Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC | ₹26.1 L Quoted ₹26.6 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹27.0 L+₹43,317 (1.63%)Rejected-Finance KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | ₹27.0 L+₹43,317 (1.63%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹27.1 L+₹54,402 (2.05%)Rejected-Finance | ₹27.1 L+₹54,402 (2.05%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹28.5 L+₹1.9 L (7.15%)Rejected-Finance | ₹28.5 L+₹1.9 L (7.15%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹28.6 L+₹2.1 L (7.73%)Rejected-Finance | ₹28.6 L+₹2.1 L (7.73%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Jan 2025, 6:00 pmClosed
GE Silchar
GE Silchar Masimpur Assam 788025
REPAIR AND MAINT OF EXTERNAL ELECTRIFICATION OF CIJW SCHOOL VAIRENGTE AND LAILAPUR UNDER GE SILCHAR
2024_MES_688121_1
8931/E8
Open Tender
Civil Works
Item Rate
180 days
Vairengte
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Silchar
₹50,000
Yes
5 Feb 2025
11 Dec 2024
5 Jan 2025
11 Dec 2024
3 Jan 2025
26 Dec 2024
14 Dec 2024 - 21 Dec 2024
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose/hard/dense soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as foundation filling, mass concrete, etc. complete all as specified and as directed
M&L for plain cement concrete 1:3:6 (type C-1) using 20mm graded stone aggregate as incoping to poles, stay assembly, etc. with or without champered angles and flat, splayed, rounded or mitred tops, etc. including all necessary formwork surfaces finished even and fair without using extra cement complete all as specified and as directed
Taking up or down LT UG cable of any size from trenches/poles, complete all as specified and as directed.
Takin down old unserviceable steel / RCC electric poles at any locations including shutting of power lines, etc. and carting and disposing complete all as specified and as directed
Taking up or down of HT/LT UG cable and bricks from trenches/poles and removed from site complete all as specified and as directed. Note: (i) Excavation,earthwork, brick protection,sand cushion & GI pipe shall be measured and paid seperately under respective of this schedule. (ii) The cost of taking out old bricks of cable protection shall be deemed to be included in the unit rate of this item.
Dismantling old UNSV air break gang operated switches vertical/horizontal mounted incl insulator and operating mechanism for repair/replacement of broken/worn out components and insulators etc, complete all as specified and as directed.
Dismantling drop out expulsion fuse single pole, complete all as specified and as directed.
Disconnecting /taking down old UNSV service wire twin core aluminium conductor of any sizes with their suspension wire from pole as well as building, complete al as specified and as directed
Taking up or down steel water tubing of size 80mm/50mm/40mm and connections from any location / position, including sorting and stacking serviceable tubings and disposing off unserviceable, etc. complete all as specified and as directed.
Supplying, fixing / laying steel water tubing, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings including all necessary welding, etc. as required at site complete all as specified and as directed for the following bores:
Supplying, laying / fixing, testing and commissioning of electric cable, 1100V grade aluminium conductor XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
3.5 core 240sqmm
3.5 core 120sqmm
3.5 core 95sqmm
3.5 core 70sqmm
3.5 core 50sqmm
3.5 core 35sqmm
3.5 core 25sqmm
4 core 16sqmm
4 core 10sqmm
M&L for cable jointing kit for 1100V grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core 25 to 50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1100V grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core 70 to 120mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1100V grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core 150 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
S&F shackle type porcelain vitreous white, brown or green insulator of size 75mm height 90 mm dia including MS strips 31x3mm washers, insulator bolts 12mm dia & nuts suitable for working pressure 1100V grade complete all as specified and as directed
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 100mm dia for 1100V grade complete all as specified and as directed
M&L for cutting / trimming / prunning branches of trees, exceeding 15cm but not exceeding 30cm in dia, falling over HT lines, cutting to make minimum distance of 3m from OH lines of any type span of any length in 2/4/6 way conductor system, including all neceessary safety precautions, shutting of supply, staging, barricading, roping down the cut branches, suitable cutters, etc. and disposing off the cut branches to a suitable place at a distance not exceeding 50m complete all as specified and as directed
M&L for preparation of old surfaces and applying two coats of lime/ white wash on all surfaces of PCC coping arounf poles of any size not more than 0.45x0.45x0.45m complete, all as specified and as directed.
S&F in repairs LT feeder pillar box/panel door shutters made in shapes & sizes as required at site, dust and vermin proof, IP65 protection class, fabricated out of 3.15mm thick CRCA MS sheet and 50x50x5mm thick angle iron frame work, with hinges and suitable locking arrangements duly spray painted with one coat of Duco paint over a coat of red oxide zinc chrome primer complete all as specified and as directed
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, pole caps, bolts, nuts and screws type 410 SP-31, 9m long, conforming to IS: 2713, with detachable bracket arms including two coats of aluminium paint over shop coat of primer complete all as specified and as directed Note: Excavation / earthwork and PCC coping etc. will be measured and paid separately under respective items herein
M&L for preparation of old steel surfaces of LT feeder pillar box /panle board of various size and completely removal of exisiting treatment by scrapping or chemical and surface painted with DUCO paint with the help of spray gun over a coat of red oxide primer, complete all as specified and as directed
Supply, installation, commissioning and testing CPRI approved LT feeder pillar box, outdoor type of size 1000x800x500mm, cubical floor mounted type (IP-65 degree of protection) made out of 3.15mm thick powder coated CRCA sheet , with aluminium strip bus bar 400A rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415V 50Hz AC supply, including cable entry boxes, cable gland, with 50x50x6mm angle iron supports, bottom portion duly grouted in PCC foundation as per manufacturer's instructions including the following switchgears complete all as specified and as directed Incoming (a) MCCB 250A, 4 pole, 36kA, Icu=100%Ics- 01No (b) Phase indicator lamps (RYB) set of 3- 01set Outgoing - Through bus bar
Notes for serial item Nos. 39 to 40: (a) The Contractor shall submit drawings from the approved OEM for approval of the GE through the Engineer-in-charge (b) The panels shall include 2Nos. danger notice plates made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 250x200mm with letter, figures and conventional skull bones in signal red colour duly fixed with nuts, bolts and washers, etc. with voltage and danger indicated both in Hindi and English (c) Excavation, earthwork in any type of soil, construction of PCC foundation for panel shall be deemed included in quoted rate. Foundation specifics shall be as per OEM of panel. The Contractor shall submit foundation desgn drawings to attain approal of he GE (d) Foundation bed shall be in PCC 1:3:6 type C2 using 40mm graded stone aggregates with a depth of 15cm below ground level and 1.5m above ground level with stare and slot openings for I/C and O/G cables
M&L for replacment of UNSV silica gel grains in lieu providing with new silica gel grain for exisiting breather assmebly of any capacity transformer, complete all as specified and as directed
Supply only 40mm to 80mm graded stone aggregates, complete all as specified and as directed.
S&F triple pole, mechanically operated air break isolator (GOD), vertical horizontal mounting, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect suitable for 11000 volts graded,50Hz with 9 insulator of current rating upto 400Amps, complete all as specified and as directed.
S&F drop out expulsion fuse unit suitable for 11KV of capacity upto 100Amps mounted on MS channels complete with two post insulator 11KV including required hardware like clamps nuts bolts washers synthetic bonded fuse barrels etc all as specified and as directed.
S&F lightening arrestor expulsion type for 11KV capacity, complete all as specified and as directed.
S&F aluminium lugs suitable for UG cable of size 3.5/4 core , 16 to 35sqmm and making connection to MCCB/MCB including orrespective of lugs for the neutral cable, complete all as specified and as directed.
S&F aluminium lugs suitable for UG cable of size 3.5/4 core , 50 to 95sqmm and making connection to MCCB/MCB including orrespective of lugs for the neutral cable, complete all as specified and as directed.
S&F in repairs MCCB 63A 4 Pole, 415V, AC, Ics=100%Icu, 80 to 100% overload protection, adjustable type, with thermal magnetic release mechanism, breaking capacity 16kA including all necessary lugs, wire, etc. required for connecting up complete all as specified and as directed
S&F in repairs MCCB 100A 4 Pole, 415V, AC, Ics=100%Icu, 80 to 100% overload protection, adjustable type, with thermal magnetic release mechanism, breaking capacity 16kA including all necessary lugs, wire, etc. required for connecting up complete all as specified and as directed
S&F in repairs MCCB 125A 4 Pole, 415V, AC, Ics=100%Icu, 80 to 100% overload protection, adjustable type, with thermal magnetic release mechanism, breaking capacity 16kA including all necessary lugs, wire, etc. required for connecting up complete all as specified and as directed
S&F in repairs MCCB 160A 4 Pole, 415V, AC, Ics=100%Icu, 80 to 100% overload protection, adjustable type, with thermal magnetic release mechanism, breaking capacity 36kA including all necessary lugs, wire, etc. required for connecting up complete all as specified and as directed
S&F in repairs MCCB 200A 4 Pole, 415V, AC, Ics=100%Icu, 80 to 100% overload protection, adjustable type, with thermal magnetic release mechanism, breaking capacity 36kA including all necessary lugs, wire, etc. required for connecting up complete all as specified and as directed
S&F in repairs MCCB 250A 4 Pole, 415V, AC, Ics=100%Icu, 80 to 100% overload protection, adjustable type, with thermal magnetic release mechanism, breaking capacity 36kA including all necessary lugs, wire, etc. required for connecting up complete all as specified and as directed
S&F in repairs changeover switch 125A, 4 pole, 50kA, 415V, 50Hz, AC, I-O-II operation manual type, open / closed construction as per site requirement, adjustable type of thermal and magnetic setting handle, including all necessary cable lugs, wires, etc. complete all as specified and as directed
S&F in repairs changeover switch 250A, 4 pole, 50kA, 415V, 50Hz, AC, I-O-II operation manual type, open / closed construction as per site requirement, adjustable type of thermal and magnetic setting handle, including all necessary cable lugs, wires, etc. complete all as specified and as directed
M&L for danger notice plates, for LT of size 20x15cm, made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts including taking down old / damaged notice plates and disposing off complete all as specified and as directed
M&l for applying one coat aluminium paint on 9m long steel tubular pole in position after preparation of surface of steel tubler pole including all fitted cross arms, clamp, nut, bolt, etc. including painting of black and yellow stripes of 5Nos. of 30cm wide stripes or as directed on pole upto 1.5m height above coping level including numbering of size 70x40mm by using stencil on the pole with black synthetic enamel paint 1.5m above ground level complete all as specified and as directed
Supply, fix or lay in position synthetic rubber insulated mat of size 2.0x1.0m and 25mm thick suitable for 11kV conforming to IS-15652-2006 (superseding IS-5424) complete all as specified and as directed
S&F standard SS first aid box of size 250x200x150mm comprising of all necessary first aid medicines and marked with 'FIRST AID BOX' including all necessary mounting arrangements on wall complete all as specified and as directed
S&F ACB 4 Pole, 630A, 415V, manual drawout type with adjustable thermal and magnetic setting including taking out old unserviceable ACB and disposing off complete all as specified and directed
M&L for 6mm steel wire rope ASIS 326 grade of 15m high mast lighting system including taking off old damaged rope complete all as specified and as directed
M&L for mobil and grease oil for servicing of motor, chain, pully of 15m high mast lighting system complete all as specified and as directed
M&L for mobil and grease oil for servicing of motor, chain, pully of 30m high mast lighting system complete all as specified and as directed
S&F 1100V grade heavy duty PVC insulated aluminium multistranded conductor cable, 2 core 10sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1m apart including 4mm suspension wire, two twin core cable flat or circular including taking down old unserviceable wire and disposing off complete all as specified and as directed
M&L for earthing using GI earthing strip with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 25x4mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Notes for serial item No. 66: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
M/S SANJIB DEB (BID ID -3204994)
m/s builders and suppliers (BID ID -3205087)
SURANA CORPORATION (BID ID -3205202)
M/S M P Sharma (BID ID -3203364)
M/S LUIT CONSTRUCTION (BID ID -3204402)
M/S TAPAN KUMAR RAY (BID ID -3201230)
M/S R A ENTERPRISE (BID ID -3200690)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .