Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹49.5 L+₹2.7 L (5.78%)Rejected-Finance K B ROAD WARD NO 11 NORTH LAKHIMPUR PIN 787001 ASSAM | LAKHIMPUR | ASSAM | 787001 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹50.5 L+₹3.7 L (7.90%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹51.0 L+₹4.2 L (9.04%)Rejected-Finance AT ROAD TINSUKIA HIJUGURI BASH BARI P O HIJUGURI DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹52.0 L+₹5.2 L (11.1%)Rejected-Finance BORBARUAH BAZAR A T ROAD DIBRUGARH ASSAM | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹45.2 L
EMD Value
₹90,400
Closing Date
19 Jun 2024, 6:00 pmClosed
GE 872 EWS
GE 872 EWS, C/O 99 APO
REPAIR / MAINT TO INTERNAL ELECTRIFICATION, REPAIR/ MAINTENANCE/ SERVICING TO VARIOUS TYPE OF FANS AND REPAIR/ MAINTENANCE/ SERVING TO COOLING APPLIANCES AT LIKABALI MIL STN UNDER GE 872 EWS
2024_MES_651747_2
8582/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LIKABALI
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹90,400
Yes
2 Sept 2024
11 Jun 2024
21 Jun 2024
11 Jun 2024
19 Jun 2024
13 Jun 2024
11 Jun 2024 - 12 Jun 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 04 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
S & F Switch socket combination 2 in1, 3 pin, 6 Amp, flush type, universal complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in 1, 3 pin, 6 Amp, flush type, universal complete all as specified and as directed.
S & F Switch socket combination 5 in 1, 6 and 16Amp, flush type, universal complete all as specified and as directed.
S & F in repairs Switch socket combination 5 in 1, 6 and 16 Amp, flush type, universal complete all as specified and as directed.
S & F bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
S & F Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S & F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
S & F in repairs Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs modular bell push 6 amp 240 volts1 module,complete all as specified and as directed.
S & F in repairs stepped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed.
S & F in repair madular Switch socket Combination 16A, 6 pin, 3 module complete all as specified and directed
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of casing capping shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of casin capping shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casin capping of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casin capping shall be measured as one length)
S & F in repair Rigid non-metalic PVC casing capping of size 25mm inclusive of all fittings and fixing accessories complete all as specified and directed.
S & F in repair Rigid non-metalic PVC casing capping of size 32mm inclusive of all fittings and fixing accessories complete all as specified and directed.
S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed.
S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed.
S & F LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI > 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LBLK02X010XC or equivelant of make as per list of manufacturer)
S & F in repairs LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI > 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LBLK02X010XC or equivelant of make as per list of manufacturer)
S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer)
S & F in repair LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer)
S & F in repairs LED tube rod, T8, 20 Watt, polycarbonate diffuser, 1200mm length, CCT: WW/CW complete all as specified and directed. (Make: Jaquar Cat No. LTBL01X020XC or equivelant of make as per list of manufacturer)
S & F in repairs LED Bulb, 12 Watts, B-22 Lumen ≥ 1200, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
S & F Surface and wall mounted LED batten, 10W, 220V, AC, 2 feet, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% including lamp, fixing accessories and connecting up complete all as specified and directed. (Make : Havell's Cat No. ENDURALINEARNEOBS10WLED865SPCWH and equivelant model of make as specified in list of manufacturer).
S & F in repair Surface and wall mounted LED batten, 10W, 220V, AC, 2 feet, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% including lamp, fixing accessories and connecting up complete all as specified and directed. (Make : Havell's Cat No. ENDURALINEARNEOBS10WLED865SPCWH and equivelant model of make as specified in list of manufacturer).
S & F LED downlight, Recess mounted round/square, die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R012XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R012XC or equivelant of make as per list of manufacturer)
S & F 2x2 recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)
S & F in repair 2x2 recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)
S & F in repairs LED Driver 24 to 36/40 watts as per site requirement complete all as specified and as directed.
S & F 15 Watt Focus light, Colour Temp 4000K, warm white colour with all accessories including lamp, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Phillips 'Miranda' or equivelant of make as per list of manufacturer)
S & F in repair 15 Watt Focus light, Colour Temp 4000K, warm white colour with all accessories including lamp, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Phillips 'Miranda' or equivelant of make as per list of manufacturer)
S & F sheet metal enclosure, single door MCB DBs, phosphatised, powder coated, Single pole & neutral (SPN), 02 way, 240 Volts suitable for housing MCBs with din rail, neutral and earth bar in proper psoition complete all as specified and directed.
S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection complete all as specified and as directed. (Make: Havell's cat part No. DHDNSHODAW04 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDNTHCDRW04 or equivalent make as per List of Manufacturer's)
S & F MCB, TPN 40-63 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed (Make : Havell's Cat part No. DHMGCTNF040 to 63 or equivelant of make as perList of manufacturer's)
S & F in repair MCB, TPN 40-63 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed (Make : Havell's Cat part No. DHMGCTNF040 to 63 or equivelant of make as perList of manufacturer's)
S & F MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer's)
S & F in repairs MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer's)
S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
S & F MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Legrand cat part No. 4086 14 to 17 or equivalent make as per List of Manufacturer's)
S & F in repair MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Legrand cat part No. 4086 14 to 17 or equivalent make as per List of Manufacturer's)
S & F MCB SP 40 Amps, 240 Volts, 10KA, B Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGBSPF040 or equivalent make as per List of Manufacturer's)
S & F in repair MCB SP 40 Amps, 240 Volts, 10KA, B Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGBSPF040 or equivalent make as per List of Manufacturer's)
S & F 1100 volts grade, heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, cross sectional area 4 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed.
S & F 1100 volts grade, heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, cross sectional area 6 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed.
S & F 1100 volts grade, heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, cross ectional area 10 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed.
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc complete complete all as specified and directed. (Note : (i) Spare parts shall be measured and paid seperately as supply only and rewinding of fan shall be measured and paid seperatly under relevant item here-in-below. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed withing one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor's workshop and fan shall be re-fixed at site withing 10 days after taking down from site. Any delay after 10 days shall be panalised @ Rs. 100.00 per day for a maximum of 10 days).
All as per Serial item No. 75 above but exhaust fan of any sweep of any capacity complete ditto.
All as per Serial item No. 75 above but air circulators/ pedestal fan/ wall mounting fan of any sweep and any capacity complete ditto.
M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed. ( Note: Also refer Note No. (iv) under Serial item No. 75 above)
All as per serial item No. 78 above but exhaust fan of 250 to 300mm sweep complete ditto
All as per serial item No. 78 above but exhaust fan of 350/400mm sweep complete ditto
All as per serial item No. 78 above but aircirculator/ pedestal fan/ wall mounted fan of any sweep complete ditto
Supply only ball bearing suitable for Ceiling fan of any sweep complete all as per the existing specifications and as directed (Make :TATA/ SKF / NBC)
Supply only ball bearing suitable for exhaust fan of any sweep complete all as per the existing specifications and as directed (Make : TATA/SKF / NBC)
Supply only ball bearing suitable for air circulator/ pedestal fan/ wall mounting fan of any sweep complete all as per the existing specifications and as directed (Make : TATA/SKF / NBC)
Supply only brass bush suitable for ceiling fan of any sweep and capapcity complete all as per existing specification and as directed. (Make: FAG/NBC/SKF)
Supply only condenser of 1.5 Mfd suitable for PVC exhaust fan and wall mounted fan of any make and size complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
Supply only condenser of 2.5 Mfd suitable for ceiling fan and wall mounted fan of any make and size complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
Supply only condenser of 3.15 Mfd suitable for Exhuast fan and air circulator fan of any make and size complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
Supply only Fan blades set, powder coated aluminium for ceiling fan of 1200mm sweep of any make/model, Aero dynamically balanced and screwed with suitable size of mild steel screws complete all as per existing specification and as directed.
Supply only Fan blades set, powder coated aluminium for ceiling fan of 1400mm sweep of any make/model, Aero dynamically balanced and screwed with suitable size of mild steel screws complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 18" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 24" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 36" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
S & F in repairs stationary louvers complete with frame suitable for exhaust fan of 380mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed.
S & F in repairs stationary louvers complete with frame suitable for exhaust fan of 400mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed.
M & L for preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The ceiling fan taken down under Serial item No. 75 above shall be painted and measured under this item.)
S & F in repairs plug top, 5 Amps, 3 pin including making connections to existing cables complete all as specified and directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 1.5 sqmm complete all as specified and as directed.
Taking down the existing storage type water heater of any capacity of any type and size by disconnecting electric connection, carring out following necessary repair work, tinkering and welding etc. including de-scaling, brushing and thoroughly cleaning the storage tank/inner water tank, removing of hard water deposits, and connected back and re-fixing in orignal position, grounting, testing and commissioning, complete with entire satisfection of Engr-in-Charge:- (a) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required. (b) Inspect overflaw and vent pipes and remove blockages (if any) (c) Checking and rectify earth continuity of the electrical circuits of the geyser and power points (d) Check, maintain and re-fixing thermostat and re-adjust (e) Visual examination of of fusible plugs for its serviceability (f) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution (g) Checking of indicator lamp for its serviceability (Note: (i) Spare parts/components of geysers shall be measured and paid seperately as "supply only" under respective items here-in-below. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt. (iii) Painting of geyser shall be measured and paid seperately)
Supply only heating element, 1.5KW capapcity, AC 230 volts, pressed/screw/triangular/ceramic type, ISI marked complete all as specified and directed.
Supply only heating element, 2KW capapcity, AC 230 volts, pressed/screw/triangular/ceramic type, ISI marked complete all as specified and directed.
Supply only indicator lamp, retangular/round shape, blue/green/red colour suitable for geyser 50/35/25 ltrs capacity complete all as specified and directed.
Supply only high pressure safety valve/high pressure release valve, dead weight type suitable for geyser of any make and model, ISI marked complete all as directed.
Supply only thermostate switch with thermal setting 40 to 90 degree capacity and relay, 230 Volts, ISI Marked complete all as specified and directed.
Supply only glass wools of approved quality as insulating materials in geyser complete all as directed.
Dismantling and repair to inner shells of geyser of any capacity and of any make by brazing, soldering to leakage portion or patching work as required with using copper plate of 1.5mm thick including shaping to original size including taking down and reassembling the same after repair and including transportation to work shop for repair work and back complete all as directed.
S & F In repairs, outer body complete with top & bottom cover, inspection plate suitable for electric water heater of capacity 25 Litres of any make/model duly powder coated complete all as specified and as directed.
S & F In repairs, base assembly (inner, chromium plated brass, any shape and size with inlet, outlet, thermostate slot, drain plug and clamp or bolts for fixing heating element as per the existing shape suitable for electric water heater of 25 Litres capacity including necessary powder coating complete all as specified and as directed.
S & F in repair chromium plated brass connection tube, 450cm long with two brass union and check nuts for connections to 15mm bore pipe suitable for hot & cold water complete all as specified and directed.
S & F in repairs, 15mm bore, Plug type bib taps, cast iron, screwed for iron pipe and fixed complete all as specified and directed.
S & F in repairs, 15mm bore, angle Stop valve of PTMT, any colour high pressure, screwed for iron pipe and fixed (minimum weight 90 gms) complete all as specified and directed.
Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
S & F in repairs sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp 240V, C-curve, Double pole complete all as specified and as directed.
M & L for taking down/ lowering defective Split AC 1.5/2.0 TR capacity of any make from any height by disconnecting all electric connections, opening & checking in presence of a Board of Officers (to be convened by GE) to ascertain the quantum of defects and Repair Works involves, Repairing/ replacement of unserviceable Parts, cleaning thoroughly condensing Unit to achive proper cooling effect, checking of electronic circuit of machine, changing of wiring with proper size of PVC insulated Copper conductor wires, Brazing the suction/Discharge tubes (as required) and making the entire system fully leakage proof, Re-install the same in Original/ new positition and providing necessary electric connections, testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as "S & F/ M & L" (ii) Replacement of minor spares/ parts such as nuts, bolts & washer, worn out cables as per existing size etc to make the System fully fucntional even if not notified by the BOO shall deemed to be included in the unit quoted rate)
S & F in repair Blower motor with extended shaft and rotary blade complete all as per the existing make and model, single phase, 230/240 Volts, AC to mathc the same Model and capacity of Indoor Unit of Split AC 1.5/2.0 TR capacity with necessaary connections and testing complete all as specified and as directed.
S & F in repair Compressor sealed Unit, Rotary type complete all as per the existing make and model, suitable for Split AC 1.5 TR capacity Outdoor Unit with all accessories including necessary brazing to stop leakage and testing complete all as specified and as directed.
S & F in repair Compressor sealed Unit, Rotary type complete all as per the existing make and model, suitable for Split AC 2.0 TR capacity Outdoor Unit with all accessories including necessary brazing to stop leakage and testing complete all as specified and as directed.
S & F in repair Cooling Coil/ Condenser Unit complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity with necessary connections and testing complete all as specified and as directed.
S & F in repair Fan motor with Blade complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity with necessary connections and testing complete all as specified and as directed.
S & F in repair Indoor Unit complete Set, 230 Volts complete all as per the existing make and model, suitable for Split AC 2.0 TR capacity with necessary connections and testing complete all as specified and as directed.
S & F in repair Remote Auto Sensor Unit & RC, complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity and testing complete all as specified and as directed.
S & F in repair Running capacitor 45/50/60 MFD, 230/240 Volts, 50 Hz complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity with necessary connections and testing complete all as specified and as directed.
S & F in repair Power Circuit (PC Plate) complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity with necessary connections and testing complete all as specified and as directed.
S & F in repair Insulation on and around suction and discharge copper piping with 6.0mm thick flexible Thermo Cool Heat Resistant of best quality (as approved) duly scraped with sticking tape and testing complete all as specified and as directed.
M & L for complete servicing of Indoor and Outdoor unit of Split AC 1.5/2.0 TR capacity of any make and model in situ by cleaning including replacement of air filter in Indoor Unit and testing on completion complete all as specified and as directed. (Note: Replacement of minor spares/ parts required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
Supply and Changing Refrigerant F-22 to all type AC unit/ Refrigerator etc complete all as specified and as directed.
M & L for shifting of Indoor/outdoor unit of Split AC 1.5/2.0 TR capacity to another locations as directed (including taking down and reinstallation) with all accessories including necessary welding, brazing to stop leakages , vaccum test pressure, testing, inserting thick flexible thermo cool and servicing of indoor and outdoor unit and testing complete all as specified and as directed. (Note: Charging of gas shall be measured and paid seperately)
M & L for Opening of defective Refrigerator of any capacity/ Make/ Model/ Type, removal of blockage by flushing out, Brazing (as required) and making the system fully leakage proof, replacing unserviceable compressor and other parts and re-assembling after necessary repair work and testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as "S & F/ M & L" (ii) Replacement of minor spares/ parts as required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
S & F in repair Bimetal Switch complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
S & F in repair Compressor Sealed Unit complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
S & F in repair Cooling Coil complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
S & F in repair Fan Motor with Blade for Evaporator Unit complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
S & F in repair Overload protection Relay complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
S & F in repair Thermostat Switch complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
M & L for complete servicing of Refrigerator of any capacity/ Make/ Model/ Type in situ by cleaning condenser unit, cooling coil and internal parts and testing complete all as specified and as directed. (Note: Replacement of minor spares/ parts required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
M & L for Opening of defective Water Cooler of any capacity/ Make/ Model/ Type, removal of blockage by flushing out, Brazing (as required) and making the system fully leakage proof, cleaning thoroughly Cooling coil to achive proper cooling effect, replacing unserviceable compressor and other parts and re-assembling after necessary repair work and testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as "S & F/ M & L" (ii) Replacement of minor spares/ parts as required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
S & F in repair Blower motor with blade, single phase, 1325 RPM, 230/240 Volts, 50 Hz complete all as per the existing make and model, suitable for Water cooler of any capacity and providng necessary connections and testing complete all as specified and as directed.
S & F in repair Compressor Sealed Unit complete all as per the existing make and model, suitable for Water Cooler of 40/80 Litre capacity and providing necessary connctions and testing complete all as specified and as directed.
S & F in repair Compressor Sealed Unit complete all as per the existing make and model, suitable for Water Cooler of 60/120 Litre capacity and providing necessary connctions and testing complete all as specified and as directed.
S & F in repair Overload Protector to compressor sealed unit complete all as per the existing make and model, suitable for Water Cooler of any capacity and providing necessary connctions and testing complete all as specified and as directed.
S & F in repair 15mm bore, Push cock, brass, chromium plated having inner and outer threaded and fixed to water cooler complete all as specified and as directed.
S & F in repair PVC float valve suitable to fit with water cooler of any capacity complete all as specified and as directed.
S & F in repair Running Capacitor of 10 mfd, 400/440 Voplt AC complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
S & F in repair Thermostat Switch complete all as per the existing make and model, suitable for Water Cooler of any capacity complete all as specified and as directed.
M & L for complete servicing of Water Cooler of any capacity/ Make/ Model/ Type in situ by cleaning condenser unit, Fan motor & Blade, Base Plate including repairs to storage tank and testing complete all as specified and as directed. (Note: Replacement of minor spares/ parts required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
S & F in repair 15mm bore, Plug type bib cock, cast iron, screwed and fixed to water cooler complete all as specified and as directed.
M & L for Opening of defective Deep Freezer 200/ to 400 Litre capacity of any Make/ Model/ Type, removal of blockage by flushing out, Brazing (as required) suction and discharge pipe for making the system fully leakage proof, cleaning thoroughly Cooling coil to achive proper cooling effect, checking of electronic circuit machine, replacement of wiring with proper size of PVC insulated copper conductor wires replacing unserviceable compressor and other parts and re-assembling after necessary repair work and testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as "S & F/ M & L" (ii) Replacement of minor spares/ parts as required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
S & F in repair Compressor Sealed Unit complete all as per the existing make and model, suitable for Deep Freezer 310/320 Litre capacity and providing necessary connctions and testing complete all as specified and as directed.
S & F in repair Fan motor with blade, single phase, 1325 RPM, 230/240 Volts, 50 Hz complete all as per the existing make and model, suitable for Deep Freezer of 200 to 400 Litre capacity and providng necessary connections and testing complete all as specified and as directed.
S & F in repair Relay complete all as per the existing make and model, suitable for Deep Freezer of 200 to 400 Litre capacity and providng necessary connections and testing complete all as specified and as directed.
S & F in repair Thermostat Switch complete all as per the existing make and model, suitable for Deep Freezer of 200 to 400 Litre capacity and providng necessary connections and testing complete all as specified and as directed.
M & L for complete servicing of Deep Freezer, 200 to 400 Litre capacity of any Make/ Model/ Type in situ by cleaning condenser unit, Fan motor & Blade, Base Plate etc and testing complete all as specified and as directed. (Note: Replacement of minor spares/ parts required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
M & L for dismantling of Voltage stabilizer 2.0/3.0 KVA capacity, single phase, 240 Volts AC, repairing as required, replacement of burnt transformer, copper wounded, electronic circuit, relays, indicator light, voltmeter, display, switch and socket etc to make the stabilizer fully functional and re-assmebling and re-instal the same and testing on completion complete all as specified and as directed. (Note: (i) Cost of all materials and labour element required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
M & L for dismantling of Voltage stabilizer 4/5 KVA capacity, single phase, 240 Volts AC, repairing as required, replacement of burnt transformer, copper wounded, electronic circuit, relays, indicator light, voltmeter, display, switch and socket etc to make the stabilizer fully functional and re-assmebling and re-instal the same and testing on completion complete all as specified and as directed. (Note: (i) Cost of all materials and labour element required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
M/S MANASEE
M/S CHAKRA GOHAIN
M/S R D CONSTRUCTION
M/S Abhi Traders
FREEZCON
M/S RK Trading
M/S SINGH TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .