Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹39.3 L+₹1.2 L (3.23%)Rejected-Finance WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹39.3 L+₹1.2 L (3.23%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹39.7 L+₹1.7 L (4.36%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹41.0 L+₹3.0 L (7.85%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Nov 2022, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
MISC REPAIR/ MAINTENANCE OF CEILING TILING PLASTERING AT JCOs MESS MAIN OFFICE BOUNDARY WALL BLDG NO P-186 187 188 AND P-9 BLDG WORKS AND REPLACEMENT OF OLD WIRING INCL FIXTURE/ FITTING AT RRRC UNDER GE (CENTRAL) DELHI CANTT-10
2022_MES_557920_1
GE/C-62/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
23 Dec 2022
15 Oct 2022
12 Nov 2022
15 Oct 2022
10 Nov 2022
29 Oct 2022
15 Oct 2022 - 29 Oct 2022
Amount
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc complete all as specified and directed by Engr-in-Charge.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
All as per srl item No 2 here-in-before but except bricks.
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc up to 10m height incl remove all debris in 2 KM form site complete all as specified and directed.
M &L 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70 Kg per Itr, water ration 17 to 19 % by weight with compressive str as per IS 4031 part 6 applied as per the manufactore instr including necessaery cement screed and prepartion of surface to received ready mix plaster. Complete all as specified and directed by Engineer-in-Charge.
M &L 10mm thick ready mix cement plaster with bulk density 1.4 to 1.70 Kg per Itr, water ration 17 to 19 % by weight with compressive str as per IS 4031 part 6 applied as per the manufactore instr including necessaery cement screed and prepartion of surface to received ready mix plaster. Complete all as specified and directed by Engineer-in-Charge.
M &L 5mm thick ready mix cement plaster with bulk density 1.4 to 1.70 Kg per Itr, water ration 17 to 19 % by weight with compressive str as per IS 4031 part 6 applied as per the manufactore instr including necessaery cement screed and prepartion of surface to received ready mix plaster. Complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specifed as direted by Engr-in-charge.
M&L for preparation of old decorated plastered surfaces of walls, brooming down,washing with water etc and applying two coat of cement based paint complete all as specified and directed.
M&L for preparation of newly plastered of surfaces of wall / Ceiling and applying two coats of weather exterior acrylic emulsion paint by spray gun/ spray machine up to 4 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+3 bldg including scaffolding.
M&L for preparation of newly plastered of internal wall / Ceiling applying two coats of plastic emulsion paint by spray gun/ spray machine up to 4 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+3 bldg including scaffolding.
M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old decoreated external wall / internal wall/Ceiling surface of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying 1 mm thick wall care putty up to 4 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+3 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated internal wall / Ceiling applying two coats of plastic emulsion paint by spray gun/ spray machine up to 4 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+3 bldg including scaffolding.
M&L for preparation of old decoreated/undecoreated external wall two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 4 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+3 bldg including scaffolding.
Dismantling of wall and ceiling/cup board board fibre pulp AC boards etc any thickness including cover fillets removing the wiring and refixing the same including fixture as necessary at site including frame work complete all as specified.
M and L Providing & Fixing False ceiling with semi perforated 12mm thcik micro tegular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and pattern having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 475 (part-4)-1970 and light Code Description unit rate No 429 SUB HEAD :26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizoatal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams oer sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm, vross-T of size 15x32nn of lenght 1200mm amd secondry itermediate cross-T of size 15x32 of lenght 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) ie. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000mm to be fixed on perimeter wall/partition with the help of plastic rawl pluhs at 450mm center to center and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-incharge. Make: Diamond or equivalent as approved by GE.
Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed by Engr-in-Charge.
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed by Engr-in-Charge.
S&F for fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame and fixing with ancher bolts all as specified and as directed.
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames complete all as specified & directed by Engr-in-Charge.
S&F MS butt hinges medium weight 100 mm size fixed with MS screws.
S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws.
S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws.
S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S&F in replacement stainless steel plate rack of size 90x80x25 cm depth size made out of 0.80mm thick sheet complerte all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel sink with drainage board made out of 0.80mm thick sheet for kitchen with plug, washers, waste pipe, waste cuppling incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complerte all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections of bore of tubing 15mm all as specified and directed.
Taking up or down steel tubing and connections of bore of tubing 20mm all as specified and directed.
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed by Engineer-in-Charge.
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed by Engineer-in-Charge.
Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for conceled water tubing etc cutting exceeding 10cm girth but not exc. 20 cm all as directed.
Supply and fix in repair vitreous china wash hand basin (with stands) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size and waste pipe & waste cupling complete all as specified.
Supply and fixin repairs vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘standard Grade P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe ) complete all as specified and directed by Engr-in-Charge.
S&F in repair vitreous china wash down water closet pan (padestal pattern) white incl 'P' or 'S' 100 mm trap and making good the disturbed surface to match with the existing complete all as specified and all as directed.
Supply only plastic water closet seat cover white closed pattern with flat bottom end cover and mild steel chromium plated hanging device Make-Cera/Hindustan complete all as specified.
Supply and fix in repair PVC low level white flushing cistern valveless syphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified.
S & F in repairs 15 mm dia 600mm long PVC connections with brass check nut complete Make Polytuff/symet or equivalent complete all as specified.
S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railing complerte all as specified and directed by Engineer-in-Charge.
S&F in repairs Health faucet, CP brass with 1.50m long flexible pipe complerte all as specified and directed by Engineer-in-Charge.
S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified.
S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F for 15 mm bore gate valve,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S&F for 20 mm bore gate valve,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S & F in repair concealed brass chromium plated stop valve fancy type suitable for 15mm bore of pipe with long shank and cup complete all as specified.
Demolition of stone slab and tiles of any description or thickness in floor apron etc incl remove all tiles and other debris in 2 KM form site complete all as specified and directed.
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed by Engineer-in-Charge.
S&F Non - skid Ceramic colour tiles 600 x600 x 7 to 8 mm thick in floors etc incl 15mm thick screed bed in CM 1:6 in set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
S&F Non - skid Ceramic colour tiles 600 x150 x 7 to 8 mm thick in vertical surfaces etc and 10mm thick screed bed 1:4 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick backing coat in cement mortar (1:6) complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed.
Demolition of concrete and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M & L for 75 mm thick cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection laid in alternate bays and filling the joints with bitumastic filling complete all as specified.
M & L for 40 mm thick cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor & surfaces finished even and smooth using extra cement, complete all as specified.
M&L Providing cement concrete in coping type B-1 ,1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified.
Demolition of reinforced cement concrete in any position all as specified and as directed by Engineer -in-Charge.
M & L for form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
Material and labour for rotational moulded polyethylene water storage tanks white colour 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description complete all as specified.
S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed.
S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed.
Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortor of any diameter incl bends.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete all as specified and directed.
S&F for PVC (SWR) bends & tee any radius, 110 mm bore complete all as specified and directed.
S&F for PVC (SWR) bends & tee any radius, 75 mm bore complete all as specified and directed.
S&F in replacement for 75 mm bore cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S& in replacement F for 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F TMT steel bars of 10 mm dia and over,cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
S & F in repairs for PVC waste coupling 32mm dia PTMT(half or full threaded) suitable for WHB/Sink (min wt 450 gms), completed all as specified & directed
S F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
Taking down carefully copper/aluminium point wiring from wooden battan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely excluding (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc. complete all as specified and directed.
Taking down old MCCB,TPN DBs , SPN DBs,SP MCB & Main Switch/enclosure box of any make and type from the site and making good surface complete all as specified and directed.
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified and directed.
M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :
One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely)
One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
All as per Item No 81 above but Same board.
One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 2.5 Sqmm stranded conductor as earth wire connected to dolly complete (socket and switches to be measured and paid separately) complete all as specified.
M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in and including PVC conduit ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
S&F in replacement switch Piano flush type 5 Amp SP one way all as specified and directed by Engr in Charge.
S&F in replacement switch piano flush type 15 Amp SP one way all as specified and directed by Engr in Charge.
S&F in replacement socket outlet 5 pin 5 Amp flush type all as specified and directed by Engr in Charge.
S&F in replacement socket outlet 2 in 1,3 pin 5/15 Amps all as specified and directed by Engr in Charge.
S&F in replacement ceiling rose 3 phase PVC polycorbonate,isolated body.
Supply and fix S&F in replacement LED batten luminaire surface mounted T-8, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix S&F in replacement LED batten luminaire surface mounted 2 feet system wattage of 12 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥80 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix S&F in replacement 10/12 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and Fix S&F in replacement 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
M&L for breaking old existing wall and making a provn for fixing of 300 mm sweep exhaust fan/250 mm fresh air fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. complete as specified and directed.
M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed.
M&L distribution board SPN 8 way with 100 Amp rated bus bar double door.
STRATO 2x2 Ultra Slim recess mounted EdgeLit LED module with high brightness LED package and unique pattern acrylic de-glaring diffuser sheet for glare free uniform light distrubution suitable for armstrong/grid ceiling.pannel light
M&L Decorative wall mounting Decorative wall light fixture made up of Polycarbonate,suitable for 14W retrofit LED BULB (B-22 base).
Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit consiled and conduit accessories on surface of walls complete all as specified and directed. Note: Three run of 4sqmm cable & one run of PVC conduit shall be measured as one length.
M&L MCB SPN 32 Amp "B " curve .
Supply and fix in repair MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
S&F MCB SP 6-32 Amps 240 volts curve 'B' series 10 KA 50 HZ complete all as specified and directed.
Schedule of Credit
M/S MSD & Associate
imran construction company
ANSH VANSH CONSTRUCTION COMPANY
M/s SAAR ENGINEERS
LAMBA ENTERPRISES
POONAM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .