GE AF THANE
The Garrison Engineer (AF) Thane,Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR/ MAINTENANCE OF WATER SUPPLY DISTRIBUTION PIPE LINES AND JOINTS CONTROL VALVES AT KALINA, LOS, DSC MESS, SNCOS AND OLD AIRPORT AREA,SION,COTTON GREEN AND PAVANIKA UNDER AFS MUMBAI UNDER GE AF THANE
2021_MES_455608_2
8118/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
THANE
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AF THANE
₹50,000
Yes
21 Feb 2022
8 Oct 2021
29 Nov 2021
8 Oct 2021
27 Nov 2021
16 Nov 2021
8 Oct 2021 - 16 Nov 2021
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying pipe line and getting out, in hard/dense Soil ,complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying pipe line and getting out, in soft/loose Soil, complete all as specified and directed by Engineer-in-charge.
Returning, filling including spreading leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed by Engineer-in-charge.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Disconnecting ,dismantling and taking down of unserviceable rusted water tubing CI of size 150 mm from existing place in trenches/wall/floors/ceilings complete all as specified and directed by Engineer-in-Charge:
All as per item No 5 here-in-before but for GI pipe of size100/ 80 mm dia,complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 here-in-before but for GI pipe of size 50 mm dia, complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 here-in-before but for GI pipe of size 40 mm dia, complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 here-in-before but GI of size 25 mm dia, complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 here-in-before but GI of size 20 mm dia, complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 here-in-before but GI of size 15 mm dia ,complete all as specified and directed by Engineer-in-Charge.
Supplying, Laying, connecting and testing of GI pipe 100 mm bore dia , medium grade including necessary fittings in trenches, complete all as specified and directed by Engineer-in-charge.
All as per item No 12 here-in-before but of size 80 mm bore dia,complete all as specified and directed by Engineer-in-charge.
All as per item No 12 here-in-before but of size 50 mm bore dia, complete all as specified and directed by Engineer-in-charge.
All as per item No 12 here-in-before but of size 40 mm bore dia, complete all as specified and directed by Engineer-in-charge.
All as per item No 12 here-in-before but of size 25 mm bore dia, complete all as specified and directed by Engineer-in-charge.
All as per item No 12 here-in-before but of size 20 mm bore dia, complete all as specified and directed by Engineer-in-charge.
All as per item No 12 here-in-before but of size 15 mm bore dia,complete all as specified and directed by Engineer-in-charge.
Supplying ,Laying, connecting and testing GI Pipe of 100 mm bore dia, medium grade including necessary fittings to walls and ceiling or laid in floor including all fixing accessories ,complete all as specified and directed by Engineer-in-Charge
All as per item No 19 here-in-before but of size 80 mm bore dia,complete all as specified and directed by Engineer-in-charge.
All as per item No 19 here-in-before but of size 50 mm bore dia,complete all as specified and directed by Engineer-in-charge.
All as per item No 19 here-in-before but of size 40 mm bore dia, complete all as specified and directed by Engineer-in-charge.
All as per item No 19 here-in-before but of size 25 mm bore dia,complete all as specified and directed by Engineer-in-charge.
All as per item No 19 here-in-before but of size 20 mm bore complete all as specified and directed by Engineer-in-charge.
All as per item No 19 here-in-before but of size 15 mm bore dia,complete all as specified and directed by Engineer-in-charge.
Supply, laying, and fixing of Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" of size 150mm with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed by Engineer-in-charge.
Dismantling and taking out unserviceable Sluice Valve of size 80 mm bore from line , complete all as directed by Engineer-in-charge.
Dismantling and taking out unserviceable Sluice Valve of size 100 mm bore from line, complete all as directed by Engineer-in-charge.
Supply and fix ,in repairs ,Sluice Valve Class PN 1.6 ,80 mm dia with iron wheel head, gaskets nuts, bolts,washers etc, complete all as directed by Engineer-in-Charge.
Supply and fix, in repairs, Sluice Valve Class PN 1.6 , 100 mm dia with iron wheel head, gaskets nuts, bolts,washers etc, complete all as directed by Engineer-in-Charge.
Dismantling and taking out unserviceable gun metal gate valve of size 50 mm to 40 mm bore from existing line ,complete all as specified and as directed by Engr - in- charge.
Dismantling and taking out unserviceable gun metal gate valve/stop valve of size 25 mm to 20 mm ,complete all as specified and as directed.
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 50 mm dia, complete all as specified and as directed by Engineer - in-Charge:
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 40 mm dia, complete all as specified and as directed by Engineer - in-Charge:
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 25 mm dia ,complete all as specified and as directed by Engineer - in-Charge:
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 20 mm dia ,complete all as specified and as directed by Engineer - in-Charge:
M&L for Dismantling damage and broken valve chamber of size 1200x1200x900mm including unserviceable rusted MS cover complete without disturbing the existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in CM (1:6) with 10mm thick plaster internally and 15mm thick externally in CM (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 502x50x6mm MS complete with 2 coat of synthatic enameled paint over a coat of red oxied on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes ,complete all as specified and as directed by Engr - in- charge.
All as per item no 36 here-in-before but of size 900 mm X 900 mm X 900 mm internal complete all as specified and directed by Engineer-in-charge.
Material and Labour for PCC (1:2:4) type B-1 for supporting pillar posts for pipes/flooring/pavings / foundation for motor etc ,complete all as specified and directed by Engineer-in-charge.
Material and Labour for brick work with subclass B bricks using old size brick, in cement mortar 1 : 4 , straight or curved on plan exc 6m mean radius including taking down unserviceable bricks ,complete all as specified and directed by Engineer-in-charge.
Material and Labour for cutting bituminous surfaces road to a depth of n exc 60cm and not exceeding 60cm in width for taking out or laying of GI tubing and refilling the same with necessary making good/level to the existing surface ,complete all as specified and as directed by Engineer-in-charge.
Demolition and dismantling of Cement concret of any description and in any position including removing the materials to a distance not exceeding 100 m,complete all as specified and as directed by Engineer-in-charge.
M&L for fabrication and errection of base frame / Iron Ladder/Duct covers of UG Tank / OH Tank for centrufugal pumpset fabricated out of structural steel sections such as joint, hannel, angle, or tee sections including grouting nuts bolts, washers , checknuts etc and painting the frame with two coats of rust proof paint over a coat of zinc primer including dismantling and taking down rusted steel items from existing places ,complete all as specified and as directed by Engineer-in-charge.
M&L for Cleaning of RCC UG sumps of the following capacities by involving of the followings 08(Eight) stage of cleaning process ,complete all as specified and as directed by Engineer-in-charge. (i) De-watering by high pressure submersible pump (ii) Removal of sludge from sump (iii) Cleaning of walls, floors, ceiling etc complete (iv) Removing dirt and sludge by vacuum pump (v) Anti- Bacterial Tratment of inside of tank which effective against all pathogens all complete. (vi) Applying one coat of white wash internal surfaces. (vii) Replacenylon net for vent pipes & man hole cover (viii) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note :- The tendere shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :- (i) The contractor shall be provide dewatering pump of suitable capacity. The rate is inclusive of rent/hiring charge complete. (ii) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed all as per direction of Engineer-in-charge. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 1000/- per day.
For 20000 Gallon capacity
For 10000 Gallon capacity
For 7500 Gallon capacity
For 7000 Gallon capacity
For 2000 Gallon capacity
M& L for Cleaning of RCC Over Head Tanks of 15000/20000 Gallon capacities by involving of the followings 07(SEVEN) stage of cleaning process complete all as specified and directed (i) De-watering by all complete (ii) Removal of sludge from RCC Over Head Tanks (iii) Cleaning of walls, floors, ceiling etc all complete (iv) Removing dirt and sludge by vacuum pump (v) Applying one coat of white wash internaL surfaces. (vi) Replace nylon net for vent pipes & man hole cover (vii) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note:- The tendere shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :- (i) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (ii) Material removed from the tank shall be disposed off at out side. (iii) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 1000/- per day. (iv) All safety with Gadgets like Safety Belts, Special Safety Ladder, Helmets, Heavy Duty Gum Boots, Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system.
M& L for Disconnecting, dismantling and taking out after disconnecting of incoming and outgoing water & electric connections & transportation to work shop of 3 HP to 5 HP pumping set for repairs/ rewinding.Dismantling the pumpset complete, separating the parts such as rotor, impellar,bearing, shaft seal, shaft cleaning of all dismantled parts, dismantling the motor and cutting & removing burnt winding from slot cleaning the slots , packing the slots with insulated packing material, rewinding with super enameled copper winding wire of same guage varnishing the stator & drying in oven reassembling the pumpset complete with and including new packing material, gland packing , stud, new set of bearings, terminal plate, transporting back to plant room, refixing on foundation connecting up and testing ,complete all as specified and as directed by Engineer-in-charge.
All as per item No 46 herein but for motor of capacity 7.5 HP ,complete all as specified and as directed by Engineer-in-charge.
All as per item No 46 herein but for motor of capacity 10 HP ,complete all as specified and as directed by Engineer-in-charge.
All as per item No 46 herein but for motor of capacity 20 HP,complete all as specified and as directed by Engineer-in-charge.
S&F, in repair, fully automatic DOL starter suitable for 3 to 5 HP Pumping set 415 volts 3 phase as existing in panel board ,complete all as specified and as directed by Engineer-in-charge..Make “Siemens / L&T / Bhartiya Cutler Hammer ”
S&F, in repair, fully automatic DOL starter suitable for 7.5 HP Pumping set 415 volts 3 phase as existing in panel board ,complete all as specified and as directed by Engineer-in-charge .Make “Siemens / L&T / Bhartiya Cutler Hammer ”
S&F, in repair, fully automatic Star-Delta starter suitable for 10 HP Pumping set 415 volts 3 phase as existing in panel board,complete all as specified and directed .Make “Siemens / L&T / Bhartiya Cutler Hammer ”
S&F, in repair, fully automatic Star-Delta starter suitable for 20 HP Pumping set 415 volts 3 phase as existing in panel board including taking down existing starter ,complete all as specified and as directed by Engineer-in-charge. .Make “Siemens / L&T / Bhartiya Cutler Hammer ”
S&F, in repair, Contactor ML-3, 3 Pole with DC Coil suitable for 3 to 5 HP 415 volts 3 phase motor ,complete all as specified and as directed by Engineer-in-charge.
S&F, in repair, Contactor ML-3, 3 Pole with DC Coil suitable for 7.5 HP 415 volts 3 phase motor ,complete all as specified and as directed by Engineer-in-charge.
S&F, in repair, Contactor ML-2 ,3 Pole with DC Coil suitable for 10 HP 415 volts 3 phase motor,complete all as specified and as directed by Engineer-in-charge.
S&F, in repair,Contactor ML-3 Pole with DC Coil for 20 HP motor ,complete all as specified and as directed by Engineer-in-charge.
S&F, in repair, Single Phase Preventer for motor protection Circuit Breaker up to 20 HP Motor ,complete all as specified and as directed by Engineer-in-charge.
S&F, in repair, Single Phase Preventer for motor protection Circuit Breaker up to 15 HP Motor ,complete all as specified and as directed by Engineer-in-charge.
S&F, in repair, Single Phase Preventer for motor protection Circuit Breaker up to 7.5 HP Motor,complete all as specified and as directed by Engineer-in-charge.
S&F, in repair, Single Phase Preventer for motor protection Circuit Breaker up to 10 HP Motor ,complete all as specified and as directed by Engineer-in-charge.
Supply and Fix foot valve of Brass of Size 80 MM Dia ,complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of Ductile Iron pipe bends (any type, radius and angle) tapers any type (Straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch "Y" junction, double branch, cross (socket and spigot type) for dia of pipe 200 mm bore ,complete all as specified and as directed by Engineer-in-charge.
M&L for Disconnecting, dismantling and taking out after disconnecting of incoming and outgoing water & electric connections & transportation to work shop of 3 HP to 5 HP pumping set for repairs/ rewinding.Dismantling the pumpset complete, separating the parts such as rotor, impellar,bearing, shaft seal, shaft cleaning of all dismantled parts, dismantling the motor and cutting & removing burnt winding from slot cleaning the slots , packing the slots with insulated packing material, rewinding with super enameled copper winding wire of same guage varnishing the stator & drying in oven reassembling the pumpset complete with and including new packing material, gland packing , stud, new set of bearings, terminal plate, transporting back to plant room, refixing on foundation connecting up and testing ,complete all as specified and as directed by Engineer-in-charge.
All as per item No 64 here in before but for motor of capacity above 5 HP upto 7.5 HP ,complete all as specified and as directed by Engineer-in-charge.
All as per item No 64 here in before but for motor of capacity 10 HP to 20 HP ,complete all as specified and as directed by Engineer-in-charge.
M/S KHUSHI ENTERPRISES
NANGIA AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .