Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC FARIDABAD | FARIDABAD | HARYANA | 121001 | ₹5.3 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹5.4 Cr+₹5.8 L (1.09%)Rejected-Finance PLOT NO 160 2 KH NO 443 NASIR PUR VILLAGE SOUTH WEST DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | ₹5.4 Cr+₹5.8 L (1.09%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹5.6 Cr+₹26.9 L (5.05%)Rejected-Finance | ₹5.6 Cr+₹26.9 L (5.05%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹5.7 Cr+₹37.0 L (6.96%)Rejected-Finance | ₹5.7 Cr+₹37.0 L (6.96%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹5.8 Cr+₹49.9 L (9.39%)Rejected-Finance 123 B CENTRAL AVENUE SAINIK FARMS SOUTH DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | ₹5.8 Cr+₹49.9 L (9.39%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹6.3 Cr
EMD Value
₹6.4 L
Closing Date
26 Mar 2025, 6:00 pmClosed
HQ Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
ADDN ALTN AND SPL REPAIR OF JCO OR MD ACCN AT KARAN VIHAR UNDER GE CENTRAL DELHI CANTT 10
2025_MES_698885_1
CEDZ/TOKEN-06 OF 2025
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt-10
As per NIT
10 documents required · 10 mandatory
₹3,000
GE Central
₹6.4 L
Yes
19 Jul 2025
21 Feb 2025
28 Mar 2025
21 Feb 2025
26 Mar 2025
19 Mar 2025
21 Feb 2025 - 28 Feb 2025
Amount
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified & directed.
Demolition of reinforced cement concrete such as chajja,manhole cover water tank parapet wall ,lintel up to 4.5 m span including hieght upto eight storey building , in any position all as specified and as directed by Engineer -in-Charge.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
M&L for old size bricks in cement mortar 1:4, brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in complete all as specified and directed
M&L for old size bricks in cement mortar 1:4, brickwork with fly ash bricks, straight or curved on plan to any radius half brick thick walls, built in complete all as specified and directed
M&L for cement concrete 40mm thick type B-1 1:2:4 (20mm graded aggregate) ,even and smooth without using extra cement finishes of paths laid in alternative panel, complete all as specified
S & F in repairs kitchen plate rack with four shelves made out of stainless steel sheet 1mm thick over all size 90x60x25cm complete all as specified. .
Complelte removal of existing old treatment on surface of walls with machenical grinder (machine) as per specification of manufacturer paints/OBDs complete all as specified and directed.
M& L a coat of alkali resistant primer over alread prepred surface of walls complete all as specified and directed.
M& L for applying two coats of oil bound distemper on old wall surface with roller brush complete all as specified and directed.
M&L for Complete removal of existing old treatment on surface of walls with mechanical grinder (machine) as per specification of manufacturer paints and preparing old plastered surfaces of wall and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M&L for prepared surface of old ceiling and apply three coat of white wash on ceiling, complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces of walls finished even and smooth without using extra cement in multistorey building etc, complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls finished fair and even without using extra cemet in multistorey building, complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar 1:3 finished fair and even surface without using extra cement on ceiling, chajja in multy storey building etc complete all as specified
M&L for preparation of newly plastered surfaces of wall and apply two coat oil bond distemper over one coat of primer from the same manufacture complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete.
M&L for preparation of newly plastered surfaces of wall and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed. Note : MTC and Screw Out Test will be provided by Contractor.
S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2 and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free. Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws to include edges liping. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen and Cabinets. Note : MTC and Screw Out Test will be provided by Contractor.
S&F continous (piano hinges, mild steel bright finish or electro galvanized width of flap 30mm when open complete all as specified.
S&F 40mm dia cup board knob fixed with nut screw and washer of mild steel bright finish complete all as specified.
S&F 100mm size hasp and stable safety type aluminium anodised with mild steel hinge pin including bolt to hinge palte and fixed screws complete all as specified.
M and L Providing & Fixing False ceiling with semi perforated 12mm thcik micro tegular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture,design and pattern having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 475 (part-4)-1970 and light Code Description unit rate No 429 SUB HEAD :26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizoatal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams oer sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm, vross-T of size 15x32nn of lenght 1200mm amd secondry itermediate cross-T of size 15x32 of lenght 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) ie. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall/partition with the help of plastic rawl pluhs at 450mm center to center and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-incharge.
Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of density 650 kg/cbm manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strength and safety purpose (confirming as per IS 4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws, etc. complete all as specified& directed.” Note: MTC and Screw Out Test will be provided by Contractor
S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65 x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (max toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge. Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made.
S&F stainless steel AISI 304 grade floor door stopper with hard drawn steel spring 140mm long complete all as specified and directed.
Supply and fix stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized iron staples including wooden beadings, complete all as specified and directed.
S&F SS barrel tower bolt extruded section 200mm long and fixed with SS Screws (ISI Marked)
S&F SS barrel tower bolt extruded section 150mm long and fixed with SS Screws (ISI Marked)
S&F 300mm extruded section SS sliding door bolt with hasp and staple and fixing bolt and nut (ISI Marked)
S&F 100mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked)
S&F 150mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked)
S&F SS butt hinges medium weight 100mm size fixed with SS screws (ISI Marked)
S&F SS butt hinges medium weight 75mm size fixed with SS screws (ISI Marked)
Supply and fix 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate including welding where ever necessary complete all as specified and directed Make:Ritz or equivelent
S&F brass chromium plated magic eye complete all as specified
Material and labour for preparing old previously untreated wood surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified
Supply and fix in repairs sink with drainage board made of stainless steel 1 mm thick for kitchen with plugs, washers and waste including bedding in cement mortar to dwarf wall or including fixing cantilever, brackets and connecting union to pipe over all size 915 mm X 460 mm, bowl size 410 mm X 330 mm X 160 mm. .
Material and labour for welding in repairs not exc 2.5 cm in length complete all as directed
Supplying and laying of CPVC pipes of outer dia 20mm thick SDR 11 & Plain CPVC SDR 11 fittings in trenches or fixed with clamps including all necessay fittings complete all as directed. Note: supporting platform of pipeline on the roof surface will be made and rates inclusive in this item
All as per item No. 53 above but 50mm dia.
All as per item No. 53 above but 40mm dia.
All as per item No. 53 above but 32mm dia.
All as per item No. 53 above but 25mm dia.
S&F 20mm outer diameter CPVC Female brass threaded adaptor complete all as specified and directed.
S&F 20mm outer dia CPVC ball valve/gate valve complete all as specified and directed
S&F 50mm outer dia CPVC ball valve/gate valve complete all as specified and directed
S&F in repairs Health faucet, CP brass with 1.50m long flexible pipe complete all as specified and directed by Engineer-in-Charge.
Cuttting chases for concealed water tubing or concealed conduct wiring etc and making good cutting exc 10 cm grith in brick wall.
Supply and fix in repairs vitreous china wash hand basin (flat back) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size complete all as specified.
Supply only PVC low level white flushing cistern valveless syphonic action type 10 lts capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, complete all as specified.
Supply and fix in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified.
S&F in repairs 15mm dia Brass chromium plated mode 2 in 1 WHB mixture model Quarter half turn (SOLO) of as complete all as specified & directed.
S&F in repairs 15mm dia brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO) as all specified and as directed.
S&F in repairs 15mm dia Brass chromium plated mode 2 in 1 sink mixture model Quarter half turn (SOLO) of as complete all as specified & directed.
Supply and fix in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed. (Make: Zim/ Parko).
S&F in repair PVC connection 15mm dia and 60 cms long with two nos of brass nuts and washers complete .
Supply and fix in repairs shower rose, chromium plated brass, fancy type, 125 mm and dia 15mm, with or without swivel , any size, including fixing to steel pipe or union, complete all as directed.
S & F in repairs towel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embeded in cement mortar 1:3 with MS screws etc complete all as specified and directed.
S&F in repair Soap dish, vitreous China white, approximate size 160x 160x90mm , complete all as specified.
M&L for glazed ceramic coloured tiles 600x300mm of 7 to 8 mm thick in dado, set and jointed in neat cement slurry and pointed in colour cement to match including rendering 10mm thick in cement mortar 1:3, complete all as specified and as directed.
M&L for non skid ceramic coloured tiles of 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white/coloured cement to match with the shade of tiles and including cement screeding 15mm thick in cement mortar 1:4, complete all as specified and as directed
Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dusts etcand applying neat cement slurry over rough concrete surface with 3.00 kg of cement/sqm.
M&L for Ceramic tiles of light shade 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including provn of 15mm thick screed bed or bedding layer in CM 1:4 etc complete all as specified .
M&L for Ceramic tiles of light shade 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including provn of 10mm thick rendering of backing coat in CM 1:4 etc complete all as specified .
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and chamfered edges complete and including provn of 20mm thick screed bed or bedding layer in CM 1:4 etc complete all as specified .
All as per above but in riser skirting/dado and pillar over and including 10 mm thick rendering in CM 1:3 complete all as slpecified and directed.
M&l for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situationscomplete all as specified and directed.
M&L for 16-18mm thick granite ‘Jade black’ table rubbed and polished in Step, Jambs, Pillar, Window Cill, Cooking Platform (In single piece) with additional 75mm width of same granite patti stick with araldite or equivalent adhesive full moulding of edges to match the colour of granite, including 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed Note:- (a) Additional 75mm width patti shall be measured separately. (b) Minimum market rate of granite should not be less than Rs.1500/- Sqm including GST.
M&L Providing 75mm thick cement concrete type C-2, 1:3:6 ( using 40mm graded stone aggregate), as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement complete all as specified and directed.
S&F Stainless steel drapery curtain rods confirming to ASTM Schedule 5S gold or antique silver 25 mm nominal dia of SS-304 grade of approved quality with two number decorative brackets design as approved fixed in brick/concrete wall with same finished knobs/latto on each end of curtain rod including taking down old drapery rod, complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for rough finished surfaces of concrete complete all as specified and directed.
S&F TMT steel bars of 10 mm dia and over,cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed by Engineer-in-Charge
S&F TMT steel bars of 6 to 8mm dia and over,cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed by Engineer-in-Charge
Demolition and breaking up of 100mm dia drain pipes (CI,AC etc) set in any cement mortor of any diameter incl bends.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F of 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and trenches complete all as specified and directed.
All as of above item but of 75mm dia complete all as specified and directed.
S & F bends 110mm dia PVC (SWR) bends complete all as specified and directed.
S & F bends 75mm dia PVC (SWR) bends complete all as specified and directed.
S & F 110 mm dia size,PVC (SWR) branch piece,single (single Y) equal or unequal complete all as specified and directed.
S & F 110mm dia PVC (SWR) junction single,(Single T) equal or unequal with oval acces door complete alla as specified and directed.
S & F 75mm dia PVC (SWR) junction single,(Single T) equal or unequal with oval access door complete all as specified and directed.
S & F 75mm dia PVC (SWR) floor trap, plain with 100mm stainless steel grating including jointing with solvent cement complete all as specified and directed.
S&F 100mm dia stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stay including boltstand nuts seuring ends of stays to wall complete all as specified and directed.
M&L for 2nd class hardwood exc 13sqcm & nexc 25 sqcm plain fillets bullnosed, splayed, chamfered or rounded on one edge or face, secured with nails or brads complete all as specified and directed.
S&F framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Fe-410- W(Gde-E-250) quality-B framed work of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, Note :- frame provide over chhajja upto G+8 storey building using scaffolding .
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified Note :- steel sheet , provide over chhajja upto G+8 storey building using scaffolding .
M&L for chipping out spilled and loose concrete cover and derusting steel reinforement of concrete column, beam, slab, chajjas, parapets and the like as directed upto 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforecement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guiniting mix using one part of OPC 53 grade and two part of gaggar sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out upto 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforecement all concrete surfaces shall be throughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
Dismantling of brick tiles or terracing tiles single layers as on roof complete all as directed
Demolition of mud/rubbish in roof any thickness inlcl plastering and leeping and disposal outside MoD land all as specified and directed.
S & F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner.
M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof padding, coping,kerbs & sunken surface finished even and smooth without using extra cement complete all as specified & directed.
M&L for applying APP based polymeric water proofing membrane granular finish minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 160 gms/sqm) over Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces over a coat of bitumen primer conforming to IS -3384 @ 0.40 ltr/sqm over prepared roof surfaces with using butane gas torch ,forcing overlap 100mm at ends and 75 mm at sides and sealing
S & F outer frame 40mmx40mm with 1.3mm thickness, corner 45 degre cut & aluminum welded center mullion size 40mmx65mm also welded , fixed 5mm frosted glass EPDM rubber gasket with provision for fresh air fan, full system powder coating with pure polister coat of any shade install with SS screw rol plug pvc & silicone complete all as specified and directed.
S&F aluminium window as per TD drg No. CEDZ/TD-316 with following specifications :- (i) Outer frame of size 40mmx114mm with 1.3mm thickness, corner 45 degree cut & aluminium welded. (ii) Center mullion of size 40mmx65mm. (iii) Welded shutter (02 Nos) of size 40mmx60mmx1.3mm thickness 45 degree cut mechanically joint with 6mm allen key bolt clamp with 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock, aluminium kobra hinges 2 Nos per shutter. (iv) 12mm SS 202 grade round bar safety grill at 100mm cc distance modified to 150mm cc distance in front of handle, welded at both ends with 6mm SS 202 grade round bar. (v) Welded wiremesh shutter (2 Nos) of size 40mmx18mmx1.3mm thickness 45 degree cut with 0.45mm nominal dia of SS wire mesh, SS 75mm long hinges & PVC magnet. (vi) Entire window shall be powder coated with pure polyster coat of any shade as approved by GE. (vii) Window shall be installed with silicone complete all as specified and directed by Engr-in-charge.
S&F aluminium window as per TD drg No. CEDZ/TD-316 with following specifications :- (i) Outer frame of size 40mmx114mm with 1.3mm thickness, corner 45 degree cut & aluminium welded. (ii) Center mullion of size 40mmx65mm. (iii) Welded shutter (02 Nos) of size 40mmx60mmx1.3mm thickness 45 degree cut mechanically joint with 6mm allen key bolt clamp with 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock, aluminium kobra hinges 2 Nos per shutter. (iv) 12mm SS 202 grade round bar safety grill at 100mm cc distance modified to 150mm cc distance in front of handle, welded at both ends with 6mm SS 202 grade round bar. (v) Welded wiremesh shutter (2 Nos) of size 40mmx18mmx1.3mm thickness 45 degree cut with 0.45mm nominal dia of SS wire mesh, SS 75mm long hinges & PVC magnet. (vi) Entire window shall be powder coated with pure polyster coat of any shade as approved by GE. (vii) Windwo shall have provision for installation of window AC/Desert Cooler and provision of windwo glass shutter, wiremesh, grill and necessary fittings and locking arrangements for subject portion will be modified as per ground requirement during the execution as per directions of Engr-in-charge. (viii) Window shall be installed with silicone, complete all as specified and directed by Engr-in-charge.
S & F Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified and directed.
Supply only integral water proofing compound (ISI marked).
S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as specified and directed.
Supply plastic water closet seat cover white closed pattern with flat bottom end cover and mild steel chromium plated hanging device complete all as specified and directed
M&L 5.5mm thick sheet glass n exc 0.5 sqm each pane ordinary quality and glazing withoil putty or fixed with beads, all as specified and directed.
M&L for Preventive treatment against the danger of carbonation in exposed faces of RCC members :- (i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting where necessary as recommended by Engr-in-charge. (ii) Further, cleaning using biocide(as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. Sand blasting to be done to remove trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufacturer. (vi) Apply a more coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete all as specified and directed. (vii) Sprinkle sand cover over surface to recive new.
M&L for followings :- (i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible from all sides) (iii) Removal of cover concrete with under cutting of up to a depth of 10mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if needed) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re-bars (those towards the concrete substrate) should not be left without coating. NOTE :- Measurement will be taken of surface area of reinforcement bars.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) upto 50 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer. (v) Supply and applying of rust removing chemical to remove rust from existing reinforcement. complete all as specified and directed.
1. Injecting microfine cement in the porous and honey comb concrete with the help of plastic nozzals 12 mm dia with the help of the drill machine 2. Packing the nozals with the help of the cement mortar 3. Marking the area in marker as directed by the Engr-in-charge. 4. Drilling holes of 16mm dia in an orthogonal grid on exposed cone of member @ 150 mm c/c both way, depth of the hole shall be about 60% of the element thickness. Note : pressure shall be in the range of 6 Bar and shall be done in nipples one by one as per order recommended by manufacturer. Mixing of resin and hardenere shall be mixed in small quantities so as it is consumed with in 30 minutes. Before use mixer shall be stirred thorough.
Providing and suppling and injecting microfine cement with the 8000 Blaine in the the area as directed by engr-in-charge.
Supply & fixing 12 mm dia steel sheer connector in grid pattern in between old core and new concrete as wherever directed by Engr-in-charge and as specified by manufacturer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA). ( The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed.
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note : The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item.
M&L for Drilling & chemical anchoring of new rebars/stirrups :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-8 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item)
M&L for Drilling & chemical anchoring of new rebars :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 16 & 20 mm dia bar - drilling length 160 to 180 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item)
M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed.Note : Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of RCC jalli of any size and in any position, complete all as specified and directed.
M&L for M-35 design mix concrete for Beams, cantilevers, lintels, columns pillars,water tanks, slabs, balconies, canopies, deck slabs etc. or in similar articles upto 9th floor level complete all as specified and directed.
Excavation in trenches (soft/loose soil) n exc. 1.5m wide and n exc 1.5 m in depth for foundation etc. and getting out all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material exc. 250m but not exceeding 500m and depositing where directed all as specified.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 all as specified and directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 200mm, complete all as specified & directed.
Supply and laying DWCPE (SN8) 200mm dia pipes and snap fit coupler incl testing and laid properly, jointed laid in trenches to a level on cocrete bed complete all as specified and directed by Engineer-in-charge.
M&l for sand cushioning under floors, laying of interlocking paver block and similar works including watering & consolidation, complete all as specified & directed.
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, manhole and mass concrete complete all as specified and directed.
M&L for medium duty perforated precast machine pressed drain cover slab 80 mm thick of PCC 1:1.5:3 type B-1 and 10mm TMT bars including flat iron 150mmx6mm all around the slab and 40mm dia hole at 100mm C/C , size of slab as required at site and complete all as specified and directed.
M&L for PCC 1:2:4, nominal mix, type B-2, using 40mm graded crushed stone aggregate as in surface channel and drains including necessary form work, complete all as specified & directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc. complete all as specified and directed.
M&L for brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
M&L for preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint of any tint over a coat of cement primer, complete all as specified & directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified & directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size M-40 Grade, 80mm thick confirming to IS-15658-2006 with grey cement and pigments laid, complete all as specified & directed.
M&L for PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
M&L for 100mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
Supply & fixing factory made 100% Solid WPC (Wood Polymer Composite) - Door Frame 75mm x 50 mm (Moulded) Single Rebated, made from Wood Polymer Composite (Single Extruded Process) material comprising of virgin PVC polymer of K Value 57-60 (Suspension Grade), Calcium Carbonate and Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/cum & manufactured by Certified Company, having good screw holding capacity (Screw Withdrawal strength of (Min.990 N), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water/Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners/Hold Fast of required dia and length, all as per specifications drawings as directed by the Engineer-In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing.
Supply and fixing Factory Made 18mm thick 100% Solid WPC (Wood polymer Composite) JALI of required size comprising of virgin PVC resin of K Value 58-60 (Suspension Grade), Calcium Carbonate and natural fibers (Wood Powders/rice husk/ wheat husk) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded (Inner) with having minimum density not less than 650 kg/cum manufactured by Certified Company, having good screw holding capacity (Screw Withdrawal strength of 2000 N (Face) & 1100 N (Edge), Minimum Compressive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free. Water/ Moisture Proof and Fire Retardant. WPC Jali to be fixed with stainless Steel butt hinges (if required) of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company for Interiors / Kitchen shutters / Balcony, Internal Doors and Partitions etc.
Description of Work / Item(s)
Amount
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc, complete all as specified and directed.
Taking down defective switch fuse main board /MCCB Enclosure/ distribution iron clad or sheet metal enclosure/ MCB DBs with MCBs of any capacity and make including wooden board etc complete all as specified and directed.
Taking down old submain wiring of any size and make from the site and making good disturbed surface complete all as specified and directed.
Disconnecting electric connection and taking down of ceiling fan/ Exhaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard, complete all as specified and directed.
M&L point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through (in existing conduit) concealed in wall/fixed to roof, ceiling etc and including provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick GI sheet 120 GSM with earthing terminal steel duly painted concealed in walls, with modular base frame ISI marked top cover with brass/chromium plated screws for housing switches, socket outlets, fan regulators etc, complete all as specified and as directed for the followings:-
One light /Ceiling fan/exhaust fan point controlled by one switch.
One light point controlled by two nos, two way switches
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One bell point controlled by one bell push.
M&L point wiring with PVC insulated unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts single core drawn through (in existing conduit ) concealed in wall and including provision of 2.5 sqmm single core pvc insulated multistranded unsheathed copper conductor cable FRLS as earth continuity condoctor, fabricated sunken terminal box made out of 1.60 mm thick GI sheet 120 GSM with earthing terminal steel duly painted concealed in walls, with modular base frame ISI marked top cover with brass/chromium plated screws for housing switches, socket outlets etc, one run of using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, complete all as specified and as directed.
M&L point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick GI sheet 120 GSM with earthing terminal steel duly painted concealed in walls, with modular base frame ISI marked top cover with brass/chromium plated screws for housing switches, socket outlets, fan regulators etc, complete all as specified and as directed for the followings:-
One light /Ceiling fan/exhaust fan point controlled by one switch.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
M&L point wiring with PVC insulated unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories concealed in wall and including provision of 2.5 sqmm single core pvc insulated multistranded unsheathed copper conductor cable FRLS as earth continuity condoctor, fabricated sunken terminal box made out of 1.60 mm thick GI sheet 120 GSM with earthing terminal steel duly painted concealed in walls, with modular base frame ISI marked top cover with brass/chromium plated screws for housing switches, socket outlets etc and one run of using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified. Notes for Item 5 to 8 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing & caping/ existing conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
S&F Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable, 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls complete all as specified and directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
M&L for Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls complete all as specified and directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
S&F Switch modular type 6 Amp SP one way ISI marked complete all as specified and directed. Make: Legrand Cat Part No. 573400, Schneider Cat No. X1001WH, Anchor Roma Cat Part No.21011
S&F Switch modular type 6 Amp SP two way ISI marked complete all as specified and directed. MAKE: Legrand Cat Part No 573401, Schneider Cat No X1002WH, Anchor Roma Cat Part No 21033
S&F Switch modular type type 16 Amp SP one way, ISI marked, complete all as specified and directed. MAKE: Legrand Cat Part No 573410, Schneider Cat No X11001WH, Anchor Roma Cat Part No 21521
S&F Modular type socket outlet 5 pin 6 Amp flush type, ISI marked complete all as specified and directed. MAKE: Legrand Cat Part No 573424, Schneider Cat No X2005WHNS, Anchor Roma Cat No 21102
S&F Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked, complete all as specified and directed. MAKE: Legrand Cat Part No 573471, Schneider Cat No X2106WH, Anchor Roma Cat No 30828
S&F Ceiling rose 3 terminals PVC polycorbonate, isolated body, complete all as specified and directed.
S&F Modular electronic fan regulator step type, 2 module , 360 degree rotation complete all as specified and directed. MAKE : Legrand Cat Part No 573416, Schneider Cat No X3100WH, Anchor Roma Cat No 22546
S&F Bell push, modular type, 6 amp, 1 module ISI marked, complete all as specified and directed. MAKE: Legrand Cat Part No 573413, Schneider Cat No X1005WH, Anchor Roma Cat No 21044
S&F Bell ding dong AC,230 volts, single pole, complete all as specified and directed.
S&F for angle Lamp holder with metalic ring, pvc/ polycarbonate type back plate, complete all as specified and directed.
S&F LED bulb 09 watt, 900 lumens out put, 6500K suitable for B-22 base, complete all as specified and directed.
M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 25 x 4 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised strip and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.
S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link, complete all as specified and directed.
S&F MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed.
S&F MCB SP 6 - 32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed.
S&F LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminarie level ≥120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engr-in-charge. Note : All the above mentioned specifications will be verified through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
S&F LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. Note : All the above mentioned specifications will be verified through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
S&F in replacement of decorative type wall mounted luminaire with unbreakable poly carbonate materials (comet type) with 1x14 watt LED bulb B22 Base, complete all as specified and directed.
S&F in replacement of LED 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25000 burning hours at L70 criteria, Power Factor >0.90, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed, complete all as specified and directed. Note :- All the above mentioned specifications will be verified through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures
S&F in replacement of surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed, complete all as specified and directed.
S&F Surface exhaust fans metal body AC single phase 230/240 V of size 300 mm sweep, Air flow rate > 900cum/min, Bird screen for protection against birds, double ball bearing, metal body with louvre with louvre for fixing of exhaust fan, complete all as specified and directed.
S&F Ceiling fans complete three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery >220cum/min, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible copper cable pvc insulated of suitable length, down rods, electronic regulator and accessories complete. Against BLDC conversion, complete all as specified and directed. Note : Fan regulator shall be deemed included in quoted rate.
S&F AC/ Geyser Modular type Box single pole and neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with suitable sand and cement, complete all as specified and directed.
S&F Surface water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braidedpipe with adopter for inlet and outlet water connection having adjustable knob for temperature control and inner tank should be glass line coated, capacity 25 Ltrs, having heating element 2 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed .
S&F Fresh air fan PVC body air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required, complete all as specified and directed.
S&F Pressure die cast aluminium housing LED street light luminaires with IP66 deg. of protection suitable for 35 watt LED fitting duly fixed on 40 mm dia GI mast including 40X 5 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting, complete all as specified and directed. Note : The quoted rates shall be deemed included all accessories like suitable GI pipe mast, 50x6 mm thick MS flat, fashner, nut & bolts, suitable length of flexiable wire.
M&L for providing protection pipe PVC or flexible pipe as reqd at site to out going cables, cleaning of LT panel boards with air blower cleaning inside, dressing in proper alignment complete, replacement of rusted iron parts with new one with suitable size of angles/strips, painting of new parts with matching clolour as per existing, tightening of fixing bolts and nuts, providing thimbles to whole bunch of wires uniformly clean manner etc complete all as specified and directed.
S&F in replacement branded steel sheet MCCB enclosure box along with 250 A, 4 pole 16 ka MCCB, completely connected with copper thimble and with all accessories, complete all as specified and directed.
S&F in replacement MCCB 4 pole ,415 V, Adjusting type ,200 Amps,with breaking capacity of 36 KA, complete all as specified and directed.
FIRE FIGHTING Excavation in trenches not exceeding 1.5 meters wide and not exc. 1.5 meters deep for laying PVC under ground cable and CI/GI pipe line any type of soil, getting out and leveling of bottom surface to required level, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick, complete all as specified and directed.
Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point, complete all as specified and directed.
Supply and fixing single headed Stainless Steel fire hydrant landing valve type A (Single Head Outlet) of 80mm dia landing valve with 63mm dia female outlet comlete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, sutable for brigade hose of 63mm with couplings conforming to IS 903 including taking down the existing one, complete all as specified and directed.
Supply and fix fire Hydrant stand post with provn of single outlet conforming to IS 908, 63 mm dia inlet with rubber blank cap and chain as per IS 5290-1983, sutable for brigade hose of 63mm with couplings conforming to IS 908 including taking down the existing one, complete all as specified and directed.
Supply and fixing of weather proof standard fire hose box made of 18 SWG gauge MS sheet 800mmx80mmx250mm with double door with 4mm thick glasses and door frame including locking arrangement by allen key stove enamelled fire red finish with 'Fire hose' marked on front and brilliant white inside yard suitable for housing of and consisting of 2 lenghts RRL hose pipe conforming to IS 636-1979 (type-II) of 63mm dia including taking down the existing, complete all as specified and directed.
Supply and fixing in position 63mm nominal bore and 15 mtr long synthetic fibre circular woven jacketed rubberized fabric reinforced rubber lined (RRL) fire hose pipe of approved make bearing IS 636-1988 type A mark and heavy duty delivery hose coupling (conforming to IS ; 903) bound and riveted to the hose pipe with copper fivets and copper wire complete all as specified and including taking down the existing one, complete all as specified and directed.
Supply and fixing position Stainless steel 63mm dia short size branch pipes with 20mm dia nozzles with 63mm instantaneous copling ISI marked (IS; 903) and including taking down the existing one, complete all as specified and directed.
Supply, fixing, testing and commissioning of wall mounting swinging type first aid fire hose reel with drum size hanging bracket thermoplastic rubber (first aid hose) as per IS 12585 20mm dia 30mtr lenght to with stand 10 Kg per sq cm working pressure fitted with gunmetal nozzle and shut off valve of any size complete all as specified the hose reel shall be conforming to IS 884-1985 including for 25mm dia MS pipe connection from riser to hose relel sockets nipples elbows valve etc Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete hook or MS stand as per site requirment and the rate for fixing/hanging items in the rates quoted (for internal hydrant and one as either side of stage) including taking down the existing one, complete all as specified and directed.
Supply & fixing Gun metal gate valve with iron wheel head screwed both iron iron pipe ISI Marked as per IS 778 of following sizes including taking out unserviceable gate valve, complete all as specified and directed for the following sizes :-
(a) 25mm bore
(b) 50mm bore
Supply, fixing, testing and commissioning of 150 mm dia pipe heavy duty class "C" MS pipe ,ISI marked as per IS: 1239 with all necessary fittings and fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer including taking down the existing one, complete all as specified and directed for the following sizes :-
All as per Sri No 50 here in before but size 80mm
All as per Sri No 50 here in before but size 25mm
Supply, fixing, jointing & testing cast Iron Sluice Valve of following size ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve, complete all as specified and directed for the following sizes :- Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
(a) 80 mm Dia
(b) 150 mm Dia
Supply, fixing, jointing and testing of Cast iron Non Return valve of following Sizes without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.6, complete all as specified and directed for the following sizes :- Note :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
(a) 80 mm Dia
(b) 150 mm Dia
Supply, fixing, jointing & testing cast Iron Butterfly Valve of size150 mm dia ISI Marked,class (PN-1.0,) , complete all as specified and directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
Supply, fixing, jointing & testing in replacement of Bourdon type presure gauge with gun metal isolation cock and copper 'U' Tube having calibration of 0-10 Kg/cum and 100mm dia size all as specified pressure gauge, complete all as specified and directed.
Supply, fixing, jointing & testing in replacement of presure switches IPS 100 or approved equivalent including making connection with the control panel and the presure vessel complete in all respects the electric continuity is maintained between contacts NC and COM under normal conditions the contacts changeover to No & COM on rise of presure to preset valve all as including taking out of unserviceable presure switches, complete all as specified and directed.
Supply, fixing, jointing & testing in replacement of gun metal Air release valve of size 25mm dia having rubber ball (of suitable range and calibrated complete screwed both ends for iron pipe including all accessary (nut bolt washers) ISI marked as per IS; 778 of following size including taking out unserviceable bridge, complete all as specified and directed.
Supply, fixing, jointing & testing of Gun metal 4 way Fire brigade inlet to down commer line with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS ; 904 with blank cap and chain existing one complete including all accessary (nut bolt washers) and including taking out unserviceable fire bridge, complete all as specified and directed.
Mateial and labour for painting with one of synthetic enamelled paint as per approved colour code of fire fighting Riser pipe line (80mm to 150mm dia) in fire nitch ground floor to terrace pipe lines inside the the shaft, complete all as specified and directed.
Mateial and labour for painting with one coat of synthetic enamelled paint as per approved colour code of fire fighting station induction motor coupled with fire pump on terrace pump house, complete all as specified and directed.
M&L for brick work sub class 'B' old size brunt bricks for cable protection of size 230mmx115mmx75mm, complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces of walls finished even and smooth without using extra cement , complete all as specified and directed.
Supply, fixing, jointing & testing in replacement of manual call point beark glass type enclosed in MS enclosures body of 3mm thickness complete with chain and hammer and Incl inscriber in case of fire break glass compete including all connected accessary and taking down the unserviceable manual call, complete all as specified and directed.
Supply, fixing, jointing & testing in replacement of Electrically operated Electronic Hooter enclosed in MS enclosures of suitable size painted with sythetic enamaled paint red coloured complete with suitable transformer including all connected accessary and taking down the unserviceable hooter, complete all as specified and directed.
Supply, fixing, jointing & testing and commissioning of 2x1.5sq. mm..+1x1.0sqmm earth wire 1100 voltes solid/multi stranded copper conductor PVC sheathed cable including suitable size of lugs for connection from pressure switch to MCB including making good the surface of wall after replacement of conductor and taking down the unserviceable conductor, complete all as specified and directed.
Supply, fixing, jointing & testing and commissioning of floor mouting type cylindrical pressure vessel with supporting legs size 150mm dia and 1.5Mtr high with dished end and knuckle radius (IS;2062) the vessel shall be made of 8mm thick MS plate welded alround with sockets/flanges welded for inlet outlet and scour pipes pressure gague pressure swiotches air release valve etc. of suitable required size the pressure vessel shall be painted inside with anti-corrosive cpoxy paint and outside with two or more coats of synthetic enamel paint of fire red colour over a coat of ready mixed primer both of approved quality inincluding taking down the unserviceable pressure vessel, complete all as specified and directed.
S&F inlcuding Testing, commissioning of Centrifugal Booster pump set for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 900 LPM discharge all as specified and directed by Engineer-in-Charge.
Supplying and fixing testing and commissioning of Main fire indicating panel with ten number of Zones complete vise-versa, necessary controls LED indicators auxillary power supply test acept and reset push buttons local hooter and provision foe passing on the panel battery back -up for 24 hours nrmol and 30 min alarm condition etc to be fixed in still floor with all connected necessary accessory including taking down the unserviceable fire including panel all as specified and directed by Engineer-in-Charge.
Supplying and drawing 1.5 sqmm of PVC insulated 1100 volts copper conductor singal core cable in the existing surface/recessed PVC/steel condult/PVC casing and capping as requiredall including making good the surface after replacement of conductor and taking down unserviceable conductor, complete all as specified and directed.
M&L for installation and commissioning of FRP Panel Tank on the roof of Capacity 25000 Litres, Dimesnions of the tank as per the available roof size including making inlet and outlet connections , complete all as specified and directed.
M & L for PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement, complete all as specified and directed.
ASSOCIATED CONSTRUCTION CO. (BID ID -3271403)
M/s. Kansal Construction Co. (BID ID -3271182)
M/s Innovative Coolings and Constructions (BID ID -3271529)
Third Wave Services Pvt Ltd (BID ID -3271179)
L G BUILDERS (BID ID -3271421)
JYOTI ENTERPRISES (BID ID -3271399)
Khairati Lal (BID ID -3271155)
M/s. Kansal Construction Co. (BID ID -3271182)
M/s Innovative Coolings and Constructions (BID ID -3271529)
L G BUILDERS (BID ID -3271421)
Third Wave Services Pvt Ltd (BID ID -3271179)
JYOTI ENTERPRISES (BID ID -3271399)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
164049358.pdf
Tender Documents • 0.46 MB
164049359.html
Tender Documents • 0.06 MB
165949052.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .