Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 1367 19 FRONT D A V PUBLIC SCHOOL ROHTAK JGD PUBLIC SCHOOL KAMLA NAGAR ROHTAK | ROHTAK | HARYANA | 124001 | L1 | Accepted-AOC accepted | |
| 2 | L2₹3.9 L+₹24,445 (6.61%)Rejected-AOC GALI NO 01 NEAR HUNAMAL PAU NEW DEFENCE COLONY ROAD BHIWANI TEHSIL AND DISTRICT BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | L2 | Rejected-AOC rejected | |
| 3 | L3₹4.2 L+₹52,445 (14.2%)Rejected-AOC H NO 959 SECTOR 3 ROHTAK | L3 | Rejected-AOC rejected | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical rejected |
| Sl No | Description | Qty | Unit | DEVENDER KUMAR CONTRACTOR L3 | M.K.ENGINEERS L1 | BHARAT TRADERS L2 |
|---|---|---|---|---|---|---|
| 1.00HSR Items | ||||||
| 1.01 | [23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] | 460 | P.Metre | 120 ₹55,200 | 99 ₹45,540 Lowest | 120 ₹55,200 |
| 2.00 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 250 | P.Metre | 35 ₹8,750 | 30 ₹7,500 Lowest | 40 ₹10,000 |
| 3.00NS Items | ||||||
| 3.01 | Supply and Erection of 1.8/2.0 Ton 2 star or above Split type Air Conditioner (non-inverter), Suitable for 150-200 sq. feet, Cooling Capacity 6400 W, 230V/ Single Phase/50 Hz, Rated cooling Capacity 21840 BTU/H or above, rated ISEER 3.45 or above, White colour, Airflow rate 16.6 m3/min, Operation sound (H/M/L) 49/45/39 Copper Coil, Rotary Compressor, mositure removal(litres/Hour) 2.6, Operating Voltage 170-280 V, Refrigerant Gas R32 Environment friendly, operating ambient temperature range 19.4-50 Deg., with 1 Year Comprehensive warranty on machine and Compressor Warranty 05 years and including all the petty material as supplied by the manufacture to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. Make: - Voltas / Daikin / Hitachi / Lloyd | 5 | Each | 45,500 ₹2,27,500 | 43,490 ₹2,17,450 Lowest | 45,400 ₹2,27,000 |
| 4.00 | Supply and Erection of suitable size of white powder coated metal AC Stand for Split AC complete in all respect upto enitre satisfaction of Engineer-in charge of the work. | 5 | Each | 750 ₹3,750 | 600 ₹3,000 Lowest | 1,000 ₹5,000 |
| 5.00 | Supply and Erection of 5 KVA automatic voltage stablizer with voltage 150 V to 280, Copper Wound Suitable for air conditioners complete in all respect upto enitre satisfaction of Engineer-in charge of the work. Make : Blue Bird / Microteck / V- Guard | 5 | Each | 4,000 ₹20,000 | 3,971 ₹19,855 Lowest | 5,200 ₹26,000 |
| 6.00 | Supply and Erection of 2.5 Sqmm 4 Core size copper electric wire suitable for Split air conditioners complete in all respect upto enitre satisfaction of Engineer-in charge of the work. Make: Havells / RR / Grandlay/ Polycab | 110 | P.Metre | 120 ₹13,200 Lowest | 175 ₹19,250 | 120 ₹13,200 Lowest |
| 7.00 | Supply and Erection of suitable size of Hard plastic Drain Pipe for Air Conditioner complete in all respect upto enitre satisfaction of Engineer-in charge of the work. | 40 | P.Metre | 100 ₹4,000 | 99 ₹3,960 Lowest | 100 ₹4,000 |
| 8.00 | Supply and Erection of Copper Pipe size 1/2` or 5/8` and 1/4` with insulation complete in all respect upto enitre satisfaction of Engineer-in -charge of the work. Make:Maxflow / Mandev / Totaline | 60 | P.Metre | 1,500 ₹90,000 | 890 ₹53,400 Lowest | 900 ₹54,000 |
Tender Value
₹4.1 L
EMD Value
₹8,300
Closing Date
11 Jul 2025, 2:00 pmClosed
AMIT GOYAL
ED - Rohtak
Provision of 1.8/2.00 Ton split Air conditioner, AC outdoor stand, copper pipe, drain pipe including electric wire have been taken in this estimate.
2025_HRY_456371_1
202521B21762 ED8C 4AC2 816C DE433872DAFA667BAR
Open Tender
Electrical Works
Works
30 days
Rohtak
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹500
₹8,300
Yes
8 Aug 2025
4 Jul 2025
11 Jul 2025
4 Jul 2025
11 Jul 2025
4 Jul 2025
Amount
HSR Items
[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
NS Items
Supply and Erection of 1.8/2.0 Ton 2 star or above Split type Air Conditioner (non-inverter), Suitable for 150-200 sq. feet, Cooling Capacity 6400 W, 230V/ Single Phase/50 Hz, Rated cooling Capacity 21840 BTU/H or above, rated ISEER 3.45 or above, White colour, Airflow rate 16.6 m3/min, Operation sound (H/M/L) 49/45/39 Copper Coil, Rotary Compressor, mositure removal(litres/Hour) 2.6, Operating Voltage 170-280 V, Refrigerant Gas R32 Environment friendly, operating ambient temperature range 19.4-50 Deg., with 1 Year Comprehensive warranty on machine and Compressor Warranty 05 years and including all the petty material as supplied by the manufacture to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. Make: - Voltas / Daikin / Hitachi / Lloyd
Supply and Erection of suitable size of white powder coated metal AC Stand for Split AC complete in all respect upto enitre satisfaction of Engineer-in charge of the work.
Supply and Erection of 5 KVA automatic voltage stablizer with voltage 150 V to 280, Copper Wound Suitable for air conditioners complete in all respect upto enitre satisfaction of Engineer-in charge of the work. Make : Blue Bird / Microteck / V- Guard
Supply and Erection of 2.5 Sqmm 4 Core size copper electric wire suitable for Split air conditioners complete in all respect upto enitre satisfaction of Engineer-in charge of the work. Make: Havells / RR / Grandlay/ Polycab
Supply and Erection of suitable size of Hard plastic Drain Pipe for Air Conditioner complete in all respect upto enitre satisfaction of Engineer-in charge of the work.
Supply and Erection of Copper Pipe size 1/2` or 5/8` and 1/4` with insulation complete in all respect upto enitre satisfaction of Engineer-in -charge of the work. Make:Maxflow / Mandev / Totaline
BHARAT TRADERS (BID ID -1293947)
DEVENDER KUMAR CONTRACTOR (BID ID -1294163)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .