₹46,800
5 May 2020
28 Dec 2019
13 Jan 2020
28 Dec 2019
10 Jan 2020
28 Dec 2019
Amount
Civil items( 1 to 53):- Loading , unloading for sand /earth/ building rubbish (HSR 4.1)
Disposal/ carriage of material / building rubbish ( metalled road) with a lead of 2 K.M. excluding loading, unloading (HSR 5.2(a)}
Earth work in excavation in foundations, trenches, etc .in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches ,stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres {HSR 6.6}
Dismantling brick work, tile masonry or tile lining and tile terracing (b) in cement (HSR 8.5(b))
Dismantling concrete (e) reinforced cement concrete with cleaning and straightening and cutting of bars if required {HSR 8.6 (e)}
Removing doors and windows (wooden and steel) together with the dismantling of walls :- (a ) Doors {HSR 8.17(a)}
Removing door and windows (wood and steel) with chowkats by making recesses in walls when the wall is not to be dismantled doors.{HSR 8.18(a)}
Removing door and windows (wood and steel) with chowkats by making recesses in walls when the wall is not to be dismantled windows{HSR 8.18(b)}
Dismantling cement conglomerate/ terrazzo floors 25mm to 50mm thick including concrete base.{HSR 8.25}
Scraping (a) White wash and colour wash (HSR 8.32 (a))
Scraping (c) Cement plaster (HSR 8.32 (c))
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth. (HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth (HSR 10.41)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects. (HSR 10.81)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects.(HSR 10.86)
Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 (HSR 10.95 (a))
Providing and laying 60 mm thick interlocking paver blocks of all shapes and colours in design mix cement M-35 over a bed of 25 mm thick fine sand complete in all respects(HSR 10.158)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth{HSR 11.2}
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR 11.7)
11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure (HSR 11.48(a)
11.43 cm thick brick wall with every fourth course reinforced with hoop-iron laid in 1:4 cement stone dust (from crusher) mortar in superstructure {HSR 11.51}
11.43 cm thick brick wall laid in cement stone dust (from crusher) mortar 1:4 without reinforcement in foundation and plinth. (HSR 11.52)
Providing and fixing false ceiling with 12 mm thick Gypsum Board fixed on M.S. steel runners frame including cost of screws angles, cleats, rawel plugs with taping, filling with Gypsum compound and applying priming coat etc. complete in all respects (HSR 13.91)
Providing and fixing mineral fibre false ceilings tiles at all hieghts of size 595 x 595 mm of approved texture, design and pattern, the tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity K = 0.052 (-) 0.057 w/m k, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round gavanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 35 mm of length 3000 mm, cross T of size 600 x 600 mm suspended from celing using galvazied mild steel item (galvanizedd @ 80 gsm) 50 mm long 8 mm outerdiameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, spaced at 1200 mm centre of centre along main 'T'. The suystem should rest on periphery walls/partitions with the heop of GI perimeter wall angle of wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all hieghts, The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge. with or without groves (HSR 13.92)
Providing and laying average 6 mm thick POP coating on walls, ceiling, beams and lintels etc., complete in all respects as approved by the Engineer-in-Charge (HSR 13.94)
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling (HSR 14.1)
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4)
12 mm thick cement plaster 1:6 on walls(HSR 15.7}
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall {HSR 15.12}
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25}
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57}
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). {HSR 16.81}
Providing and fixing Aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS;733 and IS; 1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. aluminium sections shall be smooth rust free straight mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling C.P. brass/ stainless steel screws, all complete. Fixed portion (Anodized Aluminium transparent or dyed to required shade according to IS;1868, minimum anodic coating of grade AC 15) (HSR 17.95)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS; 733 and IS;1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. Aluminium sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including clear angle, Aluminium snap beading for glazing/ paneling C.P. brass/ stainless steel screws, etc. complete. (HSR 17.96) Shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including of cost of PVC/ neoprene gasket required including Aluminium fitting. (HSR 17.96)
Providing and fixing glazing in aluminium door, windows, ventilator shutter and partitions etc. with PVC/ neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basic items) (b) With float glass panes of 5.00 mm thickness..(HSR 17.98 (b))
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS; 6315 marked for doors including cost of cutting floors as required embedding in floors and cover plats with brass pivot and single piece M.S. sheet outer box. (a) With Stainless Steel cover plate. {HSR 17.99 (a)}
Providing fixing aluminium round shape handle of outer dia 100 mm with screws etc. complete. (i) Anodized (AC-15) Aluminium. {HSR 17.102 (i)}
Supplying and fixing rolling shutters, of approved make, M.S. Laths , interlocked together through their entire length, and jointed together, at the end, by end locks mounted on specially designed pipe shaft, with brackets, side guides, 27.5 cm long wire spring grade no.2 , and arrangement for inside and out side locking , with push and pull operation complete, including top cover 0.80 mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed):- (b) with 80 mm X 1.25 mm M.S. Laths {HSR 18.18 (b)}
Fe-500 D TMT steel bars for R.C.C., works, where not included in the complete rate of R.C.C. , including bending ,binding and placing in position complete {HSR 18.22}
Providing & fixing vitrified tiles of size 800 mm x 800 mm of double charged quality of approved make in flooring laid in any patterns as specified over base of 20 mm thick cement coarse cement mortar 1:3 and jointed by using PVC speciars of required size and space between tiles shall be filled up with cement based grout of approved make and colour, complete. (NS)
Providing & fixing vitrified tiles of size 800 mm x 800 mm of double charged quality of approved make in skirting/ dado laid in any patterns as specified over base of 12 mm thick cement coarse cement mortar 1:3 and jointed by using PVC spacer of required size and space between tiles shall be filled up with cement based grout of approved make and colour, complete. (NS)
Providing & fixing 4 mm thick aluminium composite panel (ACP) fixed over frame made of aluminium sections (excluding cost of aluminium section frame) of size 50 mm x 25 mm including cost of cutting nails, screws, sealent, tape, rawl plugs etc., complete in all respect as directed by Engineer-in-charge. (NS)
Providing and fixing stainless steel railing of 304 grade consisting of stainless steel tube of size 65mm x 35mm as hand rail, 25mm x 25mm internal horizontal members, 40mm x 40mm internal vertical members including cutting, welding, grinding, buffering etc. complete in all respect.as directed by Engineer-in-charge. (NS)
Providing and laying 15 mm to 18 mm thick Z-black Granite stone (Polished) on work top/steps including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade, complete in all respect as per drawing and design.(NS)
Chamfering of granite stone fixed on worktop/steps to required shape, complete in all respects as directed by Engineer-in-Charge. (NS)
Providing & fixing vitrified tiles of size 400 mm x 400 mm x 14 mm thick of approved make in flooring laid in any patterns as specified over base of 20 mm thick cement coarse cement mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles, complete. (NS)
20 mm thick cement plaster 1:3 at all height in two coats under ceiling, 1st layer of 10 mm thick with cement coarse sand 1:3 (1 cement : 3 coarse sand) & 2nd layer of 10 mm thick cement sand plaster 1:3 (1 cement : 3 fine sand) complete in all respect as directed by the Engineer-in-Charge.(NS)
Providing and applying two coats of Dr. Fixit Pidicrete URP-SBR Latex (Pidilite make) solution made of URP + cement in the proportion of 1:1½ (as recommended by the manufacturer) on deteriorated concrete surfaces of slab, beams and columns, complete in all respects as directed by the Engineer-in-Charge.(NS)
Providing and fixing factory manufactured cement conc. Kerbs of size 1’-0”x1’-0” x 0’-6” with rounded edge on front side, fixed at ground level along with road/ cement concrete pavements, complete in all respects but excluding cement pointing.(NS)
Providing and fixing fully glazed frameless double leaf glass door shutter made out of 12 mm thick toughened glass of approved brand and manufacture. The glass shall be fitted with PATCH FITTINGS assembly/accessories i/c floor spring, locking arrangement & all other necessories fittings/accessories (DORMA MAKE). the work shall be executed has directed by Engineer-In charge. Cost includes all type of material, making necessary holes/cutts and labour etc. complete. (NS)
Providing and fixing wooden wall cabinet of size 2'-9" hight and 1'-6" deep consisting of following :- (i) 19 mm thick BWR grade -II block board (ISI mark) of approved make having three horizontal pices ( one at top, one at centre and one at bottan at equal distance) and vertical partitions @ 2 feet c/c to create 10 compartments. out of 10 compartments, 6 compartments covered with double leaf shutters of BWR grade-II block board. (ii) 1 mm thick plastic laminate sheet (ISI mark) of approved make (Green, Century, Duro) shade and colour on all visible faces except back of cabinet. (iii) 6 mm thickk BWR grade -II plywood (ISI mark) of approved make on back side of cabinet. Including cost of cutting, gutties, rawl plugs, nails, screws, adhesive and petty items etc. fixed in position, complete in all respect architectural drawing and design or as directed by Engineer In-charge.(NS)
Manufacturing and supplying display cabinet of size 3'-0" wide, 1'-6" deep and 6'-6" heigh consisting of following:- (i) 19 mm thick BWR grade -II block board (ISI mark) of approved make for back, sides, top and bottam. (ii) 1 mm thick plastic laminate sheet (ISI mark) of approved make (Green, Century, Duro) shade and colour on all visible faces of cabinet. (iii) 8 mm thick toughend glass shutters on front side of cabinet with 2 Nos. stainless steel pivot (one at top and one at bottam) of required size. (iv) 65 mm wide and 35 mm thick wooden frame of teak wood at top and bottam of front side. (v) 3 Nos. partitions in side the cabinet of 10 mm thick toughend glass placing on adjustable system. Incluidng cost of cutting, nails, screws, fevicol, push catcher, petty items etc. complete in all respect as per archatectural drawing or as directed by Engineer- in-charge. (NS)
PH items( 54 to 67):- Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. {HSR 28.18(b)} INCLUDING COST OF SPECIALS (i) 15 mm internal diameter of pipe line
(vi) 50 mm internal diameter of pipe line
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. {HSR 28.21} (a) 15 mm internal diameter
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. (HSR 28.24) (b) 22.86 cm thickness of walls
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. {HSR 28.29} (a) 15 mm internal diameter
Making connection with the existing G.I branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site {HSR 28.34)
Providing and fixing 40mm G.I waste pipe embedded in walls or lead waste pipe weighing 4.46 kg/ metre and 3.0 mm thick up to floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62)
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm X 150 mm cast iron cover weighing approximately 7.26 kg. and frame clear opening 300 mm X 300 mm and outside size 330 mm X 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:8:16 in foundations, and cement concrete 1:2:4 in coping around C.I. cover and frame et. With three coats of black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm. (HSR 30.114)
Supply of PVC pipe 6 kg/cm² pressure of ISI marked of Prince / Supreme make (NS) a) 63 mm o/dia (2” i/dia) size
Supply and fixing in position stainless steel sink made of 1 mm thick Salem stainless steel sheet along with fittings of Blue Star/ Jayna make as per AISI 304 (18/8), complete in all respect. (NS) Bowl size = 560 mm x 405 mm x 178 mm Overall size = 610 mm x 460 mm x 178 mm
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (NS) (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1450 cum/ hr. (iii) Sound level (H/M/L)- 41/38/34/25(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Toshiba/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge ofV-Guard make ISI marked complete in all respect. (N.S.)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
Electrical items (68 to 99):- S/E of MCBs/isolator 240/415 V in existing distribution board including making necessary connections :-( HSR 31.17 ) 6 to 32 amp. MCB SP
40 to 63 amp. MCB TPN
Supply and erection of PVC pipe of 6Kg pressure laid in 1 mtr below ground level complete i/c digging refilling of the trench with jointing etc.( HSR 31.21 ) {(xxx) (b)} PVC Pipe 80mm dia
Earthing with GI earth pipe 4.5 mtr long and 40 mm dia with masonry enclosures on the top etc as required.
Extra for using salt and charcoal coke for pipe earth electrode as required
Pdg. & laying earth connections from earth electrode with 4.00mm dia GI wire in 15mm dia GI pipe from earth electrode as required.
Pdg. & laying earth connections from earth electrode with 4.00mm dia GI wire on surface from earth electrode as required.
S/E of underground cable 1 mtr below ground level with sand & bricks covered , digging , refiiling etc.loose in existing pipe or trenches complete with necessary connectons :-( HSR 31.25 ) (xxviii) 70sqmm 3.5 Core Cable
S/E of underground cable loose in existing pipe & trench complete with necessary connectons :-( HSR 31.26 ) (xxvii) 70sqmm 3.5 Core Cable (Unarmound)
S/E of suitabl;e compression type brass cable glands for under ground cable ( HSR 31.28) (iv) 70sqmm to 95sqmm cable 3 to 3.5 core
S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.( HSR 31.40 ) Cable Size 1.5 sqmm (3/0.81)
Cable Size 2.5 sqmm (3/1.05)
Cable Size 4 sqmm (7/1.35)
Cable Size 6 sqmm
S/E of double door sheet steel enclosure d/B suitable for MCB and ELCB etc recessed in wall i/c bonding to earth with all labour and material required to complete the job in all respect upto to the entire satisfaction of EIC.( HSR 31.41 ) (ix) 4 Way TP&N ( Vertical) 8+12
S/E of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect. ( HSR 31.44 ) (b) 25 mm dia
S/E of copper lugs including crimping etc. upto the entire satisfaction of Engineer-in-charge of work.( HSR 31.45 ) (b) 4 sqmm to 6 sqmm
Pdg. & fixing modular type accessoriesm of app. Make in existing box including fixing and making necessary connections complete in all respect.( HSR 31.56 ) 10 amp. 1 way switch
20 amp. Switch
10 amp. Socket
16 amp. Socket
Fan Regulator
Blinking plate
Pdg & fixig GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate with all labour and matrial required for the job.(HSR 31.57) 3 Modules
6 Modules
12 Modules
S/E of MCCB Single Pole / 4 Pole on wall on existing pedestal i/c bonding to earth and making necessary connections required to complete the job EIC ( HSR 31.69) (vi) 4 Pole MCCB 200Amp
S/E of recessed type 42 watt full window glare free opal difffuse LED panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 4600 or above in cool day light (5600k to 6500k), Power factor >0.95, CRI (Ra) >80, LED lamp efficiency ≥140 lm/w, Average life >50000hours, complete with all accessories as required with connections. (Industrial) (NS) Make: Philips, Havells, Wipro, Bajaj
S/E of AC ceiling fan capacitor type complete with shackle, 300 mm down rod and regulator etc. with rating 5 star. 1400 mm sweep.(NS) Make: Usha, Orient, Crompton
S/E of propeller type AC ventilating fans (exhaust fan 12" sweep) with necessary earthing of fan complete with louver shutter, 300mm sweep (Heavy duty) (NS) Make: Philips, Orient, Cromption
SITC iof push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to complete the job upto entire satisfaction of Engineer-in-charge. (NS) Make: Schneider/Crabtree/Athena
NAVEEN KUMAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .